Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2025122253820Handle · looseFWD GALLEY RIGHT HAND SIDE DOOR ASSIST GRAB HANDLE LOOSE<[01] SECURED FWD GALLEY R/H SIDE ASSIST HANDLE REF AMM 25-21-35SDR DALA2025121909258Structure · damagedAFT GALLEY LAMINATE IS COSMETICALLY DAMAGED. REPLACED AFT GALLEY LAMINATE PER A319 AMM 25-31. (1357446).SDR DALA2025121909257Structure · damagedFWD GALLEY LAMINATE IS COSMETICALLY DAMAGED. REPLACED GALLEY LAMINATED AMM 25-31. (1357443).SDR VNAA20260125020Fitting · corrodedCORRODED FLOOR FITTING ACCESS 107, AISLE SIDE AND BEHIND ACCESS 108 ON GALLEY 1. FLOOR FITTING ACCESS 107 AISLE SIDE AND BEHIND ACCESS 108 PN, CDSP2019-7C-760 WERE REPLACED IAW CMM 25-33-21.SDR DALA2025121809205Coffeemaker · odorATB - DUE TO REPORT OF A BURNING RUBBER SMELL IN THE AFT. GALLEY. FOUND COFFEE MAKER AT POSITION A508 TO BE THE SOURCE OF THE SMELL. COFFEE MAKER ELECTRICAL CONNECTOR SHOWING SIGNS OF ARCING. DEFERRED COFFEE MAKER TO NEF. 12/18/2025 REPLACED CABLE LOOM A508 SDR AALA202512163963Oven · odorAIRCRAFT WAS NOT GROUNDED: RIGHT GALLEY OVEN HAS STRONG BURNING SMELL WHEN IN USE. REMOVED AND REPLACED GALLEY CONVECTION OVEN. PER AMM 25-32-03. OPERATIONAL CHECK GOOD NO FAULTS AT THIS TIME.SDR AALA202512162484Control Panel · shortedAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORTED ELECTRICAL SMELL IN THE CABIN AFTER LANDING. ACCOMPLISHED JOB CARD 08L00021001 FOR TROUBLESHOOTING. FOUND BURN MARKS AT FORWARD GALLEY ELECTRICAL CONTROL PANEL. REMOVED AND REPLACED GALLEY 2 OVEN ELECTRICAL CONSDR AALA202512122484Control Panel · burnedAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORTED ELECTRICAL ODOR IN THE CABIN AFTER LANDING. ACCOMPLISHED JOB CARD 08L00021001 FOR TROUBLESHOOTING. FOUND BURN MARKS AT FORWARD GALLEY ELECTRICAL CONTROL PANEL. (OPEN).SDR CALA2025121212062Coffeemaker · odorACRID SMELL AND VISIBLE SMOKE & HAZE IN AFT GALLEY /LAST 2 PAX ROW S. CHECKLISTS RAN, DIVERTED. DEBRIEFED INBOUND FLIGHT CREW. CREW NOTED HAZE IN AFT OF AIRCRAFT CABIN, AND ODOR WAS NOTABLY WORSE WHEN LT PACK SWITCH WAS PLACED IN AUTO DURING FLIGHT. REMOVEDSDR DALA2025121109055Coffeemaker · failedIN CRUISE, AFT FLT ATTS REPORTED FAINT ODOR LIKE ARM PLASTIC IN GENERAL VICINITY OF AFT GALLEY. MOST DETECTABLE IN CART STOWAGE AREA. TURNED OF TWO COFFEE MAKERS. ODOR REPORTED SLOWLY DISSIPATING BUT OCCASIONALLY DETECTABLE. FOUND AFT GALLEY COFFEE MAKER NOSDR DALA2025120908979Coffeemaker · odorAFT GALLEY PORT COFFEE MAKER EMITTING BURNT ELECTRICAL SMELLS WHEN ON. F/A TURNED OFF AND SMELL STOPPED. INSPECTED BOTH COFFEE MAKERS (508&509). NOT ABLE TO REPLICATE SMELL. COMPLETED W/C 0550-2002 NOGO ODI SMOKE AND FUMES. FWD BOTH 508 & 509 COFFEE MAKERS TOSDR BAGA2025121100004Coffeemaker · odorMOMENTRY SMELL OF SMOKE FROM AFT GALLEY COFFEE POT. FA REPORTED SMELL WENT AWAY AFTER COFFEE MAKER 2 IN AFT GALLEY WAS SHUT OFF AT THE CMS. REMOVED COFFEE MAKER. FOUND NO EVIDENCE OF BURNS. REINSTALLED COFFEE MAKER. NO EMERGENCY DECLARED, AND NO PAX OR CREW RSDR SCNA20251208467Oven · smokeAFT GALLEY NR 1 OVEN SMOKES WHEN IN USE. R & R AFT GALLEY NR 1 OVEN WITH NEW IAW AMM 25-31-01, OPS CHECKED GOOD.SDR CALA2025120711821Oven · dirtyAFT OVENS 411 AND 412 PRODUCED EXCESSIVE SMOKE OR STEAM MID COOK ING CYCLE CONFIRMED WITH CREW, VERIFIED AFT GLLY OVENS SMOKED DUE EXCESS WATER AND PLASTIC. CLEANED 412 OK, 411 SMOKES, MEL L/P 7197105 CHECKED COFFEEMAKERS, CB'S, GLLY EQUIP ALL OK. AIRED OUT GASDR CALA2025120511782Chiller · odorFWD CHILLER HAD AN ODOR OF MELTED PLASTIC. FA TURNED OFF. DEFERRED PER MEL, PULLED AND COLLARED CB, INSTALLED INOP STICKER ADJ TO CB. REMOVED AND REPLACED THE FWD GALLEY AIR CHILLER IAW AMM 25-34-51. OPS CHECKED GOOD.SDR CALA2025120311723Warmer · odorAFT GALLEY COFFEEMAKER 516 GIVES OFF ODOR SIMILAR TO BURNING RUBBER. SWITCHED OFF COFFEEMAKER. CONFIRMED WITH CREW HOTPLATE 516 IN AFT GALLEY WAS CAUSE OF THE ODOR. PER FA'S THERE WAS NO SMOKE, ODOR STOPPED WHEN HOTPLATE 516 WAS SWITCHED OFF. MAINT CHECKESDR SWAA2025120140053Coffeemaker · odorACRID SMELL IN AFT GALLEY. SUSPECT AFT RIGHT COFFEEMAKER. FLT ATTENDANTS COULD NOT TURN IT OFF. TURNED OFF GALLEY POWER. SMELL DISSIPATED. OK TO CONTINUE IAW MEL 25-10-01 SP 1B & SP 2. PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION IAW AMM 05-51-5SDR SWAA2025120140306Coffeemaker · odorUNKNOWN BURNING IN THE FWD GALLEY. PERFORMED INSPECTION IAW AMM 05-51-56 NO ISSUES FOUND BELIEVE COFFEE MAKER. TO BE BAD. ACFT OK FOR SERVICE.SDR HNAA2025120100828Closet · contaminatedODOR EMINATING FROM G1 CREW CLOSET BOTTOM AND GALLEY AREA. INSPECTED G1 CREW CLOSET AREA FOUND 2 PLASTIC BAGS WITH DRIED LIQUID RESIDUE. CLEANED AND SANITIZED THE AREA AS REQUIRED. A/C OK FOR SERVICE.SDR AALA202511247240Coffeemaker · odorAIRCRAFT WAS GROUNDED: REF TSI 1694940, NEED TO ACCOMPLISH J/C 26L00021001. MAINTENANCE ACCOMPLISHED J/C 26L00021001, ISOLATED SMELL TO AFT GALLEY COFFEE MAKERS, REMOVED AND REPLACED 2 EACH AFT GALLEY COFFEE MAKER,WITH NO ODERS FOUND, REF TSI 1694940.SDR AALA202511246490Coffeemaker · odorAIRCRAFT WAS GROUNDED: FAS REPORT AN INTERMITTENT HOT PLASTIC SMELL IN THE AFT GALLEY ON THE GROUND AND DURING CRUISE THROUGHOUT THE FLIGHT. SMELL IS ONLY NOTICEABLE IN THE AFT GALLEY AND NOWHERE ELSE ON THE AIRCRAFT. MAINTENANCE ACCOMPLISHED TSI BY ACCOMPLISHSDR AALA202511190754Chiller · odorAIRCRAFT WAS GROUNDED: AT CRUISE ALTITUDE FLIGHT ATTENDANTS REPORTED A BURNING SMELL COMING FROM THE AFT GALLEY CENTER METAL STORAGE BOX AREA. FLIGHT ATTENDANTS TURNED OFF THE MASTER GALLEY SWITCH AND THE SMELL WAS ELIMINATED. MAINTENANCE FOUND AFT GALLEY CHILSDR HNAA2025111900750Cart · odorODOR EMINATING FROM G1 CREW CLOSET BOTTOM. INSPECTED COAT CLOSET ELECTRICAL COMPARTMENT FOUND ALL COMPONENTS AND WIRING IN GOOD CONDITION. CLEANED GALLEY CART STORAGE. ERADICATED THE ODOR FROM GALLEY ACFT OK FOR STORAGE AT THIS TIME.SDR DALA2025111808404Mount · corrodedG2 GALLEY MOUNT FOOTING EXFOLIATED CORROSION. GALLEY SUPPORT REPLACED ON NR 186.SDR QXEA2025111400343Oven · odorFLIGHT 2040. RAMP REPORTED AFT OVEN HOT AND HAS BURNING SMELL WHEN OFF. REMOVED FROM SERVICE. PLACED OVEN ON 300 HOUR NEF. RETURNED TO SERVICE.SDR DALA2025120308812Retainer · corrodedCORROSION ON LOWER TROLLEY RETAINER BLOCKS ON GALLEY G1 AT FWD GALLEY AREA. COMPLIED WITH ERA 630077-14 REV. ORIGINAL APPROVED DATE: 07-NOV- 25 MATCHES WITH ALL STEPS ON ERA 630077-14 REV. ORIGINAL, PRI REV0 AND PRI REV.1, IT HAS BEEN VALIDATED, PERFORMED REPSDR SCNA20251111435Oven · dirtyAFT GALLEY OVEN OVERLY DIRTY CREATTTES FUMES WHEN COOKING - CATERING NOTIFIED TO CHANGE OUT INSERSSDR AALA202511103104Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT NOTICED A PLASTIC SMELL IN FORWARD GALLEY. ACCOMPLISHE JOB CARD 09L00021001, FOUND NUMBER 2 OVEN IN FORWARD GALLEY TO BE THE SOURCE OF ODOR. REMOVED AND REPLACED NUMBER 2 OVEN. PER AMM 25-32-03.SDR CALA2025110710991Oven · odorAFT GALLEY OVEN 3 POSITI ON 425 HAS STRONG ELECTRICAL SMELL WHE N HEATING OPS CHECKED G4 GALLEY OVEN #3. OPS CHECKED GOOD. NO ELECTRICAL SMELL.SMELL ASSOCIATED WITH OVEN TRAYS BEING HEATED. REF AMM TASK 25-34-00-400-801-C4SDR DALA2025110608083Structure · damagedFOUND FWD GALLEY LAMINATE COSMETICALLY DAMAGED. R & R FWD GALLEY LAMINATE PER A319 AMM 25-31. (1289476).SDR DALA2025110608086Structure · damagedFOUND AFT GALLEY LAMINATE COSMETICALLY DAMAGED. R & R AFT GALLEY LAMINATE PER A319 AMM 25-31. (1289479).SDR AALA202511047047Coffeemaker · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORT BURNING SMELL IN AFT GALLEY. TROUBLESHOT AND FOUND AFT GALLEY UPPER COFFEE MAKER LEAKING ON HEATING PAD. REMOVE AND REPLACED AFT GALLEY UPPER COFFEE MAKER. PER AMM 25-32-00. GROUND OPERATIONAL CHECK GOOD ATTHIS TISDR VNAA20251204005Fitting · corrodedCORROSION FLOOR FITTING UNDER THE WASTE (1EA) AND AISLE SIDE (1EA) ON FWD LAVATORY. FLOOR FITTING UNDER THE WASTE (1EA) P/N: A414252-3 AND AISLE SIDE (1EA) P/N: A414251-1 ON FWD LAVATORY WERE REPLACED PER CMM 25-40-40.SDR UIEA2025110301291Oven · smokeOVEN NR 2 RIGHT GIVES A LOT OF SMOKE. OVEN OPS CHK OK IAW AMM 25-32-00</P>)SDR J7SA2025111000459Microwave Oven · faultedMICROWAVE SMOKED WHILE HEATING WET TOWEL. REPLACED THE MICROWAVE IAW G450 AMM 25-37-02. OPS CHECK GOOD.SDR DALA2025102907910Structure · damagedFOUND LAMINATE DAMAGED IN AFT GALLEY. REPLACED LAMINATE PER A319 AMM 25-31. (1276137).SDR AALA202511044245Oven · odorAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: FUMES IN THE FORWARD GALLEY AFTER TAKE OFF. AIRCRAFT AIR INTERRUPTED BACK TO AND LANDED SAFELY AT GRU. REMOVED AND REPLACED OVEN 1B. PER CMM 25-35-14. OPERATIONAL CHECKED NORMALSDR CALA2025103010729Oven · dirtyAFT GALLEY OVEN 707 HAS DEBRIS ON IT SO IT BURNS/SMOKES WHEN O N OVEN 707 REAR FAN FOUND TO BE DIRTY SUSPECT CAUSING SMELL. OVEN DEFERRED IAW MEL 2520AV. R & R STEAM OVEN 707 IAW AMM 25-32-02/401, OPS CHKD GOOD. REVERSED NEF OK TO CONTINUE.SDR CALA2025103010725Oven · dirtyAFT GALLEY OVEN 706 HAS DEBRIS ON IT SO IT BURNS/SMOKES WHEN O N OVEN 706 REAR FAN FOUND TO BE DIRTY SUSPECT CAUSING SMELL. NIL TIME TO REPLACE. OVEN DEFERRED IAW MEL 2520AV. R & R AFT GALLEY OVEN 706. NO SMOKE AND NO LEAK NOTED. OPS CKD GOOD. REVERSED NSDR HALA20251028330Coffeemaker · shortedATB, STRONG AND PRESISTENT ELEC BURNING ODOR IN FWD GALLEY. GALLEY MASTER COMMERCIAL AND GALLEY & CABIN SECURED PER QRH PROC WITH NO IMPROVEMENT. NO VISIBLE SMOKE. INSPECTED FWD GALLEY AND FOUND COFFEE MAKER POSITIONED IN F111 SHORTED. REMVOED AND REPLACED COFSDR AALA202511041848Oven · odorAIRCRAFT WAS NOT GROUNDED: BURNING PLASTIC SMELL REPORTED AFTER TAKE OFF IN THE FORWARD GALLEY AREA. ACCOMPLISHED SOF JC 78L00021001 FOUND FORWARD GALLEY OVEN 1B TO BE THE SOURCE OF BURNING PLASTIC SMELL. REMOVED AND REPLACED OVEN 1B, PER CMM 25-35-14SDR AALA202510301848Oven · contaminatedAIRCRAFT WAS NOT GROUNDED: BURNING PLASTIC SMELL REPORTED AFTER TAKE OFF IN THE FORWARD GALLEY AREA. ACCOMPLISHED SOF JC 78L00021001 FOUND FORWARD GALLEY OVEN 1B TO BE THE SOURCE OF BURNING PLASTIC SMELL. (OPEN).SDR DALA2025102707832Structure · damagedFOUND FWD GALLEY LAMINATE COSMETICALLY DAMAGED. R & R FWD GALLEY HAND SANITIZER LAMINATE PER A319 AMM 25-31. (1272551).SDR CALA2025102710606Coffeemaker · unsecureCM106 FOUND TO BE UNLOCKED AND SLIDING OFF RAIL LOCKED COFFEE MAKER. OPS CK GOOD REF AMM 25-32-01. YSDR CALA2025102710604Coffeemaker · unsecureCM419 FOUND TO BE UNLOCKED AND SLIDING OFF RAIL LOCKED COFFEE MAKER. OPS CK GOOD REF AMM 25-32-01. FLAGGED SDR FOR SAFETYSDR CALA2025102710602Coffeemaker · unsecureCM420 FOUND TO BE UNLOCKED AND SLIDING OFF RAIL LOCKED COFFEE MAKER. OPS CK GOOD REF AMM 25-32-01.SDR CALA2025102710560Oven · smokeFRONT GALLEY OVEN 204 STARTED TO SMOKE ELECTRIC PUNGENT SMELL LIGHTLY FILLED GALLEY. INSPECTED OVEN 204 AND OPS CHECKED IAW AMM 25-34-00-400-801-C4 STEP 8, COULD NOT RECREATE SMOKE OR BURNING SMELL AT THIS TIME. COULD NOT DUPLICATE ISSUES, OPS CHKD GOOD.SDR CALA2025102210416Oven · contaminatedOVEN 707 IN AFT GALLEY WAS SMOKING. OVEN 707 INSERT SOILED IN BURNED FOOD DEBRIS. OVEN REQUIRES CLEAN WHEN TIME ALLOWS. OVEN DEACTIVATED.SDR DALA2025102107699Oven · odorATB/FUME/DE- DUE TO ODOR IN THE COCKPIT. REPLACED CAPT NAV DISPLAY SCREEN AND FWD GALLEY NR 2 OVEN.SDR YENA2025102101049Coffeemaker · odorFLT#1552, RSW-HPN. "CABIN ODOR WITNESSED BY INFLIGHT CREW AT CRUISE. DIRTY SOCK PLASTIC BURNING AFT OF ROW 22 STRONGEST AFT GALLEY A.C LEFT; PERFORMED INFO NOTICE 2017-T015L. C/W APU COMPARTMENT INSPECTION NO OIL/FUEL LEAKS NOTED VISUAL OR WITH BLACK LIGHT. AP
Back to JASC 2530