Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2540' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2540' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2002UALA00500Odor · detectedELECTRICAL SMELL COMING FROM BOTH AFT LAVS.SDR COMA0260200LavatoryFLIGHT 5091 LAVATOR SMOKE WARNING - F/A CONFIRMED SMOKE PRESENT.COULD NOT DUPLICTE. CHECKED ALL LAV SYSTEM - NO SMOKE NOTED.SDR GTIA010943Support · corrodedFTW - FORWARD LAVATORY SIDE WALL UNATTACHED AND CORRODED AT LOWER AREA. FABRICATED PART IAW SRM MD80 51-10-2. PRIOR TO LINE 1 REMOVED 2 CORRODED SUPPORTS IAW MD 80 SRM 51-30-0. INSTALLED 2 SUPPORTS IAW MD80 SR 51-30-01. (M)SDR CA010905008Sleeve · shorted(CAN) A/C 381 M FOUND DURING UNRELATED ROUTINE MAINT IN AREA. EVIDENCE OF FIRE DAMAGE CAUSED BY SHORTED LEAD AT WASTER TANK DUMP VALVE HEATER SLEEVE. FIRE TRACK WAS FOLLOWED FROM SOURCE FWD THROUGH LIGHTNING HOLE OF ADJACENT STRUCTURE, & UPWARD ALONG FRAME TO SDR C2XA01BT125Wire · chafedEWR---CO2942, CREW REPORTED BURNING SMELL COMING FROM LAV AREA. MAINTENANCE FOUND AND REPAIRED CHAFED WIRE AT LAV OVERHEAD SPEAKER IAW ATR 42 WIRING MANUAL CHAPTER 20. OPS CHECKED GOOD.SDR AUS20010709Valve · broken(AUS) FORWARD TOILET DRAIN VALVE POPPET BROKEN. INNER POPPET WASMISSING.SDR DLM90010868Seal · damagedTOILET SHROUD SEAL WAS FOUND DAMAGED. A REPLACEMENT SEAL WAS MANUFACTURED PER ER/A 401873-14AD.SDR AT0100193Plate · corrodedFOUND RIGHT LAVATORY KICK PLATE CORRODED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 51-10-3, 53-01 FIGURE 1, 51-10-2, 51-10-4, 53-30-2.SDR AALA20010968Wire · arcedORD - FLT 2370 - EN ROUTE DFW-ORD, FLIGHT ATTENDANT REPORTED SMOKE AND ARCING AT FORWARD LAVATORY. LANDED ORD WITHOUT FURTHER INCIDENT. REPAIRED DOOR LOCK SWITCH WIRING AT FORWARD. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR CALA0100399Floor Panel · corrodedAFT LAV HAS CORROSION AT FLOOR UNDER THRESHOLD PLATE AT AFT END AT MOUNT LUG FOR LAV MODULE TO FLOOR. REMOVED THRESHOLD AND CORROSION BUILD-UP, REPAIRED HONEYCOMB AND INSTALLED ONE NEW INSERT. REINSTALLED THRESHOLD PER SRM 51-10-02 PARA 11.SDR AUS20010605Valve · faulty(AUS) TOILET DRAIN VALVE FAULTY. FOUND DURING TESTING IAW ER B73-30-11.SDR AWXA0001388Fitting · corrodedLT AFT LAV AFT RETAINER BRACKET HAS CORROSION AND BLUE WATER STAIN. REPLACED LAV AFT RETAINER BRACKET IAW MM 25-41-03.SDR AT0100063Structure · corrodedFOUND LEFT AFT LAVATORY VANITY SINK CORRODED ABOVE AND BELOW SOAP DISPENSER. CUT OUT CORRODED AREA, FABRICATED AND INSTALLED REPAIR USING WELDED METHOD IAW TIMCO REO L00727 REV A.SDR F3LA200000277Fitting · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION AROUND RT. AFT LAVATORY OTBD AFT FLOOR MOUNT. MAINTENANCE FABRICATED AND REPLACED NEW FITTING PER EA 25-737-108.SDR TWAA0013305Lavatory · fireSMOKE CAME FROM THE RT LAVATORY WASTE AREA. CREW EXTINGUISHED FIRE IN WASTE BASKET USING WATER FROM THE LAVATORY. SUSPECT CAUSED BY A CIGARETTE. THE FIRE DETECTION AND EXTINGUISHING SYSTEMS HAD NOT YET ACTIVATED BUT WERE OPERATIONALLY CHECKED NORMAL. CHECKSDR AALA20000460Heater · failedORD - FLT 2374 - DURING FLIGHT, CREW REPORTED SMOKE IN FORWARD LAVATORY. PULLED CIRCUIT BREAKER AND NOTICED REDUCTION IN SMELL. LANDED ORD WITHOUT INCIDENT. REPLACED FORWARD LAVATORY WATER HEATER. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR 2000ZZZX178Toilet · mismanufacturedEXTERNALLLY SERVICEABLE TOILET ASSY P/N 9919009-1 WAS BEING CHANGED OUT. DURING PROCESS, DISCOVERED THERE WAS A RATCHETING SCREWDRIVER STUCK IN THE P/N 9914632-2 WASTE PIPE ADAPTER, AND A .3750 INCH SOCKET BETWEEN THE FLOOR AND TANK BOTTOM THAT POSSIBLY COULDSDR CA991116026Panel · leaking(CAN) PANEL FORWARD OF RIGHT ACU INTAKE FOUND DAMAGED. SUBMITTER SUSPECTED ICE BUILD-UP FROM LAVATORY SERVICE PANEL WHICH WAS LEAKING AT ONE DROP PER SECOND. LEAK REPAIRED, PANEL REPAIRED.SDR HNAA9900043Spring · brokenLAVATORY TRASH BIN DOOR WILL NOT STAY CLOSED. REPLACED BROKEN SPRING ON TRASH BIN DOOR.SDR SWAA983143Lavatory · cloggedABOUT 40 TO 50 MINUTES INTO FLIGHT, F/A NOTED AFT LAV WAS NOT FLUSHING AND BOWL WAS FILLING UP. FWD LAVATORY WAS ALREADY DEFERRED AND ON MEL. AIRCRAFT DIVERTED TO PHX AND MADE AN UNEVENTFUL LANDING. FOUND AFT LAV CLOGGED. REMOVED DEBRIS AND SERVICED PER BOESDR CALA9802143Outlet · shortedSMOKE CAME INTERMITTENTLY FROM THE SHAVER OUTLET IN LAV AT DOOR 2-L WHILE AT CRUISE. THE CIRCUITS WERE DEACTIVATED AND THE SMOKE STOPPED WITHOUT FURTHER PROBLEM. MAINTENANCE FOUND SOAP LEAKING FROM SPARE SOAP BOTTLE STORED ABOVE SHAVER OUTLET CAUSING A SHORTSDR COMA9860211Trash Bin · fireEMERGENCY LANDING DUE TO FIRE IN LAVATORY. INSPECTED LAVATORY TRASH BIN AND FIRE EXTINGUISHER, FOUND TO BE SERVICEABLE.SDR 99ZZZM473Spring · failedFORWARD VESTIBULE TRASH BIN DOOR ASSY, NEEDS CLEANED. ANGLE REPAIR, DOOR SPRINGS, ETC. REMOVED AND REPLACED SPRINGS. REPAIRED ANGLE AND CLEANED AND INSPECTED. (M)SDR VJ9800062Tube · corrodedCORROSION FOUND ON RT AFT LAV PRESSURE PLUMBING. REPLACED CORRODED SECTION OF PLUMBING IAW DC9 MM 25-41-0.SDR 98ZZZX2755Spring · brokenFORWARD LAVATORY TRASH BIN LID SPRINGS BROKEN. REPLACED SPRINGS AS NEEDED, OPS CHECKED GOOD.SDR SIMA972642Venturi · corrodedSAW - DURING CPCP-1 INSPECTION, MAINTENANCE DISCOVERED THE LAVATORY VENTURI ASSY CORRODED OUT OF LIMITS IAW SRM 53-61-00 FIGURE 401. MAINTENANCE REMOVED AND REPLACED VENTURI IAW SRM 51-25-02. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR 98ZZZM383Trim · corrodedFORWARD LAV INSIDE DIVIDER WALL, METAL LOWER TRIM PIECE CORRODED 6-8 INCHES LONG. REPLACED CORRODED TRIM PIECE ON FWD LAV DIVIDER WALL. (M)SDR 9712739936Call Switch · wire failedLEFT AFT LAVATORY SMOKE DETECTOR SOUNDED DURING TAXI-OUT. AIRCRAFT WAS RETURNED TO THE GATE. MAINTENANCE FOUND LAVATORY CALL BUTTON JAMMED AND WIRING BURNED BEHIND SWITCH. REPLACED SWITCH AMD MODULE, OPERATIONAL CHECK NORMAL.SDR DL72S971173Water Heater · overheatedSMOKE REPORTED IN AFT CABIN BY F/A, CONFIRMED BY SECOND OFFICER. BOTH AFT LAV SMOKE DETECTORS ALARMED, DID SMOKE CLEARANCE CHECKLIST. REPLACED AFT LAV WATER HEATER, CHECKS NORMAL.SDR CA970528024Mount · broke(CAN) MIRROR MOUNT BROKE OFF WHERE UPPER ARM TRANSITIONS FROM TUBE TO FLATTENED AREA FOR BOLTING TO UPPER BRACKET. THIS IS COMPANY BUILT FIXTURE.SDR 97ZZZX3002Wall Trim · corrodedATW - FORWARD LAVATORY WALL EDGE TRIM SHOWS SIGNS OF CORROSION ON LOWER END. REMOVED AND REPLACED CORRODED AREA OF WALL TRIM.SDR UPS97822094Insulation · saturatedA LINGERING SMELL AS STATED IN PREVIOUS WRITE-UPS. FOUND INSULATION IN FWD E/E BAY SATURATED IN LAV FLUID, REMOVED SAME. CLEANED AREA AND DEODORIZED. RAN PACKS. NO DEFECTS NOTED.SDR WWMA9700024Toilet · overservicedCREW REPORTED A STRONG OFFENSIVE ODOR, THE MORE FORWARD IN THE AIRCRAFT THE STRONGER THE ODOR. MAINTENANCE FOUND THE TOILET HAD BEEN OVERSERVICED SPILLING A LARGE AMOUNT OF BLUE WATER IN THE BELLY OF THE AIRCRAFT. THE TOILET FLUID WAS CLEANED AND NEUTRALIZEDSDR DLM11970116Faucet · leakingWITH A/P ON, WHEN FLIGHT SPOILERS WERE EXTENDED TO FULL, THE AIRCRAFT ROLLED LEFT TOWARD 30 DEGREE BANK. SPOILERS DON'T APPEAR TO EXTEND AT 1/3 AND 2/3 POSITION. AILERON TRIM WAS JAMMED DURING APPROACH, WILL NOT MOVE FROM ZERO POSITION. GROUND SPOILERS DID NSDR CA970130011Pump Motor · smoking(CAN) ON DEPARTURE FLIGHT ATTENDANT REPORTED SMELL OF SMOKE COMING FROM THE LAVATORY AND THE LAVATORY SMOKE DETECTOR WAS GOING OFF. FLIGHT RETURNED. ALL LIGHTS, WIRING, PUMP AND WASTE RECEPTACLE CHECKED, NO FAULT. REPLACED LAVATORY PUMP MOTOR.SDR GTIA96NK207Wall Covering · crackedDURING X-RAY INSPECTION OF AFT PRESSURE BULKHEAD VENTRAL STAIR DOOR FRAME A1.375 INCH CRACK WAS NOTED AT UPPER LEFT CORNER APPROX 6 INCH OUTBOARD OF CENTER RADIUS AT 11 O'CLOCK POSITION. DETAILED LOW FREQUENCY EDDY CURRENT AND A DETAILED VISUAL INSPECTION OF SDR CALA9601038Razor Outlet · inoperativeSMOKE WAS OBSERVED COMING FROM AREA OF FLUORESCENT LIGHT IN LT LAV AND THE SMOKE DETECTOR WAS SOUNDING WHILE EN ROUTE. LAV CIRCUITS WERE DEACTIVATED AND THE SMOKE CEASED. THE AIRCRAFT LANDED IN OMA WITHOUT INCIDENT. MAINTENANCE FOUND THE LT LAV RAZOR OUTLET SDR WWMA960052Tank Assy · dislocatedTHE CREW REPORTED A STRONG SMELL OF LAVATORY FLUSHING CHEMICAL IN THE CABIN. THEY NOTED IT SEEMED LIKE EITHER A CHEMICAL WAS LEAKING INTO THE CABIN OR THE LAV KEPT ON FLUSHING ON ITS OWN. MAINTENANCE FOUND THE TANK TO BE POSITIONED ON THE LIP OF ITS TRAY ANDSDR 96UAL900335Trash Bin · fireREPORT OF SMOKE IN LAVATORY AT DOOR 4 RIGHT SIDE. ADDITIONAL, REPORT OF FIRE IN LAVATORY TRASH BIN. ALARM DID NOT SOUND. WASTE COMPARTMENT EXTINGUISHER DID NOT DISCHARGE.SDR CA960320518Drain Frozen · frozen(CAN)FORARD LAVATORY AND GALLEY DRAINS OVERFLOWED DUE WATER DRAIN HEATER INOPERATIVE. FLOWED INTO ELECTRICAL COMPARTMENT RESULTING IN LOSS OF #1 & #2 EICAS ON LANDING. COMPUTERS REPLACED. DRAINS CLEARED.
Back to JASC 2540