SDR HEEA0013576Control Unit · failedGENERATOR WILL NOT COME ON LINE.SDR HEEA0013542Volt Regulator · failedGENERATOR SLOW TO COME ON LINE.SDR HEEA0013537Volt Regulator · failedVOLTAGE REGULATOR FAILED. GEN DROPS OFF LINE.SDR AU980411Diode · failed(AUS) DURING CRUISE, THE 'OVER-VOLTAGE' PROTECTION ZENER DIODE FAILED, CAUSING EXTENSIVE FAILURE OF ELECTRICAL AND AVIONICS EQUIPMENT.SDR HEEA0013468Regulator · failedVOLTAGE WILL NOT ADJUST.SDR HEEA0013420Control Unit · failedWILL NOT COME ON LINE. CONTROL UNIT FAILEDSDR HEEA0013419Control Unit · failedGENERATOR WILL NOT COME ON LINE. CONTROL UNIT FAILEDSDR HEEA0013418Control Unit · failedGENERATOR WILL NOT COME ON LINE. CONTROL UNIT FAILEDSDR HEEA0013389Regulator · failedNO GENERATOR OUTPUT. VOLTAGE REG FAILED.SDR 98ZZZX1849Regulator · noisyADF WOULD NOT POINT BELOW 500 HKZ DUE TO ELECTRICAL NOISE GENERATED BY ALTERNATOR SYSTEM. FOUND THIS TYPE UNIT CAUSED INTERFERENCE DUE TO SWITCHING FREQUENCY OF REGULATION SYSTEM. ELEIMINATED PROBLEM BY RETURNING ALTERNATOR CONTROL SYSTEM TO OLDER LOW FREQUESDR CA970807045Regulator · malfunctioned(CAN) CREW REPORTED ELECTRICAL BUS SEPARATION FOLLOWED BY AVIONICS CIRCUIT BREAKERS TRIPPING. LEFT GENERATOR DEEMED TO BE THE CAUSE AND WAS ISOLATED. MAINTENANCE FOUND THAT THE LEFT HAND GENERATOR CONTROL UNIT FAILED.SDR HEEA0013246Regulator · failedVOLTAGE REGULATOR UNABLE TO ADJUST VOLTAGE.SDR 98ZZZX1141Gcu · failedDC GENERATOR CONTROL RECEIVED FROM CUSTOMER FOR REPAIR. DURING INSPECTION, FOUND UNIDENTIFIABLE MODIFICATION ON CIRCUIT BOARD NR 51539-1081 REV E AND CIRCUIT BOARD NR 51539-1061 REV D WHEN THERE ARE NO MODIFICATIONS FOR THESE BOARDS OTHER THAN REPLACEMENT. DSDR HEEA0012967Volt Regulator · failedGENERATOR SLOW TO COME ON LINE. VOLTS REG FAILEDSDR HEEA0012962Regulator · failedDC REG FAILED. PEGS VOLTMETER.SDR HEEA0012961Regulator · defectiveVOLTS REG DEFECTIVE. NOT ADJUSTABLE ABOVE 270 FEET.SDR HEEA0012952Regulator · failedNR 2 GENERATOR INOPERATIVE. PUTS OUT VOLTAGE BUT NO AMPERAGE.SDR HEEA0012939Volt Regulator · defectiveGENERATOR WOULD FALL OFF LINE BUT WOULD RESET EACH TIME.SDR HEEA0012929Volt Regulator · failedCAUSES STARTER TO RUN AFTER SHUTDOWN.SDR HEEA0012927Volt Regulator · failedGENERATOR WILL NOT COME ON LINE.SDR MALA975955Gcu · failedRIGHT GENERATOR FAILED IN FLIGHT, AFTER RESETTING, IT FAILED AGAIN. AIRCRAFT RETURNED TO DTW. MAINTENANCE REPLACED RIGHT DC GCU, ALL CHECKS GOOD.SDR HEEA0012835Volt Regulator · failedREG DROPPED OFF LINE AND WOULD NOT RESET.SDR HEEA0012817Volt Regulator · failedVOLT REG NOT WORKING. GENERATOR WILL NOT COME ON LINE.SDR HEEA0012816Volt Regulator · failedGENERATOR DOES NOT COME ON. REG FAILEDSDR HEEA0012641Regulator · failedGENERATOR WILL NOT COME ON LINE. REG FAILEDSDR 98ZZZX1396Gcu · failedPILOT REPORTED GENENRATOR WILL NOT COME ON-LINE. REPLACED GENERATOR CONTROL UNIT. OPERATIONS NORMAL.SDR HEEA0012451Regulator · inoperativeVOLTAGE REGULATOR INOPERATIVE.SDR 98ZZZX46Regulator · shortedACFT EXPERIENCED OVERVOLTAGE CONDITION THAT CAUSED SYSTEMS THAT WERE TURNED ON TO FAIL, AND ALL RADIOS TO PRODUCE HEAVY SMOKE. REGULATOR TEAR-DOWN REVEALED LARGE RESISTOR FOUND INSIDE UNIT UNATTACHED. IT APPEARS RESISTOR WAS NOT PROPERLY ATTACHED TO C/B. IFSDR HEEA0012292Volts Regulator · failedNO. 1 GEN WILL NOT COME ON LINE.SDR HEEA0012290Regulator · failedWILL NOT COME ON LINE WITH ANOTHER GENERATOR ON.SDR HEEA0012289Volts Regulator · failedVOLTAGE REGULATOR FAILED. WILL NOT SHARE THE LOAD WITH THE OTHER SYSTEMS.SDR HEEA0012282Volts Regulator · failedGENERATOR WOULD NOT COME ON LINE.SDR HEEA0012144Volt Regulator · failedVOLT REG WILL NOT STAY ON LINE.SDR 98ZZZX566Regulator · failedVOLTAGE REGULATOR UNIT FAILED UPON INITIAL USE. REMOVED AND REPLACED.SDR HEEA0012049Regulator · failedGENERATOR WILL NOT COME ON LINE.SDR HEEA0012048Regulator · failedGENERATOR DROPS OFF LINE.SDR 98ZZZX739Regulator · failedAIRCRAFT TT: 100.5 HOURS. AFTER ONE HOUR OF FLIGHT, THE VOLTAGE INCREASED FROM 28.5 TO 30.5 VOLTS AND STABILIZES AT 30.5 VOLTS. REMOVED AND REPLACED VOLTAGE REGULATOR WITH NEW.SDR CA971216050Voltage Regulatr · failed(CAN) DURING CRUISE, RIGHT HAND DC GENERATOR WENT OFF-LINE AND COULD NOT BE RESET. MAINTENANCE INVESTIGATION REVEALED THAT VOLTAGE REGULATOR WAS REGULATING AT A HIGH VOLTAGE RATE AND COULD NOT BE ADJUSTED. THIS RESULTED IN NR 1 DC GENERATOR TAKING MOST OF THSDR HEEA0011941Regulator · failedGENERATOR WOULD NOT COME ON LINE.SDR HEEA0011940Regulator · failedGENERATOR WOULD NOT COME ON LINE.SDR HEEA0011880Regulator · failedVOLTAGE WILL NOT STAY SET.SDR HEEA0011878Regulator · failedGENERATOR FALLS OFF LINE AFTER 20 MINUTES.SDR HEEA0011829Regulator · defectiveGENERATOR WILL NOT RESET. REGULATOR POTENTIOMETER IS CORRODED AND DUAL RESISTOR IS CRACKED AND CHIPPED.SDR HEEA0011692Regulator · failedREGULATOR MALFUNCTION, WILL NOT REGULATE, TRIPS ON OVER VOLTAGE.SDR HEEA0011637Regulator · failedGENERATOR DOES NOT COME ON LINE.SDR HEEA0011632Regulator · failedREGULATOR HAS NO VOLTAGE OUTPUT.SDR 97ZZZX4639Regulator · failedAIRCRAFT ELECTRICAL SYSTEM EXPERIENCED ON ABRUPT MALFUNCTION, NO CHARGING CONDITION. FOUND VOLTAGE REGULATOR FAILED.SDR HEEA0011517Regulator · failedGENERATOR GOES OFF LINE.SDR HEEA0011325Volt Regulator · failedVOLTAGE REGULATOR FAILED GENERATOR WONT COME ON LINE.SDR HEEA0011141Regulator · failedVOLTAGE REGULATOR DEFECTIVE. GENERATOR WOULD NOT COME ON LINE.
Back to JASC 2436