Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2024112611237Oven · odorAIRCRAFT 3097, IN DESCENT PASSING 7,000 FT, STARTED GETTING ELECTRICAL SMELL. GOT SLIGHTLY BETTER AFTER LANDING. SMELL IN CABIN AND COCKPIT. CORRECTIVE ACTION: FOUND ELECTRICAL SMELL COMING FROM THE RT OVEN IN THE FWD GALLEY. REPLACED OVEN IAW A321 AMM 25-35. SDR CALA2024112601291Oven · smokeAFT LEFT OVEN SET OFF 4R LAV SMOKE ALARM WHEN USED. FA REPORTED ELEC SMELL FA REPORTS WHEN THE DOOR ON AFT OVEN #3 WAS OPENED SOMETHING ACTIVATED THE LAV SMOKE DETECTOR LAV DOOR WAS OPEN AND STOPPED WHEN OVEN DOOR WAS SHUT NO TIME TO TS REQUEST NEF NOCDESK: 75SDR AALA202411252195Coffeemaker · shortedAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORTED AN ELECTRICAL BURNING SMELL IN AFT GALLEY, THEY TURNED OFF BOTH COFFEE POTS AND SAID SMELL WENT AWAY.NO SMOKE WAS SEEN, AND IT WAS A FAINT SMELL, BUT ALL 4 FA'S AGREED THEY SMELLED THE SAME SMELL. PERFORMEDSDR AALA202411250709Coffeemaker · shortedAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORTED AN ELECTRICAL BURNING SMELL IN AFT GALLEY, THEY TURNED OFF BOTH COFFEE POTS AND SAID SMELL WENT AWAY.NO SMOKE WAS SEEN, AND IT WAS A FAINT SMELL, BUT ALL 4 FA'S AGREED THEY SMELLED THE SAME SMELL. PERFORMEDSDR CALA2024112501261Oven · faultyBURNING SMELL AFT GALLEY. SMOKE ODOR FORM UPDATE. FOUND ALL 3 AFT GALLEY OVENS STAINED WITH OILY BURNT SUBSTANCE, REF. PHOTOS. REQUESTING MEL FOR ALL "3" OVENS IN AFT GALLEY TO BE REPLACED. PERFORMED AMM 05-51-58-910-801-C1 FOUND THE "3" OVENS IN THE AFT GALLSDR SWAA2024121769906Galley · corrodedG-4 GALLEY COUNTERTOP HAS CORROSION.<[01] PART TRANSACTION ONLY; G-4 GALLEY INSTALLATION REF TASK CARD FOR JOB ACCOMPLISHMENT TTG8Q003E0PW;[02] VERIFIED PART TRANSACTIONSDR CALA2024112101229Oven · faultyREF TO LOG PAGE 9915110, FAINT ELECTRICAL SMELL/FUME FROM FWD GALLEY LEFT SIDE. FOUND BURNED PLASTIC RESIDUE ON OVEN EXHAUST EXHAUST FAN FWD GALLEY LOCATION 207. FWD GALLEY REMOVED AND REPLACED GALLEY OVEN 207 REF AMM 25-34-00. OPS CHECKED GOOD. OK FOR SERVISDR AALA202411204703Sill Drain · cloggedAIRCRAFT WAS NOT GROUNDED: SMELL (ROTTEN EGGS) EMANATING FROM AFT CABIN UPON LANDING. FOUND CAUSE OF SMELL IN AFT GALLEY, AFT SILL DRAIN FLOAT VALVE COMPLETELY CLOGGED. REMOVED AND REPLACED AFT SILL DRAIN FLOAT VALVE. PER AMM 38-31-06-400-802. POURED WATER DOWSDR CALA2024111802881Oven · smokeOVEN 107 SMOKE COMING OUT OF OVEN HALON EXTINGUISHER USED FOUND EXCESSIVE BURNT FOOD DEBRIS IN OVEN 107, PLACING OVEN 107 REPLACEMENT, DO NOT CLEAN. COMPLIED WITH NEF. OVEN 107 DEACTIVATED. WILL REQUIRE ON NEF. FOOD DEBRIS ON HEATING ELEMENTS, OVEN WILL REQUIRSDR SCNA20241112363Oven · smokeDEFECT 716986: OVEN # 204 SMOKES WHEN USE FA CLEANED WANTS IT CHECKED.SDR CALA2024111201111Coffeemaker · smokeBOTH COFFEE MAKERS IN THE AFT GALLEY WERE SMOKING DURING T/O AN D CLB. FAS PULLED CBS FOUND SOURCE OF SMOKE , DEBRIS UNDER COFFEE MAKERS HOT PLATES. TEA BAGS ,SUGAR PACKETS STIRRERS, AND PLASTIC REFUGE ALL MELTED AND BURNED. PICTURE UPDATES INSP. AFT. GALLEY SDR SWAA2024111358339Coffeemaker · smokeF/A REPORT ELECTRICAL SMELL IN CABIN. ALL COFFEE MAKER C/B'S PULLED.<[01] RESTORED ALL C/B'S TO NORMAL CONFIGURATION IAW AMM 20-60-01. C/W SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION IAW AMM 05-51-56 AND FIM 21-00 TASK 806. NO DEFECTS NOTED.SDR DALA2024110610698Warmer · damagedAIRCRAFT 5003, ON APPORACH F/A'S CALLED TO REPORT A "DIRTY SOCK " ODOR IN THE FWD PART OF CABIN. NO ODOR WAS OBSERVED ON THE FLIGHT DECK. CORRECTIVE ACTION: FOUND FWD GALLEY BUN WARMER WITH BURNT MARKS AND ODOR. REPLACED FOFRWARD GALLEY BUN WARMER. (LP 6398406SDR DALA2024110810732Access Panel · corroded(LOG 0646198) CORROSION ON COVER PLATE ON ACCESS A423 AT G4. REPLACED PER PRI 621695-14 REV. 0 AND ER/A 621695-14 REV. ORIGINAL.SDR DALA2024110810755Access Panel · corroded(LOG 0646206) WORK SHOP INTERIOR SHEET METAL: CORROSION ON COVER PLATE ON ACCESS A417 AT G4. COVER PLATE ON ACCESS A417 AT G4 WAS REPLACED PRI 621695-14 REV. 0 AND ER/A 621695-14 REV. ORIGINAL.SDR SWAA2024110856884Waste Box · odorFA REPORTED POSSIBLE ODOR THAT RESEMBLED ELECTRICAL<[01] PERFORMED CONDITIONAL INSPECTION PER AMM 05-51-56. NOTICED FOUL SMELL FROM TRASH AREA. NO OTHER DEFECTS NOTED.SDR CALA2024103000966Oven · odorOVEN SMELLS BAD G2 GALLEY OVEN 205 CLEANED G2 GALLEY OVEN 205 REF MM 25-34-00. NO SMELL NOTED.SDR AALA202410284934Oven · odorAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO CLT DUE TO A BURNING PLASTIC ODOR IN FORWARD GALLEY WHICH BEGAN DURING CLIMB AT APPROXIMATLEY 20,000 FT. ODOR DISSIPATED SIGNIFICANTLY WHEN OVENS WERE TURNED OFF BUT SLIGHT ODOR STISDR CALA2024102900953Coffeemaker · odorWATER SUPPLY IN GALLEY SMELLS BAD G1 GALLEY COFFEE MAKER 106 DRAINED, RINSED, AND REFILLED WATER TANK WITH FRESH WATER. BREWED A POT OF HOT WATER IN C/M 106. NO ABNORMAL SMELLS NOTED.SDR CALA2024102900950Oven · odorFA REPORTS AIR FROM FWD GALLEY GASPER VENT HAS BURNT FOOD ODOR GALLEY GASPER VENT SMELLS NORMAL. APC OVEN BURNOUT AND REMAINING ODORS GONE.SDR CALA2024102400921Coffeemaker · unsecureCOFFEE MAKER 106 FOUND UNLOCKED/UNSECURED RESECURED AND LOCKED CM106 REF AMM 25-34-00. OPS CK GOOD.SDR SCNA20241114365Coffeemaker · odorDEFECT 698801: FWD GALLEY COFFEEMAKER HAS CHEMICAL SMELL WHEN BREWING COFFEE. RESOLUTION: FLUSHED PORTABLE WATER SYSTEM IAW AMM 12-14-00. PERFORMED OPS CHECKS IAW AMM 38-10-00 NO EVIDENCE OF SMELL, AC OK FOR SEVICE.SDR SCNA20241114364Coffeemaker · odorDEFECT 698800: AFT COFFEE MAKER HAS CHEMICAL SMELL. RESOLUTION: FLUSHED POTABLE WATER SYSTEM IAW AMM 12-14-00. PERFORMED OPS CHECKS IAW AMM 38-10-00. NO EVIDENCE OF CHEMICAL SMELL. A/C OK FOR SERVICE. THIS CLEARS MELSDR AALA202410198351Oven · smokeAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DELARED AND THE AIRCRAFT DIVERTED TO LAS DUE TO THE FLIGHT CREW REPORTING THAT IN FLIGHT THE MID GALLEY OVEN #3 HAD SMOKE AND FLAMES. THE AIRCRAFT LANDED SAFELY AT LAS WHERE IT TAXIED TO THE GATE UNDER ITS OWN POWER. MAISDR AALA202410175118Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN NUMBER 2 STRANGE SMELL REPORTED BY FLIGHT ATTANDENT, CHECKED AND CONFIRMED OVEN 2 SMELLS. REMOVED AND REPLACED OVEN NUMBER 2. PER AMM 25-32-03.SDR AALA202410178351Oven · smokeAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DELARED AND THE AIRCRAFT DIVERTED TO LAS DUE TO THE FLIGHT CREW REPORTING THAT IN FLIGHT THE MID GALLEY OVEN #3 HAD SMOKE AND FLAMES. THE AIRCRAFT LANDED SAFELY AT LAS WHERE IT TAXIED TO THE GATE UNDER ITS OWN POWER. MAISDR CALA2024101700853Circuit Breaker · trippedCB FOR FWD GALLEY COFFEE MAKER POPPED WAS NOT IN USE MAKER NUMBE R 105REMOVED C/M 105 AND C/M 106. INSPECTED VISIBLE WIRING, CONNECTORS, GROUNDS FOR SHORTS OR DEFECTS, NONE NOTED. REMOVED POWER PANEL ASSY IN FWD GALLEY NEXT TO C/MAKERS. INSPECTED WIRING, CONNSDR AWKA2024101501Oven · dirtyWHILE IN CRUISE FLIGHT, THE CABIN AND FLIGHT CREW SAW AND SMELLED SMOKE COMING FROM THE GALLEY, NUMBER ONE OVEN. THE ASSOCIATED CIRCUIT BREAKER WAS PULLED AND THE SMOKE BEGAN TO DISAPPEAR. SINCE THERE WAS NO LONGER ANY SMOKE IN THE AIRCRAFT, THE CREW DECIDED TSDR DALA2024101210013Oven · odorAIRCRAFT 1014, FA REPORTS FAINT BURNING SMELL FROM FWD GALLEY AIRCRAFT LEFT OVEN. TURNED OFF OVEN AND SMELL DISSIPATED. CORRECTIVE ACTION: FOUND FWD GALLEY OVEN AT LOCATION 104 TO HAVE BURNT METAL ODOR WHEN RUNNING. REPLACED OVEN 104. (LP 6732528)SDR ABXA20241011189Hot Water Pot · odorSMOKE AND BURNED ELECTRONICS COMING FROM HOT POT FULL OF WATER. MTX DEFERRED HOT POT FOR DEPARTURE AND DEACTIVATED IAW ABX-NEF-25-02-02. LATER FOUND AND REPLACED BURNT TERMIANL ENDS IAW B767 SWPM 20-30-11. REMOVED & REPLACED CREW HOT CUP BRACKET IAW B767 AMM SDR GTIA2024101238439Deck Plate · damaged"GALLEY G4 WORKDECK RAF 01-3337210-2 GENERATED -GALLEY G4 WORKDECK REPLACED IAW EC 2533-015"SDR SCNA20241007325Coffeemaker · smokeDEFECT 733921: AFT COFFEE C/B PULLED DUE TO SMOKE. - - RESOLUTION (IN PROGRESS)SDR DALA2024100709758Coffeemaker · smokeSHIP 5033 - ATB - DUE TO SMOKE FROM THE AFT GALLEY COFFEE MAKER. CORRECTIVE ACTION: FOUND COFFEE MAKER AT A507 ELECTRICALLY MALFUNCTIONED CAUSING THE SMELL. REPLACED SAME. OPS CHECK GOOD. (LP 9738518)SDR CALA2024100700763Oven · dirtyMID GALLEY OVEN FIRE. REQUEST NEF OVEN 408 OVEN 408 EMITTED SMOKE, CONFIRMED OVEN 408 FOUND WITH CARAMEL ON HEATING ELEMENT/FAN. PERFORMED CONDITIONAL INSPECTION 05-51-58-800-801-C3. ALL OTHER OVENS / COFFEEMAKERS PERFORMED NORMALLY. NOC OK TO DEFER OVESDR DALA2024100109604Coffeemaker · odorSHIP 3017 - DIV - TO IAD DUE TO BURNING PLASTIC SMELL IN AFT GALLEY. CORRECTIVE ACTION: FOUND BURNT PLASTIC SMELL COMING FROM AFT GALLEY COFFEE MAKERS. DEFERRED AFT GALLEY COFFEE MAKERS PER NEF. OK TO CONTINUE. LATER, REPLACED COFFEEMAKERS. (LP 9992166)SDR FDEA202409291398Floorboard · damagedFLOORBOARD PANEL 222MAF DAMAGED. FABRICATED FLOORBOARD PANEL 222MAF ON MAE TRAVELER T24/1776201 IAW DWG SRZ-25- 005R, MAJOR REPAIR.SDR CALA2024100402565Hose · misinstalledFOUND WATER LEAK IN AFT GALLEY. FROM STATION 887 TO 1016 AND STRINGER 17L TO 17R 887 TO BS 1016 BETWEEN LEFT BUTT LINE (LBL) 64 AND (RIGHT) RBL ARMENTA TOMC 64 AS REQUIRED PER ECRA 2011-01000, GALLEY SPILL, SECTION 2.B. ECRA 2011-0100, GALLEY SPILL, SECTION 2SDR SWAA2024092440324Coffeemaker · odorFLIGHT ATTENDANT REPORTS BURNING PLASTIC COMING FROM AFT COFFEE MAKER 2B<[01] R&R AFT COFFEE MAKER PER AMM 25-32-01. OPS CHECK OK. NO SMELL NOTED.SDR CALA2024092300669Oven · smokeOVEN SMOKING, NEEDS CLEANING 409 OVEN 409 HAS SYRUP SPILL AND SMOKES WHEN ON SMOKE AND ODOUR FILLED IN BY INBOUND CREW, SPILLAGE CONFIRMED. REQUEST NEF 2520AV AS NIL AVAILABLE TIME THIS TURN TO FULLY REMOVE SPILLAGE. CB PULLED AND COLLARED NOC DESK: OM NASDR DALA2024092309293Deck Plate · corrodedSHIP 3148 CORROSION ON LOWER WORK DECK COMPARTMENT 110 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPAIRED PER ER/A 619768-14. (0566989)SDR AALA202409201426Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT CREW REPORTED A STRONG BURNING ODOR EMANATING FROM FIRST CLASS GALLEY OVEN #2. REPLACED OVEN PER AMM 25-35-19.SDR SWIA2024092515Plate · damagedCARGO DOOR FUSELAGE KICK PLATE HAS DAMAGED DOME NUTS (C-CHECK RO 9/24/2024) REPAIRED FUSELAGE SKIN COMMON TO KICKPLATE BELOW CARGO DOOR OPENING LOCATED BETWEEN FS589.00 AND FS621.00, STGR. 17L TO 19L AND REMOVED AND REPLACED DAMAGE DOME NUTS AND DAMAGEDSDR DALA2024091609029Oven · smokeSHIP 3029 - DIV - TO DTW DUE TO FORWARD GALLEY OVEN (LOC. 103) STARTED SMOKING WHEN TURNED ON. OVENS TURNED OFF AND SMOKE DISSIPATED. CORRECTIVE ACTION: R/R OVEN AT LOCATION 103. OPS CHECK GOOD. (LP 5595272)SDR DALA2024091709109Coffeemaker · inoperative(LOG 6117246) FLT ATTENDANT REPORTED THAT WHEN THEY TUNED THE RIGHT AFT GALLEY COFFEE MAKER ON IT STARTED TO SMOKE. THEY TURNED OFF AND IT STOPPED. REPAIRED TERMINAL FOR COFFEE MAKER #1 AT LOCATION A403, R/R COFFEE MAKER AT SAME LOCATION. OPS CHECK NML IAW B73SDR YENA2024091601272Drain Valve · faultedFLT#1537, JFK- STI. (AIRCRAFT PERFORMED AN AIR TURN BACK TO JFK) 'UPON REACHING FL370 INFLIGHT CREW REPORTED EXTREMELY LOUD, HIGH PITCHED NOISE IN THE AFT GALLEY. NOISE DID NOT GO AWAY AS AIRCRAFT DESCENDED UNTIL REACHING ABOUT 5000; FOUND AFT GALLEY WATER DRASDR DALA2024090408719Coffeemaker · odorGALLEY AND LAST 4 ROWS OF CABIN. TURNED OFF GALLEY HEATER/FAN, OVENS AND ELECTRICAL OUTLETS. SMELL DID NOT DISSIPATE. REMOVED SCREWS FOR AFT GALLEY CEILING PANEL(868406) R/R CENTER CEILING PANELS FROM ROW 25 TO AFT GALLEY AND CEILING PANELS IN AFT GALLEY. INSPSDR AALA202409029677Oven · smokeAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN #1, SMOKES WHEN POWER LEVEL ABOVE MEDIUM. STOPS SMOKING WHEN POWER IS REMOVED. MAINETNANCE REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202409100582Chiller · faultedAIRCRAFT WAS GROUNDED: ELECTRICAL ODOR EMITTED IN AFT GALLEY. ODOR NOTICED AFTER HEARING WHAT SOUNDED LIKE A LARGE CHUNK OF ICE MOVE THROUGH THE CHILLER REPORTED BY FLIGHT ATTENDANT. WHILE MAINTENANCE WAS ATTEMPTING TO OPERATE THE AFT GALLEY CHILLER A FAULT MSDR SWAA2024082830176Coffeemaker · odorBURNING SMELL FROM FRONT LEFT COFFEE MAKER<[01] R/R COFFEE MAKER PER AMM 25-30-01.<BR>OPS CHECK GOOD.SDR AALA202408270582Chiller · odorAIRCRAFT WAS GROUNDED: ELECTRICAL ODOR EMITTED IN AFT GALLEY. ODOR NOTICED AFTER HEARING WHAT SOUNDED LIKE A LARGE CHUNK OF ICE MOVE THROUGH THE CHILLER REPORTED BY FLIGHT ATTENDANT. WHILE MAINTENANCE WAS ATTEMPTING TO OPERATE THE AFT GALLEY CHILLER A FAULT M
Back to JASC 2530