SDR DL76L030009Coffeemaker · odorGALLEY 1R FWD OF DOOR COFFEEMAKER CB POPPED. BURNING ODOR. CONTINUED ON MCO. NO PARTS ATL. MEL 25-20-01D.SDR 0300026305Motor · burnedDuring flight a flight attendant reported an electrical fume odor coming from galley elevator when in overide position. Aircraft continued to destination and landed without incident. Replaced elevator motor actuator. Operational check good.SDR QXEA0300004Coffeemaker · malfunctionedSEA ON FLIGHT 2170- BURNING SMELL EXPERIENCED IN GALLEY IN THE COFFEE WARMER AREA. REMOVED AND REPLACED NR 1 AND 2 COFFEE JUGS. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR S02425050Coffeemaker · failedB-18205 LIGHT SMOKE FROM COFFEE MAKER IN GALLEY 3 C/B PULLED SYS ISOL. INSPECT C/B PANEL AND COFFEE MAKER CONNECTOR WIRING CONDITION IS NML. REPLACE 809B COFFEE MAKER AND FUNCTION CK NML. SIT WAS FILLED FOR THE OFF COFFEE MAKER.SDR CALA0200587Oven · malfunctionedFLIGHT ATTENDANTS REPORTED SMOKE COMING FROM BEHIND OVENS IN AFT GALLEY WHILE AT CRUISE EN ROUTE TO CLE. ASSOCIATED CIRCUIT BREAKERS WERE PULLED AND THE SMOKE CEASED. THE FLIGHT WAS CONTINUED TO CLE WHERE IT LANDED WITHOUT FURTHER PROBLEM. MAINTENANCE FOUNDSDR CA021227002Coffeemaker · odor(CAN) A/C ARRIVED ON A TURN AROUND AT YYZ. CREW INFORMED MTCE THAT THEY SMELLED SOMETHING BURNING IN THE AFT GALLEY. MTCE ISOLATED THE ODOR TO THE AFT LT GALLEY UNIT, NR 1 & 2 COFFEEMAKERS. THE COFFEEMAKERS WERE REMOVED FOR INSPECTION. MTCE FOUND THAT THE SHELSDR C2XA02CL246Connector · burnedTHE CREW REPORTED A BURNING SMELL COMING FROM THE LEFT HOT JUG IN THE GALLEY. MAINTENANCE INSPECTED AND REPLACED THE LEFT HOT JUG CONNECTOR AND HOT JUG. OPERATIONAL CHECKS WERE GOOD.SDR DL757021419Oven · malfunctionedON LAYOVER FOUND MID GALLEY AFT RT OVEN PRODUCING SMOKE AND HEAT FROM THE CONTROLLER AREA. PULLED CIRCUIT BREAKER. REPLACED OVEN AND RT CAVITY CIRCUIT BREAKER.SDR U30A200200030Oven · sparksDuring Cruise on Flt 256 EWR - PUJ, the Flight Attendant reported a spark coming out of aft center oven. Flt crew turned oven of and pulled circuit breaker immediatley. On ground at PUJ, Maintenance performed an operational check I/A/W AMM 25-35-00-501 with noSDR CA021119001Cable · broken(CAN) THE AIRCRAFT EXPERIENCED AN IN FLIGHT LOSS OF IT'S SLING LOAD. INVESTIGATION REVEALED THAT THE SWAGED END OF THE EMERGENCY RELEASE CABLE HAD COMPLETELY SEPARATED FROM THE CABLE CONDUIT. THIS PLACED THE CABLE CONSTANTLY UNDER PRELOAD .THE RESULT BEING THSDR YENA200229Coffeemaker · odorFLT 187, JFK TO MCO, SMELLED SMOKE, NONE VISIBLE, FLIGHT ATTENDANT REPORTED 2 FWD COFFEEMAKERS BREAKERS POPPED. RETURNED TO JFK, REMOVED AND REPLACED COFFEEMAKER, PERFORMED GENERAL VISUAL INSPECTION OF AREA BEHIND COFFEEMAKERS AND REMOVED FWD GALLEY ELECTRICALSDR DL757021329Coffeemaker · malfunctionedAT FLT LVL 270 FROM ATL TO BWI FLT ATTN REPORTED WHITE/GRAYISH SMOKE COMING FROM THE AFT GALLEY ABOVE THE CEILING PANEL. REMOVED GALLEY POWER, SMOKE STILL EVIDENT. DECLARED EMERGENCY INTO CLT. DISCOVERED THE AFT GALLEY LEFT COFFEE MAKER HAS BURNED HEATING ESDR C2XA02BT074Socket · burnedCREW REPORTED, BURNING ODOR BY GALLEY AREA FOLLOWING LANDING, SMELLS LIKE BURNED POPCORN. MAINTENANCE REMOVED AND REPLACED NR 2 COFFEEMAKER SOCKET IAW EMB145 AMM 25-31-01 AND NR 2 COFFEEMAKER IAW EMB AMM 25-31-01. OPS.CHECKED GOOD. NO ODOR NOTED. AIRCRAFT RESDR QXEA0201891Odor · detectedBOI-FOUL ODOR COMING FROM GALLEY AREA AND FORWARD CABIN. SMELL REPORTED AS SMELLY SOCKS OR VOMIT. DEODORIZED BY FLEET SERVICE. NO PARTS REPLACED. AIRCRAFT RETURNED TO SERVICE.SDR DL76L021247Chiller · malfunctionedAT CRUISE THERE WAS AN ELECTRICAL SMELL IN THE AFT GALLEY AND A HEAVY VIBRATION IN THE FLOOR AREA. WHEN THE CB FOR THE CHILLER THAT COOLS THE FOOD CARTS WAS PULLED THE VIBRATION STOPPED AND THE ELECTRICAL SMELL ABATED. AS PRECAUTIONARY ACTION DEACTIVATED BOTSDR CA021108002Heater · burned(CAN) WHILE TROUBLE SHOOTING SEVERAL SNAGS REGARDING PROBLEMS FOR 'NO WATER IN FORWARD GALLEY HALF WAY THROUGH FLIGHT' WATER LINE RIBBON HEATER FOR WATER LINE ABOVE NOSE WHEEL WELL FOUND BURNED AND BADLY DAMAGED.SDR DL764021217Oven · malfunctionedCIRCUIT BREAKER POPPED ON OVEN IN THE AFT GALLEY AFTER 30 MINUTES OF FLIGHT. THREE HOURS LATER THE SMOKE ALARM IN THE GALLEY WENT OFF. NO SMOKE WAS OBSERVED OR SMELLED AND THE CB HAS NOT BEEN RESET. FWD OVEN 708 TO MCO AND PLACARD PER MEL 25-20-01I. C/B'S SDR DLM11021216Oven · unserviceableOVEN 326 AFT GALLEY SPARKS CAME OUT ABOVE THE WORD OFF ON THE TIMER - REPLACED OVENSDR 29222021Coffeemaker · failedDURING BOARDING OF THE FLIGHT ROC TO IAD, CREW REPORTED SMOKE COMING FROM THE COFFEEMAKER, CFR WAS DISPATCHED AND PASSENGERS RETURNED TO GATE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE COFFEE MAKER AND AIRCRAFT WAS RELEASED FOR RETURN TO SERVICE.SDR C2XA02BT060Connector · shortedSTRONG ELECTRICAL SMELL IN GALLEY. MAINTENANCE FOUND SHORTED NUMBER ONE COFFEE POT CONNECTOR. MAINTENANCE REMOVED AND REPLACED COFFEE POT CONNECTOR AND REPLACED COFFEE POT UNIT. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR ZW0A0210502Oven · malfunctionedSTRONG ELECTRICAL SMELL WAS NOTICED IN COCKPIT AND FORWARD GALLEY. SHUT OFF GALLEY POWER AND SMELL DISSIPATED. REPLACED THE NUMBER 2 GALLEY OVEN.SDR C2XA02CL200Coffeemaker · odorCLE FLIGHT NR 3180 THE CREW REPORTED THE LT COFFEE POT WAS SMOKING AND HAD A ELECTRICAL SMELL.MAINTENANCE INSPECTED AND PLACED ON MEL 25-60-02/3.SUPPLEMENT TO FOLLOW.SDR DLM11021173Control Panel · malfunctionedOVEN NR 2 BURNING METAL ORDO FROM ELECTRICAL TOUCH PANEL AREA AROUND PANEL HOT C/B PULLED RESET C/B RAN OVEN TO 350 DEGREES FOR 20 MINUTES NO DEFECTS NOTED OK FOR SERVICESDR DL733021152Oven · malfunctionedFLT ATTENDANT REPORTED SMOKE/ELECTRICAL SMELL COMING FROM F/C GALLEY OVEN AND CONTROL PANEL. FIRE EXTINGUISHER USED. NO FIRE NOTICED. GALLEY POWER SECURED. ELECTED TO DIVERT TO LBB. REMOVED AND REPLACED OVEN, OP CKS NORMAL.SDR DL757021151Coffeemaker · shortedA/C 630 ON FLT 1107 HAD ATB TO SAV DUE TO F/C GALLEY COFFEE MAKER HAD AN ELECTRICAL SHORT AND CAUSED HAZE/SMELL IN FWD GALLEY/CABIN AREAS. CREW REPORTED NO SMOKE IN COCKPIT. RETURNED TO SAV WITHOUT INCIDENT. FOUND FWD COFFEE MAKER BAD REPLACED COFFEE MAKERSDR AALA20021332Oven · dirtyLAX - ON CLIMB-OUT FROM LAX FLIGHT ATTENDANTS REPORTED A BURNING SMELL IN THE FORWARD GALLEY SMOKE WAS THEN REPORTED RETURNED TO LAX. FOUND BAKED ON DEBRIS IN FORWARD OVEN. DEBRIS REMOVED AND OVEN CLEANED BY CABIN SERVICE. (M)SDR DLM88021118Oven · smokeCLIMBING OUT OF SAT AT APPROXIMATELY 8000 FT, FA REPORTED SMOKE COMIING FROM FWD GALLEY AC WAS LEVELED AT 14000 FT FLT CREW SHUT OFF GALLEY POWER. SMOKE DISSAPATED DIVERTED TO AUS WITHOUT INCIDENT. REMOVED F/C OVEN AND INSPECTED FOR HEAT AND OVEN WIRE HARSDR CA020916009Coffeemaker · failed(CAN) ON DECENT CREW REPORTED SMOKE IN AFT GALLEY AND LOUD POPPING SOUND, GALLEY COVERED IN WHITE DUST. NOTIFIED ATC/MAINT/DISPATCH. MTCE SUSPECTED COFFEEMAKER HOT WATER BLEW PLUG, AIRCRAFT LEFT WITH UTILITY BUSES OFF/REAR GALLEY CB'S PULLED. AREA INSPECTEDSDR CA020916008Oven · odor(CAN) FLT ATT REPORTED A BURNING SMELL IN THE REAR GALLEY NR 3 OVEN FOUND AT FAULT. CB PULLED AND COLLARED. NR 3 OVEN REPLACED PER MM AND OPERATION CHECKED SERVICEABLE.SDR 0202936633Controller · malfunctionedDURING FLIGHT, AN ELECTRICAL FUME EMITTED IN THE UPPER DECK AND FLIGHT DECK. PULLED UPPER DECK GALLEY CIRCUIT BREAKERS AND SMELL DISSIPATED. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE LEFT UPPER DECK OVEN CONTROLLER. OPERATSDR AWXA200200875Coffeemaker · shortedDURING CLIMBOUT FLIGHT CREW OBSERVED AN ELECTRICAL BURNING SMELL AND SMOKE COMING FROM FORWARD GALLEY, UPON INVESTIGATION THE F/A NOTICED ARCING AT THE NR 1 COFFEEMAKER. THE AIRCRAFT TURNED BACK TO PHX AND THE NR 1 COFFEEMAKER CIRCUIT BREAKER WAS PULLED. ARCSDR 0202916628Odor · detectedDURING FLIGHT, AN ELECTRICAL BURNING SMELL EMITTED FROM THE NR 1 HOT PLATE IN THE NR 1 GALLEY. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. RECYCLED CIRCUIT BREAKER. OPERATIONAL CHECK GOOD.SDR PCAA0209101Receptacle · shortedROC-LGA FLIGHT 3905. CREW REPORTED DURING DESCENT NOTICED A SMOKE ODOR IN COCKPIT AND GALLEY AREA. MAINTENANCE INSPECTED AND FOUND NR 2 HOT JUG RECEPTACLE SHORTED OUT. RECEPTACLE AND HOT JUG REPLACED. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR DL76G021016Coffeemaker · dirtyELECTRICAL SMELL IN FWD GALLEY. COULD NOT LOCATE. OPERATED ALL FWD GALLEY AND IFE EQUIPMENT, NO ELECTRICAL ODOR NOTED. ALSO CHECKED ALL LIGHTING IN FWD CABIN. ALL CHECKED GOOD. FOUND EVIDENCE OF BURNED COFFEE. CLEANED SAME, OK FOR SERVICE.SDR ABXA020150Bracket · defectiveHOT CUP CAUSED A BURNING ODOR AND SMOKE FROM PRONGS ON THE HOT CUP. REPLACED HOT CUP AND BRACKET ASSEMBLY. OPS CHECKED GOOD IAW DC-8 MM.SDR 0202771221CoffeemakerENROUTE FROM AMS TO MIA, CREW USED HALON EXTINGUISHER INTO FORWARD GALLEY NBR 1 GALLEY COFFEEMAKER. SMOKE DIMINISHED. FLIGHT DIVERTED TO SNN AND LANDED WITHOUT INCIDENT. REPLACED COFFEEMAKER. OPERATIONAL CHECK GOOD.SDR CA020820009Tube · cracked(CAN) CREW REPORTED AFT CABIN BURNING ODOR WITH WHITE SMOKE NEAR AFT GALLEY LT CABIN DOOR AREA. THE AFT GALLEY POWER WAS TURNED OFF IN FLIGHT BY CREW AND THE SITUATION WAS BACK TO NORMAL. UPON ARRIVAL, AFT GALLEY CHILLER WAS REPLACED. THE EVAPORATOR WAS RSDR C2XA02BT042Heater · dirtyBWI---CO3404, CREW REPORTED, ELECTRICAL BURNING ODOR IN GALLEY AREA. MAINTENANCE INSPECTED GALLEY AND FIRST THREE ROWS OF THE CABIN AFT OF THE GALLEY AND FOUND BURNT COFFEE ON COFFEEMAKER HEAT PAD. CLEANED HEAT PAD, NO FURTHER MAINTENANCE REQUIRED. AIRCRAFTSDR AWXA200200751Oven · smokePHX - SMOKE - FLT 0504 - BOTH OVENS IN FORWARD GALLEY SMOKE WHEN OVEN IS HEATED. REMOVED AND REPLACED BOTH OVENS IN THE FORWARD GALLEY, OPERATIONALLY CHECKED GOOD.SDR 0202726311Coffeemaker · burnedDURING FLIGHT, SMOKE EMITTED FROM THE NR 3 GALLEY COFFEEMAKER. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. FOUND WIRE BURNT AT BOTTOM OF COFFEEMAKER. REPLACED THE COFFEEMAKER. OPERATIONAL CHECK GOOD.SDR C2XA02CL171Receptacle · meltedCLE FLIGHT# 2950 THE CREW REPORTED A STRONG BURNING RUBBER ODOR NEAR THE FRONT OF THE AIRCRAFT.MAINTENANCE INSPECTED AND REPLACED THE LEFT HAND HOT JUG RECEPTACLE.OPERATIONAL CHECKS WERE GOOD.SDR 0202606637Coffeemaker · malfunctionedDURING CRUISE, A BURNING SMELL EMITTED NEAR THE NR 3 GALLEY. DEACTIVATED THE NR 3 GALLEY, GASPER FAN AND RECIRCULATION FAN AND THE SMELL DISSIPATED. DECLARED AN EMERGENCY AND THE AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE LESDR AUS20021000Coffeemaker · faulty(AUS) COFFEEMAKER FAILED. SMOKE AND FUMES EMANATING FROM COFFEE MAKER.SDR GTIA020886Coffeemaker · malfunctionedDTW - FLT 313 - FOUND FORWARD GALLEY-LOW POT SMELLED SMOKE, SMELLED LIKE PLASTIC BURNING. PULLED C/B'S AND TURNED OFF GALLEY POWER SMELL STOPPED. REMOVED AND REPLACED FORWARD GALLEY LOWER COFFEE MAKER. OPS CHECK OK. (M)SDR SWAA021805Coffeemaker · malfunctionedSMOKE COMING FROM AFT GALLEY COFFEEMAKER. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR DLM11020927Odor · detectedFLT ATTENDANTS SMELLED AN ODOR IN AFT GALLEY CHILLER CONTROL PANEL. TURNED OFF ALL THREE CHILLER SWITCHES AND SMELL WENT AWAY. SMELL DID NOT SEEM TO BE ELECTRICAL. UNABLE TO FAULT ANYTHING IN AFT GALLEY AREA.SDR C2XA02CL162Receptacle · burnedSLP - FLIGHT 4153, THE CREW REPORTED A STRONG SMELL OF BURNING RUBBER FROM THE NR 2 COFFEE JUG. THE AIRCRAFT WAS RELEASED IAW 25-60-02/3D. MAINTENANCE REPLACED THE COFFEE POT RECEPTACLE IN THE GALLEY. OPERATIONAL CHECKS WERE GOOD. THE AIRCRAFT WAS RELEASESDR DLM11020850Coffeemaker · malfunctionedDURING TAXI OUT, F/A REPORTS HEARING LOUD POP AND SEEING SPARKS FLY OUT OF COFFEEMAKERS IN AFT GALLEY. F/A`S REPORT SMELLING ELECTRICAL SMOKE. INSPECTED COFFEEMAKERS AND COMPARTMENT WIRING, NO TROUBLE FOUND OR EVIDENCE OF ELECTRICAL ARCING. REPLACED AFT GALSDR SWAA021534Coffeemaker · faultyAFT GALLEY COFFEEMAKER ARCHING AND BURNING ELECTRICAL SMELL WAS NOTED. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR 0202266624Oven · malfunctionedDURING CLIMB, A BURNING ODOR EMITTED IN ZONE-A, ZONE-B AND UPPER DECK. SHUT OFF UPPER DECK OVENS AND PULLED CIRCUIT BREAKERS AND THE ODOR DISSIPATED. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED BOTH OVENS IN THE UPPER DECK GALLEY
Back to JASC 2530