SDR CALA2011112300765Oven · defectiveLAVATORY SMOKE CAME ON IN FLIGHT. APPEARS THAT SMOKE FROM AFT GALLEY COFFEEMAKERS AND HEATING UNITS ACTIVATED LAV LIGHT. CIRICUIT BREAKERS WERE PULLED ON AFFECTED ITEMS, SMOKE THEN CEASED ALL C/B RESET AND GALLEY EQUIPMENT TESTED WITHOUT FINDINGS. OVEN NR 2Nov 23, 2011 · N19130 · Boeing 757224SDR USAA2011112200003Oven · inoperativeCLT - NR 1 OVEN TEMP LIGHT COMES ON MID GALLEY AND HAS STRONG ODOR. MAINTENANCE REPLACED THE MID GALLEY OVEN NR 1 POSITION. OPERATIONAL AND LEAK CHECKS ARE SATISFACTORY PER TASK 25-35-19-991-001.Nov 20, 2011 · N278AY · Airbus A330323SDR CALA2011112100755Oven · dirtyAIR RETURN FOR UNDETERMINED OVEN SMOKE (OVER WEIGHT 117,800LBS LANDING). SMOKE FORM FILLED. DEBRIEFED F/A & FOUND AFT OVEN AT FAULT. OPS OVEN IN AFT GALLEY & FOUND SMOKING FROM SPILLAGE. PERF OVERWEIGHT INSP PER AMM737-5 CHAPT 05-51-74-201 NO DEFECT NOTED.Nov 19, 2011 · N14613 · Boeing 737524SDR UALA2011111706305Oven · faultyCREW REPORT: ODOR LIKE BURNT TOAST OR COFFEE AT DOOR 2L AND REAR CABIN. SAMC TEXT: CHECK BEHIND COFFEEMAKERS AND OVENS FOR EVIDENCE OF ARCING, INSIDE OVENS, COFFEEMAKERS AND HOTPLATES FOR POSSIBLE SOURCES OF SMOKE, ALSO CHECK LIGHTING BALLASTS FOR EVIDENCE Nov 17, 2011 · N847UA · Airbus A319131SDR UALA2011111806336Sink · unknownFWD GALLEY FLOODED WITH WATER. FOUND AN EXCESSIVE AMOUNT OF LIQUID DUMPED THRU FWD GALLEY TRASH SHOOT LEAKING DOWN THE SIDE OF TRASH CONTAINER. TRASH CAN LINER WAS NOT INSTALLED PROPERLY CAUSING FLUID TO LEAK ON THE SIDES OF THE TRASH CAN AND DOWN TO THE FLOONov 17, 2011 · N509UA · Boeing 757222SDR UALA2011112106344Plate · faultyGALLEY HOT PLATE WON'T HEAT AT 411H. CREW COMMENTS: WON'T HEAT. FWD GALLEY LOWER HOT PLATE H12 IS INOP. REPLACED HOT PLATE AT FWD GALLEY POSITION H12, OPS NORMAL.Nov 17, 2011 · N556UA · Boeing 757222SDR UALA2011111606283Oven · noisyCREW REPORTS FWD GALLEY OVEN (R12) FAN MAKING NOISE. NEEDS NEW OVEN- C-B PULLED AND COLLARED AND DOOR PLACARD. OVEN (028-9005) ITEM NR 1 OF IPC. OVEN OPS CHK OK NOISE LEVEL NORMAL PER LAXMM.Nov 15, 2011 · N596UA · Boeing 757222SDR UALA2011111506250Fan · failedLAV-GALLEY FAN FAULT ON UPPER ECAM. OK TO DEFER PER MEL 2123A MEL CW. SYSTEM TEST FAILED WITH EXTRACTION FAN 1HU AT FAULT, NO PART IN SEAL. PART IS: 565-0036. REPLACED EXTRACTION FAN, OPS CHECKS NORMAL.Nov 15, 2011 · N817UA · Airbus A319131SDR SIMA2011319011Inlet · dirtyON FLIGHT 3816 THE CREW REPORTED THE FLIGHT ATTENDANT NOTICED AN INTERMITTENT ELECTRICAL ODOR IN THE GALLEY. THE AIRCRAFT WAS REMOVED FROM SERVICE. FOUND EXCESSIVE DIRT/DEBRIS ON GALLEY AIR INLET, CLEANED AS REQUIRED. PERFORMED INSPECTION OF GALLEY AREA LIGHNov 15, 2011 · N512AE · Cndair CL6002C10SDR UALA2011111606288Drain Line · faultyPRESSURE SQUEAL COMING FROM FWD GALLEY CHILLER DRAIN HOSE, BEHIND ACCESS PANEL (REMOVED) JUST BELOW FWD GALLEY CHILLER. SQUEAL STARTS WHEN HULL IS PRESSURIZED TO 5.2 DIFFERENTIAL PRESSURE. REPLACED 2 EACH HOSES BY GALLEY CHILLER DRAIN. PRESSURIZED CABIN UP Nov 14, 2011 · N831UA · Airbus A319131SDR YENA20111114378Coffeemaker · faultyFLT 690 DCA-B0S, CREW REPORTED FAINT BURNING SMELL FROM FRONT GALLEY, POSSIBLE COFFEE HEAT PLATE. UNSURE OF SOURCE POTENTIAL, REPEAT WRITE UP. THE TECHNICIAN REMOVED AND REPLACED FWD GALLEY COFFEEMAKER. OPS CHECK, NO BURNING SMELL.Nov 14, 2011 · N318JB · Emb ERJ190100IGWSDR CALA2011111000727Oven · malfunctionedSMOKE IN GALLEY, RETURNED TO TLV. SMOKE CONDITIONAL INSP. MM 05-51-58-800-801CD PERFORMED, FOUND NO TIME DUE TO LATE ARRIVAL AND INBOUND WRITE UPS EXT 118600. OVEN NR 707 IS THE SOURCE. OVEN C/B PULLED OUT AND RED COLLAR INSTALLED. OVEN 707 INOP.Nov 10, 2011 · N76021 · Boeing 777224SDR UALA2011110906098Fan · faultyPRE-FLT CHECK FOUND STATUS MSG-LAV GALLEY FAN. REPLACED LAV-GALLEY VENT FAN AS PER MM AND OPS CHECK OK, NIL STATUS MSG DISPLAYED. PART REPLACED, P/N 4100149C, S/N 1350A. NON-POOL PART, RETURN IN SEVEN DAYS.Nov 9, 2011 · N181UA · Boeing 747422SDR SWAA117792Coffeemaker · faultyDURING FLIGHT, ELECTRICAL BURNINIG ODOR NOTED BY PILOTS AND FLIGHT ATTENDANTS, NO VISIBLE SMOKE. REMOVED AND REPLACED AFT NR 1 COFFEEMAKER PER MM.Nov 9, 2011 · N425LV · Boeing 7377H4SDR UALA2011110906119Plate · contaminatedBUSINESS CLASS GALLEY SMOKE SMELL COMING FROM VENTS. CHECKED ALL COMPONENTS IN AREA, NO DEFECTS NOTED, F/A REPORTED WHITE SMOKE RISE TO GALLEY VENT, SUSPECTED STEAM FROM WET HOT PLATE FROM A COFFEEMAKER. FOUND ANOTHER OFF HOT PLATE NEAR BY STILL WET.Nov 8, 2011 · N228UA · Boeing 777222SDR UALA2011110906116Motor · inoperativeCART LIFT INOPERATIVE. CART LIFT SYS INOP. NO TIME TO FIX. DF PER MEL. NOTIFIED OPB. DISCONNECTED CMD DOWN SW & REPLACED DN-HOLDING RELAY Y82K12, NO HELP. LIFT GOES DOWN UNCOMMANDED. REPLACED CART LIFT ACTUATOR MOTOR ASSY. ALSO REPLACED S05 LIMIT SWITCNov 7, 2011 · N118UA · Boeing 747422SDR CA111206013Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED, PN 400-1794-02, SN 11-01-47902, A/C TSN 1196, CSN 794.Nov 6, 2011 · Bombdr DHC8400SDR UALA2011110706049Fan · faultyLEFT GALLEY FAN LEFT EICAS. REPLACED LEFT LAV GALLEY VENT FAN AS REQUIRED. OPS CHECK NORMAL AT THIS TIME.Nov 6, 2011 · N773UA · Boeing 777222SDR DALA1162079004Coffeemaker · malfunctionedTHE COFFEEMAKER SKILLET, IN THE FIRST CLASS GALLEY, MELTED TO THE HOT PLATE AND CAUSED A BURNT ODOR IN THE CABIN. FLIGHT CREW HAD TO PULL AND SECURE THE CIRCUIT BREAKERS FOR THE COFFEEMAKER. FLIGHT CONTINUED TO SCHEDULED DESTINATION AND LANDED WITHOUT FURTHENov 5, 2011 · N904DE · Doug MD88SDR UALA2011110305964Control Unit · faultyNO POWER AFT GALLEY. FOUND CB S3 ON P11 PNL G4 B GALLEY PWR TRIPPED, NO RESET. REPLACED M227 L AFT GALLEY PWR ELCU MM. OPS CHECK OK. NEW ELCU BORROWED FROM AMERICAN AIRLINES P/N 3B39-1-C, SN 077C-6539. SHIPPING CONTAINER IN FWD PIT ON S/N SHOULD READ 078Nov 2, 2011 · N595UA · Boeing 757222SDR UALA2011110105913Cable · burnedNEW TECH CART CABLE P61 PINS BURNT AND PUSHED BACK. REPLACED CABLE PER MM, OP CHECKS OKAY.Nov 1, 2011 · N644UA · Boeing 767322SDR UALA2011103105877Oven · smokeGALLEY OVEN INOP AT 999. CREW COMMENTS: OVEN AT POSITION 106-R12 SMOKES WHEN USED. OPERATED BOTH OVENS IN FWD GALLEY, BOTH HEATED PROPERLY WITH NO SMOKE.Oct 30, 2011 · N425UA · Airbus A320232SDR UALA2011103105885Structure · crackedCABIN, GLY G1B, COUNTER TOP MOD BOX CUTOUTS FOR 109 &110, VERTICLE 'I-BEAM' DIVIDER CRACKED AT BOTH UPPER & LWR RADII. (FOUND DURING REMOVAL OF JAMMED MOD BOX). REMOVED UPPER & LOWER 'T' ANGLES FROM VERTICLE SHEAR WEB. CUT 2 PIECES OF 7075-T6, .050 HAVING 1Oct 28, 2011 · N512UA · Boeing 757222SDR CA111026013Oven · burned(CAN) FWD GALLEY NR 2 OVEN BURNING ODOR. MEL 25-20, CAT D RAISED BY KLM IN AMS. UPON INVESTIGATION, FOUND FAN SEIZED. REPLACED OVEN IAW AMM 25-34-00. OPS CHECKED SERVICEABLE.Oct 25, 2011 · Airbus A310300SDR CA111206012Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED, PN 400-1794-02, SN 11-03-48204. ACFT TSN 1157, CSN 765.Oct 24, 2011 · Bombdr DHC8400SDR CA111206011Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED, PN 400-1794-02, SN 11-03-48291, ACFT TSN 1132, CSN 746.Oct 23, 2011 · Bombdr DHC8400SDR CA111206010Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED. ACFT TSN 30, CSN 19.Oct 20, 2011 · Bombdr DHC8400SDR UALA2011102005681Coffeemaker · odorBURNED ELECTRICAL ODOR IN AFT GALLEY. PULLED CIRCUIT BREAKERS FOR BOTH COFFEEMAKERS AND WARMERS. ODOR DISSIPATED.Oct 20, 2011 · N821UA · Airbus A319131SDR UALA2011102005683Oven · odorFLIGHT ATTENDANT REPORTS A FAIRLY STRONG ACRID ODOR IN BUSINESS GALLEY. STRONGEST NEAR R2 DOOR. ACFT DIVERTED. CONFIRMED OVEN R32 TO BE THE CAUSE OF THE ODOR. WITH R32 OVEN RUNNING IT PRODUCES BURNING ODOR , COLLARED CIRCUIT BREAKER . REPLACED R32 OVEN PER Oct 20, 2011 · N779UA · Boeing 777222SDR CALA2011101800664Coffeemaker · malfunctionedFLT ATTD REPORTED LARGE SPARK (BLUE FLASH) AND HEARD A LOUD POP NOISE AT FWD C/M`S. SHUT BOTH C/MAKERS OFF. NOT SURE WHICH ONE COULD NOT DUPLICATE TROUBLES ABOVE. INSPECTED C/MAKER CAVITY AND ASSOCIATED WIRING. NO DEFECTS OR EVIDENCE NOTED. REMOVED AND REPOct 18, 2011 · N26210 · Boeing 737824SDR EIAA20111017239Oven · contaminatedDURING INSPECTION, OVEN FOUND WITH EXCESSIVE GREASE BUILD UP ON OVEN TRAYS & OVEN INNER LINING. CLEANED OVEN & PERFORMED OPS AS PER AMM 25-31-00Oct 17, 2011 · N482EV · Boeing 747212BSDR EIAA2011238Oven · malfunctionedOVEN WAS TURNED ON AND SMOKED. DEFERRED PER MEL 25-21-2. UNINSTALLED PLACARD. ACCOMPLISHED INSPECTION AS PER MM 05-51-50. PROCEDURES AS PER MM 21-00-01 NOT REQUIRED.Oct 17, 2011 · N482EV · Boeing 747212BSDR USAA2011101700013Oven · faultyMAN - BURNING SMELL COMING FROM OVEN NR 2, MID-GALLEY. OVEN WAS TURNED OFF AND F/A WAS INSTRUCTED TO PULL C/B. MAINTENANCE REMOVED AND REPLACED MID GALLEY OVEN IAW AMM 25-35-19-401, OPS CHECKS GOOD THIS CLEARS MEL # 25-22-03C.Oct 15, 2011 · N272AY · Airbus A330323SDR UALA2011101305556Oven · contaminatedFLIGHT ATTENDANT STATED ODOR BEGAN COMING FROM WARMING OVEN RIGHT SIDE. FOUND BURNED PLASTIC INSIDE WARMING OVEN. CLEANED OUT OVEN AND OPERATED. ODOR CLEARED.Oct 12, 2011 · N659UA · Boeing 767322SDR CA111111002Oven · burned(CAN) DURING CLIMB SMELL COMING FROM THE OVEN WAS OBSERVED INSIDE THE COCKPIT. IT CAME FROM THE OVEN IN THE GALLEY AND WAS GETTING STRONGER. THE FWD GALLEY FAN WAS UNSERVICEABLE AND IT SMELLS LIKE HOT METAL. THE OVEN WAS STOPPED AND THE CREW DECIDED TO RETUROct 10, 2011 · Cndair CL6002D24SDR UALA2011101105499Control Unit · malfunctionedNO AFT GALLEY POWER. REPLACED ELCU M227 PER MM, OPS CHECKS NORMAL.Oct 10, 2011 · N540UA · Boeing 757222SDR CA111207002Dcu · damaged(CAN) IMMEDIATELY AFTER ROTATE, AN AURAL `BLEED AIR DUCT` AND ASSOCIATED RED CAS MESSAGE ACTIVATED - SOON TO BE FOLLOWED BY VARYING AMOUNTS OF AMBER CAS MESSAGES. AUTOFLIGHT SYSTEMS, GEAR AND FLAP APPEARED TO OPERATE NORMALLY, SO THE SID WAS CONTINUED (MARUB Oct 9, 2011 · Cndair CL604SDR USAA2011101000001Oven · overheatedPHL- OVEN NR 1 4-2 BECAME VERY HOT. CABINETS ABOVE AND WALL BESIDE OVEN BECAME SO HOT THEY WERE TO HOT TO TOUCH. ODOR OF MELTING PLASTIC IN AREA MOST LIKELY FROM WALL COVERING PULLED CB DISCONTIUED USING. MAINTENANCE REMOVED AND REPLACED THE OVEN AND PERFOROct 7, 2011 · N285AY · Airbus A330243SDR UALA2011100605419Oven · malfunctionedGALLEY OVEN WON'T HEAT AT R12. CREW COMMENTS: UNEVEN HEATING ESPECIALLY ON THE BOTTOM. PULLED CB AND APPLIED STICKER. REMOVED LINED AND CLEANED OVEN, COILS AND FAN ARE WORKING PROPERLY AND FOUND OVEN TO HEAT PROPERLY.Oct 6, 2011 · N461UA · Airbus A320232SDR CA111005005Oven · odor(CAN) SMOKE EMANATING FROM GALLEY OVEN, CONSULTED MOC. BREAKER PULLED AND SMOKE DISSIPATED. FLIGHT CONTINUING TO DESTINATION.Oct 5, 2011 · Airbus A320211SDR YENA20111003357Coffeemaker · malfunctionedFLT 415 BOS-SAN, FLIGHT ATTENDANT OBSERVED ELECTRICAL BURNING SMELL FROM ONE COFEE POT IN REAR GALLEY. REMOVED AND REPLACED NR 1 AFT COFFEEMAKER AS REQUIRED.Oct 3, 2011 · N535JB · Airbus A320232SDR DALA1156646814Oven · fireSMALL FIRE IN AFT GALLEY NR 2. TWO PIZZA BOXES CAUGHT FIRE. BREAKERS PULLED, FIRE EXTINGUISHED. NO FIRE EXTINGUISHERS WERE REQUIRED.Oct 3, 2011 · N711ZX · Boeing 757231SDR DALA1156760686Coffeemaker · contaminatedNOXIOUS FUMES FROM AFT GALLEY WHILE AT FL370. FUMES DISSIPATED AFTER THE QRH WAS ACCOMPLISHED. FLIGHT DIVERTED TO FSD AND LANDED WITHOUT INCIDENT. FOUND PLASTIC ON BOTTOM OF COFFEE POT AND WARMING PLATE. CLEANED POT AND HOTPLATE. RAN ENGINES THROUGH BLEEDOct 3, 2011 · N686DA · Boeing 757232SDR USAA2011100500020Oven · contaminatedPASSING THROUGH 13,000 FT, CAPTAIN SMELLED A BURNING ODOR IN COCKPIT AS IF OVEN WAS ON WITH PLASTIC INSIDE. FOUND BURNED SUBSTANCE IN OVEN. REMOVED AND REPLACED OVEN IAW MM 25-35-19.Oct 1, 2011 · N741UW · Airbus A319112SDR AALA20110930ORD01Circuit Breaker · defectiveORD - INFLIGHT JFK-SFO. CREW REPORTED FAINT BURNING ODOR IN COCKPIT AND CABIN. EMERGENCY DECLARED FLIGHT DIVERTED ORD LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED LEFT SIDE 15 AMP CIRCUIT BREAKER FOR CHILLER IN AFT GALLEY. SYSTEM GROUNSep 30, 2011 · N324AA · Boeing 767223SDR R61A20110296Trim Panel · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND CORROSION ON AFT GALLEY FWD HALF MATING SURFACE. MAINTENANCE INSTALLED NEW TRIM ON AFT GALLEY FWD HALF MATING SURFACE IAW EMB 170 AMM 25-00-23. AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK. P/N REMOVED AND RESep 30, 2011 · N111HQ · Emb ERJ170200LRSDR USAA2011100300014Oven · defectiveFLIGHT ATTENDANT REPORTED A BURNING PLASTIC ODOR EMANATING FROM FORWARD GALLEY. TURNED BOTH OVEN SWITCHES AND BUN WARMERS TO OFF - ODOR STILL PRESENT AT TIMES. NO SMOKE OR OTHER INDICATIONS ASSOCIATED WITH SMELL. MAINTENANCE REMOVED AND REPLACED NR 1 OVEN ISep 28, 2011 · N602AW · Airbus A320232SDR UALA2011092805239Heater · damagedELECTRICAL ODOR ALONG THE LONG BUFFET. SHUT DOWN POWER TO CARTS AND ODOR DISSIPATED. INSTALLED NEW SET OF FOOD CARTS AND RAN ALL ELECTRICAL ITEMS IN AFT GALLEY FOR 1.5 HRS, NO ELECTRICAL ODOR NOTED. SUSPECT BAD FOOD CART HEAT ELEMENT. PIGTAIL HAVE EXPOSEDSep 27, 2011 · N116UA · Boeing 747422SDR CA111206009Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED, PN 400-1794-02, SN 11-03-48291, ACFT TSN 210, CSN 133.Sep 24, 2011 · Bombdr DHC8400SDR CALA2011092600621Oven · contaminatedOVERWEIGHT LANDING DUE TO HEAVY SMOKE IN AFT GALLEY. LANDING WEIGHT 4207K. PERFORMED INSPECTION PER AMM 05-51-31 NO FOUND DAMAGE. ACC PHASE 1 EXAMINATION ACC TASK 05-51-35.Sep 23, 2011 · N76062 · Boeing 767424ER
Back to JASC 2530