JASC 2530

Service difficulty reports · 4,468

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR GTIA2025011638677Table · damagedG 1 GALLY WORK DECK REQUIRES REPLACEMENT RAF-01 3292704-01 GENERATED-TEMPORARY LIFE LIMMITED REPAIR OF GALLEY G1 WORKDECK TOP METALIC SKIN CRAKED COMPLIED WITH IAW EA 2530-2501Jan 21, 2025 · N619NK · Airbus A320232SDR GTIA2025011638676Table · damagedINSIDE CABIN G4 GALLEY WORKDECK IS DELAMINATED -REMOVED AND REPLACED G4 GALLEY WORKDECK KIT 263422-50011 IAW REF TR 2533-015 RAF -01 GENERATED 3292706-02Jan 21, 2025 · N619NK · Airbus A320232SDR CALA2025012101950Oven · dirtyFLIGHT ATTENDANT REPORTED AN ELECTRICAL ODOR THAT LASTED MOMEN TARILY IN AFT CABIN PER FLIGHT CREW, ODOR WAS NOT ELEC. ODOR AND WAS IN AFT CABIN/ A FT GALLEY. ODOR HAPPENED HALFWAY THROUGH FLIGHT AND WAS MOMENTAR Y. SMELL WENT AWAY AFTER SHUTTING OFF OVENS. IJan 20, 2025 · N47282 · Boeing 7378SDR DALA2025012000456Block · corrodedSHIP 3147 THE TROLLEY RETAINER BLOCKS WERE FOUND CORROED AT COMPARTMENTS 109, 110, 11 & 112 RESPECTIVELY OF THE GALLEY G1. CORRECTIVE ACTION: COMPLIED WITH ER/A #622514-14. (0769731)Jan 20, 2025 · N347NB · Airbus A319114SDR DALA2025012000455Retainer · corrodedSHIP 3147 THE TROLLEY RETAINER WERE FOUND CORROED AT COMPARTMENTS 109, 110, 11 & 112 RESPECTIVELY ON THE GALLEY G1 AT FWD GALLEY AREA. CORRECTIVE ACTION: COMPLIED WITH ER/A #622514-14. (0767678)Jan 18, 2025 · N347NB · Airbus A319114SDR J7SA2025020700431Microwave Oven · faultedBURNING WIRE SMELL WHEN MICROWAVE OVEN IS IN USE. TESTED ON GROUND AFTER FLIGHT, SMALL AMOUNT OF SMOKE PRESENT. REPLACED DYNAMO MICROWAVE IAW G650 AMM 25-37-02. OPS CHECK GOOD.Jan 17, 2025 · N667FX · Gulstm GVISDR QXEA2025011700008Oven · smokeFLIGHT 2080. AT 33,000FT IN CRUISE THE AFT FA REPORTED EXCESSIVE SMOKE FROM THE REAR OVEN. REMOVED FROM SERVICE. DEACTIUVATED OVEN AND PLACED ON NEF 1112642 WITH A 300 HOUR LIMIT. AIRCRAFT RETURNED TO SERVICE.Jan 14, 2025 · N651QX · Emb ERJ170200LRSDR AALA202501174081Oven · odorAIRCRAFT WAS NOT GROUNDED: REPEAT WRITE UP. STRONG BURNING SMELL FROM OVEN NUMBER 2. FLIGHT ATTENDANTS REPORT EYE IRRITATION FROM THE FUMES GENERATED INSIDE THE OVEN. REMOVED AND REPLACED NUMBER 2 OVEN. PER AMM 25-32-03.Jan 12, 2025 · N344TS · Boeing 737823SDR AALA202501134081Oven · odorAIRCRAFT WAS NOT GROUNDED: REPEAT WRITE UP. STRONG BURNING SMELL FROM OVEN NUMBER 2. FLIGHT ATTENDANTS REPORT EYE IRRITATION FROM THE FUMES GENERATED INSIDE THE OVEN. (OPEN).Jan 12, 2025 · N344TS · Boeing 737823SDR DALA2025011300245Retainer · corrodedSHIP 3147 CORROSION GALLEY 5 LOWER SKIN ON TROLLEY RETAINER BLOCK COMPARTMENT ON COMPARTMENT 512 AT AFT GALLEY AREA. CORRECTIVE ACTION: COMPIED WITH ER/A 622347-14. (0757765)Jan 12, 2025 · N347NB · Airbus A319114SDR CALA2025011301870Coffeemaker · unsecureCM420 UNLOCKED, SLIDING OFF THE RAIL. FOUND COFFEE MAKER 420 UNLOCKED AND SLIDING ON THE RAIL. RESECURED COFFEE MAKER 420. OPS CK GOOD REF AMM 25-32-33.Jan 11, 2025 · N17349 · Boeing 7378SDR SWIA202501100006Oven · smokeD: SMALL AMOUNT OF SMOKE FROM THE AFT OVEN. INSPECTED AFT OVEN AND FOUND A SMALL AMOUNT OF GREASE IN THE BACK OF THE OVEN. CLEANED THE OVENC: NEF-GAL-7CAT: 'C' DUE 1/16/25*ODI* DIVERTED TO PDX. REQUIRES MOD APPROVAL PRIOR TO RTS (FLIGHT 3428 - FILED CLOSED)Jan 6, 2025 · N404SY · Emb ERJ170200LRSDR SWIA2025010700006Oven · smokeD: SMALL AMOUNT OF SMOKE FROM THE AFT OVEN. INSPECTED AFT OVEN AND FOUND A SMALL AMOUNT OF GREASE IN THE BACK OF THE OVEN. CLEANED THE OVENC: NEF-GAL-7CAT: 'C' DUE 1/16/25*ODI* DIVERTED TO PDX. REQUIRES MOD APPROVAL PRIOR TO RTS (FLIGHT 3428 - FILED OPEN) Jan 6, 2025 · N404SY · Emb ERJ170200LRSDR GTIA2025010738654Coffeemaker · odorBURNING SMELL IN FORWARD GALLEY WHEN COFFEE MAKER TURNED ON.-REF. TSM 24-00-00-810-823-A AND 05-50-00-810-831-A. FOUND NO DAMAGE TO ELEC. CIRCUITS IAW TSM 24-00-00-810-823-A STEP 4(B). FOUND CAUSE OF ODOR TO BE TYPE 10 ON DECISION TABLE IAW TSM 05-50-00810-831Jan 5, 2025 · N662NK · Airbus A321231SDR AALA202501064224Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT CREW REPORTED THAT OVEN #2 IS PRODUCING STRONG CHEMICAL ODOR ON DESCENT NEAR 10,000 FT. MAINTENANCE REPLACED THE OVEN PER AMM 25-35-19.Jan 5, 2025 · N189UW · Airbus A321211SDR AALA202501066056Coffeemaker · burnedAIRCRAFT WAS NOT GROUNDED: AT CRUISE, FLIGHT ATTADNENT REPORTED BURNING SMELL AFTER GALLEY. CAPTAIN VERIFIED VERY STRONG ELECTRICAL BURNING SMELL PRESENT STARTING AT ROW 30. REMOVED AND REPLACED BOTH COFFEE MAKERS (AALA202501066056), (AALA202501065717) IN AFT Jan 4, 2025 · N949NN · Boeing 737823SDR AALA202501065717Coffeemaker · burnedAIRCRAFT WAS NOT GROUNDED: AT CRUISE, FLIGHT ATTADNENT REPORTED BURNING SMELL AFTER GALLEY. CAPTAIN VERIFIED VERY STRONG ELECTRICAL BURNING SMELL PRESENT STARTING AT ROW 30. REMOVED AND REPLACED BOTH COFFEE MAKERS (AALA202501066056), (AALA202501065717) IN AFT Jan 4, 2025 · N949NN · Boeing 737823SDR AALA202501069299Oven · inoperativeAIRCRAFT WAS NOT GROUNDED: A SMELL COMING FROM FORWARD GALLEY OVEN NUMBER 2, SOF IS CONFIRMED AND IS ALSO INOPERATIVE.REMOVE AND REPLACED FORWARD GALLEY OVEN NUMBER 2. OPERATIONAL CHECK GOOD. PER AMM 25-32-03.Jan 3, 2025 · N913AN · Boeing 737823SDR DALA2025010300065Coffeemaker · odorAIRCRAFT 3011, SHORTLY AFTER TOP OF CLIMB FA ALERTED US TO A METALLIC POSSIBLY ELECTRIC SMELL AT REAR OF AIRCRAFT. F/AS PULLED BREAKERS AT BACK, AND PILOTS DISCONNECTED GALLEY AND CABIN SWITCH IN FLIGHT DECK. ODOR DISSIPATED AND ELECTED TO CONTINUE FLIGHT. CORJan 3, 2025 · N311DN · Airbus A321213SDR DXTA2025010801810Microwave Oven · failedDURING A 6 HR FLT AFTER SEVERAL NORMAL USES OF THE MICROWAVE, OWNER TRIED TO COOK A BAG OF POPCORN. SHORTLY AFTER STARTING THE COOKING SMOKE STARTED POURING OUT OF THE MICROWAVE. THE ARCFT FILLED WITH SMOKE LIGHTLY. MICROWAVE WAS STOPPED. ALL AIR VENTS IN THEJan 2, 2025 · N840QS · Textrn TEXTRON700SDR CALA2025010601782Oven · dirtyCREW REPORTING ONE OF THE TRASH BIN TEMP SENSOR OF EITHER OF THE AFT 2 LAVS INDICATES A GREY DOT ABOVE 200 F. FOR THE AFT 2 LAVS, PERFORM INSPECTION OF THE TEMP STRIP INDICATORS REF AMM 26-24-01-702, CONFIRM THAT THE FIRE EXT BOTTLE FUSIBLE TIPS HAVE NOT MELTEJan 2, 2025 · N18119 · Boeing 757224SDR AALA202501035825Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN NUMBER 1 IS A BIT SMOKEY WHEN USED. MAINTENANCE VERIFIED OVEN HAD A BURNT PLASTIC SMELL AND REPLACED IT PER AMM 25-32-03.Dec 30, 2024 · N973AN · Boeing 737823SDR CALA2024123001721Chiller · faultedPOPPING NOISE CB PANEL AFT GALLEY TURNED IT OFF SMELL OF BURNING RUBBER CREW STATED SOURCE IS CHILLER CONTROL 401, 402. DEFER AFT GALLEY CHILLER C41 INOP IAW NEF 2522AG. PULL & COLLARED C/B INOP STICKER APPLIED. TOMC APPROVES NEF 2522AG. LOCAL FBO VERIFIED Dec 28, 2024 · N459UA · Airbus A320232SDR AALA202412295455Light · hotAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO PHX DUE TO THE FLIGHT ATTENDANTS REPORTING A SMELL OF BURNING PLASTIC PREDOMINATELY IN REAR OF AIRCRAFT. THE AIRCRAFT LANDED SAFELY AT PHX WITHOUT FURTHER INCIDENT. MAINTENANCE INSPEDec 28, 2024 · N336TM · Boeing 737823SDR DALA2024122712018Coffeemaker · odorAIRCRAFT 3943, AFT FLIGHT ATTENDANTS REPORTED SMELL OF ELECTRICAL SMOKE IN AFT CABIN THAT DISSIPATED QUICKLY. CORRECTIVE ACTION: FOUND WIRE BURNT ON #2 AFT COFFEE MAKER TO THE WARMER PAD. DEFERRED TO NEF 25-36-02. LATER, REPLACED COFFEE MAKER. (LP 6549884, 654Dec 25, 2024 · N943DZ · Boeing 7379GPERSDR AALA202412242957Oven · burnedAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY RIGHT OVEN WAS OVERHEATING AND GIVING OFF A STRONG BURNING SMELL. REMOVED AND REPLACED FORWARD GALLEY NUMBER 2 OVEN. PER AMM 25-32-03.Dec 23, 2024 · N921AN · Boeing 737823SDR AALA202412233849Seal · meltedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: ODOR OF SMOKE THROUGHOUT CABIN DURING CRUISE; AIRCRAFT DIVERTED TO AND LANDED SAFELY AT CLT. ACCOMPLISHED JOB CARD 08L00021001 INITIAL TROUBLESHOOTING. UPON INSPECTION OF FORWARD GALLEY EQUIPMENT FOUND ADec 22, 2024 · N813NN · Boeing 737823SDR DALA2024122311941Oven · odor(LOG 6405226) FA REPORTS ELECTRICAL BURNING SMELL AFTER RESETTING WIFI ENROUTE NEAR FA FRONT CLOSET. NO SMOKE VISIBLE AND SMELL DISSIPATED 5 MINUTES AFTER. R/R FWD GALLEY OVEN REF B737 AMM 25-31. OPS CK GOOD. NO SMELL.Dec 21, 2024 · N848DN · Boeing 737932ERSDR DALA2024122311915Table · damagedSHIP 3121 AFT GALLEY COMPARTMENT 512 WORK TOP LOWER SKIN AREA OF DELAMINATION AT BOTH TROLLEY BLOCK AREAS. CORRECTIVE ACTION: DAMAGE HAS BEEN REPAIRED IAW ER/A 623096-14AD. (0721410)Dec 21, 2024 · N321NB · Airbus A319114SDR DALA2024122311914Table · damagedSHIP 3121 AFT GALLEY COMPARTMENT 511 WORKTOP LOWER SKIN BULGED. CORRECTIVE ACTION: DAMAGE HAS BEEN REPAIRED IAW ER/A 623096-14AD. (0721405)Dec 21, 2024 · N321NB · Airbus A319114SDR DALA2024122311913Table · damagedSHIP 3121 AFT GALLEY COMPARTMENT 511 WORKTOP LOWER SKIN AREA OF DELAMINTION AT OUTBD TROLLEY BLOCK AREA. CORRECTIVE ACTION: DAMAGE HAS BEEN REPAIRED IAW ER/A 623096-14AD. (0721402)Dec 21, 2024 · N321NB · Airbus A319114SDR DALA2024122311912Table · damagedSHIP 3121 AFT GALLEY COMPARTMENT 511 WORKTOP LOWER SKIN AREA OF DELAMINTION AT INBD TROLLEY BLOCK AREA. CORRECTIVE ACTION: DAMAGE HAS BEEN REPAIRED IAW ER/A 623096-14AD. (0721401)Dec 21, 2024 · N321NB · Airbus A319114SDR DALA2024122311911Table · damagedSHIP 3145 CORROSION FWD GALLEY COMPARTMENT G1 WORKDECK LOWER SKIN TROLLEY RETAINER AREA. CORRECTIVE ACTION: REPAIRED PER ER/A # 622139-14. (0721958)Dec 21, 2024 · N345NB · Airbus A319114SDR DALA2024122311910Retainer · damagedSHIP 3145 DAMAGES WERE FOUND IN LOWER SKIN TROLLEY RETAINER BLOCKS COMPARTMENT IN GALLEY 1. CORRECTIVE ACTION: COMPLIED WITH ER/A # 622139-14. (0721884)Dec 21, 2024 · N345NB · Airbus A319114SDR QXEA2024122300321Oven · dirtyFLIGHT 2116. BURNING SMELL COMING FROM G2 OVEN WHILE IN USE REMOVED FROM SERVICE. CLEANED G2 OVEN AS REQUIRED, NOTED REMAINS OF BURNT FOOD. OPS CHECK GOOD REF E175 AMM TASK 25-37-02-720-802-A. RETURNED TO SERVICE.Dec 21, 2024 · N637QX · Emb ERJ170200LRSDR DALA2024122011862Retainer · corrodedSHIP 3145 CORROSION LOWER SKIN TROLLEY RETAINER BLOCKS COMPARTMENT 109 , 110; 111 AND 112 GALLEY 1, FWD GALLEY AREA. CORRECTIVE ACTION: COMPLIED WITH ER/A 622139-14. (0718988)Dec 19, 2024 · N345NB · Airbus A319114SDR AALA202412264004Oven · dirtyAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS NOT DECLARED DUE TO: WARMING COMPARTMENT NUMBER 1 IN FIRST CLASS GALLEY HAS A BURNING PLASTIC SMELL, OVEN WOULD NOT SHUTOFF WITHOUT PULLING C/B; AIRCRAFT DIVERTED TO AND LANDED SAFELY AT JFK. **SUPPLEMENTAL REPORT FOR (ADec 18, 2024 · N794AN · Boeing 777223SDR AALA202412194004Oven · odorAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS NOT DECLARED DUE TO: WARMING COMPARTMENT NUMBER 1 IN FIRST CLASS GALLEY HAS A BURNING PLASTIC SMELL, AIRCRAFT DIVERTED TO AND LANDED SAFELY AT JFK. **SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).Dec 18, 2024 · N794AN · Boeing 777223SDR CALA2024121901574Oven · faultyOVEN 411 VERY DIRTY, HAS PLASTIC BURNING SMELL. REQUEST NEF FOR OVEN 411 IN AFT GALLEY. NOC DESK: 757 NAME: DATE: 17-DEC-24- APPROVED PLACED ON NEF. FOUND EXCESSIVE AMOUNTS OF FOOD DEBRIS BURNT ON TO THE BOTTOM BACK OF THE OVEN AND ON THE OVEN SHELF TRAY Dec 17, 2024 · N77871 · Boeing 75733NSDR CALA2024121601520Unknown · odorCAN NOT GET SMELL OUT OF AFT GALLEY F.A.S ARE WEARING MASKS AND NAUSEOUS FOUND ODOR TO BE STRONGEST NEAR THE R2 DOOR. FOLLOWED CLEANING CREW AND CLEANED AREA AND SPRAYED DEODORIZING AGENT. IAW AMM 25-00-00.Dec 14, 2024 · N17294 · Boeing 7378SDR CALA2024121601519Oven · fodCREW REPORTING BURNING SMELL IN AFT GALLEY AREA. DEACTIVATED OVENS AND COFFEE MAKERS IN AFT GALLEY. ELECTRICAL SMELL DID NOT DISSIPATE. ELECTRICAL SMELL ISOLATED TO AFT GALLEY / LAVATORY AREA. REACTIVATED AFT GALLEY OVENS AND COFFEE MAKERS AND PERFORMED OPS Dec 13, 2024 · N77571 · Boeing 7379SDR DALA2024121111618Coffeemaker · odorSHIP 3223 - DIV - TO BIS DUE TO A BURNING RUBBER SMELL IN THE AFT GALLEY. CORRECTIVE ACTION: FOUND BOTH AFT COFFEE MAKERS WITH BURNT COFFEE ON THE HEATING PADS. REPLACED ONE AND DEFERRED THE OTHER. (LP: 6527794)Dec 9, 2024 · N323US · Airbus A320211SDR DALA2024121011568Coffeemaker · odor(LOG 6502348) FA'S REPORTED HOT PLASTIC SMELL IN FWD GALLEY CIRCUIT BREAKERS PULLED SMELL DISSIPATED. R/R FWD GALLEY C/M PER B737 AMM 25-31. OPS CHK GOOD.Dec 9, 2024 · N832DN · Boeing 737932ERSDR CALA2024121001462Oven · odorLT SMOKE AND BURNING ODOR OBSERVED IN FLT IN AREA OF AFT GALLEY OVENS STOPPED WHEN CBS PULLED. PERFORMED CONDITIONAL INSPECTION OF AFTER GALLEY REF AMM 05-51-26-800-801-C1, FOUND SMOKE/ODOR COMING FROM INSIDE OF #2 ODOR. AFTER REMOVED FOOD TRAY AND CLEANED OVDec 8, 2024 · N16701 · Boeing 737724SDR AALA202412098366Oven · fodAIRCRAFT WAS NOT GROUNDED: LEFT OVEN SMELLS STRONGLY OF BURNING PLASTIC. REMOVED AND REPLACED FORWARD GALLEY NUMBER 1 OVEN. OPERTIONAL CHECK GOOD NO MORE SMELL. PER AMM 25-33-00.Dec 8, 2024 · N905AN · Boeing 737823SDR AALA202412098105Coffeemaker · odorAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED INBOUND TO DFW DUE TO THE FLIGHT CREW REPORTING AT APPROXIMATELY 5000 FEET ON THE DESCENT INTO DFW THERE WAS A STRONG ELECTRICAL BURNING SMELL IN THE FORWARD GALLEY REPORTED BY THE FLIGHT ATTENDANT IN THE FORWARDec 6, 2024 · N115NN · Airbus A321231SDR CALA2024120303013Coffeemaker · inoperativeSTRONG ELECTRICAL SMELL FORWARD GALLEY DURING DESCENT. POSSIBLE ELECTRICAL FAILURE IN FWD GALLEY. AN ELECTRICAL ODORS SMELL. REMOVED AND REPLACED #1 COFFEE MAKER THAT STOPPED WORKING. WHICH POSSIBLE CAUSED THE SMELL. OPS CHK GOOD OK TO CONTINUE.Dec 3, 2024 · N17139 · Boeing 757224SDR DALA2024120611509Coffeemaker · odorELECTRICAL/PLASTIC SMELL IN AFT GALLEY CABIN AREA. CONTINUEING T/S FOUND AFT GALLEY R/H GAIN2 COFFEE MAKER CAUSING ELEC BURNING SMELL. DEACTIVATED GAIN2 COFFEE MAKER AND TURN ON ALL COFFEE MAKER, OVEN, AND CHILLER NO SIGNS OF ELEC BURNING SMELL WITH BOTH PACK Dec 2, 2024 · N507DN · Airbus A350941SDR DALA2024120211363Panel · abnormalF. A REPORTED A BURNING PLASTIC SMELL IN THE AFT GALLERY AREA. PERFORMED ODI INSPECTION IN THE AFT GALLEY AREA OVERHEAD PANEL, OVEN, COFFEE MAKER, CHILLER NO FOUND DEFECT NO SMELL. (LP# 6445370)Dec 1, 2024 · N507DN · Airbus A350941SDR CALA2024112901348Chiller · malfunctionedAFT CHILLER OR CHILLERS MOTORS PULSATE ON/OFF. FA SMELLED ELECTR ICAL FA SMELL ELECTRIC BURN. OPERATED BOTH AFT GALLEY CHILLERS AND OPERATED NORMALLY. FOUND NO EVIDENCE OF ANY ELECTRICAL BURNING OR ODORS. ONLY SOURCE OF SMELL WAS A SMALL AMOUNT OF COFFEE ON A Nov 27, 2024 · N832UA · Airbus A319131
Back to JASC 2530