SDR 96UAL900132Aspirator · shearedDURING TEST INFLATION OF DOOR 5 RT SLIDE, AT OVERHAUL ONE ASPIRATOR SHEARED IN TWO. SHEAR POINT IS LOCATED BELOW THE RETAINING BANDS WHICH HOLD THE ASPIRATOR IN PLACE. REPLACED ASPIRATOR, RETURNED DAMAGED ASPIRATOR TO OEM FOR ANALYSIS.SDR MWEA96043Evac Slide · looseCREW REPORTS, GALLEY SERVICE DOOR EVAC SLIDE AND GIRT BAR IS LOOSE. RESECURED GALLEY DOOR SLIDE AND GIRT BAR.SDR UPS405533Release Mech · inoperativeMAINTENANCE REPORTED, FLIGHT DECK OVERHEAD ESCAPE HATCH WILL NOT UNLOCK AND OPEN. RESECURED LOOSE LINKAGE IN FLIGHT DECK OVERHEAD ESCAPE HATCH DOOR, OPS CHECKS NORMAL.SDR DLM11960354Press Indicator · failedPRESS TO TEST FUNCTION DID NOT WORK ON 4R DOOR PRESSURE INDICATOR LIGHT. LIGHT ILLUMINATED WHEN JACK CONNECTING IT TO SLIDE WAS DISCONNECTED. REPLACED INDICATOR ASSY, CHECKS GOOD.SDR AU960200Cable · damaged(AUS) HOIST CABLE DAMAGED - 15 OF 19 STRANDS DAMAGED - MEF INVESTIGATION FOUND FAILURE WAS DUE TO OVERLOADSDR MWEA96040Slide Cover · fell offCREW REPORTS, FWD GALLEY SERVICE DOOR SLIDE COVER FELL OFF. REINSTALLED GALLEY DOOR EVAC SLIDE COVER.SDR 96UAL900115Pusher Tube · failed testDURING OVERHAUL, DOOR 2 SLIDE FAILED AIR RETENTION TEST DUE TO POROSITY ON THE TOP PUSHER TUBE. PUSHER TUBE REPLACED BY OEM.SDR 96UAL900114Slide · failed testDURING OVERHAUL, DOOR 2 RIGHT SLIDE FAILED AIR RETENTION TEST DUE TO POROSITY ON BOTH FILL TUBES, TOP PUSHER TUBE AND CROSS TUBE. PATCHED AREAS OF POROSITY.SDR 96UAL900113Slide · failed testDURING OVERHAUL, DOOR 2 RIGHT SLIDE FAILED AIR RETENTION TEST DUE TO POROSITY ON BOTH FILL TUBES. PATCHED AREAS OF POROSITY.SDR MWEA96038Slide Cover · fell offCREW REPORTS MAIN ENTRANCE DOOR EVACUATION SLIDE COVER FELL OFF. REINSTALLED SLIDE COVER. RETURNED A/C TO SERVICE.SDR MWEA96037Slide Cover · fell offCREW REPORTS, GALLEY SERVICE DOOR EVACUATION SLIDE COVER CAME OFF. MAINTENANCE REINSTALLED SLIDE COVER.SDR UPS805370Container · crackedCREW REPORTED, ESCAPE SLIDE NEEDS TO BE REPACKED THE OUTER COATING CRACKED. REPACKED SLIDE IN CONTAINER, CONTAINER ASSY ON ORDER.SDR USAAD96014Slide Cover · not releasedPIT - DURING ANNUAL OPERATIONAL CHECK OF THE TAIL CONE EVACUATION SYSTEM, TAIL CONE WAS DROPPED BUT THE HARD COVER WHICH PROTECTS THE SLIDE WAS NOT RELEASED. THIS PREVENTED THE SLIDE FROM BEING DEPLOYED. MAINTENANCE WAS NOT ABLE TO DETERMINE WHY THE COVER RESDR ASAA9680042Container Latch · loosePDX - AFTER ARRIVAL OF FLT 586 - CREW REPORTED, THE L1 DOOR WAS DIFFICULT TO OPEN. FOUND EMERGENCY EVACUATION SLIDE CONTAINER LATCH LOOSE, SECURED LATCH AND OPERATED NORMALLY. (M)SDR 96UAL900074Valve Flange · crackedDURING SLIDE OVERHAUL, FOUND RIGHT HAND INFLATE/DEFLATE RUBBER MOUNTING FLANGE CRACKED. PROBABLE CAUSE WAS BENDING OF THE VALVE DURING SLIDE PACKING. REPLACED RUBBER INFLATE/DEFLATE VALVE FLANGE.SDR UPS405342Release Handle · brokenMAINTENANCE REPORTED, ESCAPE SLIDE RELEASE HANDLE CLIP BROKEN AND PAWL BROKEN MAKING ESCAPE SLIDE ARMED AND NOT SAFE. REMOVED AND REPLACED RELEASE HANDLE CLIP AND PAWL. SLIDE SECURED AND OPERATES FROM SAFE TO ARM NORMALLY.SDR SCNA96010Battery · dischargedL-1 PASSENGER DOOR SLIDE LOW PRESSURE LIGHT DOES NOT PRESS TO TEST. REMOVED AND REPLACED BATTERIES IN L-1 DOOR SLIDE AND SLIDE TESTED GOOD.SDR DL76L960186Slide Relay · defectiveON ALL CABIN SERVICE AND ENTRY DOORS, THE SLIDE ARMED LIGHT WILL NOT FLASH IN ARMED MODE WITH THE HANDLE SLIGHTLY PULLED. REPLACED DEFECTIVE RELAY, OPERATION NORMAL.SDR MWEA96017Girt Bar Latch · lack of lubeCREW REPORTS, AMIN ENTRANCE DOOR GIRT BAR LATCH VERY DIFFICULT TO OPERATE. CLEANED, LUBED LATCHES AND RESHIMMED FOR MORE CARPET CLEARANCE.SDR 96UAL900039Aspirator Assy · inoperativeCREW SLIDE FOUND WITH LARGE WAD OF PACKING PAPER BLOCKING ASPIRATOR FLAPPER DOORS. REMOVED ASPIRATOR FROM SLIDE AND REMOVED PAPER WAD. PAPER WAS INSTALLED IN THE ASPIRATOR AFTER MANUFACTURE TO PREVENT DOORS FROM OPENING/CLOSING DURING SHIPPING. PAPER NOT RESDR MWEA96014Slide Cover · fell offCREW REPORTS, FWD GALLEY DOOR EVACUATION SLIDE COVER CAME OFF. RESECURED GALLEY DOOR SLIDE COVER.SDR MWEA96006Slide Cover · looseCREW REPORTS, FWD GALLEY DOOR SLIDE COVER IS LOOSE. RESECURED FWD GALLEY DOOR SLIDE COVER.SDR MWEA96005Girt Bar Latch · lack of lubeCREW REPORTS, FWD ENTRY DOOR EVAC SLIDE GIRT BAR LATCH SPRING IS WEAK. CLEANED AND LUBED GIRT BAR LATCHES AND OPS CHECK GOOD.SDR ASAA9680013Bottle · low pressPDX - DURING MAINTENANCE CHECK, THE L1 DOOR EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS FOUND LOW. REPLACED THE L1 DOOR EMERGENCY EVACUATION SLIDE. (M)SDR DL72W960112Lanyard · brokenON PREFLIGHT, FOUND R-1 DOOR SLIDE GIRT BAR LANYARD BROKEN. REPLACED LANYARD, OPERATION NORMAL.SDR 96ZZZX1435Plates · corrodedLEVEL 2 CORROSION ON GIFT BAR BASE PLATES L-2 DOOR. REMOVED AND REPLACED PLATES PER SRM 51-10-02.SDR AU960041Arm · cracked(AUS) HOIST ARM CRACKED - SOME CORROSION EVIDENT IN AREA OF CRACKING - ARM IS USED TO ATTACH A LUCAS WESTERN RESCUE WINCH TO THEAIRCRAFTSDR UPS805338Slide · damagedWHILE IN FOR C-CHECK MAINTENANCE REPORTED, FWD ENT DOOR SLIDE PACK CANVAS GIRT BAR IS TORN AND FRAYED. REPLACED SLIDE ASSY PER MM 25-62-00.SDR 96ZZZX633Bottle · low pressureDURING A-CHECK, THE L-1 EMERGENCY EVACUATION SLIDE PACK PRESSURE WAS FOUND LOW. REPLACED SLIDE ASSEMBLY. VENDOR TEAR DOWN REVEALED LOW BOTTLE PRESSURE. OVERHAULED, HYDROSTATIC TESTED, AND REFILLED BOTTLE. REFERENCE: OPERATOR CONTROL NR ASAA9510118.SDR MWEA95540Evac Slide Cover · fell offDURING INSPECTION WHEN GALLEY SERVICE DOOR WAS OPENED THE EVACUATION SLIDE COVER FELL OFF. INSPECTED AND REINSTALLED SLIDE COVER.SDR MWEA95537Girt Bar Latch · dirtyCREW REPORTS, AFT LEFT SERVICE DOOR EVACUATION SLIDE GIRT BAR VERY DIFFICULT TO ENGAGE AND DISENGAGE. CLEANED AND LUBED GIRT BAR LATCHES, OPS CHECK GOOD.SDR SCNA95293Slide Press Ind · malfunctionedTHE L-2 DOOR SLIDE WOULD NOT TEST. REMOVED AND REPLACED SLIDE PACK PRESSURE INDICATOR IAW MM 25-61-03 AND SLIDE TESTED GOOD.SDR MWEA95534Slide Cover · fell offCREW REPORTS FORWARD ENTRANCE DOOR EVACUATION SLIDE COVER FELL OFF. RESECURED SLIDE COVER.SDR SCNA95290Slide Batteries · faultyTHE R-2 DOOR EVACUATION SLIDE WOULD NOT TEST. REMOVED AND REPLACED BATTERIES FOR THE EVACUATION SLIDE AND SELF TESTED IAW MM 25-61-03, OPS CHECKED GOOD.SDR MWEA95535Slide Cover · fell offCREW REPORTS FORWARD ENTRANCE DOOR SLIDE COVER FELL OFF. RESECURED DOOR SLIDE COVER.SDR 95UAL900321Slide · deployedDOOR 4 RIGHT ESCAPE SLIDE PARTIALLY INFLATED AFTER INADVERTENT DEPLOYMENT. SLIDE INADVERTENTLY DEPLOYED CONTACTING FOOD SERVICE TRUCK WHICH PRODUCED AN L-SHAPED TEAR ON THE AFT TOP INFLATION TUBE. REPAIRED TEAR AND MADE SLIDE SERVICEABLE.SDR MWEA95530Girt Bar Latch · fouledCREW REPORTS FORWARD ENTRANCE DOOR EVACUATION SLIDE IS DIFFICULT TO DISARM. TRIMMED CARPET AROUND FORWARD GIRT BAR LATCH.SDR UPS805138Bottle · out of limitsMAINTENANCE REPORTED BOTTLE PRESSURE OF 2500 PSI AT 25 DEGREES FAHRENHEIT, INBOARD EVACUATION SLIDE. INSTALLED SLIDE ROBBED FROM N755UP.SDR DL767954642Battery · dischargedSQUIB TEST 1 THE LEFT LIGHT DOES NOT COME ON FOR SLIDE. SQUIB TEST 2 THE RIGHT LIGHT DOES NOT COME ON FOR SPOLILER. REPLACED RIGHT HAND OVER WING SLIDE BATTERY ASSEMBLY. SYSTEM SQUIB TEST CHECKS AS PER M/M. .SDR DL757954608Slide Bulb · failedFORWARD R1 SIDE DOOR SLIDE LIGHT BURNED OUT IN-FLIGHT. RELAMPED BULBS, OPERATION NORMAL.SDR MWEA95436Megaphone · inopCREW REPORTS, A/C MEGAPHONE INOP. MAINTENANCE REMOVED AND REPLACED MEGAPHONE AND RETURNED A/C TO SERVICE.SDR P2RA950033Sill · out of adjustPASSENGER DOOR R2 SLIDE WILL NOT DISARM AT TERMINATION OF FLIGHT. MAINTENANCE INSPECTED THE R2 DOOR SLIDE ARMING SYSTEM AND READJUSTED AFT SILL PLATE AS PER AMM 52-10-11. RESULTS SATISFACTORY. AIRCRAFT RELEASED FOR SERVICE. (M)SDR P2RA950031Girt Bar · lack of lubeFLT NR 300, LGB-ATL - R2 DOOR WILL NOT DISARM. MAINTENANCE UNABLE TO DUPLICATE, DOOR DISARMED ON ARRIVAL. LUBED ARM/DISARM HANDLE AND SLIDE BAR LINKAGE. OPERATIONAL CHECK NORMAL PER AMM 52-22-22. (M)SDR P2RA950030Girt Bar · inoperativeFLT NR 603 - CREW REPORTED THAT R2 DOOR COULD NOT BE DISARMED AFTER LANDING. REINSTALLED GIRT SLIDE BAR ON DOOR. CHECKED NORMAL PER AMM 52-22-22. (M)SDR MWEA95433Girt Bar Latches · dirtyCREW REPORTS, GIRT BAR ON FWD PAX DOOR IS DIFFICULT TO ARM AND DISARM. MAINTENANCE CLEANED AND LUBRICATED GIRT BAR LATCHES. OPS CHECK GOOD AND A/C RETURNED TO SERVICE.SDR MWEA95432Slide Pin · fell outCREW REPORTS, GALLEY SERVICE DOOR EVACUATION SLIDE COVER RETAINING PIN FELL OUT. MAINTENANCE REPLACED EVACUATION SLIDE DOOR AND PIN, RETURNED A/C TO SERVICE.SDR DL757954411Slide Bottle · low pressureDURING SERVICE CHECK, FOUND R-2 SLIDE BOTTLE PRESSURE BELOW LIMITS. REPLACED SAME.SDR P2RA950029Girt Bar · inoperativeR-2 DOOR WILL NOT DISARM. OPERATED DISARM HANDLE SEVERAL CYCLES, DOOR DISARM OK PER MM 52-22-22. (X)SDR P2RA950027Girt Bar · malfunctionedR-2 DOOR WILL NOT DISARM. CHECKED GIRT BAR AND SLIDE BAR FOR BEING IN PLACE, CHECKED OK, CYCLED ARM/DISARM HANDLE, OPERATES NORMALLY PER MM 52-22-22. (X)SDR AALA951948Bracket · brokenEZE - FLT 0900 - WHILE AT GATE, FOUND THE 4R DOOR FORWARD SLIDE BAR BRACKET BROKEN. PLACARDED 4R DOOR/SLIDE INOPERATIVE PER MEL. REPLACED FORWARD SLIDE BAR BRACKET AND REMOVED MEL IN MIA. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)
Back to JASC 2560