JASC 2530

Service difficulty reports · 4,470

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR CALA2019031100388Oven · odorELECTRICAL BURN SMELL NOTICED BY FLIGHT ATTENDANTS AT AFT GALLY AREA WHILE USING OVEN 425. INSPECTED AND GALLEY AREA FOR ELECTRICAL SMELL AND FOUND OVEN AT POSITION 425 AT FAULT REMOVED AND REPLACED OVEN AND OPS CKS GOOD , ALSO RAN ALL OVENS AND COFFEE MAKERMar 9, 2019 · N78285 · Boeing 737824SDR QXEA2019031100106Oven · smokeFWD GALLEY OVER REPORTED EXTREMELY HOT; STARTED SMOKING, OVEN WAS EMPTY F/A TURNED OFF OVEN AND SMOKE DISSIPATED. REMOVED FROM SERVICE. PLACED OVEN ON NEF (LOGPAGE 866540). RETURNED TO SERVICE.Mar 8, 2019 · N636QX · Emb ERJ170200LRSDR DALA2019030401385Oven · smokeON CLIMBOUT STRONG SMELL OF BURNING FOOD-FA VERIFIED THAT THE GALLEY OVEN HAD VERY LIGHT VISIBLE SMOKE EMITTING FROM IT WITH STRONG SMELL-FOLLOWED SMOKE FIRE FUMES QRH ISOLATED GALLEY OVEN AND CONTINUED OPS NORMAL. POSITIVELY IDENTIFIED F/C OVEN AS SOURCE - REMar 3, 2019 · N959DL · Doug MD88SDR CA190319012Coffeemaker · arced(CAN) COFFEE MAKER MADE A SPARK WHICH SMELLED LIKE BURNT ELECTRONICS. THE FA PULLED BREAKERS, THERE WAS NO SMOKE. MAINTENANCE ASSESSMENT/RECTIFICATION INSPECTED COFFEE MAKER, FOUND THAT THE UNIT WAS ARCING INTERNALLY. THE NEW UNIT WAS REPLACED AND TESTED IAW AMar 2, 2019 · Bombdr DHC8400SDR AALA2019030549023Latch · lack of lubeFLIGHT CREW REPORTED THE GARBAGE COMPARTMENT DOOR IN THE FWD GALLEY OPENS ON LANDING AND DISARMS THE GIRT BAR ON THE FWD RT DOOR. LUBRICATED THE LATCHES ON TRASH CAN DOOR. LATCHES CHECK OK.Mar 1, 2019 · N301PA · Boeing 737823SDR AALA2019030549017Bulb · burned outF/A REPORTED THE CHILLERS WERE TURNED OFF BECAUSE OF AN ODOR. THE AIRCRAFT WAS GROUNDED. MAINTENANCE ACCOMPLISHED CARD 26L00021001 AND FOUND THE CHILLER OPERATION LIGHT BURNED OUT. REMOVED AND REPLACED THE BULB. OPS TESTED GOOD.Mar 1, 2019 · N756US · Airbus A319112SDR ASOA201902274010Coffeemaker · odorPVD - FLIGHT 4870 THE CREW REPORTED A BURNED WIRE INSULATION SMELL COMING FROM COFFEE MAKER AREA, AND THAT THE SMELL WENT AWAY AFTER BOTH COFFEE MAKERS WERE TURNED OFF. THE AIRCRAFT LANDED IN PVD WITHOUT INCIDENT WHEFRE CONTRACT MAINTENANCE PERFORMED AN ABMNORFeb 27, 2019 · N16981 · Emb EMB145LRSDR GTIA2019022703192Unknown · smokeF/A REPORTS FRONT COFFEE POT WAS SMOKING WAS A WHITE SMOKE. AND SMELLED LIKE 'BURNING WIRES'. F/AS PULLED THE CIRCUIT BREAKER FOR COFFEE POT-REMOVED FWD GALLEY COFFEE POT, INSPECTED COFFEE POT, REINSTALLED COFFEE POT AND PREFORMED OPS CHECK IAW AMM 25-35-00. OFeb 27, 2019 · N507NK · Airbus A319132SDR ASAA2019022748342Coffeemaker · failedAFT COFFEE MAKER WAS TURNED ON SPARKS AND A FLAME WAS OBSERVED AND THEN WAS IMMEDIATELY TURNED OFF. GROUNDED - YES. R/R AFT COFFEE MAKER IAW AMM 25-35-15, OPS CHECK GOOD, THIS CLEARS MDDR 64117, NEF LIST UPDATED, MCC NOTIFIEDFeb 24, 2019 · N361VA · Airbus A320214SDR DALA2019022101084Coffeemaker · failedCOFFEMAKER NO.2 C/B POPPED. F/A'S BRIEFLY SMELLED SMOKE WHICH DISAPPATED QUICKLY WITH NO SMOKE. SEE LOG NO. 0952604. REPLACED COFFEMAKER NO.2 BY L-1 DOOR PER MD88 AMM 25-36. LK AND OPS CK GOOD. (LP4885180)Feb 20, 2019 · N991DL · Doug MD88SDR AALA201902229027Oven · contaminatedODOR FROM ROW 3 FORWARD FA SAID SMELLED LIKE BURNING PLASTIC, HAD IRRITATED EYES AND THROAT. THE AIRCRAFT WAS GROUNDED. ACCOMPLISHED MCM CARD 05-96-70. FOUND MELTED PLASTIC IN OVEN. REPLACED NR 2 OVEN.Feb 18, 2019 · N304RB · Boeing 7378SDR AALA201902220004Oven · contaminatedODOR FROM ROW 3 FORWARD FA SAID SMELLED LIKE BURNING PLASTIC, HAD IRRITATED EYES AND THROAT. THE AIRCRAFT WAS GROUNDED. ACCOMPLISHED MCM CARD 05-96-70. FOUND MELTED PLASTIC IN OVEN. REPLACED NR 1 OVEN.Feb 18, 2019 · N304RB · Boeing 7378SDR UIEA2019021873240Coffeemaker · failedAT CRUISE, FL 330, HEARD A LOUD "POP" SOUND FROM THE GALLEY AREA. IT WAS IMMEDIATELY FOLLOWED BY AN ELECTRICAL FIRE SCENT. NO SMOKE WAS OBSERVED.(<P>INSPECTED GALLEY AND ALL ELECTRICAL APPLIANCES FOR OPERATION, ALL CHECKED NORMAL. ALL LIGHTS AND OUTLETS WORKEDFeb 17, 2019 · N412MC · Boeing 74747UFSDR CALA2019021700265Coffeemaker · odorFLIGHT ATTD REPORTED BURNING SMELL FROM AFT GALLEY REFERENCE FIM 21-00-00-810-806 RAN APU AND ENGINES WITH BLEED SOUCES ISOLATED FOUND NO OIL SMELLS IN CABIN OR COCKPIT AREAS. STUDIED SMOKE/ODER QUESTIONAIRE FILLED OUT BY FLIGHT ATTENDANT AND FLIGHT CREW. NARRFeb 16, 2019 · N24224 · Boeing 737824SDR SWAA2019021429617Coffeemaker · faultyDURING CLIMB, FLIGHT ATTENDANTS REPORTED A LOUD POP FROM THE AREA AROUND THE AFT SERVICE DOOR. THIS WAS FOLLOWED BY A SMELL LIKE BURNT RUBBER OR TIRES SMELL AS PRECAUTION WE SHUT DOWN GALLEY POWER. SMELL SLOWLY DISSIPATED. R&R AFT COFFEE MAKER PER MM.Feb 13, 2019 · N7750A · Boeing 7377BDSDR CALA2019021100240Oven · wornF/A REPORT BURNING SMELL SUSPECT OUTLET AT 4L TURNED OFF UTILITY BUS SMELL ABATED. SMOKE/ODOR QUESTIONNAIRE CARRIED OUT WITH CREW, CREW VERBAL "AFTER CYCLING UTILITY BUSES" NO SMELL NOTED, OVEN 3 FOUND TO HAVE EXCESSIVE CARBON/ BURNT SOOTY DEPOSITS AROUND FAN Feb 10, 2019 · N12114 · Boeing 757224SDR AALA201902119006Oven · odorDURING DESCENT, THROUGH 6000 - 2000 FEET, A STRONG VAPORIZED OIL ODOR IN THE FWD CABIN AND COCKPIT, BUT NOT AFT CABIN. RECIRCULATION FAN TURNED OFF, SOME TIME AS DISSIPATION NOT SURE IF RELATED. ACCOMPLISHED CARD 05-96-70. THE AIRCRAFT WAS GROUNDED. FOUNDFeb 10, 2019 · N310RF · Boeing 7878SDR AALA201902109001Oven · smokeAIRCRAFT WAS NOT GROUNDED: OVEN NR 4 BUSINESS CLASS WAS HEATING A MEAL, WHEN DOOR WAS OPENED SMOKE WAS DISCOVERED. DOOR WAS SHUT, POINTER TURNED OFF, SOME ELECTRICAL SMELL WAS DETECTED. MAINTENANCE REPLACED NR 4 OVEN BUSINESS CLASS GALLEY PER AMM 25-35-19 AND Feb 7, 2019 · N115NN · Airbus A321231SDR AALA2019020109005Oven · odorFLIGHT ATTENDANTS REPORTED A PLASTIC, TENNIS SHOE, MILDEW ODOR IN THE CABIN AT 35,000 FEET. THE AIRCRAFT WAS GROUNDED. MAINTENANCE ACCOMPLISHED A CABIN ODOR TROUBLESHOOTING JC 26L00021001. MAINTENANCE IDENTIFIED THE SOURCE AS THE FORWARD GALLEY OVEN AND REPJan 29, 2019 · N833AW · Airbus A319132SDR DALA2019012800547Oven · defectiveSHIP 3361 - SMOKE/FUME EVENT - FLIGHT CREW REPORTED A SMOLDERING EMBER OF PAPER IN ONE OF THE MID GALLEY OVENS. F/A DISCHARGED A HALON FIRE EXTINGUISHER IN THE OVEN AS A PRECAUTION. CORRECTIVE ACTION: OVEN REPLACED. LP 0920312Jan 27, 2019 · N861NW · Airbus A330223SDR AALA201901249002Wire Harness · burnedFOUND A WIRE HARNESS BURNED. MAINTENANCE REPLACED BOTH SECTIONS IAW WDM 23-32-43.Jan 23, 2019 · N388AA · Boeing 767323SDR AALA2019011769004Oven · odorHAD A TRANSIENT BURNING ODOR JUST AFTER TAKEOFF, SIMILAR TO OVEN TURNING ON. DISSIPATED AFTER A FEW MINUTES. PERFORMED JC 19L00021001 IAW TSI 0081377. REPLACED THE NR 2 FORWARD GALLEY OVEN IAW AMM 25-31-05. OPS CHECKED GOOD. NO ABNORMAL ODOR NOTED AT THISJan 15, 2019 · N202UW · Boeing 7572B7SDR DALA2019011600273Oven · odorAT CRUISE AT FL350, F/A SMELLED ELECTRICAL SMELL BELIEVED TO BE FROM OVEN, C.B. PULLED, QRH PROCEDURE FOLLOWED. SMELL DISAPATED. REMVD OVEN, NO EVIDENCE OF DAMAGE WIRING OR SOURCE OF ODOR. SUSPECT INTERNAL ISSUE WITH OVEN. PULLED AND COLLARED C/B. OK. (LP48095Jan 15, 2019 · N909DE · Doug MD88SDR AALA201901149002Oven · odorOVEN 8A HAD AN ELECTRICAL ODOR WHEN IN USE. REPLACED THE 8A OVEN IAW DMC 25-32-00-10A-720AA. OPS CHECKED GOOD, OK FOR SERVICE.Jan 12, 2019 · N821AN · Boeing 7879SDR GTIA2019010803073Plate · dirtyFA REPORTS SMELL OF GASOLINE IN LAST 3 ROWS AND AFT GALLEY DURING CRUISE FLIGHT AT FL250-FOUND AFT GALLEY PLATE DIRTY IAW TSM 05-50-00-810-831-A CLEANED AS NECESSARY AND OP CK IAW AMM 25-35-00. OP CK GOODJan 8, 2019 · N644NK · Airbus A320232SDR DALA2019010900110Oven · smokeOVEN NEEDS TO BE CLEANED. BAD SMELL LIKE CLEANER AND SMOKE WHEN COOKING. C/W SMOKE/ODOR T/S PER W/C 2120-2367. VERIFIED FWD GALLEY OVEN INTERIOR SMELL AS SOURCE OF SMELL. REPLACED FWD GALLEY OVEN PER AMM 25-30. C/W ALL ODI REQUIREMENTS PER W/C 2120-2367. OVEN,Jan 8, 2019 · N954DL · Doug MD88SDR R61A201901040041Coffeemaker · odorBURNING SMELL DETECTED IN FLIGHT. DECLARED EMERGENCY, DIVERTED TO JFK, LANDED WITHOUT INCIDENT. FOUND TRACKS FOR BOTH COFFEE MAKERS DIRTY, CAUSING FUMES. R&R COFFEE MAKERS. R&R THE INBOARD AND OUTBOARD COFFEE BREWER RAIL ASSEMBLIES AS PER CMM 25-37-05.Jan 4, 2019 · N201JQ · Emb ERJ170200LRSDR AALA2019011039017Chiller · smokeFLIGHT ATTENDANT REPORTED SMOKE IN THE FORWARD GALLEY AREA. DIVERTED. INFLIGHT SHUTOFF OF THE GALLEY AND CABIN POWER SEEMED TO HELP. THE AIRCRAFT WAS GROUNDED. FOUND THE CHILLER IN FORWARD GALLEY TO BE THE SOURCE OF THE SMOKE. REPLACED THE CHILLER IAW AMM 2Jan 2, 2019 · N103NN · Airbus A321231SDR ASOA201901023001Coffeemaker · faultyTHE CREW REPORTED ELECTRICAL SMELL COMING FROM GALLEY, WENT AWAY WHEN COFFEE MAKERS WERE SHUT OFF. MAINTENANCE REPLACED COFFEE BREWER IN LT POSITION. OPS CHECK GOODJan 2, 2019 · N16987 · Emb EMB145LRSDR AALA201901039001Oven · smokeAIRCRAFT WAS NOT GROUNDED: OVEN SMOKES AND HAS BAD ODOR WHEN IN USE, COULD NOT USE. MAINTENANCE REPLACED NR 1 OVEN IN FIRST CLASS PER MM 25-32-02 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.Dec 31, 2018 · N814NN · Boeing 737823SDR SCNA20181227149Coffeemaker · malfunctionedAFT COFFEE MAKER SHUT OFF DUE TO POSSIBLE SMOKE. REMOVED AND REPLACED COFFEE MAKER IN AFT GALLEY. OPS CHECK OK.Dec 27, 2018 · N817SY · Boeing 7378K2SDR GTIA2018122873050Coffeemaker · odorBURNING SMELL IN FORWARD GALLEY IN FLIGHT.-UPON INSPECTION FOUND BURNING SMELL COMMING FROM FWD COFFEE MAKER NO C/B TRIPPED CURRENTLY NO ECAM WARNING IAW TSM 24-00-00-810-823-A FOR CORRECTION ACTION OF COFFEE MAKER DEFERAL SEE LOG PAGE # 2433456-2 INSPECTIONS Dec 27, 2018 · N624NK · Airbus A320232SDR DALA2018122607418Chiller · odor(LOG 0877436) INBOUND, CREW REPORTED ELECTRICAL ODOR FROM THE CHILLER. MAINTENANCE REPLACED FWD GALLEY CHILLER PER B737 AMM 25-31. OPS CK GOOD.Dec 25, 2018 · N395DN · Boeing 737832SDR ASOA201812313080Coffeemaker · faultyTHE CREW REPORTED STRONG ELECTRICAL SMELL IN GALLEY. MAINTENANCE INSPECTED AND REPLACED BOTH GALLEY COFFEE MAKERS.Dec 21, 2018 · N17108 · Emb EMB145XRSDR AALA201812189009Chiller · odorFLIGHT ATTENDANT REPORTED THAT WHEN TURNING ON THE CHILLER IN THE AFT GALLEY, IT GAVE OFF A CHEMICAL ODOR. ODOR WENT AWAY WHEN TURNED OFF. REPLACED THE CHILLER IAW AMM 25-34-51. OPS CHECKED GOOD. NO ODOR NOTED.Dec 14, 2018 · N708UW · Airbus A319112SDR UIEA2018121402834Hot Water Pot · shortedHOT CUP INOP. SHORTED WHEN PUSHED INTO THE SOCKET. CREW REPORTED SPARKS. TRANSFERRED TO DMI 104491 IAW DDG 25-20-01 NEF SECTION 4, GALLEY ITEM 2.Dec 14, 2018 · N658GT · Boeing 767281SDR DALA2018121317166Oven · failedON TAXI OUT FLIGHT ATTENDANT REPORTS SMOKE FROM FORWARD GALLEY OVEN 2 CIRCUIT BREAKERS PULLED AND HALO EXTINGUISHER USED. REPORT OF ELECTRICAL SMELL, RETURNED TO THE GATE. REPLACED FORWARD GALLEY #2 OVEN . SYSTEM OPERATION IS NORMAL.Dec 11, 2018 · N837MH · Boeing 767432ERSDR CALA2018120702522Coffeemaker · odorCREW REPORTED FLT ATTD HEARD LOUD POP FROM AFT SIDE OF RIGHT FWD GALLEY, FOLLOWED BY A BURNT ELECTRICAL SMELL. NO VISIBLE SMOKE OBSERVED. NO CB''S FOUND POPPED. CAPT PULLED CB''S FOR COFFEE MAKERS AND WARMER. SMELL QUICKLY DISSIPATED. FORM FOR FLT CREW TO COMPDec 6, 2018 · N659UA · Boeing 767322SDR CALA2018120702521Coffeemaker · odorCREW REPORTED FLT ATTD HEARD LOUD POP FROM AFT SIDE OF RIGHT FWD GALLEY, FOLLOWED BY A BURNT ELECTRICAL SMELL. NO VISIBLE SMOKE OBSERVED. NO CB''S FOUND POPPED. CAPT PULLED CB''S FOR COFFEE MAKERS AND WARMER. SMELL QUICKLY DISSIPATED. FORM FOR FLT CREW TO COMPDec 6, 2018 · N659UA · Boeing 767322SDR SWAA2018121027513Coffeemaker · faultyFORWARD GALLEY BRIEF ELECTRICAL SMELL IN FLIGHT DISSIPATED A FEW MINUTES. R&R COFFEE MAKER PER AMM.Dec 5, 2018 · N8557Q · Boeing 7378H4SDR SWAA2018121027417Coffeemaker · faultyDIVERSION/DECLARED EMERGENCY, CABIN CREW REPORTED SMOKE RUBBER ACRID SMELL IN THE FORWARD AND AFT CABIN AT CRUISE ALTITUDE. R&R AFT COFFEE MAKER PER MM.Dec 4, 2018 · N7708E · Boeing 73776NSDR CALA2018120702503Oven · contaminatedACRID ELECTRICAL SMELLTHROUGHOUT CABIN AFTERTAKEOFF. RAN CHEKLI STRETURND TOAIRPORT PERFORMED SMOKE/ODOR IN CABIN INSPECTION REF AMM 05-51-10-200-801C. CREW COMPLETED SMOKE/ODOR FORM AND INFORMED M/X THAT SMELL BEGAN DURING TAKEOFF. PERFORMED IDENTIFICATION CDec 3, 2018 · N429UA · Airbus A320232SDR DALA2018120306976Oven · smokeAIRCRAFT 3320 SMOKE COMING FROM MID CABIN NBR 2 OVEN. REPLACED MID CABIN NBR 2 OVEN. LP 0847487Dec 1, 2018 · N820NW · Airbus A330323SDR ASAA2018113027180Oven · odorAIRCRAFT RIGHT AFT RIGHT HAND OVEN BEGAN TO HEAT UP AND EMIT A HOT ELECTRICAL SMELL AFTER HAVING BEEN TURNED OFF FOR 45 MINUTES HOT ELECTRICAL SMELL STOPPED AFTER PULLING OVEN CIRCUIT BREAKERS. GROUNDED - YES. RESET C/B'S FOR AFT GALLEY OVENS. TURNED ON OVEN ANov 30, 2018 · N563AS · Boeing 737890SDR CALA2018111702392Oven · unsecureAIR RETURN AND DECLARED EMERGENCY DUE TO CREW REPORTING IN CLIMBOUT A FWD GALLEY OVEN (109) BECAME DETACHED AND SLID OUT OF POSITION. FLT ATTD MANAGED TO PUSH BACK INTO PLACE, BUT UNABLE TO SECURE IT IN PLACE. MX INSPECTED OVEN AND OPS CHKED. NO FAULTS NOTED.Nov 17, 2018 · N644UA · Boeing 767322SDR CALA2018111402369Oven · unsecureAIR RETURN DUE TO OVEN WORKING ITSELF LOOSE. TOMC REQUESTS OVEN 109 TO BE REPLACED DUE TO HISTORY. REPACED OVEN 109 AS REQUESTED PER TOMC AS PER REF AMM 25-31-00. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1219170 SN OFF 1080 OVEN, STEAM, OFF 99-2534-9-000Nov 14, 2018 · N644UA · Boeing 767322SDR CALA2018111402375Chiller · inoperativeFWD EQPMT SMOKE LIGHT IN FLIGHT. COMPLIED W QRH. AFTER 20M SMOKE LGHT WENTOUT PILOT REPORTED FWD GALLEY OVENS LOST POWER WELL THE SMOKE LIGHT REMOVED POWER FROM L1 GALLEY REF AMM 24-23-00-001 PG 11 STEP G.2 WAS ILLUMINATED. SUSPECT BPCU SENSED AN OVERLOAD CONDNov 14, 2018 · N76064 · Boeing 767424ERSDR RAIA2018110129001Coffeemaker · shortedSMOKE IN GALLEY COMIMG FROM COFFEE MAKER AREA. F/A DISCHARGED FIRE EXTINGUISHER. A/C LANDED IN ROC AND WAS FARRIED TO ORD FOR MX. R&R COFFEE MAKER AND PORTABLE FIRE EXTINGUISHER. ALSO R&R COFFEE MAKER RAIL AND FUSE. ALL OPS CHECKS GOOD.Oct 29, 2018 · N21129 · Emb EMB145XRSDR AALA2018101769013Oven · smokeNR 2 OVEN IN THE FORWARD GALLEY WAS PRODUCING SMOKE FROM UNKNOWN SOURCE. MAINTENANCE REPLACED THE OVEN IAW AMM 25-35-19-000, 400-003-A, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.Oct 13, 2018 · N559UW · Airbus A321231SDR HALA2018100900484Oven · malfunctionedMID GALLEY OVEN SMELLED LIKE BURNING AND WOULD NOT COOL DOWN. UTILITY BUSES WERE RESET AND GALLEY OVEN COOLED DOWN AND DIDN'T SMELL LIKE BURNING. RAN OVENS AT HIGH FOR 20 MIN. DIDN'T NOTICE ANYTHING UNUSUAL, REINSTALLED DOOR SEAL THAT WAS AJAR. OPERATES NORMALOct 8, 2018 · N582HA · Boeing 76733AER
Back to JASC 2530