JASC 2437

Service difficulty reports · 98

Reports filed under 2437 · DC Indicating System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2437'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AUS20020214Ammeter · faulty(AUS) AMMETER FAULTY.Feb 23, 2002 · Cessna TR182SDR MEX2002045Warning System · malfunctionedFLT 180 - MLM-HMO - DURING TAXI, CAPTAIN INFORMED THAT DC BUS OFF LIGHT IS ON. RESET THE CIRCUIT BREAKER, LIGHT WAS NOT OFF. AIRCRAFT RETURNED TO PLATFORM. BOTH BATTERIES WERE DISCONNECTED AND CONNECTED, RESET THE RELAYS R2-21 AND R2-326, TEST OK, IAW MM 24Feb 20, 2002 · N491SH · Doug DC982SDR BSY2001F00019Sensor · failed(MKE)(MIR) LOST BOTH ALTERNATORS, THEN, RIGHT SIDE CAME BACK ON. REMOVED AND REPLACED BOTH ALTERNATOR OUT SENSORS. OPS CHECKS GOOD.Dec 7, 2001 · N5238J · Cessna 310RSDR HEEA073609Indicator · stuckNEEDLE STICKS, AMP METER SIDE.Jun 18, 2001 · N142PH · Bell 412SDR HEED072214Panel · will not testBATTERY FEED FAULT WILL NOT TEST PROPERLY. REPLACED UNIT.Mar 14, 2001 · N476X · Skrsky S76CSDR CA010409008Meter · faulty(CAN) PILOT REPORTED LOW VOLTAGE ON NR 2 BATTERY SYSTEM CHECKED AND IT WAS FOUND THE VOLT METER IN OVERHEAD ELECTRICAL PANEL WAS AT FAULT. WE COULD NOT REPLACE JUST THE METER SO A PANEL WAS ORDERED AND REPLACED. THE OLD PANEL WHEN REMOVED WAS FOUND TO HAVE SOMMar 9, 2001 · Pilats PC1245SDR 20000626SH012Wire · chafedPILOT REPORTED TO MAINTENANCE THAT THE LEFT AMP GAUGE WENT TO ZERO AMPS, BUT LEFT GENERATOR STAYED ON-LINE. INVESTIGATION REVEALED CHAFED WIRE BUNDLE IN LEFT MIB AT GROUND ATTACH POINT E253. REPAIRED 7 CHAFED WIRES AND PROTECTED AS NEEDED. SYSTEM OPS CHECKEMay 22, 2000 · N741MA · Mtsbsi MU2B26ASDR CA000419010Shunt · broken(CAN) BAKELITE BASE MOUNTING PADS CRACKED ALLOWING R/H LOADMETER SHUNT TO MOVE FORWARD ENOUGH TO ALLOW SHUNT WIRE TERMINALS TO TOUCH HEAT SINK CONTAINING REVERSE CURRENT DIODE.RT AMMETER INDICATION WAS INTERMITTANTLY LOST. FURTHER INVESTIGATION FOUND THE LOADApr 11, 2000 · Beech B90SDR HEEA065219Indicator · reads highAMMETER READS 50 AMPS HIGHER.Nov 17, 1999 · N5010F · Bell 212SDR HEEA065100Dual Ammeter · stickingNR 1 POINTER STICKS.Nov 11, 1999 · N2014K · Bell 412SDR HEEA063368Indicator · failedINDICATOR PEGS OUT DURING OPERATION OF AIRCRAFT. IT ALSO FLUCTUATES.Aug 13, 1999 · Bell 214STSDR HEEA063321Indicator · stickingINDICATOR'S NR 2 NEEDLE STICKS.Aug 12, 1999 · N3897N · Bell 214STSDR 99ZZZX2270Ammeter · mismanufacturedPILOT REPORTS AMMETER INOPERABLE. REMOVED STEWART WARNER 70-AMP METER AND FOUND ONE POST SHORTED TO THE MOUNT TRAY WHERE IT PASSES THROUGH MOUNT HOLE. IT MELTED THE TRAY IN THE AREA OF CONTACT. INSTALLED NEW ROCHESTER 70-AMP GAUGE PER PIPER KIT 765-186V ANDMay 4, 1999 · N46UT · Piper PA28R200SDR AU990009Warning System · activated(AUS) ON INITIAL CLIMB, BOTH MAIN AND AUXILIARY BATTERY WARNING LIGHTS ILLUMINATED ON THE CENTRAL WARNING PANEL.Jan 9, 1999 · Dhav DHC8102SDR HEEA0016402Dual Ammeter · stickingDUAL AMMETER NEEDLE STICKING.Oct 23, 1998 · N5736J · Bell 212SDR HAIGJQR0219Dual Ammeter · malfunctionedPILOT REPORTS THAT NR 1 NEEDLE HANGS UP INTERMITTENTLY ON AMMETER. REPLACED WITH NEW PART.Aug 31, 1998 · N98W · Bell 212SDR HEEA0015723Ammeter · damagedAMMETER HAS INSULATOR CRACKED AND NEEDLE IS ERRATIC.Aug 20, 1998 · N3520T · Bolkms BO105SSDR AU981047Bulb · failed(AUS) AIRCRAFT SUFFERED A COMPLETE ELECTRICAL FAILURE. INVESTIGATION FOUND THAT THE ALTERNATOR WARNING LIGHT BULB HAD BLOWN.Aug 11, 1998 · Cessna R182SDR HEEA0015466Indicator · failedNR 1 INDICATOR ON DUAL AMMETER WILL NOT READ.Jul 30, 1998 · N22608 · Bell 412SDR 98ZZZX2781Load Meter · failedNEEDLE WILL NOT MOVE AT ALL. REMOVED FROM AIRCRAFT AND SENT FOR REPAIR.Jun 29, 1998 · N206BX · Bell 206BSDR HEEA0014927Dual Ammeter · stickingNR 1 AMMETER STICKS AT FULL RANGE AND NR 2 READS HIGH.Jun 22, 1998 · Bell 206L1SDR HEEA0014765Indicator · inoperativeDC INDICATOR'S NR 2 NEEDLE DOES NOT INDICATE.Jun 11, 1998 · N3897N · Bell 214STSDR HEEA0014578Dual Ammeter · sticksDUAL AMMETER NR 2 NEEDLE IS STICKING.Jun 4, 1998 · N1079U · Bell 212SDR HEEA0014426Indicator · faultyBATTERY INDICATOR GAUGE HAS INOPERATIVE LCD SEGMENT ON THE Y10 VOLT NUMBER, LT LOWER VERTICAL LCD SEGMENT.Jun 1, 1998 · N467PH · Bell 407SDR HEEA0013606Indicator · stickingINDICATOR HANDS STICKING AND OUT OF TOLERANCE.Mar 26, 1998 · N23023 · Bell 412SDR HEEA0013486Dual Ammeter · failedNR2 NEEDLE WILL NOT INDICATE.Mar 19, 1998 · N22608 · Bell 412SDR HEEA0013283Indicator · defectiveDUAL VOLTAGE INDICATOR READS HIGH ON LOW END.Mar 4, 1998 · N2261D · Bell 412SDR HEEA0012637Indicator · fluctuatesINDICATOR FLUCTUATES.Jan 26, 1998 · N3897N · Bell 214STSDR HEEA0012081Indicator · failedINDICATOR READS 5% HIGH.Nov 19, 1997 · N3897N · Bell 214STSDR 97ZZZX4147Ammeter · mismarkedWHILE REPLACING BAD AMMETER, NOTICED THE MARKINGS FOR PLUS AND MINUS WERE OPPOSITE OF THE ORIGINAL GAUGE. THE AMMETER WAS BENCH CHECKED FOR PROPER DEFLECTION AND IT WAS FOUND MIS-MARKED. WHEN INSTALLED AND HOOKED UP AS THE ORIGINAL GAUGE WAS, OPS CHECK NORMASep 9, 1997 · N6621A · Cessna T210NSDR REXA97185Connector · dirtyIN-FLIGHT, BOTH AMMETERS DROPPED TO ZERO. CLEANED CONNECTORS TO BOTH SHUNTS, OPS CHECK GOOD. (X)Jul 1, 1997 · N308PX · Bag JETSTM3101SDR C2XA97CL060Switch · wire brokenCLE - FLT 3251 - CREW REPORTED THAT THE LEFT GENERATOR VOLTAGE SELECT INDICATOR READS 'O' VOLTS WHEN GENERATOR IS ON LINE. AIRCRAFT RETURNED TO FIELD. MAINTENANCE INSPECTED THE AIRCRAFT AND THEN REPAIRED A BROKEN WIRE ON THE MAIN VOLTAGE SWITCH IAW B1900 MM Jun 20, 1997 · N82539 · Beech 1900DSDR JZBR14058Amplifier · failedCREW REPORTED NR 2 BATT AMPMETER FROZE AT 32 AMPS. TROUBLESHOOTING REVEALED THE BATTERY MONITOR AMP AT FAULT. REMOVED AND REPLACED THE AMPLIFIER WITH A SERVICEABLE UNIT. PERFORMED A FUNCTIONAL TEST IAW THE MM AND ALL WAS GOOD. THE FOLLOWING DAY MAINTENANCEMar 29, 1997 · N711RL · Gulstm G1159SDR HEEA978882Indicator · sticksNEEDLE ON AIRCRAFT SIDE INTERMITTENTLY STICKS.Jan 14, 1997 · N22608 · Bell 412SDR 96ZZZX5943Switch · malfunctionLEFT HAND GENERATOR APPEARED TO CARRY ONLY 60 AMP LOAD. TROUBLESHOT TO AN INDICATION ERROR. FOUND BAT/GEN SWITCH TO CAUSE LEFT GENERATOR AMMETER INDICATION ERROR. INSTALLED NEW SWITCH OPERATIONAL TEST GOOD. THIS IS THE SECOND TIME THIS FACILITY HAS FOUND TNov 19, 1996 · N35TK · Cessna 425SDR HEEA968101Indicator · sticksNEEDLE ON DC SIDE INTERMITTENTLY STICKS. TIME SINCE REPAIR 186:45.Oct 3, 1996 · N2261D · Bell 412SDR 96ZZZX4967Ammeter · mismarkedAMMETER FOR PROPELLER DEICE SYSTEM, PIPER PN 548-084, APPEARS MIS-MARKED. OLD UNIT GREEN ARC IS FROM 20-24 AMPS. NEW UNIT MARKED 17-24 AMPS. NORMAL DRAW ON SYSTEM IS 17-18 AMPS. OLD METER SHOWS 17 AMPS, BUT THAT IS BELOW GREEN ARC, WHICH CAUSES PILOTS TO SSep 10, 1996SDR 96ZZZX4711Shunt · brokenMOUNTING BASE OF AMMETER SHUNT BROKE UP AROUND THE 2 MOUNTING SCREWS ALLOWING THE SHUNT TO MOVE ABOUT. THE BASE OF THE MOUNT IS HOLLOW EXPOSING THE SCREWS THAT HOLD THE TERMINAL BLOCKS TO THE BASE. THESE SCREWS CONTACTED THE BASE MOUNTING SCREWS ARCING TO GRAug 27, 1996 · N40CK · Beech B90SDR HEEA967525Dual Ammeter · fluctuates#1 NEEDLE FLUCTUATES WHEN VIBRATED & INTERMITTENTLY STICKS AT ZERO. TIME SINCE REPAIR 29:35.Jul 5, 1996 · N7128R · Bell 412SDR MALA964948Bus Light · flickersYNG - FLT 3367 - ON APPROACH THE RIGHT NON-ESSENTIAL BUS LIGHTS BEGAN TO FLICKER AND THE CREW NOTED AN ELECTRICAL SMELL. MAINTENANCE DEFERRED THE SYSTEM PER MEL 33-1C. (X)Apr 11, 1996 · N428MA · Swrngn SA227ACSDR 96ZZZX1707Ammeter · seizedAMMETER NEEDLE FROZEN. WOULD NOT SHOW ANY SIGN OF CHARGE OR DISCHARGE. NO LOW VOLTAGE INDICATOR ON 172M. 1975 MODEL SKYHAWK.Mar 20, 1996 · N64262 · Cessna 172MSDR VTZA96118Ammeter · failedFLT NR 6444 - BOS-IAD - DURING CLIMB-OUT, RETURNED TO BOS DUE TO THE RIGHT AMMETER INDICATING 700 AMPS. AIRCRAFT LANDED AT BOS WITH NO FURTHER INCIDENTS. MAINTENANCE REPLACED THE RIGHT AMMETER. AIRCRAFT WAS RELEASED AND APPROVED FOR RETURN TO SERVICE. (M)Mar 15, 1996 · N302UE · Jetair JETSTM4101SDR CA960311012Ammeter · burned out(CAN)DURING TROUBLESHOOTING OF THE INSTRUMENT LIGHT SWITCH, WITH THE MASTER SWITCH ON SMOKE WAS NOTED IN THE CABIN. THE MASTER WAS SHUT OFF. FLAME WAS NOTED UNDER THE RIGHT SIDE OF THE INSTRUMENT PANEL ANDTHE FIRE EXTINGUISHER WAS DISCHARGED INTO THE FIRE. INVFeb 29, 1996 · Cessna 150LSDR 96ZZZX5240Ammeter · wrong partPIPER PARTS CATALOG HAS NOT YET BEEN UPDATED TO REFLECT AMMETER REPLACEMENT IAW AD 86-17-01. PARTS SUPPLIERS ARE USING OLD FICHE TO SEND OUT OLD STYLE AMMETERS WHICH DO NOT COMPLY WITH PREVIOUSLY STATED AD. IN THE EVENT ONE OF THESE OLD STYLE AMMETERS IS INSFeb 25, 1996 · N33156 · Piper PA34200TSDR CA960311020Ammeter · failed(CAN)BATTERY FAILURE AS IN SDR 960311021 WAS NOT INDICATED BY THE AMMETER.Feb 22, 1996 · Piper PA30SDR 96ZZZX470Ammeter · shortedFLT 702 - SHORTLY AFTER TAKEOFF FROM THE AIRPORT, THE AMMETER SHORTED CAUSING SMOKE TO FILL THE COCKPIT. THE PIC WAS ABLE TO RETURN TO AIRPORT SAFELY.Dec 3, 1995 · N8991N · Piper PA32300SDR 96ZZZX702Ammeter · defectiveTHREE DEFECTIVE AMMETERS RECEIVED. FIRST TWO HAD NEEDLE STUCK (JAMMED BY GAUGE FACE) AT 20 PERCENT LEFT DEFLECTION. THIRD UNIT HAD NEEDLE OUT-OF-CALIBRATION (NOT STUCK) 10 PERCENT TO THE RIGHT. ALL MADE BY (NON-PMA'S) AND SOLD THROUGH PIPER FACTORY.Nov 15, 1995 · Piper PA31350SDR S2YA950015Volt/Ammeter · stickingMKE - FLT 1091.1 - AFTER FLIGHT CREW TOOK OFF, THEY NOTICED THE D.C. AMMETER STAYED AT ABOUT 60 AMPS. THEY DECIDED TO TURN BACK TO MKE TO HAVE MAINTENANCE CHECK IT. MAINTENANCE DETERMINED IT WAS A STICKING GAUGE MOVEMENT. VOLT/AMMETER WAS REPLACED. (X)Jul 7, 1995 · N87SK · Beech 1900D
Back to JASC 2437