SDR 97UAL900213Circuit Breaker · trippedEMERGENCY ESCAPE SLIDE SQUIB TEST NUMBER ONE WAS INOP. RESET CIRCUIT BREAKER C1. CHECKED OK.SDR MWEA97131Girt Bar · buckledCREW REPORTS AFT GALLEY SERVICE DOOR EMERGENCY EVAC SLIDE GIRT BAR DIFFICULT TO ARM/DISARM -- MTC REPOSITIONS GIRT BAR MATERIAL DUE TO BUCKLING. OPS CHECK GOOD. RETURNED AC TO SERVICE.SDR GTIA9700235Slide · fell offACY - FLT 805 - SLIDE PACK FELL OFF DOOR. SECURED SLIDE PACK ON GALLEY DOOR IAW MM 25-61. (X)SDR USAAD97055Lanyard · misroutedBOS - ON RE-CHECK OF FORWARD SERVICE DOOR ESCAPE SLIDE, SLIDE FAILED TO INFLATE. MAINTENANCE FOUND LANYARD MISROUTED. (M)SDR MWEA97127Slide Cover · fell offCREW REPORTS, FWD ENTRY DOOR EVACUATION SLIDE COVER FELL OFF. MAINTENANCE REINSTALLED FWD ENTRY SLIDE COVER.SDR SCNA97055Test Switch · inoperativeR1 DOOR SLIDE BOTTLE CHARGE TEST LIGHT WAS FOUND INOP. REPLACED TEST SWITCH IN ACCORDANCE WITH 25-61-03 AND REPAIRED BROKEN WIRE, OPS CHECKED GOOD.SDR MWEA97123Slide Cover · fell offGALLEY DOOR EVAC SLIDE COVER FELL OFF. MAINTENANCE REINSTALLED GALLEY DOOR SLIDE COVER.SDR MWEA97122Slide Cover · fell offFWD GALLEY SERVICE DOOR EVAC SLIDE COVER FELL OFF. MAINTENANCE REINSTALLED GALLEY SLIDE COVER.SDR DL757970375Megaphone · inoperativeF/C MEGAPHONE INOP DUE TO BATTERIES HOT. MAINTENANCE REPLACED MEGAPHONE AND BATTERIES.SDR CA970327004Connector · shorted(CAN) WALKAROUND FLASHLIGHT SHORTED CAUSING SPARKS AND SMOKE IN COCKPIT WHILE AIRCRAFT ON GROUND, REMOVED AND CB PULLED. CHARGER CONNECTOR FOUND SHORTED. REPLACED.SDR W8PA970096Fitting · corrodedDURING C-CHECK, FOUND CORROSION ON FORWARD ENTRY DOOR GIRT BAR FITTING MOUNTS. REMOVED CORROSION, FOUND PARTS OUT OF LIMITS, INSTALLED NEW FITTING MOUNTS IAW SRM 51-40-02. (M)SDR GTIA9700170Slide Pack · fell offACY - FLT 210 - ON POST FLIGHT SLIDE PACK FELL OFF GALLEY DOOR. INSTALLED SLIDE PACK BACK ON GALLEY DOOR PER MM 25-62-0. (M)SDR AU970191Ditching Dam · deployed(AUS) LH UNDERWING DITCHING DAM DEPLOYED IN FLIGHT - SEE MDR 97/0190FURTHER INFORMATION ON SIMILAR DEFECTSDR MWEA97113Evac Slide · fell offCREW REPORTS, FWD ENTRY DOOR EVAC SLIDE FELL OFF DOOR. MAINTENANCE REINSTALLED EVAC SLIDE, RETURNED A/C TO SERVICE.SDR AU970190Ditching Dam · failure(AUS) LH DITCHING DAM INFLATED - INVESTIGATION FOUND THAT THE CAUSE WAS THE FAILURE OF THE GASKET INSTALLED IN THE DITCHING DAM ADAPTERSDR VJ960121Slide Cover · fell offCOVER POPPED OFF R1 DOOR SLIDE. REINSTALLED SLIDE COVER PER MM 25-60. (M)SDR AU970324Fitting · broken(AUS) MAIN ENTRANCE DOOR L4 GIRT BAR AFT SLIDE FITTING BROKENSDR DL757970285Megaphone · inoperativeFOUND MEGAPHONE IN F/C COAT CLOSET ON THE FLOOR OF THE COAT CLOSET. UPON INSPECTION FOUND IT TO BE INOP. BATTERIES CHECK GOOD, INSTALLED NEW MEGAPHONE.SDR VJ970113Slide Cover · fell offL1 DOOR SLIDE COVER FELL. RESECURED SLIDE. (M)SDR ASAA9780029Lanyard · brokenRNO - PRIOR TO DEPARTURE OF FLT 613, CREW REPORTED THE L1 DOOR EMERGENCY EVACUATION SLIDE DEPLOY LANYARD WAS BROKEN. REPLACED THE DEPLOY LANYARD AND INSPECTED THE SLIDE AND COVER FOR SECURITY. (M)SDR MWEA97104Slide Cover · fell offMAINT REPORTS, FWD ENTRANCE DOOR SLIDE COVER FELL OFF. MAINT INSTALLED SLIDE COVER RETURNED A/C TO SERVICE.SDR MWEA97098Girt Bar Latch · out of adjustCREW REPORTS AFT SERVICE DOOR EVACUATION SLIDE GIRT BAR WILL NOT RELEASE. MAINT REMOVED GIRT BAR REPOSITIONED GIRT BAR LATCH.SDR SCNA97026Megaphone · inoperativeMEGAPHONE AT L2 WOULD NOT SELF TEST. REMOVED AND REPLACED MEGAPHONE.SDR MWEA97094Girt Bar Latches · lack of lubeCREW REPORTS AFT GALLEY SERVICE DOOR EVAC SLIDE GIRT BAR DIFFICULT TO REMOVE -- MAINT CLEANED AND LUBED GIRT BAR LATCHES. RETURNED A/C TO SERVICE.SDR CALA9700140Megaphone · inoperativeINSPECTION FOUND FORWARD CABIN MEGAPHONE INOPERATIVE. THE FORWARD CABIN MEGAPHONE WAS REPLACED.SDR CALA9700139Megaphone · inoperativeINSPECTION FOUND AFT CABIN MEGAPHONE INOPERATIVE. THE MEGAPHONE WAS REPLACED.SDR 9701889988Escape Line · bindingDURING PERIODIC CHECK, FOUND LEFT AFT OVERWING EMERGENCY EXIT ESCAPE LINE WINDING IN HOUSING. MAINTENANCE LUBED REEL. OPERATIONAL CHECK NORMAL.SDR DL757970161Indicator Light · inoperative3L DOOR SLIDE INDICATOR LIGHT INOP. RELAMPED, OPS CK GOOD.SDR VJ970010Cover · looseR1 DOOR SLIDE COVER CAME OFF. REINSTALLED SLIDE COVER IAW MM 25-60. (M)SDR MWEA97085Carpet · obstructionCREW REPORTS, FORWARD ENTRANCE DOOR EVACUATION SLIDE GIRT BAR IS DIFFICULT TO INSTALL. MAINTENANCE TRIMMED CARPET AWAY FROM GIRT BAR LATCH, OPS CHECK GOOD.SDR 97ZZZM206Slide · looseFLL - FOUND MAIN CABIN DOOR SLIDE PACK LOOSE. RESECURED MAIN CABIN SLIDE PACK DOOR AS REQUIRED IAW MM CH 25-61. (M)SDR VJ970006R1Cover · looseGALLEY DOOR SLIDE COVER LOOSE AT TOP. REINSTALLED EMERGENCY SLIDE COVER AND SLIDE IAW MM 25-60.SDR VJ970006Latch Assy · dirtyBOTH FORWARD SLIDES ARE HARD TO ARM AND DISARM. CLEANED UNDER LATCH ASSEMBLY ON SLIDE BAR. OPS CHECKED NORMAL. (M)SDR VJ970005Latch Assembly · dirtyBOTH FORWARD SLIDES ARE HARD TO ARM AND DISARM. CLEANED UNDER LATCH ASSEMBLY ON SLIDE BAR. OPS CHECKED NORMAL. (M)SDR 97ZZZM238Latch Assembly · dirtyBOTH FORWARD SLIDES ARE HARD TO ARM AND DISARM. CLEANED UNDER LATCH ASSEMBLY ON SLIDE BAR. OPS CHECKED NORMAL. REFERENCE VJ970005.SDR VJ970048Slide Cover · fell offL1 DOOR SLIDE PACK FELL OFF. REPLACED AND REINSTALLED L1 DOOR SLIDE IAW MM 25-62-0. (X)SDR DL73E970042Megaphone · inoperativeFOUND MEGAPHONE AT R2 INOP. REPLACED MEGAPHONE WITH SERVICEABLE UNIT, A/C LOG NR A208055.SDR CA970109004Clip · broken(CAN) SLIDE ASSEMBLY GIRT BAR RETAINER CLIP BROKEN OFF. REPLACED.SDR 97ZZZM398Girt Bar · frozenRIGHT FORWARD SERVICE DOOR SLIDE WILL NOT DISARM. NOTED GIRT BAR FROZEN AT THE FLOOR ABUTMENTS DUE TO EXCESSIVE WATER/ICE SPILLAGE ON THE FLOOR IN THE GALLEY AREA. INSPECTED AND OPERATED THE DOOR AND ASSOCIATED ARMING AND DISARMING MECHANISMS NUMEROUS TIMES.SDR 97UAL900083Arming Cable · brokenESCAPE SLIDE AT DOOR 2 LEFT DROPPED ONTO FLOOR WITHOUT DEPLOYING PRIOR TO DEPARTURE. EPAS (EMERGENCY POWER ASSIST SYSTEM) SYSTEM FUNCTIONED NORMALLY. DOOR ASSIST BOTTLE WAS DEPLETED, READS ZERO PRESSURE. REPLACED SLIDE AND EPAS RESERVOIR. REPLACED CABLE PSDR 97UAL900028Floor Fitting · out of adjustDOOR 1L WILL NOT OPEN ON ARRIVAL. CATCHES ON GIRT BAR LATCHES. *S/D* ARMING FLOOR FITTINGS 131W1830 OUT OF RIG, CAUSING SLIDE GIRT BAR TO HANG UP ON FITTINGS WHEN DOOR IS DISARMED. ADJUSTED FORWARD AND AFT FLOOR FITTINGS INWARD.SDR 96UAL901002Evacuation Slide · low pressureTHE NR 1 LEFT DOOR SLIDE PRESSURE READS AT THE BOTTOM OF THE GREEN BAND. *S/D* BOTTLE WAS COLD SOAKED CAUSING A FALSE LOW PRESSURE INDICATION.SDR DLM88962785Medical Kit · defectiveEMERGENCY MEDICAL KIT USED. REPLACED EMERGENCY MEDICAL KIT.SDR DLL10962775Megaphone · inoperativeFC MEGAPHONE INOP. REPLACED SAME.SDR MWEA96659Slide Cover · fell offCREW REPORTS WHILE PARKING AT GATE THE GALLEY SERVICE DOOR SLIDE COVER FELL OFF. -- REINSTALLED GALLEY SERVICE DOOR SLIDE COVER. RETURNED A/C TO SERVICE.SDR MWEA96658Evac Slide · fell offCREW REPORTS AFT GALLEY SERVICE DOOR SLIDE FELL OFF WHEN CATERERS OPENED DOOR. -- RESECURED AFT GALLEY DOOR EVACUATION SLIDE. RETURNED A/C TO SERVICE.SDR MWEA96657Girt Bar Latch · dirtyCREW REPORTS GALLEY SERVICE DOOR EVACUATION SLIDE GIRT BAR DIFFICULT TO ARM AND DISARM. -- MAINTENANCE CLEANED AND LUBED GIRT BAR LATCHES. OPS CHECK GOOD. RETURNED A/C TO SERVICE.SDR MWEA96656Slide Cover · fell offCREW REPORTS, FWD ENTRANCE EVAC SLIDE COVER FELL OFF. REINSTALLED FWD ENTRY DOOR SLIDE COVER. RETURNED A/C TO SERVICE.SDR 97ZZZM72Assist Bottle · deployedAFTER ARRIVAL 5L DOOR WAS INADVERTENTLY DEPLOYED. REMOVED AND REPLACED SLIDE AND DOOR ASSIST BOTTLE AS PER MM 25-65-01. OPS CHECKED NORMAL. A/C RETURN TO SERVICE. (M)SDR AALA961827Slide · looseORD - FLT 1700 - DURING CRUISE L1 DOOR EMERGENCY ESCAPE SLIDE IS LOOSE FROM DOOR AND SLIDE PACKAGE COVER. CAPTAIN DECLARED AN EMERGENCY AND LANDED ORD AND WITHOUT FURTHER INCIDENT. INSPECTED L1 DOOR SLIDE ASSEMBLY AND SECURED SLIDE AND COVER. (M)
Back to JASC 2560