JASC 2530

Service difficulty reports · 4,470

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR DALA2021090105173Oven · odorSHIP 6802 AFT GALLEY(LOC405) OVEN #5 BURNING/PLASTIC/ELECTRICAL SMELL FROM SURROUNDING VENTS ONLY WHEN OVEN IS IN USE. CORRECTIVE ACTION: REMOVED AND REPLACED AFT GALLEY OVEN #5 IAW B757 AMM 25-31, OPS CKS NML. (7987770)Aug 27, 2021 · N703TW · Boeing 7572Q8SDR YENA2021083100552Coffeemaker · failedFLT 2577, BOS-LAS. FWD COFFEE MAKER INOP. LOUD POP ELECT SMELL C/B 105 POPPED ( COFFEE MAKERS ); R & R COFFEE MAKER PER AMM 25-35-00. OPS CHECK GOOD. THIS CLEARS MDDR 447726. MX4 UPDATED. PLACARD REMOVED. MCC NOTIFIED.Aug 25, 2021 · N962JT · Airbus A321231SDR CALA2021082501425Oven · smokeFIRST CLASS GALLEY OVEN 107 SMOKES WHEN ON CABIN ATENDENT REPORTS ELEC SMOKE WHEN OPENING OVEN 107. FWD TO NEF 2500BR OVEN INOP PENDING FURTHER INVESTIGATION, MAINT PROCDURE CW, MCC INFORMED. C/B COLLARD NOC DESK: 787 NAME: ERIC S DATE: 24-Aug 24, 2021 · N14011 · Boeing 78710SDR IPXA2021082072962Chiller · fumesAPPROX 5 MIN BEFORE LANDING. THE JUMPSEATERS IN THE SUPERNUMERRARY ARE SMELLED A STRONG ELECTRICAL SMELL AND SOME SMOKE TRACE AMOUNTS. THE NOTICED THE REFRIGERATOR CIRCUIT BREAKER POPPED AND THYE THE FUMES AND SMOKE DISAPATED. DEFERRED GALLEY REFRIGERATOR IAW Aug 18, 2021 · N257UP · Doug MD11FSDR AALA202108181376Oven · smokeAIRCRAFT WAS NOT GROUNDED: OVEN NUMBER 2 IN FORWARD GALLEY IS SMOKING, COULD NOT BE SOMETHING SPILLED BUT OVEN LOOKED CLEAN AND SMELLED LIKE COULD BE ELECTRICAL.CIRCUIT BREAKER WAS PULLED JUST IN CASE. REMOVED AND REPLACED OVEN NUMBER 2 1-4 FORWARD GALLEY OPERAug 17, 2021 · N924US · Airbus A321231SDR AALA202108182896Chiller · odorAIRCRAFT WAS NOT GROUNDED: G5 CHILLER NOISY, ALSO ELECTRICAL SMOKE SMELL NOTICEABLE BY FLIGHT ATTENDANTS AND PASSENGERS IN AREA. CHILLER WAS TURNED OFF AND SMELL DISSIPATED AFTER. ACCOMPLISHED WORK CARD 72L00021001-SMOKE ODOR FUMES INITIAL TROUBLESHOOTING. NO Aug 16, 2021 · N755AN · Boeing 777223SDR AALA202108169478Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY COFFEE MAKER #2 SMELLS BURNT. REPLACED #2 COFFEE MAKER PER AMM 25-35-15.Aug 15, 2021 · N409AA · Airbus A321253NXSDR DALA2021081704742Coffeemaker · smokeSHIP 685 AFS F/A REPORTED BRIEFLY SMELLING WHAT APPEARED TO BE SMOKE WHEN TURNING ON AFS COFFEE MAKER . COFFEE MAKER OFF AND NO OTHER INDICATIONS OF PROBLEMS ON SMOKE. CORRECTIVE ACTION: R/R COFFEE MAKER PER B757 AMM 25-31 OPS CK GOOD FOUND ORIGINAL COFFEE MAKAug 14, 2021 · N685DA · Boeing 757232SDR DALA2021080204335Oven · inoperativeSHIP 3503 - OVEN INOPERATIVE LOCATIONS 411. CORRECTIVE ACTION: DEACTIVATED OVEN AT GALLEY 411. MEL APPLIED. C/W NO GO ODI.(1895231)Aug 1, 2021 · N503DN · Airbus A350941SDR DALA2021072604196Oven · smokeSHIP 3502 - FWD GALLEY SINGLE OVEN SMOKING. CORRECTIVE ACTION: DEFERRED OVEN #5 IN FWD GALLEY PRECAUTIONARY DUE SMOKE. R/R NBR 5 OVEN FWD GALLEY PER A350 AMM 25-36.(1885274)Jul 23, 2021 · N502DN · Airbus A350941SDR QXEA2021072000369Drain · dirtyFISH SMELL COMING FROM DRAIN BASIN IN GALLEY. REMOVED FROM SERVICE. CLEANED GREY WATER TANK AND DRAIN BASIN AS NECESSARY. SMELL NO LONGER APPARENT IN AFT GALLEY. NO FURTHER DEFECTS NOTED. RETURNED TO SERVICE.Jul 19, 2021 · N440QX · Bombdr DHC8402SDR CALA2021070501025Oven · shortedAFT GALLEY OVEN 411 SMOKED CB PULLED SMOKE LINGERED ON FOR 15 MI N THEN SLOWLY DISSIPATED CONDUCTED TASK 05-51-58-910-801-C1. INSTALLED OVEN AT POSITION 411. PER AMM TASK 25-34-00-400-801-C3. RAN OVEN FOR 15 MIN. OPS CHK GOOD. ADD EMP:181152 ROTABLE PARTS CHANJul 4, 2021 · N17133 · Boeing 757224SDR SWAA2021071293386Coffeemaker · odorACRID SMELL IN FWD GALLERY ONLYIMPROVED WHEN WORK LIGHT AND COFFEE MAKERS CB'S PULLED / PERFORMED CONDITIONAL INSPECTION AND FOUND FWD GALLEY COFFEE MAKER; CAUSING THE SMELL. PER A.M.M FIM TASK 21-00-800 CONDITIONAL INSPECTION 05-51-56 REFERENCE LOG PAGE 17187Jul 2, 2021 · N8559Q · Boeing 7378H4SDR DALA2021062903530Oven · odorSHIP 3510 ELECTRICAL SMELL WHEN OVEN TURNED ON LOCATION 410. CORRECTIVE ACTION: REMOVED AND REPLACED OVEN. (1855975)Jun 28, 2021 · N510DN · Airbus A350941SDR DXTA2021062344090Chiller · odorFUSELAGE AUXILIARY STRUCTURE: GOT A FAINT SMELL OF ELECTRICAL IN THE GALLEY AREA. WE SUSPECT IT COULD BE THE CHILLER. I BARELY SMELLED ANYTHING BUT THE FLIGHT ATTENDANT DID SMELL IT AND TURN THE CHILLER OFF SMELL WENT AWAY // SIGN OFF // REMOVED AND REPLACED GJun 22, 2021 · N237QS · Cndair CL6002B16SDR AALA202106307133Oven · overheatedAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN #2 AT THE GATE WAS SELECTED TO LOW FOR A FEW MINUTES THEN TO HIGH, A FIRE STARTED NEAR THE BLOWER EXHAUST FAN AND WAS EXTINGUISHED WITH A HALON FIRE EXTINGUISHER. REPLACED # 2 OVEN AND ACCOMPLISHED A SATISFACTORJun 21, 2021 · N328RR · Boeing 7378SDR AALA202106247133Oven · fireAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN #2 AT THE GATE WAS SELECTED TO LOW FOR A FEW MINUTES THEN TO HIGH, A FIRE STARTED NEAR THE BLOWER EXHAUST FAN AND WAS EXTINGUISHED WITH A HALON FIRE EXTINGUISHER. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)Jun 21, 2021 · N328RR · Boeing 7378SDR QXEA2021061700293Unknown · sparksFLIGHT ATTENDANT SAW AND HEARD A FLASH AND SMALL POP SOUND ALSO SMELLED AN ACIDIC SMOKE SMELL. CB WAS STILL SET. REMOVED FROM SERVICE. C/W MCN 62172-01 ISSUE 02 & FORM M-744 COMPLETED AND SENT UPON ARRIVAL TO AIRCRAFT NO ODOR OR SMELL NOTED. INSPECTED AFT GAJun 16, 2021 · N447QX · Bombdr DHC8402SDR AALA202106149015Oven · odorAIRCRAFT WAS GROUNDED: ELECTRICAL SMELL AND SLIGHT HAZE REPORTED IN AFT GALLEY, FLIGHT DECLARED EMERGENCY AND DIVERTED TO SJU. ACCOMPLISHED OPERATIONAL CHECK OF AFT GALLEY EQUIPMENT IAW AMM 25-32-01, 25-33-01, AND 33-26-02, NO ISSUES NOTED.Jun 13, 2021 · N323RM · Boeing 7378SDR DALA2021061403205Unknown · odorSHIP 3405 OVEN 1 POS F106 SMELLS LIKE BURNING WIRES. CORRECTIVE ACTION: REMOVED AND REPLACED OVEN. INSP CONNECTOR NO ARCING OR SMOKE/FUME SMELL. (1838077)Jun 12, 2021 · N405DX · Airbus A330941SDR DALA2021060103002Oven · dirtySHIP 3318 OVEN A215 LOC 407 DIRTY ODOR AND SMOKEY. CORRECTIVE ACTION: CLEANED OVEN. (1816476)May 22, 2021 · N818NW · Airbus A330323SDR YENA2021052700334Oven · smokeFLT 177, BOS LAS. DURING CRUISE FLIGHT, CABIN CREW ADVISED SMOKE IN THE FWD GALLEY COMMING FROM OVEN. THEY SHUTT OFF OVEN AND SMOKE DISAPPATED, PER MCC PULLED BOTH CB FOR OVEN 103 AND 104 WERE PULLED AS A PRECAUTION. FLIGHT ATTENDANT BELIEVED SMOKE TO BE ELECTMay 22, 2021 · N980JT · Airbus A321231SDR QXEA2021052300260Control Panel · sparksCLIMBING THRU 10000' F/A REPORTED SPARKS COMING OUT OF AFT GALLEY PANEL; LEFT CENTER AND RIGHT CB'S OF "LIQUID WARMERS" AND AREA ENCOMPASSING SWITCHES OVER MAPCO "SUPER HOT" AS A PRECAUTION, F/A TURNED OFF ALL SWITCHES. AREA REMAINED HOT. NO VISIBLE SIGNS OF SMay 22, 2021 · N438QX · Bombdr DHC8402SDR ASAA2021052134900Coffeemaker · defectiveINFLIGHT CREW DETECTED NOTICEABLE SMELL/ODOR OF BAKING BREAD OCCURRED IN CRUISE AND WAS TRANSIENT ON ARRIVAL AND DEPLANING AFT F/A CREW REPORTED STRONG SMELL OF BURNING TOAST SEVERAL GUESTS NOTICED THIS SMELL DURING DEPLANING NO IMPAIRMENT OR DISCOMFORT CAUSEDMay 21, 2021 · N593AS · Boeing 737890SDR AALA202105219011Oven · odorAIRCRAFT WAS GROUNDED: THREE FLIGHT ATTENDANTS COMPLAINING ABOUT A SMELL IN THE FORWARD AREA NEAR DOOR 1L. FUEL OR ELECTRICAL SMELL AND MILD IRRITATION TO EYES AND THROAT. ALSO, SMELLED IN FLIGHT DECK. ACCOMPLISHED SOF EVENT W/C 08L00021001 AND FOUND GALLEY G1May 20, 2021 · N973AN · Boeing 737823SDR AALA202105139019Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN 3 NEEDS CLEANING. SMOKY SMELL. REPLACED OVEN PER AMM 25-35-19.May 12, 2021 · N112AN · Airbus A321231SDR AALA202104299001Oven · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANTS ADVISED STRONG BURNING SMELL IN FORWARD GALLEY THAT LASTED APPROXIMATELY 30 TO 40 SECONDS. NO VISIBLE SMOKE. ACCOMPLISHED JOB CARD 26L00021001. REPLACED RIGHT FORWARD GALLEY OVEN PER AMM 25-35-19.Apr 28, 2021 · N679AW · Airbus A320232SDR DALA2021042202361Oven · odorAIRCRAFT RETURNED TO GATE BECAUSE OF ELECTRICAL BURNING SMELL IN FRONT GALLEY AREA. RAN BOTH ENGS WITH BLEED AIR AND PACKS ON AND NO ODOR SMELL NO SMOKE PRESENCE. R/R RT RECIRC FAN FILTER. NOTED AS A PRECAUTION CHECKED CABIN PC POWER SYS OR ISSUES AS PER B737 Apr 21, 2021 · N3734B · Boeing 737832SDR P5CA2021041800094Galley · odorFUMES IN COCKPIT COMING FROM GALLEY. RAN SMOKE, FIRE OR FUMES CHECKLIST. REMOVED POWER FROM GALLEY VIA PULLED C/B, FUMES/ SMOKE SMELL SLOWLY DISSIPATED (<P>UPON GALLEY INSPECTION, DISCOVERED CHARRED PAPER TOWEL CONTAINER(WRAPPED IN PAPER), LEANING AGAINST A Apr 18, 2021 · N643GT · Boeing 7673JHFSDR DALA2021042102330Oven · odorSHIP 660 DOOR 1R OVEN-MELTED CUP INSIDE. CORRECTIVE ACTION: TURNED ON ALL EQUIPMENT. INSPECTED OVERHEAD LTS & BALLASTS NO FUMES NOTED. INSPECTED PASSENGER READING LTS & PSU LTS, NO FUMED NOTED. NO FUMES NOTED COMING FROM IFE EQUIP (MONITORS & EMPOWER OUTLETS).Apr 18, 2021 · N660DL · Boeing 757232SDR QXEA2021041300185Oven · smokeFA REPORTS FORWARD G2 OVEN HAD SMOKE WHILE COOKING FOOD IN FLIGHT. STOPPED USE OF OVEN. NO FURTHER SMOKE IDENTIFIED. REMOVED FROM SERVICE. UPON ARRIVAL TO AIRCRAFT THE SMELL OF SMOKE WAS NO LONGER PRESENT. PERFORMED GVI OF FWD GALLEY G2 OVEN, FOUND NO DAMAGE, Apr 12, 2021 · N639QX · Emb ERJ170200LRSDR YENA2021041200224Oven · odorFLT 701, FLL-LAX. FORWARD GALLEY LEFT #103 OVEN -OFF FOR ELECTRICAL SMELL WHEN ON IN FLIGHT ( GALLEY OVEN (MINT CONFIG ONLY) ); OPS CHECKED FOR 30 MINS FOUND NO EVIDENCE OF SMELL. OK FOR SERVICE AT THIS TIME. PLACARD REMOVED MX-4 UPDATED MCC NOTIFIED THIS CLEAApr 9, 2021 · N990JL · Airbus A321231SDR AALA202104059004Chiller · odorAIRCRAFT WAS GROUNDED: ELECTRIC ODOR IN AFT GALLEY, WENT AWAY WHEN CHILLER TURNER OFF. ACCOMPLISHED SOF INSPECTION IAW WORKCARD 26L00021001, OPS CHECK GOOD.Apr 3, 2021 · N989AU · Airbus A321231SDR N6WA2021033002Heater · failedELECTRICAL BURNING SMELL IN COCKPIT.INSPECTED A/C FOR ELECTRICAL SMELL. FOUND FWD GALLEY HEATER SWX TO HAVE BAD BULB (REPLACED) DURING OPERATION GOT BURNING SMELL & CB B11 POPPED. DEFERRED GALLEY HEATER OCN 70071986 PER MEL 21-40-01 CAT C AUTH MXCMar 30, 2021 · N544GJ · Cndair CL600*SDR J7SA2021040200281Microwave Oven · odorDURING DESCENT, WHILE MICROWAVE WAS IN USE, CREW DISCOVERED ELECTRICAL SMELL AND SMALL MIST OF SMOKE. AIRCRAFT LANDED WITHOUT INCIDENT AT KAUS. MICROWAVE DEACTIVATED VIA VCB 2430. ACCOMPLISH LATEST REVISION, ELECTRICAL WIRING INSTALLATIONS (ATA 97) INSPECTION,Mar 30, 2021 · N651FX · Gulstm GVISDR IPXA2021033067550Wire · sparksEMERGENCY DECLARED, O2 MASK DROPPED BUT NOT DONNED - LANDED UNEVENTFULLY - AC OOS** ON DESCENT SPARK FROM BEHIND GALLEY AREA RPRTD BY ACM SMOKE & FUMES NOTED. AFT CB'S FROM GALLEY PULLED SMOKE & FUMES SUBSIDED. GROUND SERVICE BUS C/B POPPED AFTER LANDING. MAMar 30, 2021 · N282UP · Doug MD11FSDR SWAA2021040159611Coffeemaker · odorON TAKEOFF REJECTED TO @ 92 KNTS DUE TO VERY STRONG INTENSITY BURNING ELECTRICAL SMELL. F/A'S SAID THEY SMELLED IT FROM ROW 3 FWD TORNADO FLT DECK / PERFORMED CONDITIONAL INSPECTION AS PER AMM 05-51-56 AND FIM 21-00 TASK 806 R/R BPCU PRECAUTIONARY L/P 0567667 Mar 28, 2021 · N473WN · Boeing 7377H4SDR AALA202103279004Oven · smokeAIRCRAFT WAS NOT GROUNDED: RIGHT OVEN OF FORWARD GALLEY SMOKING DURING USE. REMOVED AND REPLACED FORWARD GALLEY OVEN IAW AMM 25-35-00.Mar 25, 2021 · N178US · Airbus A321211SDR DALA2021030501288Coffeemaker · odor(LOG 5759227) AFT GALLEY COFFEE MAKER #1 HAD ELECTRICAL ODOR. INSP WIRING BEHIND COFFEE MAKER NTF. REPLACED COFFEE MAKER PER B737 AMM 25-31.Mar 4, 2021 · N372DA · Boeing 737832SDR SWAA2021030452632Light · crackedG4 GALLEY EMERGENCY EXIT LIGHT HAS CRACKED LENS / REPLACED G4 GALLY EMERGENCY EXIT LIGHT PER AMM 33-51-01-960-802. OPS CHECK GOOD.Feb 25, 2021 · N405WN · Boeing 7377H4SDR QXEA2021020800054Oven · smokeINFLIGHT SMOKE EMITTED FROM FORWARD OVEN IN FWD GALLEY. DEFERRED THE OVEN AND RETURNED THE AIRCRAFT TO SERVICE. CLEARED DISCREPANCY BY REPLACING FWD OVEN IN FWD GALLEY IAW E175 AMM TASK 25-37-02-000/400-802. OPS CHECKED GOOD. THIS CLEARS DMI, PLACARD REMOVED.Feb 7, 2021 · N627QX · Emb ERJ170200LRSDR IPXA2021020865455Chiller · odorINSPECTION TYPE:NASTRONG CHEMICAL ODOR IN COCKPIT.DID NOT NOTICE A CHEMICAL SMELL BUT DID NOTICE A STRONG ELECTRICAL SMELL AROUND COURIER SEATS AND GALLEY AREA. HAS HISTORY OF REFRIGERATOR NOT WORKING AND GIVING OFF A BURNING SMELL. R&R REFRIGERATOR IAW AMM 25Feb 5, 2021 · N290UP · Doug MD11FSDR AALA202101289013Oven · odorAIRCRAFT WAS NOT GROUNDED. FLIGHT ATTENDANT REPORTED THAT AN AMMONIA TYPE OF ODOR WAS EMITTING FROM THE OVEN IN THE FORWARD GALLEY. ACCOMPLISHED TASK CARD 29L00021001. GALLEY OVEN NUMBER 2 SOURCE OF ODOR. REPLACED OVEN, PER AMM 25-35-19.Jan 27, 2021 · N9004F · Airbus A319115SDR SWAA2021021545074Seat Track · wornWEAR ON TRACK RAIL-ASSY FIRST OFFICER RAIL AFT LT AND RT SIDE AT COCKPIT (2 EA) / REPLACED TRACK RAIL-ASSY FIRST OFFICER RAIL AFT LT AND RT SIDE AT COCKPIT (2EA) IAW B737-700 AMM 25-11-11-400-801Jan 12, 2021 · N406WN · Boeing 7377H4SDR DALA2021011300196Oven · odorBURNING PLASTIC SMELL COMES FROM OVEN WHEN TURNED ON. REMOVED OLD OVEN, INSPECTED AREA, NO DEFECTS NOTED. INSTALLED NEW OVEN. OPERATIONS GOOD, REF B737 AMM 25-31.Jan 12, 2021 · N925DZ · Boeing 737932ERSDR W6JA20210106041Oven · fireCREW REPORTED EXPERIENCING FIRE IN GALLEY, WITH SMOKE IN CABIN. DECLARED AN EMERGENCY TO LAND NEAREST AIRPORT. CO-PILOT WAS ABLE TO CONTAIN FIRE WITH A HAND HELD FIRE EXTINGUISHER TO GALLEY OVEN. SOURCE OF FIRE WAS FROM A CARDBOARD/FOIL CATERING CONTAINER IJan 5, 2021 · N144PK · Gulstm GIVSDR AALA202101049023Coffeemaker · overtempAIRCRAFT WAS NOT GROUNDED. CIRCUIT BREAKER TRIPPED REAR PANEL S-V IDENTIFIED BREAKER ON 121VU S28 GALLEY CONTROL. F/A REPORTED A SLIGHT BURNING PLASTIC SMELL IN FORWARD GALLEY. THEY HAD CHILLER AND COFFEE MAKER ON BUT NOT OVEN. FOUND FORWARD GALLEY NR 1 COJan 2, 2021 · N165NN · Airbus A321231SDR SWAA2020123139075Coffeemaker · faultedFLIGHT ATTENDANT EXPERIENCED ODD ODORS FROM AFT GALLEY. PERFORMED INSPECTION, IAW FIM TASK 21-00-806. DISCOVERED AFT INBOARD COFFEE MAKER EXTREMELY HOT AND EMINATING A STRONG ODOR. R & R AFT INBOARD COFFEE MAKER, PER AMM 25-30-01. OPERATIONS CHECK GOOD. IDec 31, 2020 · N8326F · Boeing 7378H4SDR SWIA202054447Oven · smokeFLIGHT ATTENDANT REPORTS THAT FORWARD GALLEY OVEN WAS SMOKING WHILE IN SERVICE. SMOKE DISSIPATED UPON SHUTTING OVEN OFF. FLIGHT 3357-FILED CLOSED. TROUBLESHOT PER FIM. VERIFIED SMOKE AND BURNING SMELL TO BE COMING FROM FWD GALLEY OVEN. REMOVED AND REPLACEDec 7, 2020 · N196SY · Emb ERJ170200LRSDR DALA2020113003920Oven · overheatedSMKE-ON APPROACH INTO LAS, SMOKE AND FUMES FROM F/C OVEN. CONFIRMED OVEN OVERHEAT. CORRECTIVE ACTION: REPLACED OVEN.Nov 27, 2020 · N832DN · Boeing 737932ER
Back to JASC 2530