SDR DXTA2012041604951Oven · smokeDURING TAXI FOR TAKEOFF SMOKE STARTED COMING OUT OF CONVECTION OVEN. ACFT WAS STOPPED IN HOLDING AREA, AND OVEN WAS TURNED OFF AND SMOKE WAS EVACUATED FROM CABIN BY OPENING BAGGAGE DOOR.SDR UALA2012041302247Structure · unsecureLOOSE TRIM IN FORWARD GALLEY CAUSING TRIPPING. TRIMMED LOOSE MATERIAL & APPLIED TAPE TO PREVENT FURTHER DAMAGE OR TRIPPING.SDR AALA20120410003Coffeemaker · damagedFLIGHT ATTENDANT REPORTED HEARING LOUD POP FROM AREA AROUND COFFEEMAKER CM3. NOTED SLIGHT ELECTRICAL ODOR BRIEFLY. NOT USED FOR REST OF FLIGHT. FLIGHT LANDED WITHOUT INCIDENT. FOUND CIRCUIT BREAKER FOR COFFEEMAKER NR 3 TRIPPED AND DAMAGE TO HEATER ELEMENT SDR YENA20120407471Coffeemaker · smokeFLT 681, AFT INBOARD COFFEEMAKER SMOKING. INSPECTION COMPLETED PER FIM 21-00-00-810-801A.SDR USAA2012040200028Chiller · faultyFLIGHT ATTENDANTS REPORTED AN ELECTRICAL ODOR EN ROUTE. TURNED OFF CHILLERS AS A PRECAUTION AND ODOR DISSIPATED TEMPORARILY, RETURNED SHORTLY BEFORE LANDING. REMOVED AND REPLACED AFT CHILLER IAW MM 25-34-51.SDR UALA2012032601888Hose · brokenFWD GALLEY CHILLER HAS A BROKEN HOSE IN DRAIN LINE. INSTALLED FWD GALLEY CHILLER AS PER MM, OPS CHECKED GOOD.SDR UALA2012032201824Oven · dirtyBURNING ODOR 2R, NO SMOKE. FOUND PLASTIC BUGS BURNT IN WARMING OVEN W31 CAUSED BURNING ODOR IN THE DOOR 2 AREA. REMOVED BUGS FROM OVEN. NEED TO CLEAN DEBRIS IN THE OVEN OR REPLACE ITSELF. CONSULTED WITH TOMC AND DEACTIVATED W31 OVEN PER MEL PROC. CREW ALSSDR UALA2012032301868Oven · dirtyBURNING ODOR 2R. NO SMOKE. ITEM ROLLED FORWARD. FOUND PLASTIC BUGS BURNT IN WARMING OVEN W31 CAUSED BURNING ODOR IN THE DOOR 2 AREA. REMOVED BUGS FROM OVEN. NEED TO CLEAN DEBRIS IN THE OVEN OR REPLACE ITSELF. CONSULTED WITH TOMC AND DE-ACTIVATED W31 OVENSDR YENA20120321459Coffeemaker · defectiveFLT 482 LAX-BOS, CREW REPORTED COFEE POT NR 2 IN G5 MAY BE CAUSING SMOKE. CREW SECURED IT OFF. REMOVED AND REPLACED AFT GALLEY COFFEE POT (507) IAW AMM 25-35-01. OPS CHECK GOOD.SDR QXEA2012032100235Coffeemaker · odorF/A REPORTS BURNING ODOR IN AFT GALLEY BY COFFEE WARMERS. TURNED COFFEEMAKER OFF AND ODOR DISSAPATED. NO APPARENT SMOKE. ODOR APPEARED TO COME FROM THE COILS ON THE BACK OF THE COFFEE WARMER. DEFERRED. ACFT RETURNED TO SERVICE.SDR CALA2012031900195Oven · malfunctionedIN CRUISE LEAD F/A CALLED AND STATED THAT THERE WAS A STRONG SMELL IN AFT GALLEY THAT SMELLED LIKE ELEC WIRING OR PLASTIC BURNING. TURNED OFF OVEN AND COFFEEMAKER. RAN QRH. NO SMOKE ONLY SMELL. SMOKE DID NOT DISSIPATE. DECLARED EMERGENCY AND DIVERT TO ATLSDR J7SA20120316001Thermostat · failedRED GALLEY OVERHEAT CAS POSTED. REPLACED HOT CUP & THERMOSTAT.SDR USAA2012031500008Coffeemaker · defectiveFLIGHT ATTENDANT REPORTED AN ODOR IN THE REAR GALLEY THAT SMELLED LIKE TOAST WHICH CAUSED HER TO FEEL ILL. MAINTENANCE FOUND THE AFT LEFT COFFEEMAKER HEAT ELEMENT DEFECTIVE. REMOVED AND REPLACED COFFEEMAKER.SDR NOCA201204030012Oven · odorAFT GALLEY OVEN 5 HAS A BURNING ODOR AND STOPPED HEATING. OPENED CI 25-416 NEF 25-30-H AND PULLED AND COLLARED OVEN CIRCUIT BREAKER REMOVED AND REPLACED NR 5 OVEN REF CMM 25-36-22, OPS NORMAL.SDR NOCA20120312012Oven · defectiveAFT GALLEY OVEN NR 5 HAS A BURNING SMELL AND STOPPED HEATING. OPENED CI 25-416 NEF 25-30-H AND PULLED AND COLLARED OVEN CB (ITEM REMAINS OPEN).SDR NSVA20120307467Coffeemaker · malfunctionedCREW DID AN EMERGENCY EVACUATION DUE TO F/A REPORTING SMOKE COMING FROM THE COFFEE POT AREA AFTER HEARING POPPING NOISE. THE CREW DECLARED AN EMERGENCY AND EVACUATED 48 PASSENGERS. EVERYONE GOT OUT SAFELY UTILIZING THE MAIN CABIN DOOR ONLY. EMERGENCY EQUIPMSDR CALA2012030200141Oven · contaminatedUSED HALON FIRE EXT ON INTERIOR OF OVEN NR 1 POSITION 423 AFT GALLEY. INSPECTED OVEN. FOUND PAPER LABEL STUCK TO OVEN INSERT IS WHAT BURNED. NO DAMAGE TO OVEN, HOWEVER, OVEN UNUSABLE DUE TO HALON CONTAMINATION. PLACED OVEN #423 ON PLACARD. PULLED AND COLSDR UALA2012022801240Oven · dirtySMOKE CAME OUT OF OVEN 31. OVEN OFF NOW NO SMOKE OR FIRE. DEACTIVATED OVEN R31 AT MID GALLEY. CIRCUIT BREAKER PULLED AND COLLARED. CLEANED OVEN, OPS CHECK NORMAL.SDR UALA2012022701186Chiller · faultyLEFT AFT CHILLER BLOWING WARM AIR. REPLACED CHILLER PER AMM, OPS CHECK NORMAL. UNIT OFF MR25349-1500 UNIT ON MR25349-1472.SDR AALA20120226008Oven · dirtyLHR - CREW REPORTED ELECTRICAL ODOR IN MID CABIN GALLEY. GALLEY EMERGENCY POWER CONTROL SWITCH TURNED OFF ODOR THEN DISSIPATED. FLIGHT LANDED LHR WITHOUT INCIDENT. FOUND ON INVESTIGATION OVENS 4A/B PRODUCING ODORS. REPLACED OVEN 4A/B. SYSTEM GROUND CHECK NSDR CALA2012020300070Oven · dirtyPREVIOUS CREW SMELLED SMOKE IN FWD GALLEY AND PULLED ALL GALLEY C/B'S, PERFORMED AMM TASK 05-51-26-800-801C1 FWD GALLEY OVEN 204 HAD SPILLAGE/DEBRIS. REPLACED OVEN, CHECKS GOOD. FORMS/REPORTS FAXED TO MX CONTROL ROTABLE PARTS CHANGE WAS INDICATED - TT # 1526SDR UALA2012020300665Oven · overheatedF/A SMELLS BURNING ELEC SMELL IN FWD GALLEY OPS ALL GALLEY USERS. OPENED ALL FIRST CLASS GALLEY CEILING PANELS AND INSPECTED AREA ABOVE, NO SMELLS OR HOT UNITS FOUND IN ENTIRE AREA. RMV'D CONTENTS OF WARMING OVENS, NO ODOR DETECTED. FOUND OVEN R11 OVERHEATISDR UALA2012020200639Coffeemaker · faultyM41 AND M42 COFFEEMAKER SMELL LIKE BURNING PLASTIC WHEN ON. REPLACED BOTH AFT GALLEY COFFEEMAKERS M41 & M42, OPS CHECKED GOOD.SDR USAA2012013000016Oven · faultyUPON PICKING UP AIRCRAFT IN DTW, THERE WAS A STRONG EXHAUST TYPE SMELL THROUGHOUT ENTIRE AIRCRAFT. THIS WAS WITH NO EXTERNAL AIR AND APU WAS OFF. ODOR LESSENED DURING OPERATIONAL CHECK WITH PACKS ON BUT DID NOT GO AWAY. CREW MEMBERS REPORTED HEADACHES AND NSDR R61A20120055Door · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND FWD HALF AFT GALLEY ENTIRE METAL STRIPS IN BETWEEN MID SECTION, EVIDENCE OF CORROSION FOUND. MX REMOVED AND REPLACED AFT GALLEY METAL TRIM PIECES IAW EMB 175 AMM 25-00-23, REPLACED SPRINGS FOR TRASH DOOR THAT WAS DAMAGEDSDR R61A20120054Trim Panel · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND AFT HALF AFT GALLEY ENTIRE FRONT STRIPS SHOW EVIDENCE OF CORROSION. P/N 170-59522-001 MX REMOVED AND REPLACED AFT GALLEY FRONT STRIPS IAW EMB 175 25-00-23. CLEANED AREA IAW 51-12-00. A/C REMAINS IN CMH FOR HEAVY CHECK SDR R61A20120053Trim Panel · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND AFT HALF AFT GALLEY ENTIRE METAL STRIPS IN BETWEEN MID SECTION SHOW EVIDENCE OF CORROSION. MX REMOVED AND REPLACED METAL STRIP ON AFT GALLEY IAW EMB 175 AMM 25-00-23, AND REMOVED CORROSION IAW EMB 175 SRM 51-12-01. P/N SDR CA120130003Heater · malfunctioned(CAN) THE FLIGHT ATTENDANT NOTICED THAT THE GALLEY HEATER SWITCH OVERHEAT CONDITION LIGHT WAS ILLUMINATED. THE SWITCH WAS DESELECTED AND THE SYSTEM DEFERRED IN ACCORDANCE WITH THE MEL. DURING TROUBLESHOOTING, MAINTENANCE FOUND THE HEATER ASSEMBLY INTERNAL ELEMSDR UALA2012011600325Fastener · wrong partCOMPARTMENT 107 IN FWD GALLEY HAS WRONG SIZE QUARTER TURN. FOUND CORRECT QTR TURN INSTALLED.SDR UALA2012011300281Chiller · failedAFT CHILLER INOPERATIVE, AFT CHILLERS DO NOT WORK, INOPERATIVE AND WILL NOT COOL. FOUND BOTH CHILLERS C51 AND C52 BLOWING UNCOOLED AIR. REPLACED BOTH AFT CHILLERS.SDR UALA2012011000221Oven · overheatedGALLEY OVEN BECAME VERY VERY HOT AND SHUTDOWN. CIRCUIT BREAKER DID NOT TRIP. REPLACED OVEN.SDR CALA2012010900017Coffeemaker · defectiveLOUD POP AND FIRE REPORTED IN FORWARD GALLEY. PERFORMED INSPECTION REF AMM 05-51-95 FWD GALLEY AREA. FOUND COFFEEMAKER POS NR 1 WATER HEATER CERAMIC ELEMENT POPPED AND BURNT. REMOVED AND REPLACED COFFEEMAKER POS 1 ALONG WITH POSITION 2 AND FWD GALLEY OVEN ASDR USAA2012010600002Oven · defectiveFIRST CLASS OVEN PRODUCED SMOKEY SMELL AND POPPED CIRCUIT BREAKER. MAINTENANCE REMOVED AND REPLACED FORWARD OVEN IAW AIRBUS MAINTENANCE MANUAL 25-35-19.SDR FDEA201201030004Tie Rod · shortWHILE CARRYING OUT EO F-2530-7-5000, PT9, STEP 3, GALLEY 1A UPPER CENTER ATTACHING ROD WILL NOT FIT (TOO SHORT). EA F-2530-153492 COMPLIED WITH. THIS ALTERATION IS CLASSIFIED AS MINOR IAW GMM.SDR CA120103010Controller · failed(CAN) AFTER TAKEOFF APPROXIMATELY 60 MILES EAST THE FLIGHT CREW WAS ADVISED OF SMOKE AND A BURNING ELECTRICAL SMELL IN THE AFT GALLEY. THE CREW DECLARED AN, EMERGENCY EMERGENCY, AND RETURNED TO LAND OVERWEIGHT APPROXIMATELY 13000K. THE ACFT WAS MET BY EMERGENSDR DJFA20111227049Microwave Oven · inoperativeDURING FLIGHT, PASSENGERS REPORTED BURNING ODOR IN THE CABIN. NO SMOKE WAS NOTED IN THE ACFT AND ACFT LANDED SAFELY. MX DETERMINED THE ODOR TO BE COMING FROM THE MICROWAVE OVEN. THE MICROWAVE OVEN WAS REMOVED.SDR UALA2011122207059Lamp · inoperativeAFT GALLEY CHILLER INOPERATIVE. RELAMPED C52 POWER ON INDICATION LIGHT, C51 & C52 AIR FLOW CHECKED NORMAL.SDR DXTA2011122104830Microwave Oven · odorELECTRICAL BURNING ODOR FROM MICROWAVE OCCURED AT FLIGHT LEVEL 450. REMOVED & INSTALLED MICROWAVE IAW CMP 253010. OPS CHECKED NORMAL.SDR F3LA2011121500694Coffeemaker · shortedELECTRICAL ODOR, ACRID ODOR REPORTED IN AFT GALLEY AREA ABOVE COFFEE POT - WARM TO THE TOUCH. TOTAL CYCLES 114925. FOUND AFT INBD NR 2 COFFEEMAKER INOPERABLE, CB'S POPPED. PLACED COFFEEMAKER ON NEF 25-99-30AD.SDR UALA2011121406861Seal · missingSAME SQUEAL NOISE IN FWD CABIN AT CRUISE. PRESSURIZED CABIN WITH CEILING PANELS DOWN, NO LEAKS NOTED. TURNED ON CHILLER AND STARTED CHECKING CART VALVES AND FOUND ONE CART VALVE ACCORDION SEAL MISSING FROM CHILLER INLET TO CARD MAKING NORMAL HIGH PITCH SOUNDSDR WRLA20111212527Oven · malfunctionedGALLEY BUS 3 OFF ALERT CAME ON WHEN F/A STARTED OVENS IN AFT GALLEY. SUSPECT OVENS 1 AND 2. F/A HEARD A POP SOUND AND SAW SPARKS FROM OVEN. SHUT OVENS 1 AND 2 OFF AND RESET GALLEY BUS 3.SDR USAA2011121400021Coffeemaker · dirtyFLIGHT ATTENDANT SMELLED ELECTRICAL BURNING SMELL IN FORWARD GALLEY ON DESCENT INTO RDU. TURNED OFF ALL ITEMS IN FORWARD GALLEY AND SMELL DISSIPATED. FOUND FORWARD COFFEEMAKER TO HAVE BURNT COFFEE ON HEATER PAD. CLEANED COFFEEMAKER HEATING PAD. RAN ALL GALSDR UALA2011120906775Light · inoperativeAFT F/A DETECTED AN ELECTRICAL BURNING ODOR. FOUND HOT PLATE ON, LIGHT WAS INOPERATIVE. SHUTOFF PLATE AND PULLED CIRCUIT BREAKER, ODOR DISSIPATED. REPLACED COFFEEMAKER AND RESET CIRCUIT BREAKER, OPS CHECKED OKAY.SDR UIEA2011120600702Pdu · failedDURING PROCESS OF UPLOADING ACFT, MDC PDU AT 18L FAILED (SMOKE) PDU REMOVED AND INSTALLED JUMPER AND BLACKING PLATE.SDR USAA2011120500015Coffeemaker · odorON DESCENT INTO MCO, A VERY STRONG ODOR WAS REPORTED IN CABIN BY FLIGHT ATTENDANT. OCCURRED DURING LAST FIVE MINUTES OF FLIGHT. MAINTENANCE ACCOMPLISHED 737 T/S CABIN ODOR JOB CARD 03L00021001. INSPECTED AND OPS CHECKED ENGINE, APU AND PACKS. REPLACED HEPA SDR USAA2011120500014Service Cart · odorZRH FLT 710 EN-ROUTE PHL TO ZRH. OVEN AT AFT A/C RIGHT GALLEY SMELLS LIKE BURNING WIRES WHEN TURNED ON. SINGLE SERVICE CART NO. A301 REPLACED BY CATERING. NO. A301 ELECTRIC INSTALLATION CHECKED. NO ANOMALIES NOTED. HEATING CHECKED ON HEATING TROLLEY. ASDR DALA1166719203Oven · overheatedFLIGHT CREW REPORTED THE FORWARD GALLEY OVEN GOT HOT AND HAD A STRONG ODOR. CREW PULLED CIRCUIT BREAKER ABOVE OVEN. MAINTENANCE REMOVED AND REPLACED FORWARD GALLEY OVEN PER AMM 25-35. OPERATION CHECKS GOOD. REMOVED (LP C12061126).SDR ANCF2011112900096Oven · defectiveAFT GALLEY OVEN 511 PRODUCE BLACK SMOKE WITH SMELLS LIKE BURNT ELECTRICAL INSULATION.SDR Z2KR2011FA0000761Coffeemaker · shortedREPAIR STATION HAS RECEIVED A LIMITED NUMBER OF COMPLAINTS OF 400-1794-02 BREWERS CAUSING ELECTRICAL SHOCK TO F/A. IN-HOUSE GROUND TESTING OF THE POWERED BREWER SITTING ON A METAL SURFACE, WITH A STEADY STREAM OF WATER DIRECTLY ONTO THE POWER SWITCH INDICATEDSDR USAA2011120100007Oven · dirtyCHEMICAL ODOR COMING FROM FORWARD NR 2 OVEN. FOUND SMELL COMING FROM SPILLED LIQUID IN FORWARD GALLEY OVEN. CATERING REMOVED AND REPLACED OVEN RACKS. PROBLEM CLEARED.
Back to JASC 2530