Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2540' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2540' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA20110603EM029Vent · dirtyBOS - STRONG "BLUE WATER" ODOR IN COCKPIT FROM FRONT LAVATORY. IRRITATING TO EYES. MAINTENANCE REMOVED DUST AND DEBRIS FROM FORWARD LAVATORY AIR EXTRACT VENT. FOUND PLUGGED SOLID.SDR SWAA112992Circuit Breaker · faultyELECTRIC SMELL AT FL330; SMELL WENT AWAY BEFORE CIRCUIT BREAKER P18-4-C-6 WAS PULLED. RESET CIRCUIT BREAKER PER MM.SDR SIMA201036201Receptacle · fireON FLIGHT 3703 DURING DESCENT THE FLIGHT ATTENDANT REPORTED A FIRE IN THE LAVATORY TRASH RECEPTACLE AND HAD TO USE THE FIRE EXTINGUISHER TO PUT OUT FIRE. THE CAPTAIN DECLARED AN EMERGENCY AND LANDED AT ATL WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVSDR R61A20100348Bracket · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK. LEVEL 2 CORROSION WAS FOUND ON THE AFT LAV SINGLE SPLIT JOINT. MAINTENANCE REPLACED THE SINGLE SPLIT JOINT IAW EMB 170 CMM 25-42-03 AND AMM 20-10-01. P/N CDSP2200-3. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETIONSDR SIMA201010304Door · jammedON FLIGHT 4620 DURING PREFLIGHT INSPECTION THE FLIGHT ATTENDANT COULD NOT ACCESS THE DOOR TO THE LAVATORY FIRE EXTINGUISHER AS THE DOOR WAS JAMMED. LAVATORY SMOKE DETECTOR TEST PERFORMED AS REQUIRED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACSDR UALA2010031500869Control Unit · malfunctionedLEFT AFT LAV CB P11 U7 FOUND POPPED. PER FLIGHT CREW, "THAT BREAKER THAT'S OUT" IS ACTUALLY P11-U34, RIGHT AFT GALLEY. WITH D392 DISCONNECTED FROM M226 ELCU, CB DOES NOT TRIP. REPLACED ELCU M226, GALLEY POWER CHECKS NORMAL.SDR NSVA201041Socket · defectiveSTRONG ELECTRICAL BURNING SMELL COMING FROM LAV. TROUBLESHOT TO DEFECTIVE SOCKET. REMOVED AND REPLACED SOCKET.SDR UALA2009081002440Panel · damagedELECTRICAL PANEL EXPOSED IN FORWARD LAV. FOUND MOTION DETECTOR IN FWD LAV DAMAGED BY PAX. REPLACED MOTION DETECTOR AND OPS CHECKS OK.SDR UALA2009072002134Sign · inoperativeELECTRICAL PROBLEMS IN THE CABIN. FOUND AFT CABIN LAV-OCC SIGN L403 BAD. WILL NEED A NEW ONE. ALSO FOUND BROKEN GROUND WIRE HANGING LOOSE IN LAV M1284 DOOR SWITCH. REPAIRED BROKEN GROUND FOR DOOR SWITCH. RELAMPED HANDICAPPED LIGHT SWITCH S11 FOR LAV M1284SDR AALA20090610TUL01Unknown · fireFIRE REPORTED IN WATER HEATER COMPARTMENT IN M1 LAVATORY WHILE IN FLIGHT. FLIGHT CREW USED ALL WATER FIRE EXTINGUISHERS AND HALON BOTTLE TO EXTINGUISH FIRE. AIRCRAFT MADE AN UNSCHEDULED LANDING AT HALIFAX NS, CANADA. AIRCRAFT IS SCHEDULED FOR FERRY FLIGHT TO ASDR IPXA09554907Lavatory · odorINSPECTION TYPE:N/A AIRCRAFT COCKPIT HAS FOUL ODOR LIKE LAV MAY NEED SERVICE. SERVICED LAVATORY PER AMM 12-17-01-3. ODOR NO LONGER PRESENT.SDR AALA2009020201012Sign · inoperativeDFW - OVERHEAD LAVATORY OCCUPIED SIGN INOPERATIVE. REPLACED LAMP FOR LAVATORY OCCUPIED SIGN.SDR 2008UALA03631Unknown · smokeLAV COMPARTMENT DOOR DAMAGED AND LAV WASTE CONTAINER DAMAGED DUE TO SUSPECT LAV SMOKE IN LAV WASTE CONTAINER.SDR HNAA0800256Angle · corrodedCORROSION FOUND ON THE RT SIDE OF LAV, BOTTOM ANGLE. REPLACED ANGLE.SDR 31522Lavatory · burnedAIRLINES FLIGHT HAD A FIRE IN THE AFT LAVATORY. THE FLAMES WERE COMING FROM THE PAPER TOWEL/ TISSUE HOLDER. THERE IS DAMAGE TO THE COMPLETE LAVATORY ASSEMBLY. NO FURTHER INFORMATION IS AVAILABLE.SDR 22967Container · smokeDURING FLIGHT, IN THE AFT GALLEY WHEN ONE FLIGHT ATTENDANT DETECTED AN ODOR OF SMOKE, INVESTIGATED AFT LAV AND FOUND SMOKE COMING FROM THE AFT LAV WASTE BIN. FLIGHT ATTENDANT EXTINGUISHED THE FIRE USING A PORTABLE HALON EXTINGUISHER. IT WAS REPORTED THAT THESDR AMTA200800085Attach Fitting · corrodedAFT IB ATTACHMENT BLOCK CORRODED ON LAV A. REMOVED AND REPLACED ATTACHMENT BLOCK IAW 25-46-99 R1. (K)SDR NWAA080065515Lavatory · fireAIRCRAFT WAS AT GATE PRIOR TO BOARDING, THERE WAS AN ONBOARD FIRE IN LAV 3L. PILOT AND FIRST OFFICER HAD ALL OTHER CREW MEMBERS EVACUATE AIRCRAFT. 2 HALON FIRE BOTTLES WERE USED TO EXTINGUISH FIRE. FIRE AND RESCUE WAS CALLED WHEN SMOKE/FIRE WAS FIRST NOTICESDR F3LA200700383Attach Bolt · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED LWR ATTACHMENT BOLT ON INBD AFT CORNER OF LAV "A" SEVERELY CORRODED. REMOVED AND REPLACED BOLT IAW AMM 25-41-41-PB401.SDR F3LA200700405Mount Bolt · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED LAV E LOWER FLOOR MOUNT BOLTS CORRODED. REMOVED AND REPLACED CORRODED FLOOR MOUNT BOLTS IN LAV E IAW AMM 25-43-42-PB401.SDR F3LA200700382Bolt · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED LAV "D" MOUNT BOLTS CORRODED. REMOVED AND REPLACED CORRODED MOUNT BOLTS IAW AMM 25-43-41-PB401.SDR SIMA200730604Toilet · odorON CLIMB-OUT, FLIGHT ATTENDANT REPORTED FAINT ODOR OF BURNING RUBBER IN CABIN. ODOR WENT AWAY AFTER 5 MINUTES. FOUND ODOR COMING FROM LAV. FOUND LAV LEAKING. REMOVED AND REPLACED LAV TOILET UNIT IAW EMB140 AMM 38-32-01. NO LEAKS OR ODOR NOTED AT THIS TIMESDR AMTA200700169Mount · corrodedRT AFT LAV OB AFT CORNER MOUNT FITTING AND 2 EACH BLOCKS ARE CORRODED BS 952, RBL 49.5. CW EA 737-2500-00A0726, PARTS FAB IAW EA. (K) 10-26-07 REMOVED AND REPLACED MOUNT AND BLOCKS SPM 25-46-99. (M)SDR AMTA200700161Mount · corrodedRT AFT LAV OB CORNER MOUNT IS CORRODED (ON LAX) BS 952, RBL 49.5. REMOVED AND REPLACED RT AFT LAV MOUNT MM 25-00-00-8, REPLACEMENT PART FABRICATED 737-2500-01-8. (K)SDR AMTA200700159Mount · corrodedLT AFT LAV OB MOUNT CORRODED (ON LAV) BS 952, LBL 49.5. REMOVED AND REPLACED LT AFT MOUNT IAW SRM 25-46-99. REPLACEMENT MOUNT FABRICATED IAW EA 737-2500-09-A0716. (K)SDR HNAA0700056Angle · corrodedLAVATORY LOWER AFT FLOOR STRUCTURE ANGLE FOUND CORRODED. REPLACED ANGLE.SDR 2006UALA00604Toilet · malfunctionedRETURNED TO IAD DUE TO A WATER LEAK IN THE MAIN CABIN. TOILET OVERFLOWED AND WATER KEPT RUNNING UNTIL CREW CLOSED LAV WATER VALVE.SDR IXXA06SMN054SDrain Mast · pluggedDURING ROUTINE C-CHECK INSPECTION, INSTALLATION OF FWD LAV DRAIN MAST AT LWR CENTERLINE. PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 ATI DWG H74-102 REV A, EO SEMAN 2006102 DATED 01-13-06. REMOVED EXISTING DRAIN MAST IAW DC8 SRM 51-3-0. FABRICATED REPAIR DOUSDR CA060112003Insulation · burnedBURNT INSULATION BLANKET FOUND IN CARGO UNDERFLOOR AREA ON RT SIDE OF AIRCRAFT AROUND HEATED LAV WATER SERVICE PORT.SDR 2005UALA01018Switch · shortedELECTRICAL SMOKE SMELLED, WHITE SMOKE SEEN BRIEFLY IN AFT LAV. REPLACED DOOR LOCK SWITCH.SDR 05FDEA00251Seal · leakingLAVATORY, WHEN A FLASHLIGHT IS PLACED IN TRASH CAN THE INNER AND OUTER TRASH RECEPTACLE DOORS AND TRASH CAN LEAKS LIGHT. SEALED LAVATORY TRASH RECEPTACLE IAW FEDEX EA 8-2540-83964, EQUIPMENT/FURNISHINGS - LAVATORY WASTE COMPARTMENT SEALS - REPAIR.SDR 04FDEA03135Seal · damagedLAVATORY WASTE/TRASH CAN SEALS WORN (HAVE GAP). FOUND BY FEDEX QA. COMPLIED WITH EA 8-2540-83940, EQUIPMENT/FURNISHING, LAVATORY WASTE COMPARTMENT SEALS- REPAIR.SDR 04FDEA02952Lavatory · not seatedLAVATORY PAPER AND WASTE RECEPTACLE DOES NOT SEAL CORRECTLY. RESEALED LAVATORY PAPER AND WASTE RECEPTALE IAW MD10-10 SRM 51-41-01 VOL II AND EA 8-2540- 82478, SEALING OF FORWARD LAVATORY TRASH SHOUT.SDR DLM88040768Water Heater · failedAFT LT LAV SMOKE DET BEEPING IN FLT. WATER HEATER WAS VERY HOT INITIALLY OPENED DETECTOR AND DISCONNECTED BATTERY NO ODOR DETECTED. PULLED CB'S FOR AFT LT LAV MIRROR, FLUSH MOTOR AND WATER HEATER. RAN HOT WATER UNTIL COOL. AFT F/A INTERPHONE PANEL WAS WARMSDR 04FDEA01277Pan · delaminatedC/W EA 8-2540-77416 FWD LAV FLOOR PAN REPAIR. FWD LAV FLOOR PAN REPAIRED IAW EA 8-2540-77416 ON MAE TRAVLER T4/431252.SDR CA040209010Waste Tank · leaking(CAN) ON DESCENT, RT THROTTLE STUCK AT APPROXIMATELY 2 CM ABOVE IDLE POSITION. (UNABLE TO CONTROL POWER ON ENGINE) REGAINED CONTROL OF THROTTLE AT 1000 FEET ABOVE GROUND. FUNCTIONED NORMAL FOR LANDING AND TAXI. MAINTENANCE FOUND ICE BUILD UPON RT ENGINE THROTSDR MALA030581Lavatory · contaminatedFLIGHT DECK AND CABIN HAD STRONG ODOR OF ALCOHOL. COMPLAINTS FROM PAX. POST INSPECTION MAINTENANCE FOUND NO BLUE FLUID IN LAV TANK, JUST 2 GALLONS OF CLEAR ALCOHOL. MAINTENANCE DRAINED AND FLUSHED. RAN A/C WITH BLEEDS SELECTED UNTIL ODOR DISSIPATED FROM A/SDR 03332664Fan · failedDURING APPROACH OF FLT NR 7678 TO ORD FROM FSD CREW REPORTED A LAVATORY SMOKE DETECTOR SOUNDING AND SMOKE IN THE CABIN. CREW COMPLETED LAVATORY SMOKE QRH AND SMOKE DISSIPATED. NO EMERGENCY WAS DECLARED AND FLIGHT LANDED UNEVENTFULLY. THE LAVATORY FAN WAS FOUSDR 03331664Fan · failedDURING APPROACH TO FSD ON FLT NR 7654, CREW RECEIVED A LAVATORY TOILET SMOKE MESSAGE. CREW VERIFIED NO VISIBLE SMOKE IN THE LAVATORY. THE CREW COMPLETED THE ORH AND FLIGHT LANDED WITHOUT INCIDENT. THE LAVATORY FAN WAS IDENTIFIED AS THE CAUSE OF THE SMOKE ANSDR ASAA0380741Structure · crackedOKC - DURING 15K CHECK, FOUND CRACKS IN TRASH SHOOT ABOVE BOX IN RIGHT AFT LAV TRASH VANITY. REPAIRED PER SRM, ASA EA 2540-01113, AND AAR EA 10099. (M)SDR 0302081224Pan · corrodedDURING M-CHECK FOUND CORROSION ON AFT LAVATORY PAN ASSEMBLY. REPAIRED PER EA 12-196591.SDR C2XA03TY136TYSeal · corrodedTYS DURING A SCHEDULED 2C INSPECTION THE LEFT SEAL IN LAV WAS FOUND CORRODED AROUNDN NUT PLATE. MAINT R&R A NEW LEFT LAV SEAL IAW EMB 135/145 SRM 51-40-02. ALL WORK WAS ACCOMPLISHED AND WILL BE REL UPON COMPLETION OF ALL WORK.SDR GTIA030591Floor Panel · corrodedFTW - FORWARD LAVATORY VANITY WALL UNDER SINK AREA FLOOR CORRODED. REMOVED FLOOR. FABRICATED NEW FLOOR. INSTALLED NEW FLOOR. (M)SDR CALA0200513WebVERTICAL WEB CRACKED AT STA 1016 LBL 4. INSTALLED WEB AT STA 1016, LBL4 PER SRM 51-40-02.SDR CA020819009Dump Valve · leaking(CAN) FORWARD LAVATORY FLUID BYPASSED DUMP VALVE ASSEMBLY INTO DRAIN MAINIFOLD AND LEAKED INTO THE SERVICE PANEL AREA. AIRCRAFT WAS AT 32,000 FT AT A TEMP OF -17C, OAT, WHEN THE ICE SHED FROM THE FWD LAV SERVICING PANEL AND CONTACTED THE RT INBOARD WING AND HOSDR USAA020268Panel · corrodedTPA - FOUND LAVATORY PANEL CORRODED 1 INCH BY 2 INCH, STATION 1025 AFT LEFT LAV PANEL AT TANK DRAW CUT OUT. CORROSION LEVEL 2. INSTALLED TYPICAL WEB REPAIR PER SRM 51-70-13 FIG 1. (M)SDR 2002UALA01134Lavatory · leakingIMMEDIATELY AFTER TAKEOFF CREW NOTICED WATER LEAKING FROM THE AFT LAV. FLIGHT RETURNED TO SFO FOR REPAIR.SDR CA020708009Water Heater · failed(CAN) DURING THE C-08 CHECK, IT WAS DISCOVERED DURING THE OPERATIONAL TEST, THAT THE POTABLE WATER HEATERS, IN LAVATORY F, WERE MAKING THE C/B TRIP. THE 3 UNITS WERE REMOVED AND SENT TO THE AVIONICS SHOP. WHEN REMOVING THE TOP COVER OF ONE UNIT, WE FOUND A SOSDR C2XA02IA087Smoke · detectedAMA- FLIGHT 3808 ON TAKEOFF THE CREW NOTED SMOKE IN THE LAV AND RETURNED TO AMA WITHOUT INCIDENT. MAINTENANCE PERFORMED A OPERATIONAL CHECK OF THE LAV FIRE DETECTION SYSTEM AND CHECKED THE LAV FOR SMOKE, NO DEFECTS NOTED. COULD NOT DUPLICATE THE PROBLEM ANDSDR C1HA200285008Lavatory · corrodedAFT LAV RT RBL 27-48 HAS CORROSION STA 1150. BLENDED CORROSION IAW SRM 53-10-1, OUT OF LIMITS IAW 51-10-1. FABRICATED REPAIR IAW 51-40-2, 51-10-2, INSTALLED REPAIR IAW SRM 51-30-2, 51-20-4.
Back to JASC 2540