SDR AALA20110806NRT01Oven · malfunctionedFIRST CLASS GALLEY NUMBER 1 OVEN HAS BURNING ODOR WHEN OPERATING. DEFERRED NUMBER 1 OVEN IN FIRST CLASS GALLEY INOPERATIVE PER NEF25-33A. NUMBER 1 OVEN CIRCUIT BREAKER PULLED AND COLLARED. REPLACED FIRST CLASS GALLEY OVEN AT LAX ON 08/07/2011. SYSTEM GROUNAug 6, 2011 · N755AN · Boeing 777223SDR USAA2011080500018Oven · defectivePHX - FLT 1197 EN ROUTE PHL TO PHX. OVEN AT G1A DEFECTIVE, STRONG ELECTRICAL SMELL WHEN ATTEMPTING USE. MAINTENANCE ACTION WAS DEFERRED BY PLACING THE G1A GALLEY NR 1 OVEN ON MEL. MAINTENANCE REMOVED AND REPLACED G1A OVEN. OPS CHECK GOOD.Aug 4, 2011 · N202UW · Boeing 7572B7SDR UALA2011080304031Oven · malfunctionedGALLEY OVEN WON'T HEAT AT R13. CLEANED ALUMINUM WRAP IN BAFFLE PLATE. CHECKED TEMP 350 DEG PER MM, OPS CHECKED GOOD.Aug 3, 2011 · N676UA · Boeing 767322SDR NOCA07111Insert · fireITEM FROM CABIN LOGBOOK # 22134 - AFT GALLEY OVEN NR 4 HAD A MINOR FIRE DUE TO OVEN INSERT TO THIN. REMOVED OVEN INSERT, SDR REMAINS OPEN.Aug 3, 2011 · N754NA · Boeing 75728ASDR NOCA0711Insert · fireAFT GALLEY OVEN NR 4 HAD A MINOR FIRE DUE TO OVEN INSERT TO THIN THE OVEN INSERTS ARE DIFFERENT FROM NAA INSERTS. REMOVED OVEN INSERT AND PLACED PROPER INSERT IN OVEN.Aug 3, 2011 · N754NA · Boeing 75728ASDR UALA2011080304021Unknown · overflowCM, M62, AFT GALLEY, CM OVERFLOWS. REPLACED CM.Aug 2, 2011 · N769UA · Boeing 777222SDR XGC2011F00000Converter · smokeSMOKE OF UNKNOWN ORIGIN COMING FROM GALLEY INFLIGHT. MX , SMOKE DAMAGED 60 HZ CONVERTER LOCATED BEHIND GALLEY TRASH BIN PANEL. PLUG REMOVED ON AFFECTED COMPONENT. (1) FLIGHT TO HOME BASE FOR FURTHER C/A ITEM ADDRESSED ACCORDING TO ACFT MEL PROCEDURES ACCOCIJul 31, 2011 · N200LC · Gulstm GIVSDR SWIA201127050Coffeemaker · smokeSMOKE COMING FROM COFFEEMAKERS. (FLT 6516) REPLACED BOTH HOT JUGS.Jul 30, 2011 · N221SW · Emb EMB120ERSDR USAA2011080200025Service Cart · overheatedCLT - HEATED CART AT AFT 2 GALLEY CART DEFECTIVE - ELECTRIC BURNING SMELL. PLUG TOO HOT TO TOUCH. ELECTED TO PULL BREAKER AND SHUT OFF AT SWITCH. MAINTENANCE COULD NOT DUPLICATE DEFECTIVE CART. NOTIFIED CATERING TO CHANGE OUT AFT 2 GALLEY CARTS. A/C OK FOJul 30, 2011 · N253AY · Boeing 7672B7ERSDR CA110728004Oven · smoke(CAN) SMOKE IN THE GALLEY, DUMPING FUEL, PROBABLE OVERWEIGHT LANDING. STRONG ELECTRICAL SMELL COMING FROM OVEN 7108 FWD GALLEY. CREW OBSERVED SMOKE COMING FROM VENT AREA ABOVE OVEN COMP. SMOKE WAS ISOLATED TO OVEN COMP WITH BURNED/ELEC ODOR FROM OVEN. NOJul 28, 2011 · Boeing 777233LRSDR DALA1145500670Coffeemaker · dirtyDURING FLIGHT, A FIGHT ATTENDANT REPORTED A HOT ELECTRONICS / WIRING SMELL IN THE MID GALLEY, DOOR 2 AREA. IN FLIGHT ENTERTAINMENT AND GALLEY CIRCUIT BREAKERS WERE PULLED. MAINTENANCE DETERMINED THE SMELL ORIGINATED FROM THE COFFEEMAKERS. COFFEEMAKERS AND GJul 28, 2011 · N670DN · Boeing 757232SDR USAA2011072800001Coffeemaker · odorAFT FLIGHT ATTENDANT REPORTED A HOT ODOR IN RIGHT REAR LAVATORY. CHECKED COFFEE POTS OFF AND ALL COMPARTMENTS. ODOR GONE AFTER 10 MINUTES. MAINTENANCE INSPECTED AFT GALLEY AREA AND NOTED AFT RIGHT COFFEEMAKER HAD ODOR. REMOVED AND REPLACED AFT RIGHT COFFEEJul 27, 2011 · N445US · Boeing 7374B7SDR USAA2011072700009Cart · sparksAFT OVEN A301 SPARKING. REPLACED HEAT CART BY CATERINGJul 25, 2011 · N249AU · Boeing 767201SDR DALA1144376305Controller · malfunctionedDURING FLIGHT, OVEN NR 2 IN GALLEY NR 1 EMITTED SMOKE UNTIL THE CIRCUIT BREAKER WAS PULLED. ELECTRIC SMELL WAS NOTED AS WELL. MAINTENANCE CHECKED THE OVEN CONTROLLERS AND OVENS AND REPLACED THE NR 2 OVEN CONTROLLER. OPERATIONAL CHECKS WERE GOOD.Jul 22, 2011 · N665US · Boeing 747451SDR UALA2011072103710Oven · dirtyELEC BURNING SMELL DESCENT INTO ORD WENT AWAY WITH GALLEY POWER OFF. FOUND OVEN R11 DIRTY. UNABLE TO REMOVE OVEN INSERT TO CLEAN. REPLACED OVEN R11. RAN ENGINES, OPERATED ALL GALLEY EQUIPMENT & LIGHTS INSPECTED GALLEY. NO ODORS OR DEFECTS PRESENT IN GALLEY Jul 20, 2011 · N437UA · Airbus A320232SDR USAA2011072200004Chiller · defectiveFLIGHT ATTENDANT REPORTED BURNING SMELL AND HOT SIDEWALL IN FORWARD GALLEY. TURNED OFF POWER TO FORWARD GALLEY AND SIDEWALL COOLED OFF. MAINTENANCE FOUND FRONT CHILLER BLOWING HOT AIR. REMOVED AND REPLACED CHILLER IAW AIRBUS MAINTENANCE MANUAL 25-34-00.Jul 20, 2011 · N108UW · Airbus A320214SDR YENA20110718301Coffeemaker · failedFLT 462 RSW-BOS, FWD GALLEY RT COFFEE POT HAS A BURNING ODOR AFTER POWER WAS TURNED OFF ODOR DISAPPEARED. REMOVED AND REPLACED COFFEE MAKER NO DEFECTS OR IRREGULAR SMELLS NOTED. A/C OK FOR SERVICE PER MM 25-37-03.Jul 18, 2011 · N193JB · Emb ERJ190100IGWSDR UALA2011071903665Sink · crackedAFT GALLEY SINK CORNER FOUND CRACKED. MASSIVE AMOUNT OF WATER LEAKING FROM LEFT SIDE OF AFT GALLEY ON DESCENT. WATER 8FT DOWN AISLE. FOUND CRACK IN AFT GALLEY SINK CORNER. CRACK IS IN AFT OUTBD CORNER WHEN LOOKING AFT. NEEDS TO BE WELDED OR REPLACED. -INF-Jul 17, 2011 · N524UA · Boeing 757222SDR USAA2011071500012Chiller · defectiveSTRONG DIRTY SOCK TYPE FUMES IN FIRST CLASS CABIN AREA IN FLIGHT. MAINTENANCE FOUND FORWARD GALLEY CHILLER DEFECTIVE (NOISY AND VIBRATING). REPLACED FORWARD GALLEY CHILLER.Jul 13, 2011 · N190UW · Airbus A321211SDR CA110714004Coffeemaker · shortedDURING CLIMB OUT, F/A RECEIVED A MILD ELECTRICAL SHOCK FROM COFFEE MAKER. NO INJURY SUSTAINED. THE F/A WAS WIPING OUT THE TRAY WHICH HOLDS THE COFFEE KETTLE WITH A WET CLOTH AND ACCIDENTLY TOUCHED THE ON/OFF SWITCH WHERE THE ELECTRIC SHOCK TOOK PLACE. COFFEEJul 11, 2011 · Dhav DHC8*SDR UALA2011071203486Chiller · faultyAFT GALLEY CHILLER RED FAULT LIGHT ON. DEACTIVATE CHILLER PER MEL. REMOVED AND REPLACED CHILLER ASSY.Jul 11, 2011 · N557UA · Boeing 757222SDR UALA2011070503330Oven · malfunctionedOVEN R-32 STARTED SMOKING. F/A T-SHUT OVEN DOWN. SMOKE STOPPED. CLEANED OVEN RAN 30 MIN, NO SMOKING AT THIS TIME TEMP HOLDS 350 DEGREES.Jul 5, 2011 · N796UA · Boeing 777222SDR UALA2011070103229Chiller · leakingCREW REPORTS WATER LEAK IN THE FORWARD GALLEY. SAMC TEXT: WATER LEAKING FROM THE C11 CHILLER IN THE FWD GALLEY. INOP'D THE C11 CHILLER. NEEDS CHILLER PCN 565-9026. CHILLER ACCESS PANEL HAS 3 STRIPPED FASTENERS, WILL REQUIRE MORE TIME AND NEW FASTENERS. NJun 29, 2011 · N460UA · Airbus A320232SDR USAA2011062800032Coffeemaker · malfunctionedDFW-PHX - ELECTRICAL SMELL - NR 1 FORWARD COFFEEMAKER HAS ELECTRICAL SMELL, ALL LIGHTS ON. REMOVED AND REPLACED FORWARD NR 1 COFFEEMAKER. PERFORMED OPERATIONAL CHECK PER AMM 25-35-15. OPERATIONAL CHECK GOOD.Jun 26, 2011 · N820AW · Airbus A319132SDR USAA2011062700004Oven · faultyFLT 1181 - CLT - ODOR - CREW REPORTED THE FORWARD OVEN PRODUCES A NOTICEABLE ELECTRIC SMELL. MAINTENANCE REMOVED AND REPLACED THE FORWARD GALLEY OVEN IAWB737 MM 25-00. OPS CHECK SATISFACTORY.Jun 25, 2011 · N453UW · Boeing 7374B7SDR CALA2011062800451Light · brokenGALLEY G2 1EA RT EMERGENCY LIGHT FOUND CRACKED. GALLEY G2 1EA RT EMERGENCY LIGHT REPLACED AND TESTED NORMAL AS PER AMM 33-51-00.Jun 24, 2011 · N67157 · Boeing 767224SDR HALA2011062300279Coffeemaker · burnedABOVE 10,000 FT. ALL EXIT SIGNS EXCEPT FOR THE 2L EXIT SIGN WENT OUT. THE F/A'S NOTICED A BURNING SMELL FROM THE 2L GALLEY AREA AND THE AFT GALLEY AREA. PERFORMED OPERATIONAL TEST OF THE OVERHEAD EXIT SIGNS CONTROL UNIT IAW AMM 33-51-00-710-804A. TEST GOODJun 23, 2011 · N380HA · Airbus A330243SDR USAA2011062300018Control Unit · smokeCOFFEEMAKER DEFECTIVE CIRCUIT BREAKER POPPED ACCOMPANIED WITH STRONG ODOR. REPLACED ELECTRICAL CONTROL UNIT FOR RT AFT GALLEY, COFFEEMAKER RAIL AND COFFEEMAKER AT POSITION A308. REPAIRED 3 PHASE INPUT TO RT AFT GALLEY. COFFEEMAKER OPS & LEAK CHECKED OK.Jun 21, 2011 · N249AU · Boeing 767201SDR UALA2011062003012Lamp · inoperativeGALLEY HOT PLATE LIGHT INOPERATIVE AT DOOR-1R FWD-CABIN FWD GALLEY. RELAMPED, OPS CHECKED OKAY.Jun 20, 2011 · N596UA · Boeing 757222SDR DALA1139970665Tray · meltedFLIGHT DIVERTED TO BWI DUE TO A HOT PLASTIC SMELL IN THE CABIN. THE UTILITY BUS WAS TURNED OFF AND THE SMELL DISSIPATED. NO SMELL FOR THE REMAINING 40 MINUTES. MAINTENANCE FOUND A MELTED SERVING TRAY IN NR 1 MID GALLEY OVEN. REMOVED TRAY RAN PACKS, VIDEOS,Jun 17, 2011 · N665DN · Boeing 757232SDR YENA20110617273Coffeemaker · odorFLT 485 BOS-LAX, SMELL OF SMOKE IN FWD GALLEY COMING FROM COFFEE POT 2 AFTER BEING TURNED ON FOR 3 MINUTES. NO VISIBLE SMOKE OF FLAME NOTED. COFFEE POT CB 2 PULLED IMMEDIATELY. TECHNICIAN RESET NR 2 C/M CB, VERIFIED SMELL OF SMOKE ONCE IT WAS TURNED ON. REJun 17, 2011 · N708JB · Airbus A320232SDR USAA20110620SB103Coffeemaker · faultyORF - WHILE EN ROUTE CLT TO PVD, DURING CRUISE, FLIGHT ATTENDANT REPORTED A STRONG ELECTRICAL BURNING SMELL IN THE AFT GALLEY. AN EMERGENCY WAS DECLARED AND THE FLIGHT DIVERTED AND LANDED WITHOUT FURTHER INCIDENT AT ORF. FLIGHT TAXIED TO THE GATE WHERE PASSEJun 16, 2011 · N532AU · Boeing 7373B7SDR AALA20110616LHR01Coffeemaker · contaminatedELECTRICAL SMELL DETECTED WHEN OPERATING AFT GALLEY COFFEEMAKERS. ODOR DISAPPEARED WHEN COFFEEMAKERS TURNED OFF. REMOVED AFT GALLEY COFFEEMAKERS AND INSPECTED WIRING NO FAULTS FOUND. REPLACED NUMBER 1 COFFEEMAKER DUE TO PLASTIC MELTED THAT HAD MELTED ON HOTJun 16, 2011 · N179AA · Boeing 757223SDR UALA2011061402937Control Unit · malfunctionedNO PWR IN FWD GALLEY OR RIGHT SIDE OF AFT GALLEY. SAMC TEXT: CREW CYCLED UTILITY BUSES AND RESTORED POWER TO THE GALLEYS. THIS IS CHRONIC. SEE HISTORY. REF LM8852. REPLACED FWD GALLEY ELCU AND AFT RH GALLEY ELCU REF MM AND PERFORMED FUNCTIONAL TEST, TEST Jun 14, 2011 · N669UA · Boeing 767322SDR UALA2011061402927Chiller · faultyCREW REPORTS FLIGHT ATTENDANT IN FORWARD GALLEY SMELLED AN ACRID ODOR. CREW TURNED OFF THE LIGHTS FOR THE FORWARD GALLEY AND THE SMELL DISSIPATED. DEBRIEFED CABIN CREW UPON ARRIVAL TURNED OFF GALLEY LIGHTS AND CHILLER SMELL DISSIPATED. FOUND WATER IN CHILLEJun 13, 2011 · N586UA · Boeing 757222SDR DALA1139761706Oven · dirtyWHEN FLIGHT CREW TURNED ON FIRST CLASS OVEN, GOT VERY STRONG BURNING SMELL WITHIN ONE MINUTE. CREW TURNED EVERYTHING OFF AND THE SMELL DISSIPATED. MAINTENANCE INSPECTED OVEN NR 2 WITH BENT DOOR LOCK HINGE AND PRESENCE OF BURNT PEANUTS THAT CAUSED ODOR DESCRJun 12, 2011 · N176DZ · Boeing 767332SDR MASA2011061302993Coffeemaker · smokeSMOKE FROM AREA OF COFFEEMAKER- RT COFFEEMAKER SMELLS OF SMOKE, PULLED AND COLLARD CIRCUIT BREAKER. R & R COFFEEMAKERJun 11, 2011 · N928LR · Cndair CL6002D24SDR ZZDA2011535Structure · corrodedGALLEY COFFEEMAKER COMPARTMENTS 101, 102 AND 103 LOWER SURFACE, CORROSION. ACCOMPLISHED LOWER SURFACE REPLACEMENT PER EA 17-25-03226IR.Jun 3, 2011 · N964AT · Boeing 717200SDR DALA1137381809Power Supply · burnedCABIN CREW DETECTED STRONG ELECTRICAL ODOR AND VISIBLE SMOKE IN FORWARD GALLEY AFTER ARRIVAL AT GATE. THE FLIGHT CREW PULLED THE UTILITY BUSSES AND CONTACTED MAINTENANCE. SMOKE DISSIPATED WITH UTILITIES OFF. MAINTENANCE FOUND THE NUMBER 2 COFFEEMAKER IN THEJun 1, 2011 · N833MH · Boeing 767432ERSDR CNMA20110029Oven · burnedAFT GALLEY OVEN FIRE. INSIDE OF 2-21. FOLLOWED QRH PROCEDURES. CONTINUED (ALL OVENS NEED TO BE CLEANED) R & R OVEN IAW 25-30 CLEANED ALL OTHER OVENS. NO EXCESS DRIPPINGS OR CRUMBS.May 26, 2011 · N531AX · Doug DC1030SDR UALA2011052402539Unknown · odorCREW REPORT ELECTRICAL ARCING IN BUSINESS CLASS GALLEY. *SUPPLEMENTAL DATA UPDATE* GROUND OPENED CEILING PANEL, CHECKED WIRE, CONNECTOR AND ELECTRICAL FEEDER, ALSO CHECKED CEILING PANEL LT ASSY AND AROUND WARMING OVEN AREA. NO DEFECT FOUND. SUSPECT WARMINGMay 23, 2011 · N220UA · Boeing 777222SDR R61A20110125Oven · malfunctionedCREW REPORTED FWD OVEN WAS SMOKING WHEN USED IN FLIGHT, NO EMERGENCY WAS DECLARED AND THE AIRCRAFT LANDED WITHOUT INCIDENT AT DEN. MAINTENANCE PLACED ITEM ON NEF 25-92-008.May 23, 2011 · N165HQ · Emb ERJ190100LRSDR DALA1135130680Coffeemaker · smokeDURING FLIGHT, CREW NOTICED SMOKE COMING FROM COFFEEMAKER IN THE G2D GALLEY. APPLICABLE CIRCUIT BREAKERS WERE PULLED AND THE SMOKE STOPPED. MAINTENANCE REPLACED THE COFFEEMAKER. WIRE HARNESS INSPECTION SHOWED NO EVIDENCE OF BURNT WIRES. OPERATIONAL CHECK WASMay 18, 2011 · N680DA · Boeing 757232SDR MASA2011051602723Coffeemaker · smokeSMOKE COMING FROM COFFEE MAKERS. FOUND NR 1 MAKER CAUSING SMOKE/ARCING. MX PULLED BREAKERS BUT CREW WOULD NOT ACCEPT PLANE WITH C/B'S PULLED. MX REMOVED COFFEE MAKER.May 14, 2011 · N928LR · Cndair CL6002D24SDR ASAA1199638Coffeemaker · malfunctionedF/A REPORTED BURNT RUBBER SMELL IN AFT GALLEY AREA NEXT TO R2 DOOR (WHERE LAV WALL JOINS FUSELAGE AREA). SMELL DISSIPATED. ACCOMPLISHED CABIN ODOR TROUBLESHOOTING IAW B737 900 AMM 05 60 00 AND FOUND AFT GALLEY I/B COFFEEMAKER THE SOURCE OF THE ODOR. REMOVEDMay 11, 2011 · N307AS · Boeing 737990SDR UALA2011051002321Oven · dirtyWARMING OVEN W32 BURNING SMELL WHEN TURNED ON. CLEANED OVEN W32, OPS CHECK NORMAL.May 10, 2011 · N785UA · Boeing 777222SDR ZZDA2011475Galley · corrodedGALLEY COFFEEMAKER COMPARTMENTS 102, 103 AND 106 LOWER SURFACE, CORROSION. ACCOMPLISHED LOWER SURFACE REPLACEMENT PER EA 17-25-03222IR.May 10, 2011 · N963AT · Boeing 717200SDR I5EA20110501Coffeemaker · odorCREW REPORTED FUMES FROM FORWARD GALLEY.May 9, 2011 · N802TJ · Boeing 7374B7SDR UALA2011050902295Plate · dirtyF/A REPORTS BURNT TOAST SMELL IN AFT GALLEY. F/A REPORTED SMELL IS STRONGER IN EMER EQUIP CUBBY. MAINT TEXT: PILOT INFORMED MECHANIC AFTER APPROX 1 HR OF FLIGHT TURNED OFF ALL GALLEY POWER AND SMELL WENT AWAY. PILOT LEFT GALLEY POWER OFF REST OF FLIGHT. RMay 8, 2011 · N494UA · Airbus A320232SDR DALA1132135501Oven · malfunctionedFORWARD GALLEY OVENS HAD FUMES AND SOME SMOKE 5 MINUTES AFTER TAKEOFF. OVENS WERE TURNED OFF AND LEFT, CTR, AND RIGHT OVEN CIRCUIT BREAKERS WERE PULLED. NO FURTHER FUMES OR SMOKE PRESENT FOR REMAINDER OF FLIGHT. RESET CIRCUIT BREAKERS AND TURNED OVENS ON HIMay 7, 2011 · N501US · Boeing 757251
Back to JASC 2530