SDR DL764050098Coffeemaker · arcedNR 2 MID GALLEY COFFEEMAKER INOP. C/B POPPED AFTER ARCING OCCURRED. REPLACED SAME.SDR DLM88050083Coffeemaker · smokeSMOKE IN FWD CABIN AND COCKPIT. UPON INSPECTION, DETERMINED FWD GALLEY COFFEEMAKER TO BE SOURCE. REPLACED SAME.SDR AALA20050076Oven · dirtyAUS - INFLIGHT CREW REPORTED SMOKE IN FIRST CLASS GALLEY. FOUND NUMBER ONE OVEN DIRTY AND SMOKING AROUND HEATER ELEMENT. STEAM CLEANED NUMBER ONE OVEN. RAN OVEN ONE HOUR AND CLEANED ELEMENTS AND INTERIOR OF OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR DL777050065Coffeemaker · shortedGALLEY 431 COFFEEMAKER 410 SHOCKED F/A. REPLACED SAME.SDR DL76S060058Oven · odorFWD GALLEY LOWER OVEN HAS AN ODOR OF BURNING RUBBER WHEN ON. REPLACED OVEN, OPS CKECKS OK.SDR DL738050025Oven · odorFLT ATTENDANT SMELLED ELECT SMOKE FROM SEAT AT 1L DOOR. PERSISTED 3 TO 4 MIN, THEN DISSIPATED. A/C RETURNED TO JFK. FLT ATTENDANT REPORTED SMELL ONLY, NO SMOKE. SUSPECT RESIDUAL FUMES FROM DEACT OVEN, IN FWD GALLEY. REMOVED CONNECTORS FROM OVEN AND DEACT SDR CA050111003Oven · fire(CAN) FAULT: JUST PRIOR TO DESCENT, SOMETHING WAS BEING COOKED IN THE MID CABIN GALLEY. AS THE F/A WAS ABOUT TO REMOVE IT, A FIRE WAS FOUND AT THE BACK OF THE OVEN. 3 FIRE EXT. WERE USED TO DOUSE THE FIRE. NO EMERGENCY WAS DECLARED, NO ADVERSE PAX REACTION.SDR AALA20050021Oven · dirtyDFW - SHORTLY AFTER TAKEOFF SMOKE CAME THROUGH BOTTOM OF COCKPIT DOOR. AIRCRAFT RETURNED TO DFW AND LANDED OVERWEIGHT AT 135,000 WITHOUT INCIDENT. FOUND FIRST CLASS OVEN NUMBER 212 POSITION SMOKING. CLEANED AND REMOVED GREASE FROM OVEN. ACCOMPLISHED OVERWESDR YENA200464Pin · burnedSMOKE SMELL REPORTED AROUND COFFEEMAKERS IN FWD GALLEY. FOUND BURNT PIN ON NR 2 COFFEEMAKER. AIRCRAFT RELEASED UNDER MEL 25-22-03 CONTROL L03922. UPON ARRIVAL AT JFK FIXED TRAY TO NR 2 COFFEEMAKER. REMOVED AND REPLACED NR 2 COFFEEMAKER AND OPS CHECK NORMALSDR 2004UALA01249Smoke · detectedFLIGHT ATTENDANT SAW SMOKE COMING FROM AFT GALLEY TRASH COMPACTOR AREA. LINE MAINTENANCE ACCOMPLISHED A DETAILED INSPECTION AND OPERATIONAL CHECK ON THE SUSPECT TRASH COMPACTOR. NO EVIDENCE OF SMOKE WAS FOUND ON THE DETAILED INSPECTION, AND A SUBSEQUENT OPERASDR YENA200461Coffeemaker · odorODOR IN THE REAR GALLEY OF BURNED ELECTRICAL SMELL. F/A CHECKED AREA AND FOUND SMELL IS COMING FROM ONE OF THE REAR COFFEEMAKERS. UNITS WERE SHUTOFF & SMELL WENT AWAY. REPLACED NR 2 AFT GALLEY COFFEEMAKER PER 25-35-15. OPERTIONS CHECK GOOD.SDR DL76L041097Chiller · failedSTRONG ELECTRICAL ODOR IN FWD CABIN AREA. ISOLATED COMPONENTS AND FOUND FWD GALLEY CHILLER TO BE THE CAUSE. REPLACED SAME.SDR WLDA2004110Oven · contaminatedCENTER GALLEY OVERHEAD LIGHT EMITTED ELECTRICAL SMELL. INVESTIGATED ELECTRICAL SMELL IN MID GALLEY AREA. CHECKED OVERHEAD LIGHTS AND ELECTRICAL CONNECTIONS, NO EVIDENCE OF ARCING OR BURNT CONNECTIONS, CHECKED ELECTRICAL CABLES FOR SIGNS OF DAMAGE, NONE EVIDESDR DL76G041064Oven · odorSTRANGE ELECTRICAL SMELL FROM FWD GALLEY. ALSO STRANGE VIBRATION NOISE LIKE A LOOSE FAN POSSIBLY. DEPOWERED FWD GALLEY, NOISE AND SMELL STOPPED. FOUND NR 1 OVEN IN FWD GALLEY C/B POPPED. REPLACED SAME.SDR YENA200455Coffeemaker · odorAPPROX 25 MINS INTO FLT AT 370 NR 1 F/A CONTACTED FLT DECK REPORTING STRONG BURNING ODOR AROUND NR 1 GALLEY & GETTING STRONGER. ODOR SEEMED TO BE COMING FROM VENTS. PERFORMED SMOKE/AVIONICS SMOKE CHECKLIST IAW QRH 1.10, SMELL INTENSIFIED. PERFORMED SMOKE/TOSDR DL738041050Chiller · odorCREW REPORTED BURNING ODOR FROM FORWARD GALLEY CHILLER. TURNED CHILLER OFF AND SMELL WENT AWAY. REPLACED CHILLER.SDR RAIA00411018Connector · burnedRIC - SMELL IN CABIN. MAINTENANCE INSPECTED HOT JUGS AND FOUND BOTH CONNECTOR BURNED. REMOVED AND REPLACED HOT JUG CONNECTORS.SDR DL75K041014Coffeemaker · dirtyFAINT SMELL, POSSIBLE BURNING ELECTRICAL TYPE ODOR NOTICED BY AFT GALLEY AREA. NOTICED BY F/A ON DESCENT. UTILITY BUSSES WERE TURNED OFF. NO SMELL NOTICED. FOUND COFFEEMAKER DIRTY WITH COFFEE GROUNDS.SDR 2004UALA01007Receptacle · burnedFLAME CAME OUT OF SERVICE OUTLET AFTER SWITCHING TO EXTERNAL POWER BY DOOR 1L. ELECTRICAL OUTLET AT DOOR 1 LEFT WAS FOUND MELTED. OUTLET WAS REPLACED AND OP CHECKED GOOD. ENGINEERING WILL EVALUATE THE ELECTRICAL OUTLET TO LOOK FOR POSSIBLE DEFECTS. ENGINESDR DL73S040966Connector · shortedAFT GALLEY NR 2 COFFEEMAKER C/B POPPED. LATER TRASH CAN FILLED UP WITH WATER. WATER SUPPLY SHUT OFF. REMOVED BOTH COFFEEMAKERS. FOUND ARCING ON NR 2 COFFEEMAKER CANNON PLUG. TURNED WATER SUPPLY ON. CANNOT FIND SOURCE OF LEAK. REPLACED BOTH COFFEEMAKERS SDR DL76G040943Odor · detectedF/A IN FWD GALLEY REPORTED AN ELECTRICAL ODOR. LEAD F/A COULD NOT SMELL ANY UNUSUAL ODOR. ODOR STOPPED SOON AFTER INITIALLY DETECTED. F/A WHO COMPLAINED REPORTED IT MAY BE THE BUN WARMER. BUN WARMER SHOULD BE CHECKED. CHECKED FWD GALLEY AREA. NO PROBLEMSSDR DL76L040934Odor · detectedMID GALLEY FREEZER GAVE OFF AN ELECTRICAL SMELL. DEACTIVATE FREEZER AND FWD TO MCO. C/B PULLED AND COLLARED.SDR BA04022Coffeemaker · malfunctionedPIT - FL 781 - APPROXIMATELY FIVE MINUTES PRIOR TO LANDING, A STRONG ELETRICAL SMELL WAS NOTED IN THE FORWARD GALLEY. AFTER THE CIRCUIT BREAKER WAS PULLED, THE SMELL SUBSIDED. MAINTENANCE REPLACED THE FORWARD GALLEY COFFEE MAKER.SDR DL76S040867Coffeemaker · contaminatedDIVERTED TO KJFK WITH REPORTED FUMES IN AFT GALLEY. UNKNOWN SOURCE, BUT REPORTED AS BURNING PLASTIC ODOR, WHICH DID NOT GO AWAY EVEN AFTER TURNING OFF UTILITY BUSSES AND RECIRC FANS. ATL/TMC NOTIFIED AT 1055Z. AFTER OPERATING NR 4L COFFEEMAKER FOUND DEBRIS SDR DL733040830Oven · odorACRID SMOKE COMING FROM ELECTRICAL CONTROL PANEL ABOVE OVENS IN AFT GALLEY. FOUND L2 DOOR GALLEY OVEN AND CONTROLLER SMELLING OF SMOKE. CHECKED GALLEY AREA FOUND NO ELECT DAMAGE. RE-INSTALLED OVENS AND CONTROLLERS. REPLACED OVEN AND CONTROLLER.SDR GTIA040750Coffeemaker · odorFLT 308 - DTW - A BURNING SULPHER ODOR IN FLIGHT DECK AND FORWARD GALLEY NO SMOKE WAS PRESENT F/A CHECKED GALLEY AND FOUND COFFEE MAKER C/B POPPED. REMOVED AND REPLACED FORWARD COFFEE MAKER. (M)SDR 0401426312Oven · overheatedDURING FLIGHT, SMOKE EMITTED FROM THE 2-7 OVEN AS IT OPERATED HOTTER THAN THE MEDIUM SETTING CAUSING THE SMOKE ALARM TO ACTIVATE. THE OVEN WAS TURNED OFF AND THE CIRCUIT BREAKERS PULLED AND THE SMOKE DISSIPATED SILENCING THE SMOKE ALARM. AIRCRAFT CONTINUED TO SDR 2004UALA00847Oven · contaminatedGALLEY OVEN INOPERATIVE AT FWD CAB, FWD RT GAL HAD ISOLATED SMOKE OVERHEAT IN OVEN, CB PULLED. NO ADDITONAL PROBLEM. PLASTIC MATERIAL WAS INGESTED INTO THE FAN AREA THAT MIGRATED TO THE OVEN HEATER ELEMENTS, POSSIBLY CAUSING MINOR IGNITION OF THE FLAMMABLE PLSDR DL764040759Coffeemaker · sparksCOFFEMAKER IN AREA 206, FIRST CLASS GALLEY, SPARKING FROM COLD WATER BUTTON. REPLACED SAME.SDR AALA20040793Coffeemaker · inoperativeCLE - INFLIGHT T259/31 AIRCRAFT LANDED CLE WITH SMOKE REPORTED IN CABIN. FOUND BURNED WIRES IN NUMBER ONE COFFEEMAKER IN FIRST CLASS GALLEY. PLACARD NUMBER ONE COFFEEMAKER IN FIRST CLASS GALLEY AND REPLACED NUMBER ONE COFFEEMAKER IN FIRST CLASS GALLEY IN LASSDR DL757040690Odor · detectedON TAXI OUT UNIDENTIFIED ODOR POSSIBLY ELECTRICAL NOTED IN AFT PART OF A/C NEAR AFT F/A. UNABLE TO CONFIRM, IDENTIFY, OR LOCATE SOURCE. CHECKED FOR ODOR IN AFT CABIN AREA, NONE FOUND. CHECKED AFT CARGO COMPT AND AFT E/E RACK, NO ODOR DETECTED.SDR 0401243150Coffeemaker · odorDURING CRUISE, FLIGHT ATTENDANT REPORTED A BURN SMELL/SMOKE IN THE FRONT GALLEY. TURNED OFF GALLEY POWER AND COMMERCIAL POWER. DIVERTED TO BUF AND LANDED UNEVENTFULLY. FOUND THE COFFEEMAKER HEATING ELEMENT MELTED AND LEAKING. DEACTIVATED THE COFFEEMAKER ANSDR DL764040664Coffeemaker · sparksCREW REPORTED RIGHT AFT GALLEY COFFEEMAKER HAD SPARKS AT TOD CREW PULLED COFFEEMAKER CIRCUIT BREAKER. SPARKS STOPPED. INSPECTED WIRE HARNESS FOR RT COFFEEMAKERS. NO EVIDENCE OF ARCING OR FAILURE ON NR 3 COFFEEMAKER. ALSO FOUND A ELECTRICAL PLUG FOR NR 3 COSDR SWAA041954Coffeemaker · faultyELECTRICAL ODOR IN AFT GALLEY REPORTED. REMOVED AND REPLACED BOTH AFT COFFEEMAKERS PER MM.SDR 0401146309Coffeemaker · smokeDURING FLIGHT, THE NR 2 COFFEEMAKER IN THE NR 1 GALLEY STARTED SMOKING. PULLED CIRCUIT BREAKER AND THE AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED COFFEEMAKER. OPERATIONAL CHECK GOOD.SDR DL76L040627Oven · wornAFT GALLEY UPPER OVENS ON F/O SIDE IS BURNING THE WALL. FOUND DOOR SEAL ON OVEN WORN. REPLACED OVEN.SDR DL733040604Odor · detectedFLIGHT ATTENDANT SMELLS BURNING ODOR IN AFT GALLEY. INSPECTED AFT GALLEY EQUIPMENT FOR DEFECTS, NONE NOTED. NO SMELL PRESENT. APPLIANCES AND LIGHTS ALL CHECK NORMAL. OK FOR SERVICE.SDR GTIA040630Coffeemaker · odorFLT 931 - ORD - LEAD F/A OBSERVED A BURNING SMELL FROM FORWARD GALLEY COFFEE MAKER. THE LIGHT THEN WENT OUT CAPTAIN TURNED OFF GALLEY POWER, SMELL STOPPED. RESET C/B ON BACK OF COFFEE MAKER AND RALAMPED POWER LAMP, PERF BREWING OPS CHECK GOOD. NO LEAKS NOTESDR GTIA040575Lanyard · looseLGA - FLT 1581 - UPON ARRIVAL R1 SLIDE COVER LANYARD CAME LOOSE. REATTACHED LANYARD. NO DEFECTS NOTED. (M)SDR CA040617006Relay · failedCOFFEEMAKER WAS REMOVED DUE TO TRIPPING CIRCUIT BREAKER. STRIP REPORT REVEALED THAT THE UNAPPROVED RELAY WAS FITTED TO THE COFFEEMAKER. CORRECT P/N KR-90693-1 P/N FOUND KR 14DGE24.SDR YENA200433Coffeemaker · smokeF/A REPORTED NR 2 COFFEEMAKER WAS SMOKING. TURNED OFF COFFEEMAKER AND SMOKE DISSIPATED. PULLED C/B FOR NR 2 COFFEEMAKER. REMOVED COFFEEMAKER AFTER OPS CHECK. FOUND NO FAULT OR LOOSE CONNECTIONS BEHIND COFFEEMAKER. REPLACED COFFEEMAKER FOR PRECAUTIONARY RESDR AUS20040500Oven · faulty(AUS) FORWARD GALLEY OVEN FAILED. FIRE EXTINGUISHED DISCHARGED INTO OVEN.SDR CALA0400519Oven · malfunctionedTHE FLIGHT ATTENDANT'S REPORTED SMOKE AROUND THE FORWARD GALLEY APPROXIMATELY 10 MINUTES AFTER TAKEOFF FROM IAH. THE SMOKE DISSIPATED AND THE AIRCRAFT WAS RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. A SMOKE INSPECTION WAS PERFORMED AND NOTHING ABNORMALSDR DL757040465Coffeemaker · overheatedMID GALLEY COFFEE MAKER OVERHEATED, REPLACED COFFEE MAKER.SDR DLM88040456Oven · malfunctionedAFT GALLEY - FUMES (ELECTRICAL) WERE DETECTED, NO SMOKE. ALL GALLEY CB'S WERE PULLED, ODOR DISAPPEARED. FOUND FWD OVENS IN AFT GALLEY AT FAULT. REPLACED SAME.SDR DL73S040451Coffeemaker · malfunctionedDURING FLIGHT AFT CABIN ATTENDANTS NOTICE ELECTRICAL SMELL IN THE AFT GALLEY. SHORTLY AFTER SMELL STARTED SMOKE DETECTOR IN AFT LAV STARTED TO SOUND. THE C/B FOR THE AFT GALLEY COFFEEMAKER POPPED AND THE SMELL WENT AWAY. THE AFT LAV SMOKE DETECTOR CONTINUEDSDR USA2004F00047Odor · detectedCREW ADVISED OF A BURNING RUBBER ODOR IN THE AFT GALLEY. THE MAIN GALLEY POWER SWITCH WAS SECURED AND THE ODOR DISSIPATED. MAINTENANCE INSPECTED THE AREA AND OPERATED THE GALLEY EQUIPEMENT. NOT PROBLEM WAS FOUND.SDR AUS20040365Oven · faulty(AUS) AFT GALLEY OVEN ELECTRICAL FAULT. INVESTIGATION FOUND FILTERBOARD CAUGHT FIRE DUE TO THE FORMATION OF DRY SOLDER JOINTS ON INDUCTOR CONTACTS.SDR 2004UALA00443Coffeemaker · malfunctionedRETURNED TO YYZ DUE TO F-A REPORTED SPARKS AND POPPING COMING FROM FWD GALLEY CEILING ABOVE COFFEE MAKER. MECHANIC INSPECTING AIRCRAFT FOUND NO SIGNS OF ARCING OR MOISTURE ABOVE COFFEEMAKER. SUBJECT COFFEEMAKER FOUND TO FUNCTION PROPERLY. FURTHER ANALYSIS BYSDR SWAA041206Coffeemaker · faultySTRONG ELECTRICAL SMELL FROM AFT COFFEEMAKER IN FLIGHT. WHEN CB PULLED SMELL WENT AWAY. REMOVED AND REPLACED BOTH AFT COFFEEMAKERS PER MM.
Back to JASC 2530