SDR DL73S954360Megaphone · failedON 7802L, FOUND F/C GALLEY MEGAPHONE WOULD NOT PROJECT VOICE WHEN THE BUTTON ON THE HANDLE WAS PUSHED. TRIED CHANGING THE BATTERIES, NO HELP. REPLACED MEGAPHONE.SDR MWEA95365Evac Slide · looseCREW REPORTS, UPON LANDING THE GALLEY SERVICE DOOR EMERGENCY EVACUATION SLIDE BECAME LOOSE. MAINTENANCE RESECURED ESCAPE SLIDE, RETURNED A/C TO SERVICE.SDR P2RA950025Girt Bar · inopR-2 DOOR SOMETIMES DOES NO DISARM. INSPECTED, CLEANED AND LUBRICATED DOOR. NO PROBLEMS FOUND, OPS CHECKED GOOD. (M)SDR P2RA950024Girt Bar · inopON ARRIVAL, UNABLE TO DISARM R-2 DOOR. REINSTALLED GIRT BAR IN FORWARD END LATCH, OPS CHECKED GOOD PER MM 52-22-22. (M)SDR P2RA950022Girt Bar · inopR-2 DOOR WOULD NOT DISARM. MANUALLY DISARM GIRT BAR. REINSTALLED GIRT BAR AND CHECKED GOOD PER MM 52-22-22. (M)SDR DLM88954320Lanyard · brokenON PREFLIGHT, L-2 DOOR SLIDE LANYARD WIRE FOUND BROKEN. REPLACED LANYARD.SDR P2RA950020Girt Bar · inoperativeATL - FLT CREW FOUND L2 DOOR GIRT BAR WILL NOT ENGAGE. ITEM WAS DEFERRED PER MEL 15-61-01. MAINTENANCE REINSTALLED GIRT BAR ON L-2 DOOR. PERFORMED OPERATIONAL CHECKS PER AMM 52-22-22. RESULTS SATISFACTORY. AIRCRAFT RELEASED FOR SERVICE. (X)SDR UPS504904Battery Wire · brokenWHILE ON GROUND IN EAST MIDLANDS, MAINTENANCE FOUND PIREP-EMERGENCY ESCAPE SLIDE BATTERY PACK WIRING BROKEN. MAINTENANCE REMOVED THE SLIDE AND DEFERRED PER E.O. MRR FILED OPEN.SDR UPS804904Battery Wire · brokenSUPPLEMENTAL MRR: WHILE ON THE GROUND IN EAST MIDLANDS, MAINTENANCE FOUND THE EMERGENCY ESCAPE SLIDE BATTERY PACK WIRING BROKEN. MAINTENANCE REMOVED THE SLIDE AND DEFERRED EPR EO. MAINTENANCE ALSO SECURED SLIDE PACK AS REQUIRED.SDR 9516646302Connector · looseTPE - DURING LINE CHECK, THE DOOR 5L EMERGENCY SLIDE LIGHT WOULD NOT EXTINGUISH. CHECKED WIRING AND RESEATED CANNON PLUG, OPERATIONAL CHECK OK.SDR TWRA9562Girt Bar · dirtyR4 DOOR WOULD NOT GO INTO AUTO. CLEANED GIRT BAR FITTING, DOOR OPERATION NORMAL. (X)SDR 95UAL900212Slide Press · lowDOOR 1 LEFT EVACUATION SLIDE PRESSURE INDICATING IN RED, APPROX 2,800 PSI. SERVICED PER MAINTENANCE MANUAL.SDR DL72S954139Girt Bar Hook · brokenON DEPARTURE, FWD ENTRY DOOR SLIDE GIRT BAR HOOK BROKEN, REPLACED HOOK, OPERATION NORMAL.SDR MWEA95352Slide Cover · fell offDURING SERVICE CHECK, FOUND FWD GALLEY SERVICE DOOR EVACUATION SLIDE COVER HAD FALLEN OFF. MAINTENANCE REINSTALLED EVAC SLIDE COVER AND RETURNED A/C TO SERVICE.SDR 95ZZZM609Girt Bar · misalignedR-2 DOOR WOULD NOT DISARM ON GROUND. PLACARDED PER MEL 25-61-01. REINSTALLED FORWARD END OF GIRT BAR. OPS CHECKED OK PER MM 25-60-00. PLACARD REMOVED. (M)SDR UPS204745Evac Slide · unsecuredWHILE ON GROUND, MAINTENANCE FOUND ENTRY DOOR EVAC SIDE GIRTH BAR FAILED TO LATCH. MAINTENANCE RE-PACKED EVAC SLIDE.SDR UPS804745Slide · unsecuredWHILE ON GROUND, MAINTENANCE FOUND ENTRY DOOR EVACUATION SLIDE GIRTH BAR FAILED TO LATCH. REPACKED EVACUATION SLIDE.SDR MWEA95348Slide Cover · fell offCREW REPORTED PASSENGER ENTRANCE DOOR SLIDE COVER FELL OFF. MAINTENANCE RESECURED SLIDE COVER. AIRCRAFT RETURNED TO SERVICE.SDR MWEA95341Girt Bar Mount · looseDURING INSPECTION, THE TAIL EVACUATION SLIDE GIRT BAR WAS FOUND LOOSE ON RIGHT MOUNT. MAINTENANCE TIGHTENED RIGHT SIDE GIRT BAR MOUNT AND RETURNED A/C TO SERVICE.SDR MWEA95323Slide Cover · fell offGALLEY DOOR SLIDE COVER CAME OFF WHEN OPENED FOR CATERING TRUCK. REPOSITIONED SLIDE IN HOLDER AND REINSTALLED THE DOOR SLIDE COVER.SDR SCNA95193Slide Indicator · failedTHE R-3 DOOR SLIDE WOULD NOT TEST. REPLACED THE R-3 DOOR TEST INDICATOR AND SLIDE TESTED GOOD PER MM 25-61-03.SDR MWEA95301Evac Slide · fell offCREW REPORTS UPON ARRIVAL TO THE A/C IN THE MORNING, THEY FOUND THE FORWARD GALLEY SERVICE DOOR EVACUATION SLIDE HAD FALLEN OFF DOOR. MAINTENANCE REINSTALLED GALLEY DOOR EVACUATION SLIDE. RETURNED A/C TO SERVICE.SDR 96ZZZM86Clip · brokenBOS - L-1 GIRT BAR CLIP BROKEN. REPLACED L-1 SLIDE PER M/M 25-61-01, OPS CHECKS NORMAL. (M)SDR MWEA95297Slide Cover · fell offCREW REPORTS, COVER FOR AFT GALLEY DOOR EVACUATION SLIDE FELL OFF. MAINTENANCE REINSTALLED AFT GALLEY DOOR EVACUATION SLIDE COVER AND RETURNED A/C TO SERVICE.SDR MWEA95285Slide Cover · fell offCREW REPORTS, GALLEY DOOR EVACUATION SLIDE COVER FELL OFF. MAINTENANCE RESECURED GALLEY DOOR EVACUATION SLIDE COVER AND RETURNED A/C TO SERVICE.SDR SCNA95181Test Light Batt · dischargedTHE R-2 DOOR SLIDE INTEGRITY TEST LIGHT DID NOT ILLUMINATE WHEN PRESSED. REMOVED AND REPLACED TEST BATTERIES, AND SLIDE TESTED GOOD.SDR MWEA95281Girt Bar Latch · dirtyCREW REPORTS, FORWARD ENTRANCE DOOR EVACUATION SLIDE GIRT BAR IS HARD TO REMOVE AND INSTALL. MAINTENANCE CLEANED AND LUBED GIRT BAR LATCHES. OPS CHECK GOOD, RETURNED A/C TO SERVICE.SDR MWEA95271Slide Cover · fell offCREW REPORTS, GALLEY EVACUATION SLIDE COVER FELL OFF AT GATE. MAINTENANCE RESECURED GALLEY EVAC SLIDE COVER AND REMOVED A/C TO SERVICE.SDR MWEA95270Evac Slide · fell offCREW REPORTS, FWD GALLEY DOOR EVACUATION SLIDE CAME OFF ITS MOUNT. MAINTENANCE REINSTALLED GALLEY DOOR EVACUATION SLIDE. RETURNED A/C TO SERVICE.SDR MWEA95267Bar Latch · dirtyCREW REPORTS, GALLEY SERVICE DOOR EVACUATION SLIDE GIRT BAR LATCH SPRING IS BROKEN. MAINTENANCE FOUND SPRING OK, BUT LATCH WAS DIRTY. CLEANED AND LUBRICATED LATCH. OPS CHECK GOOD, RETURNED A/C TO SERVICE.SDR 95268Clip · brokenCREW REPORTS, GALLEY DOOR EVACUATION SLIDE LOOSE. MAINTENANCE INSTALLED NEW INNER SLIDE CUP RETAINER CLIP. REINSTALLED EVACUATION SLIDE, RETURNED A/C TO SERVICE.SDR 96ZZZX3283Slide Bottle · low pressureMEM - SLIDE PRESSURE LOW. REMOVED L1 SLIDE, SERVICED BOTTLE IAW CMM 25-60-10. REINSTALLED L1 SLIDE IAW MM 25-61-311.SDR MWEA95263Slide Cover · fell offCREW REPORTS, THE GALLEY SERVICE DOOR SLIDE COVER FELL OFF IN FLIGHT. MAINTENANCE RESECURED GALLEY DOOR SLIDE COVER. RETURNED A/C TO SERVICE.SDR MWEA95262Evac Slide · fell offCREW REPORTS, MAIN ENTRANCE DOOR EVACUATION SLIDE FELL OFF, WHEN DOOR OPENED AT GATE. MAINTENANCE RESECURED SLIDE AND COVER. RETURNED A/C TO SERVICE.SDR MWEA95260Slide Cover · fell offCREW REPORTS FORWARD ENTRANCE DOOR SLIDE COVER FELL OFF. MAINTENANCE RESECURED FORWARD ENTRANCE SLIDE COVER. RETURNED A/C TO SERVICE.SDR 95UAL900078Slide Bottle · failedRT NR 2 SLIDE PRESSURE WILL NOT TEST IN COCKPIT. REPLACED SLIDE BOTTLE.SDR 95UAL900065Slide Light · malfunctionedAT DEPARTURE TIME, JETWAY OFF, FLT ATTENDANT ADVISED DOOR 2 LEFT SLIDE PRESS LIGHT WOULD NOT TEST. REINSTALLED BATTERY. OPS CHECKED OK.SDR MWEA95242Slide Cover · detachedCREW REPORTS, GALLEY SERVICE DOOR SLIDE COVER NOT SECURE. MAINTENANCE RESECURED SLIDE COVER, RETURNED A/C TO SERVICE.SDR 95UAL900055Slide Bottle · low pressFLIGHT ATTENDANT REPORTS, SLIDE PRESSURE LOW AT 1L. SERVICED BOTTLE.SDR 95UAL900054Girt Bar · looseFWD SERVICE DOOR SLIDE GIRT BAR WILL NOT STAY SECURED. REPLACED SLIDE.SDR MWEA95241Girt Bar Latches · lack of lubeCREW REPORTS, AFT GALLEY SERVICE DOOR SLIDE GIRT BAR STICKS IN THE ARMED POSITION. MAINTENANCE CLEANED AND LUBRICATED GIRT BAR LATCHES. OPS CHECK GOOD, RETURNED A/C TO SERVICE.SDR USAA950773Slide · malfunctionedDCA - WHILE INSPECTING THE TAIL AREA FOR FUEL FUMES, THE TAILCONE WAS INADVERTENTLY DEPLOYED. THE TAIL SLIDE DID NOT DEPLOY. THE SLIDE WAS RERIGGED WITH THE TAIL CONE LANYARD TO DETERMINE THE REASON FOR THE SLIDE NOT DEPLOYING. MAINTENANCE RERIGGED THE SLIDSDR MWEA95237Cover · off hingeDURING ROUTINE INSPECTION, THE TAIL EMERGENCY SLIDE COVER WAS FOUND NOT INSTALLED ON HINGE. MAINTENANCE RESECURED TAIL SLIDE COVER. RETURNED A/C TO SERVICE.SDR 95ZZZM618Latch Cable · misroutedALL EMERGENCY ESCAPE SLIDES LATCH CABLE NOT PROPERLY ROUTED. REMOVED AND REPOSITIONED CABLE.SDR P9IA95002Door · jammedDURING DITCHING DEMONSTRATION, FORWARD OVERHEAD RAFT COMPARTMENT DOOR JAMMED ON OPENING. FOUND INERTIA REEL JAMMED. SEVERAL TEETH BROKEN ON GEARS. (X)SDR 95ZZZX5189Girt Bar · brokenLAX - R3 DOOR SLIDE ACCIDENTLY DEPLOYED DUE TO GIRT BAR TUBE BROKEN. REPLACED SLIDE.SDR MWEA95234Girt Bar · lack of lubeCREW REPORTS, IT WAS VERY DIFFICULT TO DISARM THE AFT GALLEY SERVICE DOOR EVACUATION SLIDE GIRT BAR. MAINTENANCE CLEANED AND LUBRICATED AFT GALLEY DOOR SLIDE GIRT BAR. RETURNED A/C TO SERVICE.SDR MWEA95229Slide Cover · fell offCREW REPORTS, FWD ENTRANCE DOOR EVAC SLIDE COVER FELL OFF. MAINTENANCE RESECURED SLIDE COVER, RETURNED A/C TO SERVICE.SDR MWEA95226Lanyard · brokenDURING ROUTINE MAINTENANCE, THE GALLEY SERVICE DOOR EVACUATION SLIDE LANYARD WAS FOUND TO BE BROKEN. MAINTENANCE REPLACED EVAC SLIDE LANYARD. RETURNED A/C TO SERVICE.SDR AALA951147Bottle · defectiveORD - DURING SLIDE SHOP RECEIVING INSPECTION, EMERGENCY EVACUATION SLIDE P/N CBB3335, FOUND WITH LOW BOTTLE PRESSURE. REPLACED EMERGENCY EVACUATION SLIDE BOTTLE. (M)
Back to JASC 2560