SDR AALA20161123013Rail · dirtyAIRCRAFT NOT GROUNDED. FLIGHT ATTENDANT REPORTED SMOKE FROM COFFEE MAKER 2 OR 3 IN THE FIRST CLASS GALLEY. REMOVED AND REPLACED COFFEEMAKERS BUT ELECTRICAL ODOR STILL EVIDENT. BOTH RAIL ASSEMBLIES EXCESSIVELY DIRTY. CLEANED RAILS AND RERACKED COFFEEMAKERS.SDR AALA201611219006Oven · odorFWD GALLEY OVEN TURNED OFF DUE TO SMELL OF MELTING PLASTIC. R&R FWD GALLEY OVEN AS PER AMM 25-35-19-400-001-A OPS CK GOOD; REMOVE C/B COLLAR AND NEF FROM MIC SHEET. THE AIRCRAFT WAS NOT GROUNDED.SDR DALA2016111408767Oven · odorHOT PLASTIC/ELECT ODOR FROM 1L DOOR AREA, ENTERTAINMENT SYSTEM SHUTDOWN. OPERATED FWD GALLEY OVEN FOR 30 MINS, FOUND PLASTIC SMELL, REPLACE OVEN.SDR CALA2016111100882Oven · odorAIR RETURN, F/A AND PILOTS SMELLED ODOR REAR GALLEY. PULLED ALL CB AND REMOVED OVENS ODOR CONTINUES. ALL AFT GALLEY OVENS REPLACED. OVEN 411 - ELECTRICAL ODOR FAN SQUEALS, OVEN 412 - BURNT MATERIAL ON HEATING COIL, OVEN 413 - REPLACED AS PRECAUTION.SDR AALA201611109006Coffeemaker · sparksAIRCRAFT WAS NOT GROUNDED. FORWARD NR 1 COFFEEMAKER SPARKS WHEN TURNED ON, NOW INOPERABLE. REPLACED COFFEEMAKER PER AMM 25-35-15.SDR AALA20161108013Coffeemaker · faultyAIRCRAFT NOT GROUNDED. FLIGHT ATTENDANTS NOTICED RUBBER TYPE ODOR FROM A VENT NEAR CREW BUNK AREA. COFFEE MAKERS NR 10 AND NR 11 WERE TURNED OFF AND ODOR DISSIPATED. REMOVED AND REPLACED COFFEE MAKER 10. OPERATIONAL CHECK GOOD.SDR DALA2016110608418Coffeemaker · odorBURNING SMELL COMING FROM COFFEEMAKER G2B. R&R COFFEEMAKER AT G2B PER AMM 25-31.SDR AALA20161109004Chiller · overheatedACRID ODOR IN CABIN DUE TO AFT GALLEY CHILLER NR 1 OVERHEATING. REMOVED AND REPLACED CHILLER IAW AMM 25-33-03. OPERATIONAL CHECK GOOD.SDR AALA20161109005Oven · overheatedLIGHT SMOKE IN CABIN DUE TO FORWARD GALLEY OVEN NR 1 OVERHEATING. REMOVED AND REPLACED OVEN IAW AMM 25-35-19-401. OPERATIONAL CHECK GOOD.SDR DALA2016103108119Oven · smokeSMOKE DURING CLIMB A PUFF OF GREY SMOKE CAME OUT OF THE FORWARD OVEN. OVEN WAS TURNED OFF, CB OPENED AND SMOKE STOPPED. MAINTENANCE REPLACED THE FIRST CLASS OVEN PER AMM 25-31. NO FURTHER DEFECTS NOTED, AIRCRAFT RETURNED TO SERVICE.SDR AALA201610319002Oven · odorAIRCRAFT WAS NOT GROUNDED. OVEN NR 1 HAS STRONG ELEC SMELL MAYBE A BAD HEATING COIL. MAINTENANCE REPLACED THE NR 1 OVEN PER AMM 25-35-19.SDR DALA2016110108088Oven · smokeREPORTED STRONG ODOR OF SMOKE FROM UPPER DECK NUMBER ONE OVEN. THE OVEN CARRIER WAS REMOVED AND A HAND TOWEL WAS FOUND INSIDE AND VERIFIED TO BE THE SOURCE OF THE SMOKE ODOR. THE OVEN AND CONTROLLER WERE REPLACED.SDR AALA201611019012Oven · smokeAIRCRAFT WAS NOT GROUNDED. OVEN 1 FORWARD GALLEY SMOKING. REMOVED AND REPLACED FWD GALLEY OVEN NR 1 PER AMM 25-35-19-000-001.SDR DALA2016102807912Skate Angle · corrodedDURING INSPECTION FOUND G-4 LOWER SKATE ANGLES CORRODED. MAINTENANCE REPLACED G4 LOWER SKATE ANGLE WITH IAW AMM 25-31-41-400-801-005 STEP E NR 14.SDR AALA201610289014Oven · odorFORWARD GALLEY OVEN 1 HAS ELECTRICAL ODOR WHEN TURNED ON PREVIOUS LEG. OVEN NOT USED LAST LEG. MAINTENANCE REPLACED THE OVEN AND ACCOMPLISHED A SATISFACTORY OPS CHECK IAW AMM 25-35-19. AIRCRAFT WAS GROUNDED.SDR AALA201610289009Oven · malfunctionedNR 1 OVEN IN AFT GALLEY BECAME UNCONTROLLABLE HOT, PULLED CIRCUIT BREAKER AND HEAT SUBSIDED. MAINTENANCE REPLACED THE OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECKED IAW AMM 25-35-19.SDR DALA2016110208219Oven · malfunctionedOVEN EXPERIENCED AN ELECTRICAL FIRE AND BLEW A FUSE. PER FLIGHT ATTENDANT HE TURNED OVEN ON AND THE C/B TRIPPED. FOUND LEFT C/B OPEN. NO MENTION OF FIRE. INSPECTED OVEN AND FWD TO NEF 25-34-02. OVEN REPLACED. SYSTEM OPERATION IS NORMAL.SDR YENA20161023944Coffeemaker · failedPILOT REPORTED AN ELECTRICAL BURNING ODOR WHEN FRONT COFFEE POTS WERE ON. ODOR DISAPPEARED WHEN COFFEE POTS WERE DEACTIVATED. R & R FWD GALLEY NR 1 COFFEEMAKER IAW AMM 25-35-15. PERFORMED OPS TEST. OPS TEST PASSED.SDR SWAA2016102408982Coffeemaker · odorODOR REPORTED BY A FLIGHT ATTENDANT AND ODOR IN AFT GALLEY POSSIBLY FROM COFFEE MAKER. FOUND AFT INBOARD COFFEE MAKER BURNER CAUSED ODOR. R&R AFT COFFEE MAKER PER AMM.SDR CALA2016102400805Chiller · failedFORWARD GALLEY CHILLER LOUD BUZZING NOISE AND STRONG BURNING ODOR. VERIFIED FWD GALLEY CHILLER AT FAULT; HAD FLT. CREW COMPLETE FOR PLACARDED PER ABOVE MEL, C/W DDP, OK FOR SERVICE. M 46-6020-SMOKE ODOR QUESTIONAIRE, COLLARED BOTH FWD GALLEY CHILLER BREAKERSSDR AALA20161021001Chiller · odorDURING CLIMB FLIGHT ATTENDANTS REPORTED A STRONG ELECTRICAL BURNING ODOR FROM FORWARD GALLEY. NO EVIDENCE OF BURNING OR ODORS PRESENT ON ARRIVAL. EMERGENCY DECLARED. LANDING UNEVENTFUL. AIRCRAFT WAS GROUNDED. ACCOMPLISHED MCM CARD 05-96-70 WITH NO ODORS SDR AALA20161020008Oven · odorDURING CLIMB FLIGHT ATTENDANTS REPORTED A STRONG ELECTRICAL BURNING ODOR FROM FORWARD GALLEY. EMERGENCY DECLARED. LANDING UNEVENTFUL. AIRCRAFT WAS GROUNDED. NO EVIDENCE OF BURNING OR ODORS PRESENT ON ARRIVAL. ACCOMPLISHED MCM CARD 05-96-70 WITH NO ODORS SDR CALA2016101700760Oven · contaminatedSTRONG ACRID SMELL COMING FROM OVEN 423. REMOVED BURNT PAPER FROM OVEN 423 REF MM05 -51-26. INSPECTED OVEN 423, NO DEFECTS FOUND. OPS CKED OVEN FOR ABOUT 90 MIN AND COMPARED IT WITH OTHER OVENS, NO DEFECTS NOTED. OVEN 423 CKED NORMAL.SDR 4AER20161103006Sink · corrodedNUMBER 1 GALLEY SINK AND FLOOR AREAS HAD CORROSION.SDR ASOA20161003056Coffeemaker · failedTHE OUTBOARD COFFEE BREWER PRODUCES BURNING ODOR. REMOVED AND REPLACED THE COFFEEMAKER. OPS CHECKED GOOD.SDR AALA20161001005Oven · smokeDURING CRUISE SMOKE WAS REPORTED FROM MID GALLEY OVEN 4B. PORTABLE FIRE EXTINQUISHER WAS DISCHARGED INTO OVEN. NO FLAMES REPORTED. OVEN REPORTED TO BE OFF AT TIME OF INCIDENT. MAINTENANCE REMOVED AND REPLACED OVEN IAW MM 25-32-02. OPERATIONAL CHECK NORMAL.SDR CALA2016092900703Oven · contaminatedDUE TO STRONG ODOR REPORTED IN AFT CABIN AFTER TAKE OFF, ACCOMPLISH AN OPERATIONAL CONFIRMATION FLIGHT TO VERIFY NO DISCREPENCIES. RAN ENGINES AT HIGH POWR, ALL NORMAL, NO ODORS. PULLED ALL OVENS, COFFEEMAKERS AND CEILING PANELS OUT OF AFT GALLEY NO DEFECTSDR ASOA20160927073HCoffeemaker · smokeTHE CREW REPORTED A BURNING ODOR IN THE GALLEY. MAINTENANCE REMOVED AND REPLACED THE NR 2 COFFEE MAKER, OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SWAA2016092608081Coffeemaker · inoperativeAIR TURNBACK, DECLARED EMERGENCY AFTER DEPARTING FROM DSM, F/A REPORTED AN ACRID ELECTRICAL ODOR WITH NO SMOKE ASSOCIATED. RETURNED TO DSM, ODOR APPEARED TO DISSIPATE. FOUND FORWARD GALLEY COFFEEMAKER INOPERATIVE. R & R COFFEE MAKER IAW AMM.SDR AALA20160926004Coffeemaker · odorNR 1 COFFEEMAKER WAS PRODUCING AN ELECTRICAL ODOR. POWER TO COFFEEMAKER WAS TURNED OFF. MAINTENANCE REMOVED AND REPLACED THE COFFEEMAKER IAW AMM 25-32-00. OPS AND LEAK CHECKED NORMAL.SDR ASOA20160916048Coffeemaker · burned outCREW REPORTED A BURNING ODOR IN THE GALLEY AREA AND DID NOT INDICATE IF ON GROUND OR IN FLIGHT. MX REMOVED AND REPLACED NR 1 COFFEE BREWER WITH OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CALA2016091900657Unknown · odorAFT OVEN 412 GETTING AN ELECTRICAL ODOR WITH OVEN POWERED OFF. PULLED THE CIRCUIT BREAKER NO CHANGE. OVEN REMOVED AND AREA INSPECTED WITH NO FINDINGS OR ODOR. ALL OVEN CONTROLLER BOX UNPLUGGED AND CIRCUIT BREAKER PULLED AND COLLERED. OTHER GALLEY EQUIPMENT SDR AALA201609169014Oven · odorAIRCRAFT WAS NOT GROUNDED. OVEN NR 1 6-11, AFT GALLEY, MAKES POPPING NOISE AND HAS AN ELECTRICAL ODOR WHEN COOKING. MAINTENANCE REPLACED GALLEY OVEN PER AMM 25-35-19. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA20160921009Coffeemaker · odorFORWARD GALLEY ESPRESSO MAKER GIVES OFF A PLASTIC ODOR WHEN USED. MAINTENANCE REMOVE AND REPLACED ESPRESSO MACHINE IAW AMM 25-32-01.SDR AALA201609159011Coffeemaker · sparksSPARKS COMING FROM FRONT GALLEY COFFEEMAKER LEFT SIDE. REPLACED FORWARD GALLEY LEFT SIDE COFFEEMAKER IAW AMM 25-35-15 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201609069017Oven · odorAIRCRAFT WAS NOT GROUNDED, FORWARD GALLEY NR 2 OVEN EMITTING STRONG BURNING ODOR DURING OPERATION. SHUT OFF OVEN, NO FURTHER PROBLEM, NO SMOKE, RUBBER ODOR. REPLACED OVEN IAW AMM 25-31-41 AND ACCOMPLISHED A SATISFACTORY OPS CHECK.SDR ASAA2016082217780Oven · failedON TAXI OUT F/A REPORTED SPARKS IN GALLEY OVEN NR 2-4. ACFT GROUNDED. R & R FORWARD GALLEY OVEN WITH NEW, REF EMM 25-32-01, OPS CHECK OK.SDR DXTA2016082106284Coffeemaker · unserviceableA CRUISE ALTITUDE AND 45 MINUTES INTO FLIGHT ALL OCCUPANTS SMELLED A FOUL ODOR. WE TRACED IT TO THE COFFEE AND WATER POTS. ONCE POWER WAS TURNED OFF TO THE POTS THE ODOR WENT AWAY. R&R GALLEY COFFEE CONTAINER WITH AN OVERHAULED UNIT IAW MM CHAPTER 38-10-00 SDR ASOA20160818066Coffeemaker · defectiveTHE CREW REPORTED AN ELECTRICAL BURNING ODOR FROM THE LT COFFEE POT. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE R & R THE LT COFFEE BREWER, OPS TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CALA2016081200523Oven · odorOVEN IN AFT GALLEY HAD A BURNING ODOR. TURNED OVEN OFF, PULLED CIRCUIT BREAKER.SDR AALA20160817009Coffeemaker · odorDURING CRUISE, A BURNING ODOR WAS REPORTED IN THE L3/R3 DOOR AREA. FLIGHT ATTENDENTS PULLED THE CIRCUIT BREAKERS FOR COFFEEMAKERS. MAINTENANCE FOUND ODOR TO BE COMING FROM COFFEEMAKER NR 10. REMOVED AND REPLACED THE COFFEEMAKER IAW AMM 25-35-15. OPS CHECKESDR CALA2016080995611Oven · fireOVEN FIRE IN "B" GALLEY. FLAMES IN BACK OF OVEN CONTAINED WITH DOOR CLOSED. R & R OVEN AND CONNECTOR INSPECTION ACCOMPLISHED OK.SDR AALA201608059011Coffeemaker · odorAIRCRAFT WAS GROUNDED: F/A REPORTS AN AFT GALLEY ODOR OF PLASTIC OR BAND-AID ODOR THAT RESULTED IN FEELING NAUSEOUS AND A HEADACHE. ODOR WHILE AT THE GATE, DURING TAXI IN AND TAXI OUT. NOTE: ODOR WAS NOTED ONLY IN THE AFT GALLEY. MAINTENANCE REPLACED 2 AFT SDR AALA20160804009Oven · contaminatedDURING CLIMB, THE NR 1 FLIGHT ATTENDANT REPORTED A FIRE IN THE FORWARD GALLEY. EMERGENCY WAS DECLARED. FLIGHT ATTENDANT REPORTED THE FIRE WAS CONTAINED TO THE NR 1 OVEN, HAD BEEN EXTINGUISHED AND WAS CAUSED BY A CATERING INVENTORY SHEET THAT WAS TAPED TO THSDR CALA2016080100480Oven · contaminatedFWD GALLEY OVEN 204 STARTED TO SMOKE WHEN TURNED ON. FLIGHT ATTENDANT SAID THERE IS SOMETHING STUCK IN HEATING ELEMENT. SOURCE IDENTIFIED AS FOOD IN OVEN 204. COMPLIED WITH AMM 05-51-26 AND REPLACED OVEN 204 WITH NO OTHER DISCREPANCIES NOTED AT THIS TIME.SDR DALA2016080305747Coffeemaker · odorACFT HAD A SMOKE AND FUME EVENT. FLIGHT ATTENDANT REPORTED A HOT RUBBER ODOR IN FORWARD GALLEY INTO FIRST CLASS AT CRUISE AND DURING DESCENT. A SLIGHT HAZE NOTED IN FIRST CLASS. MAINTENANCE TROUBLESHOT AND FOUND COFFEEMAKER CIRCUIT BREAKERS TRIPPED AND FOUNSDR CALA2016080100477Oven · smokeDURING TAKEOFF ROLL, PLASTIC OR ELECTRICAL ODOR IN FLT DECK AND SMOKE AND ODOR IN CABIN. RETURNED TO DEPARTURE AND LANDED. FOUND OVEN IN FWD GALLEY WITH STRONG BURN ODOR. REMOVED AND REPLACED THE OVEN IAW AMM 25-34-00. REPLACED RECIRCULATION AIR FILTERS ISDR AALA201607309003Chiller · odorFLIGHT CREW REPORTED HOT ODOR LIKE MELTING PLASTIC OR WIRE COMING FROM AFT GALLEY. MAINTENANCE REPLACED THE AFT CHILLER IAW AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201607299047Coffeemaker · odorAFT FLIGHT ATTENDANT REPORTED ELECRICAL ODOR. SHUTOFF CHILLERS & COFFEE POTS, ODOR REMAINED IN AFT OF ACFT. MAINTENANCE ISOLATED THE ODOR TO THE LEFT AND RIGHT COFFEMAKERS AND COMPARTMENT WHICH WAS FILLED WITH SOOT. THE DEFECTIVE COFFEEMAKERS WERE REMOVED SDR SIMA20160723002Plate · dirtyBURNING ELECTRIC SCENT COMING FROM THE GALLEY AREA. INSPECTED GALLEY LIGHTS AND REPLACED BULBS REF AMM 33-26-01. FOUND NR 1 COFFEEMAKER HOT PLATE ON BURNING OLD COFFE RESIDUE ON EMPTY COFFEE JUG. CLEANED AREA PERFORMED OPC OF COFFEEMAKER REF AMM 25-32-06. N
Back to JASC 2530