Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DXTA2017030206377Coffeemaker · failedON DESCENT INTO DESTINATION, SMELLED AN ODOR. ON SHUTDOWN THE COFFEE POT AS WELL AS THE WATER POT WERE EXTREMELY HOT WITH THE SWITCHES IN THE OFF POSITION. INSPECTED SWITCHES, WIRING AND CONNECTORS FOR UPPER AND LOWER HOT LIQUID TANKS. NO DEFECTS NOTED. FOUNSDR CALA2017022400467Oven · faultyOVEN IN FIRST CLASS GALLEY SMOKING. F/A CUT POWER TO OVEN AND SMOKE DISSIPATED. REMOVED AND REPLACED OVEN. REF AMM 25-34-00-000-801C3. OPS CHECKED NORMAL.SDR SIMA20170223001Heater · failedDURING DESCENT BELOW 20,000, F/A 1 CALLED WITH AN ACCETONE TYPE AROMA IN GALLEY AREA. BOTH F/A 1&2 ADVISED OF AN ELECTRICAL ODOR BEGINNING AROUND ROW 6 AND ALSO IN FRONT OF LAVATORY. COMPLIED WITH CABIN ABNORMAL ODOR FIM TASK 21-22-00-810-806. IN PROCESS, FOSDR AALA20170222019Oven · odorAIRCRAFT WAS NOT GROUNDED. OVEN 1F/C08 DOES NOT HEAT PROPERLY AND HAS A CHEMICAL ODOR DURING USE. REMOVED AND REPLACED OVEN IAW AMM 25-32-00. OPERATIONAL CHECK GOOD.SDR DALA2017022101465Counter · corrodedGALLEY 4 FILLER AT THE COUNTER TOP WAS FOUND SEVERELY CORRODED. MANUFACTURED NEW FILLER FROM DRAWING 257013 REV C SHEETS 1 AND 9 IAW ENGINEERING REPAIR AUTHORIZATION N: 06-494005-14MA REV B.SDR DALA2017021701325Coffeemaker · smokeNR 2 COFFEEMAKER SMOKING WHEN ON, BUT NOT BREWING; TURNED OFF, SMOKE STOPPED. REPLACED THE COFFEEMAKER.SDR AALA201702159013Oven · odorCREW COMPLAINS OF ODOR. FOUND AN ODOR COMING FROM FWD GALLEY OVEN. REMOVED AND REPLACED OVEN.SDR CALA2017021300354Oven · faultyAFT GALLEY OVEN R42 POPPED ITS CB AS IT WAS PUT UNDER LOAD FOR REPORTED BURNING SMELL IN CABIN. INSTALLED SERVICEABLE OVEN OPS CHECK GOOD.SDR AALA20170220028Oven · smokeAIRCRAFT WAS NOT GROUNDED. NR 1 FIRST CLASS OVEN SMOKES AT ALL TEMPERATURE SETTINGS. REMOVED AND REPLACED OVEN IAW AMM 25-30-00. SYSTEM CHECKS NORMAL.SDR CALA2017021200331Oven · defectiveELECTRICAL BURNING SMELL THROUGHOUT CABIN. NO SMOKE PULLED FWD AND AFT GALLEY BREAKERS, APPLY POWER TO GALLEYS. TURNED ONE GALLEY DEVICE AT A TIME. FOUND NO FAULTS OR ODORS IN FORWARD GALLEY. AFT GALLEY DID PRESENT SOME HEAT/OVERHEAT ODORS AT TIMES, NOT ELESDR DALA2017020701031Chiller · odorRETURNED TO THE GATE DUE TO REPORTED ODOR IN THE CABIN ON TAXI OUT. FOUND THE AFT GALLEY CHILLER NR 1 AS THE SOURCE OF THE ODOR. REPLACED AFT GALLEY NR 1 CHILLER PER AMM 25-33. OPS CHECKS NORMAL.SDR AALA20170207007Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED. STRONG ELECTRICAL/BURNING PLASTIC ODOR NOTED IN THE FIRST CLASS GALLEY. REMOVED AND REPLACED ESPRESSO MAKER. OPERATIONAL CHECK GOOD.SDR AALA201702059011Oven · odorFLIGHT ATTENDANT REPORTED FWD GALLEY LEFT OVEN HAS AN ELECTRICAL ODOR. REMOVED AND REPLACED FWD GALLEY OVEN.SDR CALA2017020300249Oven · sparksOVEN SMOKING OR SPARKING 222. THE OVEN WAS REPLACED, OPS CHECKED NORMAL.SDR DALA2017020200954Oven · inoperativeFUME FORWARD GALLEY OVEN INOPERATIVE WITH ASSOCIATED ELECTRICAL SMELL. PULLED OVEN CIRCUIT BREAKER AND SMELL DISSIPATED. MAINTENANCE REPLACED OVEN. OPS CHECK OK.SDR CALA2017013000199Oven · dirtyFWD GALLEY OVEN BELOW POS205 SMOKES DURING OPERATION. RECOMMEND CLEANING. CLEANED OVEN NO SMOKE NOTED DURING OPERATION AT THIS TIMESDR CALA2017013000200Oven · odorOVEN SMELLS BAD AFT GALLEY BOTH OVENS WHEN TURNED ON. BOTH HAD A PLASTIC BURNING SMELL. TURNED OFF FOR INSPECTED OVENS AND CYCLED FOR SEVERAL MINUTES, NO ISSUE FOUND.SDR AALA20170207004Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED. ESPRESSO MAKER NR 1 IN THE FIRST CLASS GALLEY HAS AN ELECTRICAL ODOR WHEN TURNED ON. REMOVED AND REPLACED ESPRESSO MAKER IAW AMM 25-32-01. LEAK AND OPERATIONAL CHECK GOOD.SDR CALA2017012900184Oven · dirtyON CLIMBOUT BURNING SMELL SENSED. FLIGHT ATTENDS REPORTED BURNING SMELL IN CABIN COMPLIED WITH SMOKE SMELL IN CABIN FOUND FOUR OVENS IN AFT GALLEY WITH BURNT FOOD, CLEANED OVENS AND CHANGED BOTH RECIRCULATION AIR FILTERS AND PERFORMED BOTH ENGS RUNS NO BURN SSDR AALA201701299002Oven · overheatedAT 4000 FEET ON APPROACH , FLIGHT ATTENDANTS NOTED THAT DIRTY SOCK , METALLIC ODOR OCCURED AT THE 2L/R DOORS. MAINTENANCE FOUND NR 1 MID GALLEY OVEN OVERHEATING CAUSING ODOR PER JOB CARD 33L00021001. REPLACED MID GALLEY OVEN NR 1 IAW AMM 25-35-19. AIRCRAFT WASDR AALA20170125012Oven · smokeAIRCRAFT WAS NOT GROUNDED. FLIGHT ATTENDANT REPORTED SMOKE ABOVE FORWARD GALLEY OUTBOARD OVEN AND IMMEDIATELY TURNED IT OFF. SMOKE AND ODOR DISSIPATED AFTER OVEN WAS SHUT OFF. ODOR WAS A MIXTURE OF PLASTIC AND ELECTRICAL. REMOVED AND REPLACED OVEN IAW AMM 25-3SDR AALA20170202026Oven · odorAIRCRAFT WAS GROUNDED. DURING APPROACH BOTH PILOTS REPORTED AN ACRID ODOR. MAINTENANCE ACCOMPLISHED CARD 05-96-07. FIRST CLASS OVEN DETERMINED TO BE SOURCE OF ODOR. REMOVED AND REPLACED OVEN IAW AMM 25-32-02. SYSTEM CHECKS NORMAL.SDR DALA2017012200523Coffeemaker · leakingFLIGHT ATTENDANT REPORTED BURNT RUBBER SMELL IN B/C CABIN. SEEMED TO MOVE FROM ROW 2 TO ROW 8, RIGHT SIDE. CABIN LIGHTS TURNED OFF, SMELL WENT AWAY. CABIN WALK THROUGH, NO SMELL AT ALL. NEVER ANY SMOKE PRESENT. SEE SMOKE QUESTIONNAIRE. T/S BURNT RUBBER SMELL. SDR REXA2017011800050Oven · odorBURNING ODOR IN GALLEY JUST AFTER LANDING. OVEN AND COFFEEMAKERS WERE OFF. REMOVED AND REPLACED GALLEY OVEN IAW AMM 25-32-01. OPS CHECKED PERFORMED SATISFACTORY IAW AMM 25-32-01.SDR AALA201701179019Coffeemaker · odorAIRCRAFT WAS GROUNDED: FLIGHT CREW REPORTED DURING DECENT AND APPROACH DETECTED AN ODOR LIKE BURNT METAL ON TOAST, BETWEEN ROW 6-7, OF THE MID CABIN. MAINTENANCE NOTED SMELL IN MID GALLEY OVEN AND EXPRESSO MAKER AREAS. 2 MID GALLEY OVENS, 2 COFFEE MAKERS AND 2SDR AALA201701179018Oven · odorAIRCRAFT WAS GROUNDED: FLIGHT CREW REPORTED DURING DECENT AND APPROACH DETECTED AN ODOR LIKE BURNT METAL ON TOAST, BETWEEN ROW 6-7, OF THE MID CABIN. MAINTENANCE NOTED SMELL IN MID GALLEY OVEN AND EXPRESSO MAKER AREAS. 2 MID GALLEY OVENS, 2 COFFEE MAKERS AND 2SDR AALA201701179017Coffeemaker · odorAIRCRAFT WAS GROUNDED: FLIGHT CREW REPORTED DURING DECENT AND APPROACH DETECTED AN ODOR LIKE BURNT METAL ON TOAST, BETWEEN ROW 6-7, OF THE MID CABIN. MAINTENANCE NOTED SMELL IN MID GALLEY OVEN AND EXPRESSO MAKER AREAS. 2 MID GALLEY OVENS, 2 COFFEE MAKERS AND 2SDR AALA20170103005Oven · faultyAIRCRAFT WAS GROUNDED. EMERGENCY DECLARED. DFW-JAC FLIGHT DIVERTED TO OKC ACCOUNT METALLIC ODOR IN COCKPIT, FIRST CLASS GALLEY AND CABIN. LANDING UNEVENTFUL. REMOVED AND REPLACED NR 1 GALLEY OVEN (AALA20161230025) AND NR 2 GALLEY OVEN IAW AMM 25-35-19. OPERATISDR AALA20161230025Oven · faultyAIRCRAFT WAS GROUNDED. EMERGENCY DECLARED. DFW-JAC FLIGHT DIVERTED TO OKC ACCOUNT METALLIC ODOR IN COCKPIT, FIRST CLASS GALLEY AND CABIN. LANDING UNEVENTFUL. REMOVED AND REPLACED NR 1 GALLEY OVEN AND NR 2 GALLEY OVEN (AALA20170103005) IAW AMM 25-35-19. OPERATISDR GTIA2016122801721Coffeemaker · inoperativeA PLUME OF SMOKE AND A BURNING RUBBER ODOR IN AFT GALLEY REPORTED BY FLT ATTENDANT. INSPECTED THE ACFT IAW TSM 05-50-00-810-831A, REMOVED, INSPECTED AND INSTALLED AFT GALLEY COFFEEMAKER, PERFORMED OPS TEST OF HOT PLATE , WORKED NORMAL, OPENED AND INSPECTED ASDR DALA2016122910134Coffeemaker · odorENROUTE, DIVERTED DUE TO FLIGHT ATTENDANTS REPORTING AN ELECTRICAL ODOR IN THE FIRST CLASS CABIN. MAINTENANCE FOUND A FORWARD GALLEY COFFEEMAKER HOT PLATE WAS BURNING COFFEE AND CAUSING ELECTRICAL ODOR. THE COFFEE MAKER WAS DEFERRED PER NEF (LP# 9480325) ANSDR AALA20161228010Coffeemaker · faultyMID GALLEY COFFEEMAKERS EMITTED A BURNING ODOR WHEN NOT BREWING. REMOVED AND REPLACED THE NR 3 AND 4 COFFEEMAKERS IAW AMM 25-32-00. OPERATIONAL CHECKED GOOD.SDR AALA20161228009Coffeemaker · faultyMID GALLEY COFFEEMAKERS EMITTED A BURNING ODOR WHEN NOT BREWING. REMOVED AND REPLACED THE NR 3 AND 4 COFFEEMAKERS IAW AMM 25-32-00. OPERATIONAL CHECKED GOOD.SDR AALA20161227006Oven · smokeFORWARD GALLEY OVEN NR 2 OVERHEATED AND EMITTED A SMALL AMOUNT OF SMOKE. REMOVED AND REPLACED OVEN IAW AMM 25-32-02. OPERATIONAL CHECK GOOD.SDR AALA201612229006Coffeemaker · failedGALLEY 3 AFT COFFEEMAKERS CIRCUIT BREAKER PULLED DUE TO STRONG ELECTRICAL ODOR. MAINTENANCE FOUND THE NR 1 COFFEEMAKER TRIPPING BREAKER AND REPLACED IAW AMM 25-35-15 AND RESET ALL THREE BREAKERS.SDR AALA20161222003Coffeemaker · sparksAFT GALLEY NR 2 COFFEEMAKER SPARKED DURING FLIGHT. COFFEEMAKER WAS TURNED OFF AND IT WAS NOTED THAT THE BREAKER HAD TRIPPED. REMOVED AND REPLACED THE COFFEEMAKER IAW AMM 25-32-00. OPERATIONAL CHECKED GOOD.SDR AALA20161221007Oven · firePRIOR TO PUSHBACK, FLIGHT ATTENDANT REPORTED A FIRE IN THE FORWARD GALLEY NR 2 OVEN. ELECTRICAL POWER WAS SHUT OFF AND FIRE EXTINGUISHED INSIDE OVEN. CLEANED THE OVEN IAW AMM 25-35-00. OPERATIONAL CHECKED GOOD.SDR DALA2016122710074Oven · smokeF/A REPORTS SMOKE COMING FROM NR 2 OVEN WHEN POWER APPLIED.REMOVED PWR AND SMOKE WENT AWAY. REPLACED FWD GALLEY 2 OVEN. OPS NORMAL.SDR SIMA20161218001Heater · failedFLT ATT ODOR ELECTRIC FIRE BREWING GALLEY AREA ON CLIMB OUT. DECLARED EMERGENCY. INSPECTED GALLEY AREA IAW CRJ-FIM-21-23-64. REMOVED AND REPLACED GALLEY HEATER IAW AMM-21-23-64.SDR AALA20161215001Microwave Oven · odorMICROWAVE IN FORWARD GALLEY REPORTED BY CREW TO HAVE ELECTRICAL ODOR. CIRCUIT BREAKER PULLED AND COLLARED FOR MICROWAVE. REMOVED AND REPLACED G1 MICROWAVE IAW AMM 25-33-01. OPERATIONAL CHECK GOOD.SDR AALA20161214011Oven · odorBOTH FORWARD GALLEY OVENS OMIT A LIGHT SMOKE AND ODOR WHEN HEATED. REMOVED AND REPLACED DOUBLE OVEN IAW AMM 25-32-02. OPERATIONAL CHECKED GOOD.SDR AALA20161214006Coffeemaker · odorDURING DESCENT, FLIGHT ATTENDANT NOTICED BURING ODOR FROM GALLEY ELECTRICAL PANEL. FIRST CLASS GALLEY MASTER POWER SWITCH TURNED OFF AND ODOR DISSIPATED WITH VENTS OPEN. AIRCRAFT WAS GROUNDED. REMOVED AND REPLACED THE COFFEEMAKER AND ESPRESSO MACHINE IAW CMMSDR AALA201612109009Oven · contaminatedAIRCRAFT WAS NOT GROUNDED. BOTH FIRST CLASS OVENS SMOKE WHEN HEATED UP. MAINTENANCE FOUND MELTED/BURNED PLASTIC AND TAPE ON OVEN INSERT. REMOVED INSERT AND RAN OVENS THROUGH HEAT CYCLE. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA20161213019Oven · contaminatedAIRCRAFT WAS NOT GROUNDED. DURING TAXI OUT A FLIGHT ATTENDANT REPORT SMOKE AND FIRE IN THE FIRST CLASS NR 1 OVEN. MAINTENANCE FOUND A PIECE OF PAPER TAPED TO THE BACK OF THE OVEN RACK. REMOVED AND REPLACED OVEN IAW AMM 25-35-19. OPERATIONAL CHECK GOOD.SDR AALA20161208008Oven · fireFORWARD GALLEY OVEN FIRE. REMOVED AND REPLACED THE NR 1 OVEN IAW AMM 25-35-19. OPS CHECKED GOOD.SDR AALA201612069015Oven · odorFLIGHT ATTENDANTS REPORTED ODOR LIKE OVEN NR 2 OVERHEATING. NO SMOKE REPORTED. AIRCRAFT DECLARED AN EMERGENCY AND RETURNED TO DEPARTURE. AIRCRAFT WAS GROUNDED. MAINTENANCE REPLACED THE OVEN 1-7 AT FORWARD GALLEY IAW AMM 25-35-19.SDR AALA20161130013Coffeemaker · leakingAIRCRAFT NOT GROUNDED. DURING CRUISE ABOUT 3 HOURS INTO FLIGHT, FLIGHT ATTENDANT REPORTED A STRONG ELECTRICAL ODOR IN THE RIGHT FORWARD AREA OF THE GALLEY DUE TO ESPRESSO MAKER LEAKING. REMOVED AND REPLACED ESPRESSO MAKER IAW AMM 25-32-01. OPERATIONAL CHECKSDR AALA20161130007Oven · faultyAIRCRAFT NOT GROUNDED. METALLIC BURNING ODOR EMITTED FROM NR 4 OVEN IN MID GALLEY WHEN TURNED ON HIGH. REMOVED AND REPLACED OVEN IAW AMM 25-35-19. OPERATIONAL CHECK GOOD.SDR AALA201611289001Coffeemaker · faultyAIRCRAFT WAS NOT GROUNDED. SECONDS AFTER TAKEOFF FLIGHT ATTENDANT AND PASSENGERS ALL SMELLED SMOKE IN FORWARD AND MID CABIN, DECLARED EMERGENCY AND RETURNED TO ORD. MAINTENANCE DETERMINED SMELL WAS FROM FORWARD GALLEY LOWER COFFEE MAKER. REPLACED COFFEE MAKER SDR SOKF20161128011Oven · odorDURING FLIGHT, THE AIRCRAFT RETURN TO DEPARTURE DUE TO A STRONG ODOR OF BURNING IN FWD GALLEY. PERFORMED TSM 05-50-00-810-831-A AND FOUND THE ODOR CAME FROM FWD GALLEY NR 1 OVEN. REMOVED AND REPLACED THE FWD GALLEY OVEN IAW AMM 25-35-19 AND OPS CHECKED IAW
Back to JASC 2530