SDR LS1R065943Volt Regulator · shortedVOLTAGE REGULATOR SHORTED OUT.SDR LS1R065936Volt Regulator · shortedVOLTAGE REGULATOR SHORTED OUT.SDR AGQA065942Volt Regulator · inoperativeVOLTAGE REGULATOR INOPERABLE. WILL NOT REGULATE.SDR AGQA065935Volt Regulator · inoperativeVOLTAGE REGULATOR INOPERABLE, WILL NOT REGULATE.SDR AGQA065549Volt Regulator · erraticFIELD VOLTAGE INTERMITTENT, OVERVOLTAGE CONDITION.SDR AGQA065533Volt Regulator · failedVOLTAGE REGULATOR UNABLE TO POWER UP.SDR 2000ZZZX13Volt Regulator · failedIN CRUISE FLIGHT, SMOKE IN COCKPIT. SMOKE EMANATING FROM MAST MOMENT INDICATOR. AIRCRAFT DIVERTED TO ICY FOR MAINTENANCE, OVER-VOLTAGE CAUSED BY THE VOLTAGE REGULATOR.SDR HEEA065213Regulator · failedVOLTAGE REGULATOR NOT EXCITING FIELD.SDR MALA976576Gcu · failedLT DC GEN DROPPED OFF LINE. CREW FOLLOWED QRH, GEN RESET 10 MIN LATER LT DC GEN DROPPED OFF LINE AND WOULDN'T COME BACK ON LINE, UNTIL APPROX 10 MINUTES LATER. AIRCRFAT RETURNED TO DTW. MAINTENANCE REPLACED LT DC GCU. ALL CHECKS GOOD.SDR HEEA063432Regulator · failedVOLTAGE REGULATOR WOULD NOT SHARE LOAD.SDR HEEA063253Volt Regulator · failedGENERATOR FALLS OFF-LINE, WILL NOT RESET.SDR AU990460Regulator · misinstalled(AUS) INCORRECT VOLTAGE REGULATOR FITTED.SDR HEEA061812Regulator · failedUNABLE TO ADJUST VOLTAGE ON VOLTAGE REGULATOR.SDR HEEA061563Volt Regulator · failedVOLTAGE REGULATOR WILL NOT COME ON LINE.SDR HEEA060921Regulator · malfunctionedVOLTAGE WENT PAST 30 PLUS VOLTS - WILL NOT ADJUST.SDR HEEA060761Regulator · malfunctionedUNABLE TO ADJUST ABOVE 26.5 VDC.SDR HEEA060176Regulator · failedREGULATOR INOPERATIVE.SDR HEEA060169Regulator · failedVOLTAGE REGULATOR WILL NOT MAINTAIN 28 VOLTS.SDR HEEA060023Regulator · failedGENERATOR WILL NOT COME ON-LINE.SDR AU981420Regulator · malfunctioned(AUS) VOLTAGE REGULATOR SUSPECT FAULTY.SDR AU981285Regulator · corroded(AUS) VOLTAGE REGULATOR TERMINALS SEVERELY CORRODED. SWITCHED WIRE ALSO CORRODED AND BROKEN AT SPADE TERMINAL.SDR AU981576Regulator · misinstalled(AUS) AUTOMOTIVE TYPE VOLTAGE REGULATOR (BOSCH) FITTED INSTEAD OF THE CORRECT UNIT. INSPECTION ALSO FOUND THAT THE OVERVOLTAGE CONTROL UNIT HAD BEEN REMOVED AND THE REGULATOR HAD BEEN INCORRECTLY WIRED.SDR 98ZZZX3637Regulator · failedWILL NOT REGULATE VOLTAGE. REPLACED.SDR 98ZZZX3634Regulator · failedGENERATOR DROP, OFFLINE, WILL NOT ADJUST ON VOLTAGE. REPLACED AND SENT FOR REPAIR.SDR HEEA0015875Regulator · failedVOLTAGE REGULATOR IS OVER VOLTAGE.SDR CA980908012Resistor · misinstalled(CAN) RESISTOR INSTALLED NOT AS REQUIRED BY MANUFACTURER.SDR AU981232Regulator · failed(AUS) LKH VOLTAGE REGULATOR FAULTY.SDR AU981233Regulator · failed(AUS) LEFT VOLTAGE REGULATOR FAILED.SDR AU980890Regulator · failed(AUS) LEFT VOLTAGE REGULATOR FAILED. HIGH VOLTAGE OUTPUT CAUSED BATTERIES TO BOIL WITH CONSEQUENT ACID SPILLAGE.SDR 98ZZZX2879Voltage Reg · malfunctionedDURING CRUISE FLIGHT, CREW NOTICED ALL LIGHTS IN COCKPIT, RADAR SCREEN, AND GPS SCREEN WOULD FLASH ON AND OFF EVERY FEW MINUTES. KILOWATTS ON THE NR 1 WOULD SPIKE TO 25 TO 30 KILOWATTS. NR 2 GENERATOR WOULD DO THE SAME THING. BTB ILLUMINATED. COULD NOT BRISDR 98ZZZX3076Regulator · failedOVERVOLTAGE LIGHT CAME ON IN-FLIGHT. REPLACED VOLTAGE REGULATOR.SDR 98ZZZX2797Regulator · failedVOLTAGE REGULATOR WILL NOT ADJUST. SENT FOR REPAIR.SDR 98ZZZX2787Regulator · failedVOLTAGE REGULATOR WILL NOT ADJUST. REMOVED FROM AIRCRAFT AND SENT FOR REPAIR.SDR 98ZZZX2792Regulator · failedVOLTAGE REGULATOR WILL NOT HOLD VOLTAGE. REMOVED FROM AIRCRAFT AND SENT TO REPAIR.SDR HEEA0014746Regulator · failedGENERATOR WOULD NOT STAY ON LINE.SDR VJ9800189Voltage Reg · failedNR 1 GENERATOR LIGHT OFF, UNABLE TO START APU INFLIGHT. REPLACED VOLTAGE REGULATOR.SDR HEEA0014593Control Unit · failedSTARTER GENERATOR WILL NOT COME ON LINE.SDR HEEA0014579Control Unit · inoperativeGENERATOR CONTROL UNIT INOPERATIVE.SDR HEEA0014445Control Unit · failedCONTROL UNIT FAILED. GENERATOR WILL NOT COME ON-LINE.SDR 98ZZZX2346Regulator · failedUNIT REQUIRED BY AD 97-20-04 FAILED AFTER 50 HOURS. EIGHTY PERCENT OF THE UNITS FAIL TEST. SUBMITTER STATED THEY SHOULD BE RETIRED FORM SERVICE AS UNRELIABLE. USED ON MOST OLD PIPERS, ENSTROM, AND MANY OTHER AIRCAFT. AT LEAST ONE ACCIDENT WAS CAUSED BY THISDR AU980556Regulator · failed(AUS) VOLTAGE REGULATOR FAILED. OVERVOLT SENSOR FAILED TO TRIP CAUSING DAMAGE TO ELECTRICAL COMPONENTS.SDR 98ZZZX2100Regulator · failedVOLTAGE REGULATOR WILL NOT HOLD A VOTLAGE SETTING, KEEPS FLUCTUATING. SENT FOR REPAIR. REF: CONTROL NR 98-5-8.SDR HEEA0014159Regulator · failedVOLTAGE GOES TO 30 VOLTS AND WILL NOT ADJUST.SDR HEEA0014106Control Unit · failedGENERATOR WOULD NOT COME ON LINE.SDR 98ZZZX1738Regulator · failedVOLTAGE REGULATOR WILL NOT STAY ON LINE AND CANNOT BE ADJUSTED. REMOVED AND REPLACED AND SENT FOR REPAIR. CONTROL NR 98-4-11.SDR HEEA0013939Generator Contro · failedCAUSING A/C GENERATOR TO KICK OFF LINE.SDR HEEA0013725Control Unit · failedGENERATOR WOULD NOT COME ON LINE.SDR HEEA0013605Control Unit · failedGENERATOR KICKS OFF.SDR HEEA0013582Volt Regulator · failedGENERATOR WILL NOT COME ON LINE.SDR HEEA0013581Volt Regulator · failedCAUSES STARTER TO RUN AFTER SHUTDOWN.
Back to JASC 2436