Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL73S030778Coffeemaker · burnedBURNING ODOR IN AFT GALLEY, TURNED GALLEY POWER OFF, ODOR WENT AWAY. REPLACED AFT GALLEY NR 2 COFFEE DISPENSER.SDR CALA0300420Oven · inoperativeTHE FIRST CLASS GALLEY OVEN #204 BEGAN TO PRODUCE AN ELECTRICAL ODOR WHILE IN ROUTE TO ANC. THE OVEN SHUTDOWN AUTOMATICALLY AND WOULD NOT RESET. THE FLIGHT CONTINUED TO ANC WITHOUT FURTHER INCIDENT. THE OVEN WAS PLACARDED INOPERATIVE. THE OVEN WAS REMOVED AND SDR DL757030698Coffeemaker · odorLIGHT ELECTRICAL ODOR AT 2L DOOR AND GALLEY AREA F/A'S PULLED COFFEE AND OVEN C/B'S AND ODOR DISSIPATED//INSPECTED GALLEY AND SURROUNDING AREA FOR SOURCE RESET C/B'S RAN GALLEY EQUIPMENT NO DESCREPANCIES FOUNDSDR 0301346641Coffeemaker · burnedDURING FLIGHT, A BURNING ODOR EMITTED IN THE AREA OF DOOR 4R. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE CENTER GALLEY FORWARD COFFEEMAKER. OPERATIONAL CHECK GOOD.SDR 0301356638Coffeemaker · smokeDURING FLIGHT, SMOKE EMITTED FROM THE NR 2 COFFEEMAKER. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE COFFEEMAKER. OPERATIONAL CHECK GOOD.SDR C2XA03BT075Coffeemaker · smokeCREW REPORTED, FLIGHT ATTENDANT SMELLED ELECTRICAL SMOKE FROM GALLEY LIGHT CIRCUIT BREAKER. MAINTENANCE INSPECTED COFFEE POT(S) SOCKET AND GALLEY LIGHT ASSEMBLY, NO FAULT FOUND. OPS CHECKED GOOD. AIRCRAFT RELEASED FOR SERVICE.SDR USAASB03114Coffeemaker · odorDURING CRUISE, EN ROUTE FROM DFW TO CLT, THE FLIGHT ATTENDANT REPORTED A BURING RUBBER ODOR IN THE VICINITY OF THE GALLEY COFFEE MAKERS. POWER WAS REMOVED FROM THE COFFEE MAKERS AND THE ODOR DISSIPATED. FLIGHT CONTINUED ONTO CLT AND LANDED WITHOUT FURTHER INSDR DL76L030653Odor · detectedMID GALLEY RT FWD OVEN GIVES OFF BURNING ELECTRICAL PLASTIC SMELL. REMOVED BOTH FWD RIGHT OVENS PERFORMED WIRE INSPECTION IAW S.I. 01-086645-12. NO DEFECTS NOTED REINSTALLED OVENS. OPERATED BOTH OVENS FOR 25 MIN NO BURNING ODORS NOTED. MCC NOTIFIED OK FORSDR 0301306306Oven · burnedDURING FLIGHT, A STRONG BURNING FUME EMITTED FROM THE G1B GALLEY RIGHT OVEN. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE OVEN. OPERATIONAL CHECK GOOD.SDR DL76L030613Oven · malfunctionedGALLEY FIRST CLASS CENTER OVEN OVERHEATS WHEN COOKING HAS A ELECTRICAL ODOR. OVEN INOP. PULLED AND SECURED C/B FWD TO MCO AND PLACARD IAW MEL 25-20-01I. ETOPS CATEGORY 'F': ANY OTHER EVENT DETRIMENTAL TO ETOPS.SDR DL73G030584Coffeemaker · sparksCOFFEEMAKER HAS ELECTRICAL SPARKS. REPLACED DISPENSER.SDR DLM88030574Coffeemaker · odorPRIOR TO LANDING ATTENDANTS REPORTED BURNING RUBBER ODOR IN FWD GALLEY/FC AREA. ATTENDANTS TURNED EVERYTHING OFF AND GALLEY POWER WAS REMOVED. JUST BEFORE LANDING SMOKE STARTED COMING FROM 1ST CLASS COFFEEMAKER, HALON FIRE EXTINGUISHER DISCHARGED. REPLACED SDR DL76G030572Odor · detectedMID GALLEY BUN WARMER OVERHEATED WITH STRONG ELECTRICAL SMELL. INSPECTED BUN WARMER, FOUND VERY HOT TO TOUCH, PULLED AND SECURED C/B AND FORWARD TO MCO AND PLACARD PER MEL 25-20-01B.SDR DL733030553Coffeemaker · leakingELEC ODOR COMING FROM FWD GALLEY COFFEEMAKER UNIT WAS TURNED OFF AND CB'S OPENED ODOR WENT AWAY. REMOVED COFFEEMAKER FOR INSPECTION FOUND WATER LEAK AT WATER SUPPLY TO HEATING TANK SECURED B-NUT DRIED ENTIRE DISPENSER CAVITY REINSTALLED BREWED TWICE THROUSDR S03J25023Coffeemaker · odorWHITE SMOKE AND BURNING ODOR COMING FROM GALLY HOT POT AREA. HOT POT REMOVED AND ALL CB IN GALLY PULLED, SMOKE DISAPPEARED IMMEDIATELY. GROUND CHECK FOUND HOT POT MALFUNCTION GOT WHITE SMOKE AND BURNING ODOR. INFORM CPCS TO REPLACE HOT POT AND FOR MAINT PRESDR AMTA200300733Oven · malfunctionedOVEN GLIDES IN FORWARD AND AFT GALLEY CREATE BILLOWING CLOUDS OF SOOT AND BLACK SMOKE WHEN COOKING ENTREE'S, AS REPORTED BY SR F/A. CATERING REMOVED AND REPLACED INSERTS AND GUIDES. OVENS IN FORWARD AND AFT GALLEY, OP CHECKED GOOD AMM 25-00-00. (M)SDR 0300976312Oven · smokeDURING FLIGHT SMOKE EMITTED FROM THE 3-28 OVEN IN THE NR 4 GALLEY. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE OVEN AND CONTROLLER. OPERATIONAL CHECK GOOD.SDR 0300986302Controller · failedDURING FLIGHT A ELECTRICAL ODOR WAS NOTICED AT THE TOP OF THE STAIRS LEADING TO THE UPPER DECK AND IN THE MAIN CABIN BY THE VIDEO CONTROLS. TURNED OFF GALLEY POWER AND VCR'S. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED 2-33/34 OVSDR AALA20030492Oven · inoperativeFLIGHT ATTENDANTS REPORTED SMOKE AND A BURNING SMELL FROM FORWARD GALLEY OVEN. RETURNED AND LANDED JFK WITHOUT INCIDENT. REMOVED DEBRIS FROM FIRT CLASS OVEN. SYTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DL76G030355Coffeemaker · odorAT DEPARTURE F/A INFORMED OF A SMOKE ODOR AT AFT RT GALLEY COFFEEMAKER AREA. REMOVED NR 1 AND NR 2 COFFEEMAKER AND FOUND WIRES OK. NOTICE AN ODOR AT NR 2 COFFEE MAKER. REPLACED NR 1 AND 2 COFFEEMAKERS IN AFT RT GALLEY. OPS OK.SDR DL757030354Oven · odorPER CREW OVEN BURNING ODOR ON TAKEOFF AND CLIMB IN COCKPIT AND CABIN, ALL OVEN CBS PULLED CABIN ODOR STOPPED.THIS WAS ON FLT 1241 FROM ATL TO BWI. REMOVED AND REPLACED OVENSSDR SWAA030836Coffeemaker · overheatedDURING APPROACH, F/A SMELLED BURING ODOR IN AFT GALLEY. FOUND NR 1 COFFEEMAKER CIRCUIT BREAKER TRIPPED. REMOVED AND REPLACED NR 1 COFFEEMAKER PER MM.SDR DL738030329Oven · shortedAFTER TAKEOFF AIRCRAFT FILLED WITH BURNING ODOR NR 1 OVEN IN AFT GALLEY WAS EXTREMELY HOT EVEN THOUGH OVEN WAS NOT IN USE PULLED C/B AND IT SLOWLY COOLED OFF AFTER 30-40 MIN. REPLACED OVEN.SDR 0300676312Controller · inoperativeDURING FLIGHT SMOKE EMITTED FROM THE NR1 OVEN IN THE UPPER DECK. PULLED GALLEY CIRCUIT BREAKER, AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE OVEN CONTROLLER, OPERATIONAL CHECK GOOD.SDR 0300666313Oven · smokeDURING FLIGHT SMOKE EMITTED FROM THE NR 2 GALLEY OVEN, POSITION 2-34. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE OVEN, OPERATIONAL CHECK GOOD.SDR DL777030299Coffeemaker · sparksCOFFEEMAKER AT 205 SPARKING TURNED OFF PWR PULLED C/B. REPLACED COFFEEMAKER.SDR C2XA03CL078Coffeemaker · shortedLGA FLIGHT 2827 THE CREW REPORTED A ELECTRICAL ODOR COMING FROM THE COFFEEMAKER. MAINTENANCE REPLACED THE NR 1 COFFEEMAKER. OPERATIONAL CHECKS WERE GOOD.SDR C2XA03CL077Coffeemaker · shortedCLE FLIGHT 2022 THE CREW REPORTED A INTERMITTENT SMELL OF ELECTRICAL SMOKE IN FLIGHT. MAINTENANCE INSPECTED AND REPLACED THE NR 2 COFFEEMAKER. OPERATIONAL CHECKS WERE GOOD.SDR DL76G030273Oven · dirtyF/A REPORTED MINOR SMOKE IN FWD GALLEY. PULLED C/BS. SUSPECT FOOD AS CAUSE AFTER EXAMINATION. FOUND FWD GALLEY OVEN HAS LARGE AMOUNTS OF CHOCOLATE AND CARAMEL. CLEANED OVEN. NO FURTHER SIGNS OF SMOKE DURING OPS CHECK.SDR DLM11030250Coffeemaker · odorELECTRICAL ODOR BY 4L AND R DOOR NO SMOKE OR OTHER ABNORMAL INDICATIONS. FOUND ODOR SMOKE FROM COFFEEMAKERS. REPLACED SAME.SDR 030055631Oven · smokeDuring flight smoke emitted from the #4 oven in the #3 galley. Aircraft continued to destination and landed without incident. Replaced the oven controller, operational check good.SDR DLM88030240Oven · overheatedFWD GALLEY OVEN OVERHEATS AND SMOKES. REPLACED SAME.SDR S03425013Chiller · smokeB-18275 IN FLT GALLEY UNIT 8 UPPER CELLING FOUND AIR LEAK AND SMOKE. CK ALL GALLEY 8 EQUIPMENTS FOUND AIR LEAK AND SMOKE CAME FROM CHILLER.CHILLER RPLD AND ALL GALLEY 8 EQUIPMENTS FUNCTION CHECKED NORMAL.SDR S03425011Coffeemaker · odorB-18203 IN FLT BURING ODOR CAME OUT ONCE AT GALLEY UNIT 3 AND THEN PULL OUT ALL C/B OF UNIT 3. CHECKED ALL GALLEY 3 EQUIPMENT FOUND BURNING ODOR COME FROM COFFEEMAKER 309. COFFEEMAKER 309 REPLACED AND ALL GALLEY. EQUIPMENTS FUNCTION CHK NML.SDR C2XA03IA026Coffeemaker · odorFLIGHT 2466 PASSENGER REPORTED POSSIBLE BURNING ODOR POSSIBLY CAME FROM GALLEY. ODOR WENT AWAY AFTER TURNING OFF COFFEEMAKERS. SERVICED COFFEEMAKERS WITH H2O, VERIFIED NORMAL OPERATION OF COFFEEMAKERS IAW CMM 25-30-40, NO BURNING ODOR NOTED. THE AIRCRAFT WSDR ZW0A0302801ControllerAFTER PUSH BACK THERE WAS SMOKE AND SPARKS FROM THE FORWARD GALLEY OVEN. THE AIRCRAFT RETURNED TO THE GATE. A PAPER/FOIL LID WAS TRAPPED BETWEEN THE OVEN AND FOOD CONTAINER AND LODGED AGAINST THE VENT FAN CAUSING THE FAN TO SMOLDER AND CAUSE SMOKE. THE LID WSDR RO32003F00000Ribbon Heater · failedDURING AN INSPECTION DISCOVERED MELTED GALLEY DRAIN HEAT TAPE. REMOVED THE DAMAGED HEAT TAPE AND REPLACED. AIRCRAFT WAS INSPECTED FOR PROPER INSTALLATION OF THE EXISTING HEAT TAPE AND MODIFIED AS NECESSARY TO ENSURE PROPER INSTALLATION AND CONTINUED AIRWORTHSDR DLM11030156Oven · odorGALLEY G5 OVEN HAS BURNING SMELL. REPLACED OVEN.SDR SWAA030341Coffeemaker · overheatedOVERHEAT FUME ODOR AT AFT COFFEE MAKER. FOUND, AFT COFFEE MAKER OVERHEATED AND TRIPPED C/B. REMOVED AND REPLACED COFFEE MAKER PER MM.SDR MEX2003024Socket · burnedAIRCRAFT ACCOMPLISHED AN UNSCHEDULED LANDING, SMOKE IN FORWARD GALLEY. DURING CRUISE WAS DETECTED SMOKE IN PASSENGERS CABIN FROM THE UPPER PART OF THE FORWARD GALLEY OVENS A SMOKE WAS INCREASED WHEN THE SYSTEM WAS SHUTOFF. OVEN NR 2 WAS CHECKED BY CONDITION SDR CALA0300022Oven · inoperativeTHE AIRCRAFT WAS RETURNED TO LAX AFTER SMOKE WAS REPORTED IN THE AFT GALLEY. THE AIRCRAFT LANDED SAFELY AT LAX WITHOUT INCIDENT. MAINTENANCE FOUND THE AFT GALLEY RIGHT OVEN VERY HOT TO THE TOUCH AND THE COMPARTMENT ABOVE THE OVEN WAS ALSO VERY HOT. MAINTENASDR DL76K030124Coffeemaker · dirtyAFT GALLEY HAD ELECTRICAL TYPE SMELL ON RT SIDE OF GALLEY. CHECK AFT GALLEY FOR ANY IRREGULARITIES. THE UTILITY BUSSES WERE TURNED OFF. UTILITY BUSSES RESET BY CREW. OPERATION ALL AFT GALLEY OVENS, CHILLERS COFFEEMAKERS AND LIGHTS. FOUND COFFEEPOT WITH BUSDR AALA20030122Coffeemaker · malfunctionedDFW - FLT 1607 - ON TAXI OUT DFW, NR 4 FLIGHT ATTENDANT IN REAR OF AIRCRAFT REPORTED A LOUD FLASH/BANK AND SMOKE FROM AFT GALLEY. GALLEY POWER WAS TURNED OFF AND FLIGHT ATTENDANTS REPORTED SMOKE DIMINISHED. ALSO, FLIGHT ATTENDANTS REPORTED A WHITE POWDER COVSDR DL733030081Coffeemaker · odorFLT ATTENDANT VERBAL REPORT, LT AFT GALLEY COFFEEMAKER HAS ELECTRIC ODOR. REPLACED COFFEEMAKER, OPS CHECK NORMAL. NO ODOR.SDR AUS20030072Oven · odor(AUS) SMOKE ODOR IN REAR CABIN. ODOR WAS TRACED TO REAR GALLEY OVEN.SDR 0300106313Coffeemaker · odorDURING FLIGHT A STRONG BURNING ODOR EMITTED IN THE AREA OF THE NR 5 GALLEY. PULLED THE GALLEY CIRCUIT BREAKERS AND THE AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. CLEANED AREA OF COFFEEMAKERS. OPERATIONAL CHECK GOOD.SDR DL76L030064Oven · faultyINBOUND OVEN ON FIRST OFFICERS SIDE IN AFT GALLEY WAS ON FIRE AND FLAMES WAS SHOOTING OUT FROM GRILL ABOVE THE OVEN. FLT ATTENDANTS TURNED OFF OVEN AND FLAMES STOPPED. CIRCUIT BREAKERS WERE PULLED LATER. FOUND NR 4 OVEN POWER WIRES BURNED. REMOVED AND REPLSDR SWIA200311715Door · stuckCANNOT GAIN ACCESS TO LAVATORY FIRE EXTINGUISHER BOTTLE, PANEL STUCK. REPLACED DOOR WITH A SERVICEABLE UNIT. OPS CHECK GOOD. P/N: 4582073-501SDR C2XA03BT005Coffeemaker · faultyCLE---CO2162, CREW REPORTED, " STRONG BURNING SMELL IN GALLEY WITH AND WITHOUT GALLEY POWER ON." INSPECTED AND REPLACED HOT JUG AS REQUIRED. (OPS.CHECKED NO BURNING SMELL NOTED, AIRCRAFT RETURNED TO SERVICE.)SDR DLM88030020Coffeemaker · overheatedON ENTRY INTO AIRCRAFT FIRST OFFICER AND FLIGHT ATTENDENT SMELLED ELECTRICAL TYPE ODOR IN AIRCRAFT. FOUND R1 GALLEY COFFEEMAKER OVERHEATING. REPLACED.
Back to JASC 2530