SDR ASAA2018100326356Coffeemaker · inoperativeUPPER FWD COFFEE MAKER MADE POPPING NOISES AND EMITTED A BURNING SMELL IDENTIFIED AS SOMETHING OTHER THAN COFFEE TURNING THE COFFEE MAKER OFF RESOLVED THE ISSUE. GROUNDED - YES. SMELL ORIGINATED FROM A SINGLE COFFEE MAKER 1-1 NO SMOKE REPORTED REMOVED COFFEE MSDR AALA201810019054Oven · odorFORWARD NR 2 OVEN PLASTIC/ELECTRIC ODOR AND SOME SMOKE. FORWARD GALLEY #2 OVEN INOPERABLE. PULLED AND COLLARED CIRCUIT BREAKER FOR OVEN. REPLACED THE OVEN IAW AMM 25-35-19. OPS CHECKED NORMAL.SDR CALA2018092801995Oven · dirtyOVEN 409 CREATED SMOKE WHEN ON. IRO DETERMINED POSSIBLE GREASE I N OVEN MEET CREW ON ARRIVAL , SHE TOLD ME THAT WAS NO REAL SMOKE BUT A SMELL LIKE TOASTED BREAD BURNED. SMELL IS FROM OVEN FAN IMPREGNATED WITH FOOD GREASE, CLEANED, NO INSPECTED OVEN 409 FROM BESDR SWAA2018092425428Coffeemaker · inoperativeLT AFT COFFEE MAKER INOP FLIGHT ATTENDANT REPORTED A SMELL OF ELECTRIC ODOR. R&R COFFEE MAKER PER AMM.SDR AALA201809209032Coffeemaker · odorTHE AIRCRAFT WAS GROUNDED. ELECTRICAL SMELL IN AFT CABIN. ACCOMPLISHED JOB CARD 26L00021001. COFFEE HOTPLATE FOUND TO BE THE SOURCE OF ODOR. REPLACED COFFEE HOTPLATE PER CMM 25-30-35.SDR U2RA201809190001Oven · smokeAFT GALLEY LEFT HAND NR 3 OVEN SMOKING WHEN IN USE. CIRCUIT BREAKER PULLED. OVEN PLACED ON NON-ESSENTIAL FURNISHING DEFERRED MAINTENANCE ITEM, IN ACCORDANCE WITH NEF MANUAL 25-20-01.SDR AALA201809219010Coffeemaker · odorNR 2 COFFEEMAKER, WHEN TURNED ON CREATED A BAD ELECTRICAL ODOR. REPLACED THE NR 2 COFFEEMAKER IAW AMM 25-32-00. OPS CHECKED OK FOR SERVICE.SDR DALA2018092105700Oven · smokeSMOKE EMANATED FROM AFT GALLEY OVEN 1 AND 3 SMOKE DETECTOR IN AFT CREW REST WENT OFF, WARNING LIGHT ON OVERHEAD PANEL ILLUMINATED "AFT CR SMK DETCR" MASTER WARNING AND FIRE BELL. REPLACED NR 1 AND NR 3 OVENS AS PRECAUTION.SDR AALA2018091979023Chiller · odorDURING TAXI, THE AFT GALLEY ODOR WAS REPORTED BY THE FLIGHT ATTENDANTS, EYES BURNING, LIGHT HEADED. AIRCRAFT RETURN TO GATE. IAW TSM 05-50-00-810-831-A AND TSI 0077569 SOF EVENT GALLEY LAVATORY EXTRACT FAN WAS REPLACED AS A PRECAUTION. REPLACED THE AFT GALSDR AALA201809189020Chiller · odorTHE AIRCRAFT WAS GROUNDED. AFT GALLEY ODOR REPORTED BY FLIGHT ATTENDANT'S EYES BURNING. LIGHT HEADED OCCURRED DURING TAXI OUT. PER TSM 05-50-00-810-831-A AND TSI 0077569 SOF EVENT GALLEY/ LAVATORY EXTRACT FAN AND CHILLER REMOVE AND REPLACED AS PRECAUTIONARY. RSDR ASOA2018091944048Coffeemaker · faultyIAH - FLIGHT 4340, THE FLIGHT ATTENDANT REPORTED A BIT OF SMOKE OR SOME KIND OF BURNING WHEN NR 1 COFFEE POT SELECTED ON. MAINTENANCE REMOVED AND REPLACED THE NUMBER ONE COFFEE POT, OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED FOR RETURN SDR AALA201809139002Oven · odorCOACH GALLEY OVEN NR 9 EMITTED A BURNING PLASTIC ODOR WHEN OPERATING. REPLACED THE OVEN IAW AMM 25-32-00. OPS CHECKED GOOD.SDR AALA2018091109036Oven · odorSTRONG ODOR IN GALLEY ONE, ODOR SEEMS TO COME FROM THE NR 2 OVEN. PULLED THE CIRCUIT BREAKER AND THE ODOR DISSIPATED. THE ODOR WAS ELECTRICAL. REPLACED THE NR 2 OVEN IAW AMM 25-35-19-0401. OPS CHECKED GOOD.SDR AALA2018091209021Unknown · odorAFTER TAKE OFF, FLIGHT ATTENDANTS IN AFT GALLEY REPORTED AN ODOR OF BUG SPRAY, COMING FROM THE CART AREA AND DIMINISHED DURING FLT. THE AIRCRAFT WAS GROUNDED. ACCOMPLISHED WC 05-96-70. NOTHING FOUND. OK FOR SERVICE.SDR AALA2018091209002Oven · overheatedNR 3 OVEN IN BUSINESS CLASS GALLEY OVERHEATED IN FLIGHT. CIRCUIT BREAKER TRIPPED. REPLACED THE OVEN, OPS CHECKED IAW AMM 25-35-19.SDR AALA201809079010Chiller · failedFLIGHT CREW REPORT BURNING ODOR COMING FROM THE AFT GALLEY AREA. THE AIRCRAFT WAS GROUNDED. ACCOMPLISHED JC 26L00021001. FOUND THE BURNING ODOR TO BE COMING FROM THE AFT GALLEY CHILLER. REPLACED THE AFT GALLEY CHILLER IAW AMM 25-34-51. OPS CHECKED GOOD. NOSDR AALA201809079008Chiller · shortedFLIGHT ATTENDANT SMELLED BURNING ELECTRICAL ODOR FROM THE AFT GALLEY CARTS, PULLED AFT CHILLER CIRCUIT BREAKER. REPLACED AFT CHILLER CARTS , AFT GALLEY CHILLER, WORKING NORMAL. NO BURNED ODOR PRESENT.SDR ABXA2018082016094Module · odorDURING TAXI TO THE RUNWAY, THE CREW SMELLED A SULFUR/WOOD SMOKE IN THE FLIGHT DECK. THE AIRPLANE WAS REMOVED FROM SERVICE (GROUNDED) AND THE MAINTENANCE TECHNICIAN NOTICED AN ODOR IN THE GALLEY. THE OVEN/HOT CUP MODULE WAS REPLACED. THE CAUSE FOR THE ODOR WAS SDR AALA201808149008Oven · failedFORWARD GALLEY OVEN #2 SMOKES AFTER OPERATION. REPLACED FORWARD GALLEY OVEN #2 PER 25-35-19. OPERATIONS NORMAL. THE AIRCRAFT WAS GROUNDED.SDR ASAA2018081375754Oven · smokeBOTH AFT OVENS HAVE A BURNING PLASTIC ODOR WHILE IN USE. ACFT GROUNDED. REMOVED AND REPLACED THE AFT OVEN IAW AMM 25-32-01. OPS CHECKED GOOD.SDR AALA2018080769031Oven · odorMID-GALLEY OVEN NR 2 HAD ELECTRICAL BURNING ODOR. REPLACED THE NR 2 OVEN IAW AMM 25-35-19-0401. OPS CHECKED SATISFACTORY.SDR YENA2018080610303Coffeemaker · failedFAINT ELECTRICAL ODOR IN THE FWD GALLEY DURING CRUISE. PULLED BOTH COFFEE CIRCUIT BREAKERS, THE ODOR WENT AWAY. REMOVED THE NR 1 AND 2 FWD GALLEY COFFEEMAKERS IAW AMM 25-35-15. POWERED UP THE COFFEEMAKERS. REMAINED ON FOR 1 HOUR. NO FAULTS OR ODORS NOTSDR YENA2018080610302Coffeemaker · failedFAINT ELECTRICAL ODOR IN THE FWD GALLEY DURING CRUISE. PULLED BOTH COFFEE CIRCUIT BREAKERS, THE ODOR WENT AWAY. REMOVED THE NR 1 AND 2 FWD GALLEY COFFEEMAKERS IAW AMM 25-35-15. POWERED UP THE COFFEEMAKERS. REMAINED ON FOR 1 HOUR. NO FAULTS OR ODORS NOTSDR AALA201807249015Oven · inoperativeAIRCRAFT WAS NOT GROUNDED. BURNING SMELL COMING FROM FORWARD GALLEY. ODOR FOUND TO BE FORWARD GALLEY OVEN HAD BURNING DEBRIS AND INOPERATIVE. REPLACED FORWARD GALLEY LEFT OVEN PER AMM 25-35-19.SDR SWAA2018072323684Coffeemaker · faultyDIVERSION, REPORTED BURNT RUBBER SMELL IN AFT GALLEY. R&R NR 2 AFT GALLEY COFFEEMAKER PER AMM.SDR SWAA2018072323683Coffeemaker · faultyDIVERSION< REPORTED BURNT RUBBER SMELL IN AFT GALLEY. R&R NR 1 AFT GALLEY COFFEEMAKER PER AMM.SDR AALA2018071329011Chiller · failedFORWARD CHILLEY HAD WARM AIR AND ELECTRICAL ODOR WHILE IN USE. REPLACED FORWARD GALLEY CHILLER.SDR UIEA2018070401337Oven · malfunctionedOVEN 9A-06 AFT GALLEY HISSED, SPARKED, AND SMOKED AT THE PLUG. OVEN 9A-06 DEFERRED AND ELECTRICALLY SAFE AS PER NEF PROG 25-20-01.SDR DALA2018070404368Oven · smokeOVEN NR 1 SMOKING ACCORDING TO FA. TURNED IT OFF. R&R GALLEY OVEN PER AMM 25-35. OP CHKS NORMAL.SDR AALA2018070539001Oven · smokeFLIGHT ATTENDANT REPORTED THE OVEN IN THE AFT GALLEY SMOKES WHEN IN USE. TURNED OFF THE OVEN. REPLACED THE AFT GALLEY OVEN IAW CMM 25-37-39, CHECKED GOOD.SDR HALA2018062600306Oven · smokeAFT GALLEY OVEN MADE SMOKE. OVEN WAS SHUT DOWN. PERFORMED INSPECTION. OPERATION OF ALL OVENS IN THE AFT GALLEY, OPS CHECK GOOD. OK FOR SERVICE.SDR RAIA201806200001Coffeemaker · shortedCOFFEE MAKER C/B POPPED WITH ASSOCIATED SMOKE SMELL. R&R COFFEE MAKER. OPS CHECK GOOD.SDR AALA201806199006Oven · odorFLIGHT ATTENDANT REPORTED AN ELECTRICAL ODOR COMING FROM FORWARD GALLEY OVEN. THE ACFT WAS GROUNDED. REPLACED THE OVEN IAW AMM 25-32-02.SDR REXA2018060138484Oven · odorOVEN EMITTED A BURNING ODOR. R & R THE GALLEY OVEN IAW AMM 25-32-01, OPS CHECKED GOOD.SDR DALA2018061103956Coffeemaker · smokeAIRBORNE - SMOKE FROM COFFEE POT 102. WHET TO QRH, TURNED OFF GALLEY POWER, SMOKE DISSIPATED. R&R FWD GALLEY F102 COFFEE MAKER. FOUND C/B POPPED ON BACK OF C/M. DID NOT TRY AND RESET OR TEST OLD C/M. FWD GALLEY C/M OPS NORMAL PER AMM 25-33. BREWED 3 FULL POTS.SDR AALA2018060879021Coffeemaker · odorBURNING ODOR IN THE CABIN, REPORTED FROM FLIGHT ATTENDANTS AND PAX. AFT GALLEY CENTER COFFEEMAKER HAS A VERY FOUL ODOR. REPLACED THE AFT GALLEY COFFEEMAKER IAW AMM 25-32-00. LEAK AND OPS CHECKED NORMAL. THE AIRCRAFT WAS GROUNDED.SDR AALA2018060869015Oven · odorNR 2 GENERATOR TRIPPED OFF WITH ECAM GEN 2 FAULT. SUCCESSFUL RESET OF GENERATOR SHORTLY AFTER FLIGHT ATTENDANT CALLED AND SAID FORWARD GALLEY OVEN SMELLED LIKE BURNING PLASTIC. REPLACED FORWARD OVEN IAW AMM 25-35-19.SDR AALA201806069033Chiller · odorFLIGHT ATTENDANTS REPORTED AN ELECTRICAL ODOR IN THE AFT GALLEY NEAR THE LEFT AFT SERVICE DOOR. ODOR WOULD COME AND GO. TROUBLESHOT THE GALLEY CHILLER. REMOVED AND REPLACED THE AFT GALLEY CHILLER IAW AMM 25-34-51-400. OPS CHECKED GOOD. OK FOR SERVICE. THE ASDR AALA201806079018Chiller · odorTHE AIRCRAFT WAS GROUNDED. BURNING ODOR COMING OUT OF VENT NEAR 5 L DOOR. FLIGHT ATTENDANT SMELLED SOMETHING BURNING IN AFT GALLEY. LEFT HAND AFT GALLEY 1 A CHILLER IS INOPERATIVE. REMOVED AND REPLACED CHILLER PER AMM 25-33-01.SDR SWAA2018060522555Coffeemaker · faultyAFT COFFEE MAKER HAD STRONG ELECTRICAL ODOR. R&R AFT GALLEY NR 1 COFFEE MAKER PER AMM.SDR DALA2018060203787Oven · odorFA SMELLED SMOKE FROM THE OTHER OVEN IN GALLEY 1. TURNED OVEN OFF AND PULLED CIRCUIT BREAKERS PER MAINTENANCE. THIS LOC IS 204. PRECAUTIONARY REPLACED OVEN PER AMM 25-31.SDR DALA2018060203786Oven · odorF/A SMELLED SOME SMOKE FROM R1 GALLEY. OVEN LOC F205 SECURED OVEN AND REMOVED FOOD. SMELL THEN DISSIPATED W/ MCC CONCURRENCE F/A'S PULLED C/B FOR THE OVEN. A/C SMOKE & FUMES QUESTIONNAIRE COMPLETED.SDR ASAA2018052424818Coffeemaker · odorON CLIMB OUT, F/A TURNED ON BOTH AFT GALLEY COFFEE MAKERS. THEY IMMEDIATELY STARTED SMELLING A BURNING ODOR THAT SMELLED LIKE ELECTRICAL SMOKE. THEY TURNED OFF THE COFFEE MAKERS AND THE ODOR STARTED DISSIPATING. THEY LEFT THE COFFEE MAKERS OFF FOR THE REMAINDESDR ASAA2018052524776Coffeemaker · odorFA IN FWD GALLEY REPORTED AN ELECTRICAL BURNING ODOR. CIRCUIT BREAKER TO COFFEE MAKERS WERE PULLED TO ISOLATE POSSIBLE CAUSE. ODOR DIMINISHED. ACFT GROUNDED. REMOVED AND REPLACED THE FWD GALLEY COFFEEMAKERS AND PERFORMED GVIS AND FIM 25-31 TASK 803.SDR DALA2018052503606Bolt · looseFA REPORTED A BURNING SMELL AND A SMALL AMOUNT OF SMOKE. TURNED OFF COFFEE MAKER AND SMELL WENT AWAY. MAINTENANCE FOUND TERMINAL 1 BEHIND LT AFT COFFEEMAKER WITH LOOSE BOLT AND TERMINALS HEAT DAMAGE. REPLACE BOTH TERMINALS ON NR 1 POSITION PER SWPM 20-30 AND CSDR HALA2018051700234Unknown · smokeOVEN F1053 STARTED SMOKING WHEN USED. PERFORMED AN OPS CHECK IAW AMM 25-31-00. NO FAULT FOUND. OK FOR SERVICE.SDR YENA2018051750202Coffeemaker · explodedCOFFEEMAKER AFT GALLEY EXPLODED. REMOVED AND REPLACED THE COFFEEMAKER IAW MM 25-25-00. OPS CHECKED OK. COMPLETE BREW CYCLE. NO DEFECTS NOTED.SDR DALA2018051503332Bracket · corrodedDURING PRE-FDA INSPECTION, GALLEY A-2 COMPARTMENT A719 FWD HOLD DOWN BRACKET EXHIBITING CORROSION ON UPPER SURFACE (ACTION ITEM REQUEST ITEM 1). GALLEY A-2 COMPT A719 FWD HOLD DOWN BRACKET REMOVED AND REPAIRED AS PER AMM 25-31-03.SDR AALA2018051649036Coffeemaker · odorELECTRICAL ODOR IN MID GALLEY, AROUND ESPRESSO MACHINE/LIGHTS. PULLED CIRCUIT BREAKER FOR COFFEE, ODOR DISPATCHED. MAINTENANCE FOUND EVIDENCE OF ELECTRICAL ODOR FROM ESPRESSO MAKER. REPLACED BOTH ESPRESSO MAKER AND PERFORMED SATISFACTORY OPERATIONAL CHECKS, NSDR CALA2018051501260Oven · overheatedOVEN SMOKING OR SPARKING OVEN R52-AFT GALLEY-UPR VENT SMOKE W/ELEC SMELL. PWR OFF-NO FIR E. / CAP ADVISED NO ACTUAL FIRE OBSERVED WHEN FA REPORTED THE OVERHEATING CONDITION TO FLIGHT CREW. / PERFORMED VISUAL INSPECTIONS OF EVIDENCE OF ACTUAL FIRE AND SMOKY
Back to JASC 2530