Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QXEA2022051700198Galley · inoperativeFLIGHT ATTENDANT B REPORTS SMELL OF BURNING IN AFT INBD COFFEE POT. REMOVED FROM SERVICE. R/R AFT INBOARD COFFEEMAKER IAW E175 AMM 25-37-03-000-801-A/400-801-A OPS CK GOOD IAW E175 AMM 25-37-03-710-801-A PLACARDS ARE REMOVED C/B RESET THIS CLEARS DEFECT 959SDR HALA2022042800162None · noneSHIP 378 MID GALLEY OVENS SMELL ELECTRICAL BURNING. CORRECTIVE ACTION: FLIGHT ATTENDANT SINGLED OUT MID GALLEY OVEN M110. RAN WITH NO FAULTS OR SMELL. PRECAUTIONARY REMOVED AND REPLACE OVEN M110. INSPECTED AND RAN BOTH OVENS. NO SMELLS. CHECKS GOOD. (8462667)SDR DXTA2022042560790None · noneMICROWAVE: THE FLIGHT ATTENDANT HEARD A SIZZLING NOISE, ON THE MICROWAVE, SMELLED AN ELECTRICAL SMELL, THEN POWER WENT OUT ON THE MICROWAVE. AFTER LANDING, AND CHECKING THE VIRTUAL BREAKERS FOR THE GALLEY, THE MICROWAVE SHOWS LOCKED. "CORRECTIVE ACTION" REMOVESDR AALA202204251975Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN NUMBER 2 REQUIRES CLEANING STRONG FOOD ODOR WITH POWER APPLIED. REMOVED AND REPLACED NUMBER 2 GALLEY OVEN IN FIRST CLASS PER AMM 25-32-03.SDR AALA202204257475Oven · smokeAIRCRAFT WAS NOT GROUNDED: NUMBER 2 OVEN OVERHEATS, SMOKES AND HEATS UP. REMOVED AND REPLACED NUMBER 2 OVEN PER AMM 25-32-03.SDR AALA202204219122Oven · odorAIRCRAFT WAS NOT GROUNDED: BOTH OVENS IN FWD GALLEY EMITTED STRONG BURNING ODOR WHEN USED. REMOVED AND REPLACED NUMBER 1 OVEN PER AMM: 25-32-02. REMOVED AND REPLACED NUMBER 2 OVEN (AALA202204212626) PER AMM 25-32-03.SDR AALA202204212626Oven · odorAIRCRAFT WAS NOT GROUNDED: BOTH OVENS IN FWD GALLEY EMITTED STRONG BURNING ODOR WHEN USED. REMOVED AND REPLACED NUMBER 1 OVEN (AALA202204219122) PER AMM: 25-32-02. REMOVED AND REPLACED NUMBER 2 OVEN PER AMM 25-32-03.SDR SIMA202204131002Coffeemaker · smokeTHIS IS A SUPPLEMNETAL C/A FOR FA REPORTS SMOKE/BURN SMELL IN CABIN. EMERGENCY DECLARED. BURNING WIRE SMELL IN AFT GALLEY ON TAKE OFF & MIDFLIGHT.-C/A-FOUND COFFEE MAKER TO BE DEFECTIVE. REMOVED AND REPLACED AND OPC AFT INBOARD COFFEE MAKER IAW EMB175 AMM 25-3SDR AALA202204147578Oven · smokeAIRCRAFT WAS NOT GROUNDED: NUMBER 1 GALLEY OVEN SMOKES BADLY WHEN USED. REMOVED AND REPLACED NUMBER 1 GALLEY OVEN PER AMM 25-33-00.SDR SWIA202265351Oven · smokeD: IN CLIMB OUT REAR FA REPORTED VISIBLE SMOKE FROM REAR OVEN. OVEN TURNED OFF AND SMOKE STOPPED. POSSIBLE GREASE OR LIQUIDS ON BURNER. FA REPORTED THAT IT SMELLED LIKE FOOD BURNING, NOT AN ELECTRICAL OR CHEMICAL SMELL. / C: NEF-GAL-7 / CAT C DUE 4-21-22 / IN SDR AALA202204193496Coffeemaker · leakingAIRCRAFT WAS GROUNDED: INBOUND FLIGHT ATTENDANTS REPORTED STRONG ELECTRICAL ODOR IN THE AFT CABIN WHICH WAS ORIGINALLY NOTICED AT CLT AND BECAME MORE PROMINENT DURING FLIGHT. **SUPPLEMENTAL REPORT FOR AALA202204123496: MAINTENANCE FOUND AFT GALLEY COFFEE MASDR AWKA20220408001Concentrator · smokeWHILE ENROUTE TO DET, FLIGHT CREW WAS ALERTED OF SMOKE IN THE GALLEY AREA. PIC INVESTIGATED AND NOTED THAT IT APPEARED TO BE COMING FROM BEHIND SOME PANELS IN THE CLOSET FORWARD OF THE GALLEY. POWER WAS REMOVED FROM THE CABIN. AN EMERGENCY WAS DECLARED WITH ATSDR DALA2022040402252None · noneSHIP 3312 OVEN IN BACK GALLEY SMOKED ON USE. CAUSED LAV SMOKE DETECTOR. CAUSE ECAM MESSAGE FOR APPROXIMATELY 30 SECONDS SMOKE LAV SMOKE. CORRECTIVE ACTION: REPLACED AFT GALLEY OVEN PER A330 AMM 25-35. (8527422)SDR AALA202204018851Oven · dirtyAIRCRAFT WAS GROUNDED: ELECTRICAL SMOKE SMELL REPORTED FROM CABIN ON CLIMB OUT. RETURNED TO CLO. SMOKE ODOR FUMES INITIAL TROUBLESHOOTING CARD 09L00021001 ACCOMPLISHED. DURING SOF INSPECTION FOUND NUMBER 2 OVEN WITH HEAVY BURNED FOOD REMOVED AND REPLACED NUMBESDR SWAA2022040489398Coffeemaker · smokeSMELL COMING FROM BEHIND COFFEE MAKER ( FWD GALLEY ) / [01] C/W CONDITIONAL INSPECTION PER 05-51-56; VERIFIED SMELL COMING FROM BEHIND THE COFFEE MAKER; NO SMELL NOTED AFTER DE ACTIVATING THE COFFEE MAKER. OK TO CONTINUE PER MEL 25-10-01. SP1B AND SP2;[02] R&RSDR DALA2022032501999Oven · smokeSHIP 3411 SHORTLY AFTER T/O F/A REPORTED ALL AFT OVENS SMOKE/ STEAM. TURNED OFF, COOLED THEN ON AGAIN. L&R AFT OVENS SMOKE/ STEAM AGAIN AFTER 3 MN. 1ST CLASS OVENS ALL OK. OVENS INVOLVED A316, A317, A318, A214, A215, A216, A217. CORRECTIVE ACTION: C/W ODI PREVSDR SIMA20220323002None · noneSMOKE SMELL AROUND LIGHT IN FWD GALLEY-C/A-C/W FIM TASK 25-30-00-810-801-A. NO EVIDENCE OF SMOKE SMELL FOUND. NO DEFECTS OR DAMAGE NOTED. AC GOOD FOR SERVICE.SDR IPXA2022032280353None · noneINSPECTION TYPE:NA**SUPPLEMENTAL SDR** SMELLED FUMES COMING FROM THE GALLEY AREA THEN NOTICE A SLIGHT SMOKEY AIR, TURNED REFRIG SWITCH OFF, PULLED BOTH REFRIG AND HOT POT/OVEN BREAKERS, CALLED FLT CONTROL AND PER MAINT CONTROLL PULLED GALLEY BREAKER, PERFORMEDSDR AALA202203176872Chiller · odorAIRCRAFT WAS GROUNDED: ELECTRICAL SMELL IN FORWARD GALLEY IMPROVED AND WENT AWAY WITH CHILLER OFF. REPLACED CHILLER AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-34-51 WITH NO ODORS NOTED.SDR DALA2022030801504Oven · burnedSHIP 3516 - SMELLED OF PLASTIC OR ELECTRICAL SMOKE. CORRECTIVE ACTION: R/R OVEN FWD GALLEY G1A21 PER A350 AMM 25-36. (3497856)SDR AALA202203078238Coffeemaker · smokeAIRCRAFT WAS NOT GROUNDED: LEFT FRONT GALLEY COFFEE MAKER SMOKING. REPLACED COFFEE MAKER AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK,SDR CALA2022022800526Oven · smokeOVEN/WARMERSMOKING OR SPARKING 708 AFTER 10 MINS OVEN BEGAN 2 SMOKE AND PRODUCE A BA D SMELL INSPECTION C-OUT AS PER DMC-B787-A-05-51-99-99A-282A-A,NO DMC-B787-A-25-32-00-11A-320A-A FOUND SATIS.NO VISIABLE DAMAGE OR PER MEL 2500BR #708 OVEN CB PULL & SAFETY COSDR U5QA202202270103Display · dimSTRONG ELECTRICAL SMELL FROM GALLEY CMS TOUCH SCREEN AREA, DISPLAY NOW ONLY ON DIM MODE. WEST STAR TO R&R DISPLAY, AWAIT PART ARRIVAL AND WO RTS.SDR UIEA2022020400093Oven · fireSMOKE AND SMALL FIRE IN OVEN #7 TRAYS APPEAR TO BE THE WRONG SIZE(<P><SPAN>FOUND OBSTRUCTION BEHIND #7 OVEN TRAYS. CLEANED OBSTRUCTION AND PERFORMED OPS CK PER CMM 25-36-34. OPS CK GOOD. C/W SMOKE IN CABIN INSPECTION REF AMM 05-51-56. NO DEFECTS NOTED.</SPAN><SDR JJBA2022020431033Coffeemaker · odorFA REPORTS BURNING SMELL FROM COFFEE MAKERS. CLEANED UP COFFEE BREW WARMER, PERFORMED VISUAL INSPECTION COFFEE BREW CRACKS, WIRES. NO DEFECTS NOTED. OPS CHECK GOODSDR SIMA2022013129001Coffeemaker · odorDURING T/S OF SMELL FOUND FWD INBOARD COFFEE MAKER LOCKING ARM INOP-C/A-RAR FWD INBOARD COFFEE MAKER IAW ERJ 170 AMM 25-37-03-000/400-801-A OP CHECKS GOOD IAW 25-37-03SDR AALA202201267479Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORT OF ELECTRICAL SMOKE AND A BRIGHT ORANGE GLOW FROM THE #2 OVEN IN THE FWD GALLEY. REPLACED OVEN WITH SERVICEABLE UNIT IAW AMM 25-32-03, OPS CHECK GOOD.SDR CALA2022012000193Oven · odorCREW REPORTS FROM SMOKE/ODOR IN THE PLANE QUESTIONNAIRE FORM 46-6020 IN FLIGHT AN ELECTRICAL , OIL, ACRID ODOR COMING FROM THE FWD GALLEY AIR VENT. PERFORM SMOKE/ODOR IN THE FLIGHT DECK/CABIN - CONDITIONAL INSPECTION PER AMM 05-51-26-800-801-C1 UPDATED MAA CODSDR N6WA2022011702None · dirtySMOKE OBSERVED BEHIND #1 COFFEEMAKER. COFFEE POT # 1 FOUND DIRTY. CLEANED COFFEE POT AND HOT PLATE SURFACE FOR # 1 COFFEE MAKER AND PERFORMED OPS CHECK IAW CRJ AMM 25-32-04. OPS CHECK GOOD NO DEFECTS NOTED.SDR SCNA20220117001None · noneDEFECT: AFT OVEN ON RIGHT SMOKES WHEN USED. RESOLUTION: REMOVED SPILLED AND BURNED FOOD FROM OVENS. RAN OVENS REF M/M 25-30-00. OPS CHECK GOOD.SDR HNAA2022011200048Warmer · burnedINFLIGHT F/A REPORTS BURNING SMELL FROM HOT JUG AREA SELECTED HOT JUG OFF SMELL WENT AWAY. F/A ALSO REPORTS A MAPLE SYRUP SMELL IN THE SAME AREA. PAGE 200-3 ITEM 7 C/W W/C 25-00-04 WITHIN 100 FLT HRS. MAINTENANCE INSPECTED HOT JUG AREA NO DAMAGE NOTED.SDR YENA2022010700013Coffeemaker · failedFLT 379, DCA-FLL. VERY FAINT BURNING SMELL FROM FORWARD GALLEY BY COFFEE MAKER DURING DESCENT. DISSIPATED AFTER LANDING COFFEE MAKER WAS ON (MX-270 ATTACHED). ( COFFEE MAKERS ) ; INSP FOUND FWD COFFEE MAKER 106 HEATING PLATE BURNT OUT CAUSING ODOR PLACED ON NESDR CALA2022010300010Cart · odorSTRONG EXHAUST SMELL IN CABIN AND COCKPIT WHEN ARRIVING FOR FIRST FLIGHT OF THE DAY. SWITCHING TO APU NO HELP FILTERS AND NO HELP METALLIC/ OILY SMELL NOTICED IN FLIGHTDECK, E AND E AND FC CABIN. OPENED APU AND NO LEAKS NOTED AND NO OIL CONSUMPTION IN PLNOIL. SDR DALA2021120207450Coffeemaker · odor(LOG 8347575) FA'S REPORT A "HOT ELECTRICAL SMELL" FROM FORWARD GALLEY COFFEE MAKER AREA. PULLED CB'S FOR COFFEE MAKERS AND SMELL SUBSIDED. R/R FWD GALLEY COFFEE MAKER PER B737 MM 25-31-87.SDR AALA202111248914Oven · odorAIRCRAFT WAS NOT GROUNDED # 1 OVEN VENT FAN - FORWARD GALLEY NOISY ALSO "PLASTIC" ODOR COMING FROM THE OVEN, **SUPPLEMENTAL REPORT FOR AALA202111238914: REPLACED FORWARD GALLEY #1 OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-35-19.** (CLOSSDR AALA202111238914Fan · noisyAIRCRAFT WAS NOT GROUNDED # 1 OVEN VENT FAN - FORWARD GALLEY NOISY ALSO "PLASTIC" ODOR COMING FROM THE OVEN, **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR AALA202111178689Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN HAS A STRONG BURNT PLASTIC SMELL, AFFECTS FOOD TASTE. REMOVED AND REPLACED FORWARD GALLEY OVEN PER AMM 25-35-19.SDR CALA2021110802042Oven · odorBURNED PLASTIC OR BURNED ELECTRICAL SMELL IN COCKPIT INSPECTED BEHIND OVERHEAD CIRCUIT PANELS OR DAMAGED WIRES OR BURN SMELL. NO FAULTS FOUND. INSPECTED FIRST CLASS GALLEY FOR FOREIGN MATTER ON COFFEE BURNERS AND IN OVENS. COULD NOT FIND ANY SMELL. FLIGHT CRSDR AALA202111013212Oven · odorAIRCRAFT WAS NOT GROUNDED: FIRST CLASS GALLEY OVEN NUMBER 2 HAS A STRONG ELECTRICAL BURNING SMELL WHEN OPERATING. CIRCUIT BREAKER DID NOT POP. REMOVED AND REPLACED FORWARD GALLEY NUMBER 2 OVEN PER AMM 25-35-19-0401.SDR AALA202110258825Oven · overheatedAIRCRAFT WAS NOT GROUNDED: OVEN IN THE FIRST CLASS GALLEY-RIGHT OVEN BECAME EXTREMELY HOT AND WOULDN'T COOL OFF WHEN TURNED OFF. REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER 25-33-00.SDR AALA202110190134Oven · odorAIRCRAFT WAS NOT GROUNDED: SLIGHT SMOKE SMELL FORWARD OF MID GALLEY BULKHEAD. SECURED POWER TO MID GALLEY AND SMELL DISSIPATED. REPLACED MID GALLEY SINGLE OVEN PER AMM 25-32-02-400.SDR DALA2021101906447Coffeemaker · odorBURNING ELECTRICAL SMELL COMING FROM FRONT GALLEY. USING AMDS CARD 0550-2002 TO TROUBLESHOOT BURNING SMELL IN FWD GALLEY. FOUND WEIRD BURNING SMELL TO BE COMING FROM L/H COFFEE MAKER IN POSITION 105. (845719) REMOVED AND REPLACED COFFEE MAKER AT POS. 105 IAW ASDR R61A2021100800798None · noneAFT COFFEE MAKER EMITTING SMOKE. DEFERRED.SDR AALA202110085194Oven · odorAIRCRAFT WAS GROUNDED: FIRST CLASS OVEN NUMBER 2 HAS A STRONG ODOR INSIDE OVEN. REMOVED AND REPLACED FORWARD GALLEY NUMBER 2 OVEN PER AMM 25-32-03.SDR AALA202110041154Coffeemaker · burnedAIRCRAFT WAS GROUNDED: AFT FLIGHT ATTENDANT SMELLED SMOKE AND FUMES AND SAW A FLASH FROM THE GALLEY. MAINTENANCE FOUND THE RIGHT COFFEE MAKER TERMINAL END BURNT AT BOTTOM OF COFFEE MAKER. REPLACED COFFE MAKER AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PSDR 2DYA20210927000None · noneMX DISCOVERED THAT THE MID GALLEY COFFEE MAKER WAS INOP. MX MECHANIC CLEANED GROUND ELECTRICAL CONNECTORS IAW B767 AMM 20-41-00. COFFEE MAKER OPS CHECK NORMAL IAW B767 AMM 25-31-00.SDR CALA2021091501570Oven · fireOVEN 711 HAD FIRE.PULLED CB AND USED WATER FIRE EXT. TO PUT OUT FLAMES.SDR SWAA2021091516669Coffeemaker · odorFLIGHT ATTENDENT REPORTS FWD COFFEE POT HAS ELECTRICAL BURNING ODOR. POT TURNED OFF. ; / [01] REMOVED AND REPLACED COFFEEMAKER AS PER AMM 25-33-26SDR DALA2021083005131Coffeemaker · odor(LOG 8025524) ATL F/A REPORTED "BURNING ODOR" IN AFT OF AIRCRAFT IN GALLEY DURING T OFF& INITIAL CLIMB-OUT NO HEAT/SMOKE NOTED. R/R #2 COFFEE MAKER REF B737 AMM 25-31. OPS CK NORMAL OK FOR SVC.SDR CALA2021083001449Coffeemaker · odorCOFFEE MAKER 417 HAD BURNING PLASTIC SMELL. IT WAS TURNED OFF AN D SMELL WENT AWAY. INSPECTED AND FOUND LOOSE CONNECTOR D07J PIN PULLED OUT FOR COFFEE WARMER POSITION 417. SEE PHOTO. SMOKE FORM 46-6020 ATTACHED PERFORMED INSP REF AMM 05-51-26-800-801-C1 AND F
Back to JASC 2530