JASC 2560
Service difficulty reports · 40,845
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MWEA96649Evac Slide · fell offCREW REPORTS, FWD GALLEY DOOR EVACUATION SLIDE FELL OFF DOOR. REINSTALLED FWD GALLEY DOOR EVACUATION SLIDE.SDR MWEA96648Evac Slide · fell offCREW REPORTS, FWD ENTRY DOOR EVACUATION SLIDE FELL OFF. REINSTALLED FWD ENTRY DOOR EVACUATION SLIDE.SDR MWEA96647Evac Slide · fell offCREW REPORTS, FWD ENTRY DOOR EVACUATION SLIDE FELL OFF. REINSTALLED FWD ENTRY DOOR EVACUATION SLIDE.SDR DLL13962554Megaphone · malfunctionedMEGAPHONE WEAK AT 4L.SDR CA961128031Lanyard Bracket · broken(CAN) GALLEY DOOR CHUTE PACK CAME ADRIFT. UNABLE TO INSTALL DUE TO BROKEN LANYARD ATTACHMENT BRACKET. MAINTENANCE INSTALLED NEW BRACKET CHECKED SERVICEABLE.SDR DLL10962535Evac Panel · fails testDURING H-CHECK, EVAC HORN AT L1 DOOR FAILED TO SOUND WHEN TESTED PER OPN 68111. REPLACED EVAC PANEL AT L1 DOOR, TESTS GOOD PRE OPN.SDR P9IA96033Megaphone · intermittentON PREFLIGHT, FOUND FORWARD MEGAPHONE INTERMITTENT. REMOVED AND REPLACED FORWARD MEGAPHONE. OPS CHECK OK IAW MM 25-60-0. (M)SDR MWEA96619Cover · looseGALLEY DOOR EMERGENCY ESCAPE SLIDE COVER NEEDS TO BE REINSTALLED. REINSTALLED SLIDE COVER.SDR 96UAL900836Slide Regulator · corrodedDURING OVERHAUL OF SLIDE, INFLATION REGULATOR FAILED. REGULATOR AND ASPIRATORS SHOWED SIGNS OF HEAVY CORROSION. DISASSEMBLY OF REGULATOR REVEALED FOD WAS PREVENTING NORMAL OPERATION OF THE REGULATOR.SDR CALA9601479Slide · fell offFORWARD ENTRY DOOR SLIDE FELL OFF DOOR. REINSTALLED SLIDE PACK PER MAINTENANCE MANUAL.SDR DL757962319Megaphone · weakMEGAPHONE WEAK. REPLACED MEGAPHONE.SDR AALA961507Squib Cartridge · defectiveGYE - DURING OVERNIGHT CHECK, LEFT AND RIGHT SYSTEM SQUIB TEST FOR OVERWING EMERGENCY EVACUATION SLIDES FAILED TO ILLUMINATE. AIRCRAFT MAINTENANCE FERRY GYE. REPLACED LEFT AND RIGHT OVERWING EMERGENCY EVACUATION SLIDE SQUIB CARTRIDGES. SYSTEM GROUND CHECKEDSDR 96UAL900770Press Ind · inoperativeNR 2 L-DOOR SLIDE TEST INOPERATIVE. REMOTE PRESSURE INDICATOR FOUND TO BE INOPERATIVE. REPLACED INDICATOR.SDR MZZA96077Latch Assembly · wire brokenDURING 1/2 D-CHECK INSPECTION ON AIRCRAFT AT AIR ASIA, EXCESSIVE BROKEN WIRES WERE FOUND ON L1 ENTRY DOOR ESCAPE SLIDE LATCH CABLE. THE DAMAGED ESCAPE SLIDE LATCH ASSEMBLY WAS REMOVED AND REPLACED PER B727 MM 25-60-15. REF HANGAR NON ROUTINE REPAIR ITEM CARDSDR DL757962205Megaphone · damagedF/A REPORTS, AFT MEGAPHONE BROKEN. REPLACED MEGAPHONE.SDR CALA9601329Spring · bentDOOR 2L WOULD NOT DISARM, THE LEVER WOULD NOT MOVE TO DISARM. MAINTENANCE FOUND LEAF SPRING ON GIRT BAR BENT. THE LEAF SPRING CLIP WAS REPLACED AND OPERATIONAL CHECKS WERE GOOD.SDR DLL10962163Megaphone · inoperativeF/C MEGAPHONE IS INOP. REPLACED MEGAPHONE.SDR DL76S962159Slide · malfunctionedL2 SERV DOOR ESCAPE SLIDE PACK FELL OUT OF DOOR UPON OPENING OF DOOR SLIDE. DID NOT FALL ENOUGH TO DEPLOY, DOOR WAS NOT FULLY OPENED. REPLACED L2 DOOR SLIDE ASSY, ARM/DIARM CKS NML. DOOR NOT FULLY DISARMED BY FLT ATTEND.SDR ASAA9680204Lanyard · disconnectedPDX - DURING MAINTENANCE CHECK, THE TAILCONE EMERGENCY EVACUATION SLIDE DEPLOY LANYARD WAS FOUND DISCONNECTED. RECONNECTED THE DEPLOY LANYARD AND INSPECTED THE DEPLOY MECHANISM FOR PROPER INSTALLATION AND SECURITY. (M)SDR 96UAL900716Assist Bottle · dischargedWHILE PERFORMING OPERATIONAL CHECK OF NR 2 AFT RIGHT DOOR AFTER SLIDE REPLACEMENT, THE DOOR ASSIST BOTTLE DISCHARGED AND DOOR WAS UNABLE TO OPEN.SDR 96ZZZM1483Door Assist Bott · emptyINADVERTENTLY, L1 DOOR WAS OPENED WHILE IN AUTO MODE SLIDE DEPLOYED. PERFORMED INSPECTION PER 5-51-23. REPLACED SLIDE AT L21 DOOR PER TC 25-665-1L AND REPLACED DOOR ASSIST BOTTLE AT L1 DOOR PER WIC 25-615-4-2. OPERATIONAL CHECKED NORMAL. AIRCRAFT RETURN TOSDR 96524Slide · fell offCREW REPORTS FWD ENTRY DOOR EVAC, SLIDE FELL OFF DOOR AND GIRT BAR WAS DIFFICULT TO REMOVE. REINSTALLED FWD ENTRY EVACUATION SLIDE AND TRIMMED CARPET GIRT BAR LATCH.SDR 96523Slide Cover · looseCREW REPORTS GALLEY SERVICE DOOR EVACUATION SLIDE COVER WILL NOT STAY SECURE. MAINTENANCE SECURED GALLEY DOOR EVACUATION SLIDE COVER.SDR 96520Slide · fell offCREW REPORTS FWD ENTRY DOOR EVACUATION SLIDE FELL OFF. MAINTENANCE REINSTALLED FWD ENTRY DOOR EVACUATION SLIDE.SDR ASAA9680195Mount · looseSEA - PRIOR TO DEPARTURE OF FLT 358, CREW REPORTED THE L2 DOOR EMERGENCY EVACUATION SLIDE GIRT BAR WOULD NOT ARM. FOUND THE AFT GIRT BAR FLOOR MOUNT LOOSE, SECURED MOUNT AND OPERATED NORMALLY. (M)SDR MWEA96432Batteries · dischargedCREW REPORTS CABIN MEGAPHONE INOP. MAINTENANCE REMOVED AND REPLACED BATTERIES OPS CHK GOOD.SDR ASAA9680189Escap Rope Clip · lodged in doorPDX - DURING MAINTENANCE CHECK, THE FORWARD RIGHT OVERWING EMERGENCY EXIT DOOR WAS FOUND DIFFICULT TO OPEN. FOUND ESCAPE ROPE CLIP LODGED BETWEEN DOOR AND FRAME. STOWED ESCAPE ROPE CLIP IN PROPER POSITION AND DOOR OPERATED NORMALLY. (M)SDR MWEA96428Slide Cover · looseGALLEY DOOR SLIDE COVER CAME OFF. REINSTALLED GALLEY SLIDE COVER.SDR MWEA96423Evac Slide · fell offCREW REPORTS FWD ENTRY DOOR EVACUATION SLIDE FELL OUT WHEN OPENING DOOR. REINSTALLED EVACUATION SLIDE.SDR DL72S962017Megaphone · inoperativeFWD MEGAPHONE BATTERY LOW. REPLACED MEGAPHONE, TESTS GOOD.SDR UPS96821444Lanyard · frayedINSPECTION TYPE: CS2. EVACUATION SLIDE LANYARD ASSY CABLE FRAYED. REPLACED LANYARD PER MM 25-60-01.SDR DL757961993Megaphone · failedF/C MEGAPHONE SQUEALS AT ALL VOLUME SETTINGS. REPLACED MEGAPHONE AND OPS CKS GOOD.SDR MWEA96422Slide · fell offCREW REPORTS GALLEY SERVICE DOOR EVACUATION SLIDE FELL OFF MOUNT. REINSTALLED GALLEY DOOR EVACUATION SLIDE.SDR DL757961953Batteries · dischargedMEGAPHONE AT 1L INOP.SDR UPS96620891Escape Rope · tangledFORWARD ENTRY DOOR ESCAPE ROPE TANGLED, WILL NOT DEPLOY. ROPE REINSTALLED BY BOEING DURING EO B767-3350-8522 UNDER BOEING 337 FORM FOR SB 767-33-0065 EMERGENCY LIGHT RELOCATION.SDR 96ZZZX4805Battery · defectiveDURING OVERHAUL OF RESCUE BEACON, FOUND FAILURE WAS DUE TO BATTERY NEG LEAD FAILURE. REMAINING STOCK CHECKED AND FOUND OTHERS DEFECTIVE. BATTERIES RETURNED TO MFG AND FOUND THOSE UNITS, S/N 21425 THROUGH S/N 21527, WERE SUSPECT TO FAILURE DUE TO A PRODUCTIONSDR MWEA96411Cover · looseMAIN CABIN DOOR SLIDE FELL OFF. REINSTALLED LATCH ASSY ON SLIDE COVER.SDR CA970311044Circuit Breaker · chafed(CAN) PILOT REPORTED SMOKE FROM AUXILIARY POWER/WATER BUCKET CIRCUIT BREAKER. CHAFED WIRE FOUND BEHIND DART PANEL.SDR MWEA96406Cover · fell offFWD ENTRY DOOR SLIDE COVER CAME OFF. REINSTALLED FWD ENTRY DOOR SLIDE AND COVER.SDR MWEA96402Slide Cover · fell offCREW REPORTS, GALLEY SERVICE DOOR EVAC SLIDE COVER FALLING OFF. REINSTALLED GALLEY DOOR SLIDE COVER.SDR MWEA96403Slide Cover · fell offDURING INSP, MAINT REPORTS GALLEY DOOR EVAC SLIDE COVER FELL OFF WHILE CLOSING DOOR. REINSTALLED GALLEY DOOR SLIDE COVER.SDR 96ZZZX4361Door Assist Btl. · out of adjustDURING A SPECIAL RIG CHECK, FOUND THREE DOORS THAT WERE NOT RIGGED PROPERLY AND WOULD NOT FIRE THE DOOR ASSIST BOTTLE. RE-RIGGED AND OPERATED NORMALLY, ADDED SPECIAL CHECK TO EACH C-CHECK.SDR MWEA96268Slide Cover · out of adjustDURING INSPECTION, FOUND AFT GALLEY SERVICE DOOR EVACUATION SLIDE COVER HITS DOOR JAMB WHEN OPENING AND CLOSING. ADJUSTED SLIDE COVER. OPS CHECK GOOD. RETURNED A/C TO SERVICE.SDR MWEA96267Girt Bar Spring · weakDURING C-CHECK, FOUND GALLEY SERVICE DOOR GIRT BAR LATCH SPRINGS WEAK. REPLACED GIRT BAR LATCH COMPRESSION SPRINGS.SDR P5CA9600396Slide Bar · worn throughDURING B-CHECK, FOUND RIGHT BODY GEAR OUTBOARD DOOR SLIDE BAR FORWARD UPPER FLANGE WORN THROUGH. FABRICATED AND INSTALLED NEW FLANGE CHANNEL PER BOEING SRM 51-10-01.SDR 97ZZZX327Slide · looseCRW - FLT 605 - LEFT FORWARD PASSENGER DOOR EVACUATION SLIDE WILL NOT DISARM, BUT MOVED APPROXIMATELY 1 INCH. CORRECTIVE ACTION: REMOVED AND REPLACED LOWER HINGE ROD END.SDR 96ZZZX4633Assist Bottle · misfiredDURING THE MINI-EVACUATION, THE L2 DOOR DID NOT OPEN PROPERLY. THIS CAUSED THE SLIDE/RAFT TO NOT DEPLOY PROPERLY. IT WAS FOUND THAT THE DOOR ASSIST BOTTLE DID NOT PROPERLY OPERATE. THE FIRING PIN WAS NOT STRIKING THE DISC HARD ENOUGH TO DISLODGE PROPERLY. SDR MWEA96258Slide Cover · fell offCREW REPORTS, GALLEY SERVICE DOOR SLIDE COVER FELL OFF. REINSTALLED GALLEY DOOR SLIDE COVER.SDR 96UAL900498Girt Bar · out of positionDOOR 2 LEFT SLIDE UNRAVELED, DOOR ASSIST BOTTLE BLOWN. *S/D* THE SLIDE GIRT MATERIAL WAS DISLODGED FROM ITS RETAINING TRAY FORCING THE MODE SELECT HANDLE TO THE DOOR ARM POSITION UPON DOOR OPENING. INSTALLED NEW SLIDE AND CHECK FOR PROPER STOWAGE OF GIRT MASDR 96UAL900489Evac Horn · malfunctionedFLIGHT DECK EMERGENCY EVACUATION HORN DOES NOT TEST. *S/D* PANEL ASSY WAS REMOVED AND REPLACED. REMOVED UNIT WAS TESTED IN SHOP AND NO FAULT WAS FOUND.
Back to JASC 2560