SDR UALA2011050302172Circuit Breaker · faultyCB'S ARE TRIPPING. ASSURE ALL WIRING THAT WAS EFFECTED UNDER EG5429 WAS DONE PROPERLY AND IS PROPERLY ROUTED. AFTER REPLACEMENT OF CB 9002ML3 AND REPLACEMENT OF 9004ML3 CB ALL CB AND GALLEY EQUIPMENT CHILLERS,WORK LIGHTS, COFFEEMAKERS & CBS OP CHECKED OKAY.SDR AALA20110430LHR01Oven · inoperativeLHR - CREW REPORTED BUSINESS CLASS GALLEY OVEN NUMBER 4 HAD STRONG SMELL OF BURNING ELECTRICAL ODOR. CREW SHUT OFF OVEN AND PULLED CIRCUIT BREAKER. FLIGHT LANDED LHR WITHOUT INCIDENT. DEFERRED NUMBER 4 OVEN AS INOPERATIVE. SYSTEM GROUND CHECK NORMAL OPERATSDR UHLA2011042900153Coffeemaker · odorON CLIMBOUT, PASSING THROUGH 20,000 FEET, F/A CALLED FLIGHT DECK REPORTING A SMOKY ODOR IN THE AFT GALLEY. THERE WAS NO VISIBLE SMOKE. LEVELED OFF AT FL240, DIVERTED. ATC DECLARED AN EMERGENCY. WHILE STARTING DESCENT, F/A REPORTED THE ODOR HAD DISSIPATED SDR DALA1130033303Controller · defectiveON DESCENT FLIGHT ATTENDANT DETECTED ELECTRICAL OR PLASTIC SMELL IN FORWARD GALLEY NEAR CENTER OVERHEAD PANEL. GALLEY POWER WAS TURNED OFF AND SMELL DISSIPATED AND LANDING WAS UNEVENTFUL. FOUND FORWARD GALLEY NR 3 OVEN CONTROLLER DEFECTIVE, REPLACED OVEN WITHSDR ZZDA2011430Shelf · corrodedGALLEY COMPARTMENTS 102, 103, 106 SHELF, CORROSION. ACCOMPLISHED SHELF REPLACEMENT PER EA 17-25-03119IR.SDR FDEA201104281653Tie Rod · wrong partCABIN, GALLEY G1A OTBD ATTACHMENT ROD FOUND TO BE TOO LONG. CANNOT LOCATE GALLEY IAW WIC. REPAIR CARRIED AS PER E.A. F-2530-146469. REPAIR IS CLASSIFIED AS MAJOR.SDR UALA2011042802066Circuit Breaker · trippedCHILLER C-51-AFT GALLEY POPPED AFTER 3+32. SUPPLEMENTAL DATA UPDATE RESET CB ON GROUND, CIRCUIT BREAKER POPPED AGAIN AFTER 1.5 HOURS. C51 CIRCUIT BREAKER PULLED AND LOCKED OUT. "TEST IS A TEST CHILLER" WE DID RPL THE RELAY & FOUND IT'S CONTACTS BURNT. BEFORESDR SWAA113189Coffeemaker · faultyON DESCENT FLIGHT ATTENDANT REPORTED A STRONG ELECTRICAL SMELL IN AFT GALLEY. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR YENA20110427242Coffeemaker · burnedDURING CRUISE - CREW REPORTED BURNING PLASTIC SMELL IN FWD GALLEY. GALLEY WORK LIGHTS AND COFEE POTS WERE TURNED OFF AND SMELL DISAPPEARED. FOUND SOURCE OF ODOR COMING FROM NR 1 COFFEEMAKER. R & R COFFEEMAKER IAW AMM 25-37-03. OPS CK GOOD.SDR DALA1128491708Oven · contaminatedCREW SMELLED BURNING PAPER IN THE AFT GALLEY AND PULLED THE GALLEY CIRCUIT BREAKER AND THE ODOR WENT AWAY. FOUND PAPER IN AFT GALLEY OVENS AND CLEANED. AS A PRECAUTION RAN ALL OVENS IN AFT GALLEY. SYSTEM OPERATION IS NORMAL.SDR SWAA112993Rail · faultyFLIGHT ATTENDANT REPORTED SMOKEY SMELL MOMENTARILY IN FRONT LAV/GALLEY AREA. INSPECTED AND FOUND EVIDENCE OF EXCESSIVE HEAT AT FWD COFFEEMAKER RACK. REMOVED AND REPLACED RAIL ASSY PER MM.SDR CA110415003Receptacle · meltedDURING A HEAVY MX CHECK, THE BASE FOR THE COFFEE MAKER ON ACFT WAS FOUND TO BE MELTED FROM THE HEATING ELEMENTS. BASE REPLACED.SDR DALA1125200699Oven · odorJUST PRIOR TO DESCENT THE FLIGHT ATTENDANT ADVISED OF BURNING SMELL COMING FROM THE 1R AFT GALLEY OVEN. FLIGHT ATTENDANT PULLED ALL GALLEY CIRCUIT BREAKERS AND THE SMELL ABATED. FLIGHT CONTINUED TO ATL AND LANDED WITHOUT INCIDENT. DEACTIVATED AFT OVEN IN FSDR SIMA201109802Unknown · odorON FLIGHT 3364 THE FLIGHT ATTENDANT REPORTED AN ELECTRIC ODOR NEAR THE HOT JUG MOUNT, NO HOT JUGS INSTALLED. THE AIRCRAFT WAS REMOVED FROM SERVICE. INSPECT BOTH COFFEE POT RECEPTACLE PLUG, COFFEE POT CONTROL MODULE, ELECTRICAL CONNECTION ABOVE GALLEY, VISUAL SDR UALA2011040401590Coffeemaker · faultyELEC SMELL IN GALLEY, FLIGHT DIVERTED. INVESTIGATED AFT GALLEY, FOUND NO EVIDENCE OF FIRE DAMAGE RELATED TO OVENS, ELECTRICAL PANELS, LIGHT PANELS AND LIGHT FIXTURES. DID FIND EVIDENCE OF ELECTRICAL ARCING BEHIND COFFEEMAKERS IN AFT GALLEY. ELECTRICALLY ISOSDR HNAA2011041200072Socket · meltedELECTRIC SMELL IN AFT CABIN AREA. INSPECTED OVERHEAD LIGHTS IN CABIN, NO DEFECTS NOTED, FOUND SOCKET IN NR 1 LIQUID WARMER MELTED. R & R ASSOCIATED CIRCUIT BREAKER FOR THE WARMER.SDR DXTA2011040104534Control Panel · failedON THE GROUND CABIN GALLEY COOLING FAN SOUND UNUSUALLY LOUD, ALMOST GRINDING SOUND. AFTER 5-10 MINUTES A BURNING ODOR WAS NOTICED IN THE CABIN. ONCE GALLEY POWER WAS TURNED OFF WITH THE PEDISTAL PUSHBUTTON, THE FAN STOPPED AND SHORTLY AFTER THE ODOR DISAPATED.SDR DALA1123141808Screen · dirtyAIRCRAFT DIVERTED TO MIA BECAUSE OF A BUZZING NOISE AND ELECTRICAL ODOR IN AFT GALLEY. BOTH THE BUZZING NOISE AND THE ELECTRICAL ODOR DISSIPATED AFTER GALLEY POWER WAS TURNED OFF. MAINTENANCE REPLACED THE RIGHT AFT FLOOR LAMP. ADDITIONALLY, MAINTENANCE FOUNSDR USAA20110329BB023Door Seal · wornCLT FLT 1035 EN ROUTE SJU TO CLT. THE CABIN CREW REPORTED A MOMENTARY "BURNED RUBBER" ODOR IN THE AFT GALLEY OF THE AIRCRAFT. THE ODOR DISSIPATED ON ITS OWN. THE FLIGHT CONTINUED AND LANDED IN CLT WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND THE DOOR SEALSDR DALA1121893303Oven · defectiveDURING FLIGHT AFT GALLEY OVEN 3-47 BREAKER POPPED WHILE COOKING AND SOME SMOKE WAS OBSERVED. FOUND BACK WALL LOOSE, REPLACED OVEN AND TESTS OK.SDR DALA1121756710Coffeemaker · contaminatedFLIGHT 2621 SLC-LAX EXECUTED AN AIR RETURN DUE TO SMOKE IN THE AFT GALLEY. MAINTENANCE FOUND TIE WRAP MELTED ON COFFEE MAKER HOT PLATE. COFFEE MAKER WAS REPLACED. OPERATIONAL CHECK WAS GOOD.SDR SWAA112003Coffeemaker · malfunctionedON DESCENT FLIGHT ATTENDANTS CALLED STATING A STRONG "ELECTICAL BURNING" ODOR IN CABIN. REMOVED AND REPLACED NR 2 COFFEEMAKER PER MM.SDR AALA20110319LHR01Coffeemaker · faultyLHR - CREW REPORTED NUMBER 8 COFFEEMAKER HAS STRONG ELECTRICAL ODOR. FLIGHT LANDED LHR WITHOUT INCIDENT. REPLACED NUMBER 8 COFFEEMAKER. SYSTEM GROUND CHECK NORMAL OPERATION.SDR DALA1121640182Chiller · malfunctionedGALLEY AFT CHILLER C/B POPPED WITH AN ASSOCIATED ELECTRICAL SMELL. FORWARD TO NEF MAINTENANCE COULD NOT DUPLICATE FAULT. SYSTEM OPERATION IS GOOD.SDR ASAA1159277Oven · odorDURING CRUISE FLIGHT ATTENDANTS REPORTED ACRID IRRITATING ELECTRICAL SMELL COMING FROM FORWARD GALLEY OVEN AREA. CONFIRMED BY CAPTAIN AND CHECK AIRMAN. TURNED OFF GALLEY POWER AND PULLED C/B FOR OUTBOARD OVEN (INBOARD OVEN C/B ALREADY OPEN PER MEL). FUMES RSDR VNAA2011032200015Coffeemaker · damagedCREW REPORTED ODD FUMES AND SMELL FROM COFFEEMAKER IN FLIGHT. AT CLT, MAINTENANCE INSPECTED, FOUND BENT AND MELTED PIN ON COFFEEMAKER CONNECTOR, REMOVED AND REPLACED COFFEEMAKER AND PERFORMED CHECKS USING AIRCRAFT MAINTENANCE MANUAL. AIRCRAFT WAS RELEASED FOSDR AALA20110318TUL01Oven · malfunctionedHNL - INFLIGHT OGG-LAX. FLIGHT ATTENDANTS REPORTED FORWARD GALLEY OVEN OVERHEATED. FIRE EXTINGUISHERS WERE USED. EMERGENCY DECLARED FLIGHT DIVERTED HNL LANDED WITHOUT INCIDENT. FOOD DEBRIS NOTED AS SOURCE. FORWARD GALLEY OVEN PLACARD INOPERATIVE. REPLACESDR DALA1119357105Oven · malfunctionedNUMBER 2 OVEN (A815) IN MID-RIGHT AFT GALLEY HAD SMOKE COMING OUT WHEN TURNED ON. OVEN WAS TURNED OFF AND NOT USED. MAINTENANCE REMOVED OVEN AND INSPECTED SURROUNDING AREA. NO ARCING, NO ELECTRICAL SMELL, AND NO DISCOLORATION WAS FOUND. MAINTENANCE ALSO CHSDR USAA2011031191021Coffeemaker · odorFLT 400 - DURING CRUISE, 2 FLIGHT ATTENDANTS IN AFT GALLEY SMELLED ELECTRICAL BURNING ODOR, NO VISIBLE SMOKE. ODOR DISSIPATED AFTER 2 MINUTES. FOUND AFT NR 1 COFFEEMAKER CIRCUIT BREAKER POPPED AND THERMAL BUTTONS POPPED ON BACK OF COFFEEMAKER. REMOVED AND RSDR DALA1116249217Coffeemaker · odorF/A REPORTED ELECTRICAL ODOR IN FIRST CLASS GALLEY. FLIGHT CREW PERFORMED QRH, PULLED THE GALLEY POWER SWITCH OFF, AND THE ODOR DISSIPATED. MX OPERATED FWD GALLEY OVEN AND COFFEEMAKERS BUT NO SMOKE OR ODOR WAS NOTED. SOME SPILLED/BURNED COFFEE WAS FOUND ONSDR ZZDA2011289Structure · corrodedGALLEY COFFEEMAKER COMPARTMENTS 102, 103 AND 106 LOWER SURFACE, CORROSION. ACCOMPLISHED LOWER SURFACE REPLACEMENT PER B717 SRM 51-40-00, 51-40-02, 51-41-02, 51-20-05 AND EA 17-25-03115IR.SDR ZZDA2011260Structure · corrodedCOFFEEMAKER COMPARTMENT 102 AND 106, CORROSION. ACCOMPLISHED 102 AND 106 DOUBLER REPAIR PER B717 EA 17-25-03111IR.SDR ZZDA2011249Structure · corrodedGALLEY COFFEEMAKER COMPARTMENTS 102, 103 AND 106 LOWER SURFACE, CORROSION. ACCOMPLISHED LOWER SURFACE PANEL REPLACEMENT PER EA 17-25-03110IR.SDR DALA1114705804Oven · contaminatedFLIGHT ATTENDANTS REPORTED SMOKE IN THE FORWARD GALLEY AT OVEN START UP. MAINTENANCE CHECKED GALLEY CEILING AND FIXTURES. THE NR 1 OVEN WAS FOUND WITH A PLASTIC SUBSTANCE NEAR THE HEATING COIL. SUBSTANCE WAS CLEANED AND OVEN OPERATED NORMALLY WITH NO ODORS.SDR UALA2011022100870Oven · odorCREW REPORTED AN ELECTRICAL ODOR IN AREA OF ROWS 19 TO 26. CREW SELECTED DOOR 2 AREA GALLEY POWER SWITCH TO OFF AND ODOR CLEARED. CLEANED OVEN SURFACE. OPERATED ALL GALLEY EQUIPMENT, NO ODOR NOTED.SDR UALA2011022100882Oven · smokeOVEN IN 1ST CLASS GALLEY LOCATION 428, UPON START UP, THE OVEN STARTED TO SMOKE F/A UNABLE TO IDENTIFY SOURCE OF SMOKE. SAMC TEXT: F/A SELECTED OVEN TO OFF AND SMOKE CLEARED. DEFERRED OVEN 11 IN FIRST CLASS IAW MEL. REPLACED FIRST CLASS OVEN IAW MM.SDR CALA2011021500093Warmer · odor1.5 HR INTO FLT, F/A'S REPORT THE BURNT WIRE SMELL IS BACK. DOES NOT APPEAR TO BE COMING FROM AIR VENT BUT IS PRESENT IN ACFT GALLEY. COFFEEMAKERS & OVENS WERE OFF AND NOT USED. TURNED OFF GALLEY POWER. F/A REPORT SMELL LIGHTER NOW, 10-15 MINUTES LATER OPSSDR CALA2011021000080Oven · malfunctionedOVEN 411 AFT GALLEY OVEN STARTED BELLOWING HEAVY SMOKE. THE SMOKE APPEARED TO BE COMING FROM THE METAL VENT ON TOP OF THE OVEN NOT FROM INSIDE C/B POPPED AND NOT RESET. DUE NIL SPARE FWD TO PLA C/N 541504 C/B PULLED AND COLLARD. REMOVED AND REPLACED OVEN ANDSDR 2011FA0000074Power Supply · shortedF/A SMELLED SMOKE AND SAW SMOKE COMING FROM BEHIND THE MICROWAVE OVEN. ON FEB. 4, 2011, THE ARTICLE IN QUESTION WAS RECEIVED AT REPAIR STATION. INVESTIGATION FOUND THAT A WIRE INSIDE THE METAL POWER SUPPLY BOX HAD CHAFED ON AN ADJACENT COMPONENT. THE METAL SDR UALA2011020300586Oven · contaminatedCREW REPORTED PLASTIC BURNING ODOR FROM WARMING OVEN R13. FOUND PLASTIC BURNED ODOR FROM INSIDE OF R13 WARMING OVEN. CLEANED THIS OVEN INSIDE AND CHECKED OK. NO ELECTRICAL ODOR FOUND.SDR UALA2011012600432Coffeemaker · failedCOFFEEMAKER INOP. UPPER DECK GALLEY. BREWS WITHOUT POT IN PLACE -REPLACED COFFEEMAKER.SDR SWAA110410Coffeemaker · faultyDECLARED EMERGENCY. AFT COFFEE MAKER STARTED SMOKING, SHUTOFF GALLEY POWER. REMOVED AND REPLACED AFT COFFEE MAKER PER MM.SDR DALA1103779208Oven · odorON FLIGHT 1497, CABIN CREW REPORTED A BURNING ODOR ORIGINATING FROM GALLEY OVEN WHEN IN THE ON POSITION. CIRCUIT BREAKER WAS PULLED AND ODOR DISSIPATED. MX CLEANED HEATING ELEMENTS, OPERATED OVEN AND OVEN NOW CHECKS NORMAL.SDR FDEA201101170221Tie Rod · mismanufacturedDURING GALLEY G1A MOD, FOUND GALLEY TIE ROD TOO SHORT. COMPLIED EA F-2530-142524 (GALLEY G1A INSTALLATION TIE ROD ASSY). REPAIR IS CLASSIFIED AS MAJOR.SDR CA110117001Oven · smokeCABIN CREW REPORTED WHITE SMOKE FROM THE AFT GALLEY OVEN. CIRCUIT BREAKER PULLED.SDR C2XA11RI007Unknown · odorFLIGHT 2599 - EWR - FLIGHT CREW REPORTED BURNING SMELL (ELECTRICAL) FROM COFFEE POTS. EWR MX PERFORMED OPERATIONAL CHECK OF COFFEE MAKERS AND FOUND NO DEFECTS FOUND. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR C77A357971Coffeemaker · odorRETURN TO GATE FOR STRONG ELECTRICAL BURNING ODOR IN AFT GALLEY/AFT OTBD HOT. REMOVED AND DEACTIVATED THE AFT COFFEEMAKERS IAW EO E175-2500-037, REV 1R ACCOMPLISHMENT INSTRUCTIONS. REF W/O 358284. COFFEMAKER REMOVED AND SENT TO ACFT SERVICES TO CONFIRM FINDINSDR USAA20110118BB005Galley · dirtyCLT FLT 884 EN-ROUTE CUN TO CLT. THE FLIGHT ATTENDANTS REPORTED THAT THE AFT GALLEY HAD AN ODOR DURING THE FLIGHT. MAINTENANCE FOUND MILDEW AND FOUL ODOR UNDER COFFEEMAKERS AND GALLEY DRAIN IN AFT GALLEY, AIRCRAFT RIGHT. CLEANED AND DISINFECTED THE GALLEYSDR UALA2011011200166Oven · contaminatedCREW REPORTED ODOR OF SMOKE IN COCKPIT DURING DESCENT. TURNED OFF GALLEY POWER & ODOR WENT AWAY. CHECKED THE FWD GALLEY OVEN AND COFFEE WARMERS FOR OPERATION AND POSSIBLE BURNED FOOD OR DAMAGE. INSPECTED OVENS, FOUND TWO BADLY SCORCHED TAGS FROM MEALS, RAN CSDR C2XA11CL007Coffeemaker · contaminatedTHE CREW REPORTED A BURNING SMELL IN THE GALLEY. MAINTENANCE INSPECTED AND FOUND PLASTIC DEBRIS ON THE NR 2 COFFEE POT. REMOVED DEBRIS AND OPERATIONAL CHECKS WERE GOOD.
Back to JASC 2530