Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025102010271Oven · smokeOVEN SMOKING, NEEDS CLEANING COACH CLASS CABIN WHITE SMOKE BRIEFLY SMELLED LIKE FOOD. FAN BLACK.ENDED W OVEN OF F OVEN WITH INTENSIVE SMOKE WHEN OPERATES, TX AS PER NEF2520AV. C/B COLLAR APPLIED. REF NEF 2520AV OVEN WITH INTENSIVE SMOKE WHEN OPERATES, TX AS PESDR CALA2025102010267Oven · dirtyOVEN SMELLS BAD G2 GALLEY OVEN 205 DEBRIEFED CABIN CREW TO DETERMINE SOURCE OF ODOR IAW AMM 05-51-26. CREW REPORTED ODOR FROM OVEN 205 ONLY. SMELLED OF SPOILED FOOD. NO SMOKE ODOR, ONLY SPOILED FOOD. OVEN WAS NOT USED DURING FLIGHT. CABIN CREW COMPLETED QUESTISDR CALA2025102010265Oven · dirtyOVEN 205 SMELLS LIKE ROTTEN FISH. CLEANED OVEN OK TO CONTINUE.SDR CALA2025102010257Oven · odorOVEN711 MAKES AN ELECTRICAL FIRE LIKE SMELL RESET C/ B NO HELP REQUESTING DEFERA. COMPLIED WITH NEF 2500BR. NOC DESK: B787 NAME: MCKEEVER DATE: 16-OCT-25- OK TO DEFER GALLEY OVEN 711 PER NEF. CONFIRMED OVEN SOURCE OF SMELL. OVEN 711 PLACED ON DEFERAL.SDR CALA2025102010256Chiller · odorFORWARD GALLEY CHILLER NUMBER 1 WHEN ON MAKES A LOUD NOISE/ELEC ODOR NO. 1 CHILLER OPERATE WILL CAUSE BIG VIBRATION, NO TIME TO FIX, CB COLLARED AND INOP STICKER INSTALLED, AFFECT FOOD CART 112,113,114,115,116, NO ELECTRICAL ODOR, REQUEST PUT NO.1 CHILLER INOPSDR CALA2025102010254Oven · smokeOVEN SMOKING OR SPARKING G9B GALLEY HALF CARRIER BOX 938R OVEN 606 SMOKING WHEN ON. OVEN 606 HAS STRONG SMELL OF BURNED FOOD. OVEN NEEDS DEEP CLEAN OR REPLACEMENT. DEFERRED OVEN 606 AS PER NEF 2520AV. M PROC C/W. REMOVED AND REPLACED 606 OVEN PER AMM 25-32-SDR DALA2025102007639Structure · damagedFOUND AFT GALLEY LAMINATE COSMETICALLY DAMAGED. R & R AFT GALLEY HAND SANITIZER LAMINATE PER A319 AMM 25-31. (1260239).SDR DALA2025102007638Structure · damagedFOUND FWD GALLEY LAMINATE COSMETICALLY DAMAGED. R & R FWD GALLEY HAND SANITIZER MOUNT LAMINATE PER A319 AMM 25-31. (1260236).SDR CALA2025101710211Oven · odorFRONT GALLEY OVEN 204 TURND OFF DUE TO SMOKE AND ODOR. REPLACED GALLEY OVEN WITH SERVICEABLE ONE IAW AMM 25-34-00. OPS CHECKED GOOD, NO SMOKE PRESENT.SDR CALA2025101309949Oven · smokeAFT GALLEY OVEN 709 HAD WHITE SMOKE OUT OF THE TOP VENTS..TURNED OFF SMOKE REPORT FORM COMPLETED AND SENT TO TOMC.TOMC APPROVAL REQUIRED TO DEFER OVEN 709. TOMC APPROVES NEF 2520AV OVEN 709 DEFERRED PER NEF 2520AV, M-PROCEDURE PERFORMED, PLACARD INSTALLED.SDR AALA202510167085Oven · odorAIRCRAFT WAS NOT GROUNDED: #1 OVEN HAS A STRONG ELECTRICAL SMELL WHEN ON. REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-35-19.SDR DALA2025101407498Retainer · corrodedSHIP 3124 G5 GALLEY HAS DELAMINATION REPORTED IN TROLLEY RETAINER BLOCK COMPARTMENT 510, 511, AND 512 ON EMPOWER NR 327, 328, AND 329. CORRECTIVE ACTION: REPLACED PER ERA 629680-14. (1249884)SDR AALA202510140957Coffeemaker · sparksAIRCRAFT WAS NOT GROUNDED: SPARKS OBSERVED COMING OUT OF AFT GALLEY #4 COFFEE MAKER, CIRCUIT BREAKER TO #4 COFFEE MAKER WAS PULLED. NO FURTHER ISSUES OBSERVED AFTER PULLING CIRCUIT BREAKER. MAINTENANCE REPLACED THE COFFEMAKER AND ACCOMPLISHED A SATISFACTORY OPSDR CALA2025101309926Oven · odorBURNT SMELL IN FWD GALLEY UPON ENTERING A/C. FLIGHT CREW BRIEFED ODOR/SMELL NEAR DOOR 1R. NO APU IN OPERATION. FAINT SMELL EXISTED, BUT NOT HEAVY. RECIRC FANS WERE ON. OPENED EE COMPARTMENT, SAME ODOR EXISTED, COULDNT FIND ANYTHING NOTICEABLE. CREW STARTED APUSDR SWAA2025101323356Coffeemaker · burnedFLT ATT. REPORTED BURNING SMELL FROM FWD COFFEE POT WITH POWER ON AND WARMER OFF. REPLACED FWD COFFEE MAKER IAW AMM 25-30-01; OPS/LEAK CHECKS GOODSDR DALA2025101507544Coffeemaker · faultedMID GALLEY COFFEE MAKER CIRCUIT BREAKER TRIPPED MID FLIGHT. F/A SAW A FLASH AND BRIEFLY SMELLED AN ELECTRICAL ODOR. C/B WAS NOT RESET. GALLEY 404 COFFEE MAKER G2A33A. C/B # GAIN 3 15A. R & R MID GALLEY COFFEE MAKER LOC G2A33A PER A350 AMM 25-36-51. OPS CK GOODSDR DALA2025100907367Structure · damagedFOUND AFT GALLEY LAMINATE COSMETICALLY DAMAGED. R/R AFT GALLEY LAMINATE PER A319 AMM 25-31. (1240901).SDR CALA2025100909845Oven · contaminatedCREW REPORTED, ON APPROACH THE SMELL OF BURNING RUBBER FOR ABOUT 5 MINS. SMELL WENT AWAY AFTER LANDING. RAN BOTH ENGINES IAW AMM 71-00-00 AND SUPPLIED PACKS WITH ENGINE BLEED, NO SMELL NOTED. RAN PACKS FOR HOURS WITH APU BLEED AND NO SMELL NOTED, ACCOMPLISSDR DALA2025100807336Structure · damagedSHIP 3130 FOUND FWD GALLEY LAMINATE COSMETICALLY DAMAGED. CORRECTIVE ACTION: R/R FWD GALLEY LAMINATE PER A319 AMM 25-31. (1240898).SDR DALA2025100607269Structure · damagedFOUND LAMINATE DAMAGED IN AFT GALLEY. REPLACED LAMINATE IN AFT GALLEY PER A319 AMM 25-31. (1237070).SDR DALA2025100607275Structure · delaminatedSHIP 3145 FOUND LAMINATE DAMAGED IN FWD GALLEY. CORRECTIVE ACTION: REPLACED LAMINATE PER A319 AMM 25-31. (1237068).SDR CALA2025100809806Oven · smokeOVEN 707 STARTS SMOKING WHEN TURNED ON CONFIRMED FOOD RESIDUE PRESENT BEHIND HEAT SHIELD AND FAN AREA. CREW CONFIRM NO ACRID SMELL BUT SMELL OF BURNT FOOD. NO TIME TO REPLACE OVEN, MEL APPLIED. REMOVED AND REPLACED OVEN 707. OPS CHECK GOOD IAW AMM 25-32-02-40SDR DALA2025101407495Retainer · corrodedSHIP 3124 BUFFET AND GALLEY G5 GALLEY CORROSION. CORRECTIVE ACTION: REPLACEMENT OF ALL TROLLEY RETAINER BLOCKS ( COMPARTMENTS 510, 511, AND 512) OF G5 GALLEY PER ER/A 629680-14. (1232453)SDR CALA2025100209523Oven · odorOVEN 204 EMMITS STRONG BURNING SMELL, CLEANED OVEN AND PEFORMED OPS CHKD GOOD.SDR DALA2025100107142Structure · damagedFWD GALLEY LAMINATE IS COSMETICALLY DAMAGED. REPLACED FWD GALLEY LAMINATE PER A319 AMM 25-31. (1228214).SDR YENA2025100100987Coffeemaker · odorFLT#451, BOS-MCO. LEVELING OFF AT FL 300 INFLT CALLED AND SAID THEY HAD SMELLED A SMOKEY ODOR. THEY SHUT OFF THE COFFEE MAKERS AND THE SMELL SEEMED TO DISSAPATE. WE TOLD THEM TO ALSO PULL THE GALLEY BREAKERS AS A PRECAUTION. NO ODOR WE ENCOUNTERED AFTERWARDS;SDR YENA2025093000971Coffeemaker · odorFLT#1307, BOS-BNA, ODOR EVENT ON DESCENT INTO BNA 2-3 MINUTES IN DURATION FROM APPOX 17000 TO 14000 FT COCKPIT NOTICED FOR 2 MINUTES AFT GALLEY NOTICED FOR 3 MINTUES WAS WORST IN AFT GALLEY ELECTRICAL SMELL MIST OR SMOKE VISABLE EYE IRRATION AND HEADACHE SYMPSDR DALA2025092506978Oven · sparksDIVERTED INTO ACC DUE TO SPARKS AND SMOKE FROM MID GALLEY OVEN. INSTALLED A NEW OVEN. OPS CHECKED OK.SDR CALA2025092509251Oven · dirtyOVEN 109 BLACK RESIDUE ON HEATING ELEMENT. SMOKED WHEN TURNED ON . STOPPED WHEN TURNED OFF REQUESTED NEF, DDP FOLLOWED AND CB OVEN 109 OPEN AND SECURED. DEFERRED IAW NEF 25178; CIRCUIT BREAKER OPEN AND SAFETY. REMOVED AND REPLACED OVEN AT POSITION 109 IAW AMSDR DALA2025092306949Oven · failedAIRCRAFT 1007, OVEN 104 IN FWD GALLEY WAS USED TO WARM UP BREAD FOR ONLY 5 MINUTES. STARTED TO SMELL AN ELECTRICAL BURNING SMELL, THEN THE SCREEN GAVE AN ERROR MESSAGE. SHUT OVEN 104 DOWN. CORRECTIVE ACTION: REPLACED OVEN 104 REF A321 AMM 25-35-19. OPS CHK NMLSDR AALA202509275566Oven · faultedAIRCRAFT WAS NOT GROUNDED: LEFT GALLEY OVEN BEEPING AND HOT WHEN NOT ON. COULD SMELL FROM THE FLIGHT DECK. REPLACED FIRST CLASS OVEN NUMBER 1 PER AMM 25-32-03.SDR AALA202509235566Oven · faultedAIRCRAFT WAS NOT GROUNDED: LEFT GALLEY OVEN BEEPING AND HOT WHEN NOT ON. COULD SMELL FROM THE FLIGHT DECK. (OPEN)SDR DALA2025091506786Retainer · corrodedCORROSION ON TROLLEY RETAINER BLOCK COMPARTMENTS 110 AND 111 OF GALLEY 1 AT FWD GALLEY AREA. COMPLIED WITH ER/A 628362-14. (1195648).SDR CALA2025091508906Coffeemaker · failedAFT COFFEE POT SPARKED & CAUSED SMOKE IN CABIN. FLIGHT CREW CONFIRMED SPARK & ODOR CAME FROM COFFEEMAKER 420 AFT GALLEY, ACCOMPLISHED INITIAL INSPECTION AMM 05-51-26 NO SMOKE OR ODOR PRESENT AFTER COFFEEMAKER WAS OFF. COFFEEMAKER DEACTIVATED, INOP PLACARD SDR CALA2025091508905Oven · dirtyFORWARD GALLEY OVEN 110 SMOKED WITH SPARK FROM WITH INSIDE OVEN. CLOSED DOOR AND PULLED CIRCUIT BREAKER FOR OVEN 110. NO FURTHER SPARKS AND SMOKE DISSIPATED. INSPECTED FWD GALLEY FOUND NO DEFECTS. STEAM OVEN 110 FOUND TO BE DIRTY AND COVERED WITH CARAMEL RESSDR AALA202510246095Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY LEFT OVEN SMELLS LIKE BURNING PAPER WHEN RUN. : MAINTENANCE ACCOMPLISHED INSTRUCTIONS FOR EA 368117.SDR AALA202509156095Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY LEFT OVEN SMELLS LIKE BURNING PAPER WHEN RUN. OPENSDR CALA2025091508883Oven · dirtyONDITIONAL INSPECTION REQUIRED REF CREW DEBRIEFING REFERENCE: TASK 05-51-56-940-801-C1. C/W CONDITIONAL INSPECTION IAW AMM 05-51-56. FOUND OVEN 110 COVERED IN CARAMEL RESIDUE CAUSING BURNING ODOR AND SMOKE. NO OTHER DEFECTS/FAULTS NOTED. CLEANED OVEN SURROUNSDR CALA2025091008730Power Unit · no discrepancyALL GALLEY POWER INOPERATIVE AFTER ENGINES SHUT DOWN AND PARKING BRAKES APPLIED. GALLEY POWER REINSTATED, .BPCU READ OUT C/O NO FAULTS DETECTED, GALLEY POWER STILL AVAILABLE,SDR AALA202509087379Oven · smokeAIRCRAFT WAS NOT GROUNDED: MID GALLEY OVEN #3 IS SMOKEY WHEN TURNED ON. MAINTENANCE REPLACED OVEN AND ACCOMPLISHED A SATISFACTIORY OPERATIONAL CHECK PER CMM 25-37-36.SDR AALA202509054105Galley Mat · peelingAIRCRAFT WAS NOT GROUNDED: FLOORING IN G1 PEELING UP, FA'S TRIPPING OVER IT. MAINTENANCE REPLACED FLOOR MAT AT GALLEY G1 IAW AFMM 20-25-16.SDR SCNA20250902348Coffeemaker · damagedPLACARD ON FORWARD GALLEY COFFEE MAKER IS BENT AND SHARP. SECURED FWD. GALLEY PLACARD AT COFFEE MAKER PER AMM 11-32-00SDR AALA202509025685Coffeemaker · odorAIRCRAFT WAS GROUNDED: ON APPROACH, FLIGHT ATTENDANT REPORTED AN ACRID/BURNING RUBBER SMELL TOWARD THE FRONT OF THE CABIN. THEY REPORT IT DISSIPATED AFTER ABOUT 5 MINUTES. UPON OPENING THE CABIN DOOR IT WAS PRESENT AGAIN. MAINTENANCE FOUND THE FORWARD GALLEY CSDR DALA2025090206474Structure · damagedFOUND FWD GALLEY LAMINATE COSMETICALLY DAMAGED. REPLACED LAMINATE IN FWD GALLEY PER A319 AMM 25-31. (1176012).SDR CALA2025090208343Unknown · odorREF LP 6095938 FAS REPORT FOUL ODOR STILL COMING FROM AFT GALLEY . CLEANERS PERFORMED THOROUGHLY CLEANING FOR THE WHOLE AFT GALLEY AREA. INSPECTED LAVS D AND E FOR ANY UNUSUAL SMELLS, NO BAD SMILLS NOTECED AT THIS TIME.SDR DALA2025090206469Oven · smokeSMOKE - DUE TO ODOR FROM AFT GALLEY OVEN. REPLACED AFT GALLEY OVEN. OK FOR SERVICE. (1170716)SDR ASAA2025082860506Oven · odorFA REPORTED BURNING PLASTIC SMELL IN AFT GALLEY AREA WE HAD THEM TURN ALL COMPONENTS OFF AND THE SMELL DISAPPEARED. GROUNDED - YES. REMOVED AND REPLACED AFT GALLEY OVEN REF AMM 25-32-01/401 OPS CHECKED GOOD.SDR DALA2025090406541Cart · delaminatedFWD GALLEY, GALLEY CART COMPARTMENT 111, UPPER SKIN DELAMINATED. WAS ABLE TO SECURE LAMINATION BACK INTO PLACE PER A319 AMM 25-31. (1167646).SDR CALA2025082708163Oven · odorCOCKPIT DOOR DIFFICULT OPEN AND CLOSE. CREW REPORTS NO SMOKE OR SPARKS, BUT A STRONG ODOR FROM OVEN WHILE RUNNING. REQUESTING TO PLACE FWD GALLEY OVEN #204 ON NEF 2511110AU. C/B PULLED AND COLLARD, DDP C/W. NEF 2510AU MX TO SIGN OFF FWD GALLY OVEN#204 NEF REQUSDR AALA202508283445Oven · smokeAIRCRAFT WAS NOT GROUNDED: LEFT OVEN IN FORWARD GALLEY STARTS SMOKING WHEN TURNED ON. REMOVED AND REPLACED NUMBER 1 OVEN AT FIRST CLASS GALLEY. PER AMM 25-32-00. OPERATIONAL CHECKS GOOD.
Back to JASC 2530