SDR DL75K050494Coffeemaker · odorFUMES IN AIRCRAFT AT R3 AREA IN CABIN ONLY IN AFT GALLEY FL380 2 HRS INTO FLT / OPENED PANELS IN REAR GALLEY, NTF. CHECKED BEHIND C/B PANEL ALL CONNECTIONS TIGHT CHECKED CONNECTOR ON CURRENT TRANSFORMER, ALL NORMAL. CLEANED OVERHEAD VENT FILTERS. CHECKED BESDR AALA20050556Oven · fireIAH INFLIGHT T1383/26AUG - RESIDUE IN LEFT OVEN IN FORWARD GALLEY CAUGHT FIRE. FLIGHT ATTENDANT CLOSED OVEN DOOR AND FIRE EXTENGUISHED. CLEANED LEFT HEAD OVEN IN FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR QXEA200501186Coffeemaker · odorSEA FLT NR 2276, FLT ATTENDANT REPORTS AN ELECTRICAL ODOR BY THE COFFEEMAKER IN GALLEY. MAINTENANCE DEFERRED NR 1 AND NR 2 WARMERS. BOTH CIRCUIT BREAKER PULLED AND WARMER DEACTIVATED.SDR SWAA052604Coffeemaker · faultyELECTRICAL ODOR IN AFT GALLEY. REMOVED AND REPLACED BOTH AFT GALLEY COFFEEMAKERS PER MM.SDR DL76G050466Oven · odorAFT GALLEY OVEN ELEC SMELL. REPLACED SAME.SDR YENA200551Coffeemaker · odorF/A REPORTED ACRID BURNING ODOR (NO SMOKE) FROM FWD GALLEY. ODOR SUBSIDED WHEN COFFEE POTS TURNED OFF. PERFORMED TSM TASK 24-00-00-810-823, CHECKED PINS AND NOSE TERMINALS BEHIND COFFEEEMAKERS. OK TO CONTINUE. PRECAUTIONARY REPLACED BOTH COFFEE MAKERS (S/NSDR 0501296301Oven · smokeFLIGHT ATTENDANT REPORTED OVEN 3-50 CAUSED SMOKE IN GALLEY (PULLED HALON). AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. DTW MAINTENANCE MEL'D OVEN. MAINTENANCE REMOVED AND REPLACED OVEN CONTROLLER. OPERATIONAL CHECKED GOOD.SDR F3LA200500038Coffeemaker · odorAIR DIVERSION, SMOKE SMELL IN AFT GALLEY. DECLARED AN EMERGENCY. MX PERFORMED TSM TASK 24-00-00-810-823, FOUND AFT NR 2 COFFEEMAKER C/B'S POPPED ON REAR OF COFFEEMAKER. REMOVED AFT NR 1 COFFEEMAKER & INSTALLED INTO NR 2 POSITION, OPS NORMAL. NO ARCING OR DSDR AWXA200500955Thermister · failedSTRONG ELECTRICAL BURNING ODOR REPORTED BY FLIGHT ATTENDANT. ODOR COMING FROM THE AFT GALLEY. MAINTENANCE FOUND THE AFT NR 3 COFFEEMAKER HOT AND TO HAVE ODOR. REPLACED NR 3 COFFEEMAKER IAW AMERICA WEST AIRLINES TASK CARD R1D25001. OPS CHK GOOD. TEARDOWN CSDR 0501265507Oven · smokeSMOKE COMING FROM 1ST CLASS GALLEY OVEN, SUBSIDED WHEN OVEN WAS TURNED OFF. THERE WAS NO FIRE AND THE SMOKE WAS NOT FOOD RELATED PER FLIGHT ATTENDANT. OVEN WAS REMOVED AND REPLACED, AIRCRAFT RETURNED TO SERVICE.SDR 2005FA0001224Cover · meltedMICROWAVE OVEN, PN 400-1338-02-L, INSTALLED, EXPERIENCED A (SMOKE EVENT) WHILE FLYING OVER TURKEY. REP EXAMINED THE UNIT ON 8/12/2005. THE MOISTURE COVER HAD OVERHEATED DURING OPERATION WITH A LIGHT LOAD. SB-MW-02, DATED 4/25/01 TO REPLACED MOISTURE COVER WSDR DL76L050448Oven · smokeBOTH AFT GALLEY OVENS PRODUCED SMOKE. C/BS PULLED. CKD OVENS FOUND BUN BEHIND THE TRAY. OPERATED FOR 30 MINS. OPS NORM, OVEN CLEANED.SDR DL76L050425Coffeemaker · sparksFWD GALLEY COFFEE MKR INOP/SPARKING, REPLACED SAME.SDR DL76L050404Coffeemaker · smokeJUMPSEAT 4L COFFEE MAKER CB POPPED WITH SMOKE FROM COFFEEMAKER. REPLACED MAKER. CKS OK. MCO REMOVED, CKD WIRING FOR SHORTING/DAMAGE, NO TROUBLE FOUND.SDR BB05054ACoffeemaker · odorLAS FLT 697 EN-ROUTE PHL TO LAS. THE CABIN CREW NOTICED A BURNING ODOR, LIKE BURNING COFFEE, COMING FROM THE AIRCRAFT LEFT GALLEY AIR VENT. THE APPROPRIATE CIRCUIT BREAKERS WERE PULLED AND THE ODOR DISSIPATED. FLIGHT CONTINUED WITHOUT FURTHER INCIDENT. MASDR DL76L050374Coffeemaker · burnedELECTRICAL ODOR WAS DETECTED INFLIGHT AROUND THE AFT GALLEY AREA ON THE COPILOTS SIDE OF THE AIRCRAFT. F/A'S PULLED CB'S FOR THE 2 COFFEEMAKERS ON THAT SIDE AND ODOR WENT AWAY CB'S LEFT OUT FOR REMAINDER OF THE FLIGHT. UPON ARRIVAL FOUND ALL CB'S IN/RESET. SDR 0501033247Controller · failedDURING CLIMB, A BURNING ODOR WAS NOTED IN THE COCKPIT AND SMOKE/HAZE REPORTED IN CABIN. DECLARED YELLOW EMERGENCY AND RETURNED TO MEM AND LANDED UNEVENTFULLY. FOUND ROW 25 LEFT OVERHEAD FLUORESCENT LAMP INOP. FOUND NO EVIDENCE OF BURNED PINS. RELAMPED AND SDR 2005UALA00669Coffeemaker · shortedCOFFEEMAKER DELIVERED SHOCK TO FLIGHT ATTENDANT IN REAR GALLEY. UNIT TESTED ONLY AFTER BURST HEATER WAS REPLACED. CAN ONLY SPECULATE BURST HEATER CARTRIDGE IN WATER MAY HAVE BEEN SOURCE OF STRAY CURRENT. UNIT BONDING OK.SDR SWAA052045Coffeemaker · faultyDIVERSION, SMOKE SMELL IN AFT GALLEY. FOUND AFT INBOARD COFFEEMAKER CIRCUIT BREAKER TRIPPED. RESET CIRCUIT BREAKER AND REMOVED AND REPLACED AFT COFFEEMAKERS PER MM.SDR DL777050358Oven · unserviceableCREW REPORTED FWD GALLEY OVEN HAD ELEC SMELL AND SMOKE C/BS FOR OVEN PULLED BY FLT ATTENDANT SMELL STOPPED. FWD TO MCO AND PLACARD PER MEL M25-20-01H. AREA BEHIND THE OVEN INSPECTED FOR SHORTS/ELEC BURNS ALL OK.SDR YENA200538Coffeemaker · smokeFORWARD GALLEY - DURING BREW PROCESS, F/A SAW WHAT APPEARED TO BE SMOKE COMING FROM THE COFFEEMAKER. TURNED OFF POWER TO COFFEEMAKER THAT STOPPED THE SMOKE. INITIALLY THE ITEM WAS DEFERRED PER MEL 25-22-03, C/B WAS PULLED AND COLLARED. THE COFFEEMAKER WAS RSDR AALA20050417Oven · contaminatedBUSINESS CLASS GALLEY OVEN 4B SMOKES. RAN OVEN DURING GROUND TIME. FOOD AND DEBRIS CLEANED UP BY CABIN SERVICES. NO OTHER FAULTS FOUND. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ASMF200506023Valve · leakingAIRCRAFT RETURNED TO PLATFORM, WATER LEAK IN THE COFFEE MAKER OF AFT GALLEY. DURING REVISION WAS DETECTED THE FEEDING WATER VALVE LOOSEN. THE FEEDING WATER VALVE WAS REPRESSED IAW MM 20-30-02, ALL CORRECT. DURING OVERNIGHT SERVICE, THE TORQUE IN COFFEE MAKER CSDR AWXA200500725Oven · dirtyLT FWD GALLEY OVEN SMOKES DURING OPERATION. MAINTENANCE REMOVED AND REPLACED THE LT FWD GALLEY OVEN IAW AMERICA WEST AIRLINES TASK CARD F1D25303. OPERATIONAL TESTS WERE GOOD. UNIT WAS RECEIVED DIRTY. UNIT'S THERMOSTAT WAS ADJUSTED AND THE DOOR SEAL WAS REPSDR CA050614001Coffeemaker · shortedMID COFFEEMAKER IN AFT GALLEY U/S A SPARK CAME FROM IT AND IT WAS TURNED OFF BY F/A GALLEY POWER OFF.ACTION: C/M REPLACED. POS 505 AND 506 BREW CYCLE OPS CHECKED (SERV).SDR 0500896316Control Panel · sparksWHILE INBOUND TO JFK, FLIGHT ATTENDANT REPORTED U/D OVEN 1-29 RUNS TOO HOT, SPARKS AND SMOKE WERE SEEN COMING FROM CONTROL PANEL. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. JFK MAINTENANCE REPLACED OVEN AND RESEATED RELAY. OPERATIONAL CHSDR MWEA050046Drain · obstructedLOUD SQUEAL WAS AUDIBLE THROUGHOUT CABIN AND COCKPIT SEEMED TO BE IN FORWARD GALLEY. FOUND GALLEY DRAIN PLUGGED POSSIBLE CAUSE OF SQUEAL. CLEANED DRAIN, CLEANED GALLEY PASSENGER DOOR SEALS, PRESSURIZED CABIN TO 7.5 PSI, LEAK DOORS AND SEALS NO AUDIBLE SQEALSSDR CA050610001Oven · sparks(CAN) CABIN CREW NOTICED SPARKS COMING FROM RT OVEN. OVEN WAS DEACTIVATED AND REPLACED AT THE NEXT MAINTENANCE STATION. OVEN ROUTED TO REPAIR SHOP FOR INVESTIGATION.SDR U30A200500004Oven · unknownDURING CRUISE, AFT F/A SMELLED SMOKE IN AFT GALLEY (G5). OPENED NR 1 OVEN, FOUND MEALS CONTAINED IN BOXES BURNED ON END. SMALL FIRE EXISTED & EXTINGUISHED. POWER REMOVED FROM OVEN, PULLED C/B. NR 1 OVEN INSERT (CARRIER FOR MEALS) DID NOT HAVE A METAL BACK SDR 2005UALA00489Coffeemaker · sparksCOFFEEMAKER ELECTRICAL SPARKING. REPEATED ARCING NEAR MID GALLEY COFFEEMAKER PWRD OFF GALLEY & LTS. CONVERSATION WITH PURSER DESCRIBES 2 INSTANCES OF FLASH FROM BELOW COUNTERTOP AFTER POWERING OFF GALLEY. EXAMINATION OF AIRCRAFT GALLEY WIRING & COFFEEMAKERSSDR CALA0500171Oven · inoperativeTHE FLIGHT ATTENDANTS REPORTED SMOKE IN THE AFT GALLEY AND AN ASSOCIATED ELECTRICAL ODOR WHILE EN ROUTE FROM IAH TO MSP. WHEN THE GALLEY POWER WAS TURNED OFF AND OVEN CIRCUIT BREAKERS WERE PULLED THE SMOKE BEGAN TO DISSIPATE. THE AIRCRAFT WAS DIVERTED TO OKCSDR ASOA05451Coffeemaker · odorFLT 4914 - DURING CRUISE FROM SLC-LAX, THE CREW NOTICED WHAT APPEARED TO BE AN ELECTRICAL ODOR AT THE COFFEE POTS WITH NO VISIBLE SIGNS OF SMOKE AND TURNED OFF THE COFFEE POTS. THE AIRCRAFT LANDED SAFELY IN LAX. MAINTENANCE INSPECTED THE FORWARD GALLEY LIGHTSDR AWXA200500586Heating Element · shortedLAS - AIR TURN BACK - FLT 797 - ON CLIMB-OUT FROM LAS EN ROUTE TO PDX FLIGHT ATTENDANT REPORTED SMOKE AND A LOUD POP FROM THE FWD COFFEEMAKER. MAINTENANCE DISCOVERED THE WATER HEATER ELEMENT SHORTED. MAINTENANCE REMOVED COFFEEMAKER AND COLLARED CIRCUIT BREAKSDR 2005UALA00444Thermister · damagedBANG THEN SMOKE COMING OUT OF TOP OF COFFEEMAKER. STRONG ELECTRICAL BURNING ODOR. MANUFACTURERS OF COFFEEMAKER AND RELAY CONFIRM FAILURE OF THE ELECTROMECHANICAL RELAY WHICH HAD REACHED ITS SERVICEABLE LIFE. RELAY FAILURE LED TO WATER TANK OVERHEAT AND MELTSDR CA050509001Oven · smoke(CAN) DEPARTING, DURING CLIMB, SMOKE/HAZE WAS OBSERVED EMINATING FROM THE AFT CABIN AREA. THE AIRCRAFT DECLARED AN EMERGENCY AND RETURNED TO POINT OF DEPARTURE, LANDING WITH NO FURTHER INCIDENT. THE SOURCE OF THE SMOKE WAS DETERMINED TO BE THE CONTENTS OF A GSDR DL757080675Chiller · fumesFUMES LIKE SULPHUR COMING FROM FWD GALLEY FOUND. F/C FREEZER AT FAULT REPLACED.SDR SB05053Coffeemaker · odorPIT FL 591 - CREW REPORTED SMOKE IN THE AFT GALLEY THAT WAS ELECTRICAL IN NATURE. FLIGHT DIVERTED TO PIT. ON DESCENT, CREW NOTED THAT THE SMOKE ABATED. MAINTENANCE REPLACED BOTH AFT GALLEY COFFEE MAKERS, WHICH WERE REPORTED TO BE CAKED WITH A BUILD-UP OF DRSDR DL76G050241Oven · burnedON ARRIVAL F/A`S NOTICED A BURNED PLASTIC SMELL COMING FROM MID GALLEY NEAR ROW 5. REMOVED BURNT PLASTIC FROM TRAYS IN NUMBER 2 OVEN MID GALLEY. OVEN CHECKS GOOD. NO PLASTIC SMELL WHILE USING OVEN OR AFTER TURNING OVEN OFF. MCO AND PLACARD REMOVED.SDR AALA20050347Oven · inoperativeGLA INFLIGHT T0083/20APR FRA-ORD CREW REPORTED SMOKE COMING OUT FROM OVERHEAD AREA BY LT NR 1 DOOR IN FLIGHT. UTILITY BUSSES TURNED OFF AND SMOKE DISSIPATED. DIVERTED TO GLA AND OVERWEIGHT LANDING MADE WITHOUT INCIDENT. FOUND SMOKE SOURCE FROM OUTBOARD NUMBSDR AALA20050280Oven · malfunctionedGLA - EN ROUTE FRA - ORD ON FLIGHT 83 CREW REPORTED SMOKE COMING OUT OF OVERHEAD AREA BY 1L DOOR. UTILITY BUSSES TURNED OFF AND SMOKE DISSIPATED. LANDED GLA WITHOUT INCIDENT. REPLACED NUMBER 1 GALLEY OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR C2XA05BT023Odor · detectedCLE LOG SQUAWK ELECTRICAL BURNING SMELL EMINATING FROM COFFEE POT AREA. COFFEE POT BREWER OPS CHECK GOOD IAW EMB145 CMM 25-30-39.SDR 2005UALA00472Receptacle · failedAFT VACUUM CB OUT. FA REPORTED SPARKS IN GALLEY POPPED. FAILED RECEPTACLE NOT RECOVERED. AMT SAYS FOUND IT IN TWO PIECES. CAUSE OF FAILURE MAY BE DETERIORATION OVER TIME. INCONCLUSIVE WITHOUT FAILED PART.SDR DLM90050182Oven · malfunctionedFORWARD GALLEY OVEN SMOKED WHEN TURNED ON. SMOKE DISSIPATED WHEN OVEN WAS SELECTED OFF. REPLACED OVEN.SDR DL76L050167Oven · dirtySLIGHT ELECTRICAL ODOR NOTICED IN AFT GALLEY WITH NO VISIBLE SMOKE. PULLED ALL GALLEY C/B INCLUDING AFT GALLEY LEFT AND RIGHT BREAKERS IN COCKPIT. ODOR DISSIPATED AND FLIGHT CONTINUE WITH NO FURTHER USE OF AFT GALLEY. ALSO ALL AFT GALLEY LIGHTS WERE TURNED SDR GTIA050078Support Angle · corrodedG-2 GALLEY, UPPER SECTION, LOWER EDGE AND SUPPORT ANGLE ARE CORRODED. REMOVED CORROSION ON LOWER EDGE AND SUPPORT ANGLE. FOUND SUPPORT ANGLE OUT OF LIMITS FABRICATED SUPPORT ANGLE IAW SRM. PRIMED AND INSTALLED SUPPORT ANGLE. (K)SDR GTIA050079Doubler · corrodedG-2 GALLEY, CART ENCLOSURE, AFT LOWER LIP AND (2 EA) DOUBLERS ARE CORRODED. REMOVED LOWER LIP AND DOUBLERS, FOUND LIP AND DOUBLERS OUT OF LIMITS. FABRICATED LIP CHANNEL AND DOUBLERS OUT OF LIMITS. FABRICATED LIP CHANNEL AND DOUBLERS. TREAT AND PRIMED. INSSDR DLM90050153Coffeemaker · dirtyCLEANED BURNED COFFEE FROM HOT PLATE IN AFT GALLEY DUE TO BURNING SMELL.SDR DL764050152Oven · odorF/A REPORTED A BURNING RUBBER SMELL IN THE NR 4 OVEN. CLEANED NR 4 OVEN.SDR DL764050112Coffeemaker · failedFWD GALLEY NR 1 COFFEEMAKER C/B POPPED. REPLACED COFFEEMAKER WIRING AND CONNECTOR FOR REPORTED SPARKS.SDR DLM88050102Oven · smokeF/C OVEN SMOKES EXCESSIVELY WHEN TURNED ON. REPLACED OVEN IN F/C GALLEY. OPS CHECK OK.
Back to JASC 2530