Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2564' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2564' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 97ZZZM1219Slide/Raft · failedDURING A SLIDE/RAFT DEMONSTRATION, FOR TRAINING FOR A GROUP OF F/A'S AT JFK, SLIDE MOUNTED AT 2R DOOR FAILED TO DEPLOY. REMOVED AND REPLACED SLIDE/RAFT PER MM 25-69-00 AND TC 25-665-2R. REMOVED AND REPLACED DOOR ASSIST BOTTLE PER MM 52-11-06 AND WIC 25-617-2SDR K3HA9700109Life Raft · low pressureON PREFLIGHT FOUND AFT/FOWARD BOTTLE LOW PRESSURE. REMOVED AND REPLACED LIFE RAFT FWD/AFT POSITION PER MM 25-60-0.SDR 97ZZZX4821Raft · mispackedWHILE CONDUCTING A PRELIMINARY INSPECTION ON RAFT, TEMPORARY WEB TIES WERE FOUND INSTALLED. THESE TIES ARE USED AS SHOP AIDS FOR PACKING THE RAFT AND MUST BE REMOVED BEFORE THE UNITS ARE RETURNED TO SERVICE.SDR 97UAL900566Restraint Strap · missingD-RING MISSING FROM SLIDE AT DOOR 4-LEFT. *S/D* D-RING AT THE END OF RESTRAINT STRAP ON SLIDE RAFT WAS FOUND MISSING. ENTIRE RESTRAINT STRAP ASSY WAS REPLACED.SDR 97UAL900560Strap · missingDOOR 2-RIGHT D-RING SLIDE RAFT RESTRAINING STRAP MISSING. *S/D* D-RING AT THE END OF THE RESTRAINT STRAP ON SLIDE RAFT WAS FOUND MISSING. ENTIRE RESTRAINT STRAP ASSEMBLY WAS REPLACED.SDR 97UAL900542Tube · leakingDURING SHOP OVERHAUL OF SLIDE/RAFT, FOUND THAT LOWER TUBE RELIEF VALVE HAD WORN A HOLE IN THE LOWER TUBE DOG LEG AND THROUGH TO THE UPPER TUBE REPAIRED HOLE IN DOG LEG WITH A PATCH ON THE OUTSIDE. REPAIRED HOLE BETWEEN LOWER AND UPPER TUBES WITH A PATCH ON TSDR 97UAL900531Tube · rupturedDURING THE SLIDE RAFT RETENTION TEST, THE BOTTOM CENTER SUPPORT TUBE SEAM SEPARATED. THE SLIDE RAFT WAS DISCARDED.SDR 97UAL900530Tube · rupturedTHE LOWER TUBE RUPTURED AND FAILED ON A SLIDE RAFT DURING OVER-PRESSURE TESTING. THIS FAILURE OCCURRED AT THE RIGHT FORWARD SUPPLEMENTAL TUBE BULK HEAD SEAM. THE SLIDE RAFT WAS DISCARDED.SDR AU970509Life Raft · faulty(AUS) LIFERAFT INCORRECTLY PACKED - GAS BOTTLE DUE FOR HYDROSTATIC TEST ON 10/96 - LIFERAFT HAD JUST ARRIVED FROM OVERSEAS -PERSONNEL/MAINTENANCE ERRORSDR IXKA9700020Life Raft · low pressFORWARD OVERHEAD LIFE RAFT HAS LOW PRESSURE. REPLACED FORWARD OVERHEAD LIFE RAFT AS PER 25-60-0. (M)SDR IXKA9700019Life Raft · missingIN FORWARD LIFE RAFT COMPARTMENT, AFT LIFE RAFT IS MISSING. REPLACED AFT LIFE RAFT IN FWD LIFE RAFT COMPARTMENT AS PER 25-60-00. (M)SDR HAIHEEA9297Life Raft · wrong sizeUNABLE TO INSTALL RAFT IN RAFT COMPARTMENT AS DIMENSIONS OF RAFT ARE GREATER THAN OPENING.SDR 97ZZZX1452Safety Valve · misassembledDURING ANNUAL INSPECTION SERVICE OF A 6-MAN LIFE RAFT, THE CYLINDER SAFETY VALVE DISK WAS INSPECTED. AN EXTRA SAFETY DISK RO508-RA AND AN EXTRA O-RING 514-05B WERE FOUND INSTALLED ON TOP OF THE ORIGINAL O-RING AND DISK. THESE WERE REMOVED AND THE SYSTEM RE-ASDR 97UAL900036Raft · deployedLIFERAFT IN AFT CABIN INFLATED WHILE AIRCRAFT CLOSED AND LOCKED FOR OVERNIGHT. INVESTIGATION REVEALED THAT AN INCORRECT O-RING WAS USED IN THE INFLATION CYLINDER REGULATOR. ALL CARLTON REGULATORS WERE RECALLED AND CHECKED. RAFT REPLACED. OPERATION CHECKS NSDR UPS96821704Life Raft · deployedINSPECTION TYPE-N/A, AFT LIFE RAFT PARTIALLY DEPLOYED. REMOVED AND REPLACED AFT LIFE RAFT ASSY UNDER COURIER SEATS.SDR TAOA089611Raft · deployedFLIGHT ATTENDANT TRAINING, DEPLOYED RAFT. RAFT INFLATION AND EMERGENCY EQUIPMENT CHECKED NORMAL. (M)SDR TWRA96268Slide Raft · deployedDURING B-CHECK, FOUND L2 DOOR WAS OPENED AFTER ARMING. SLIDE PARTIALLY DEPLOYED AND DOOR ASSIST BOTTLE FULLY DISCHARGED. REMOVED AND REPLACED ESCAPE SLIDE RAFT AND ACCESS ASSIST DOOR BOTTLE ON L2 DOOR AS PER MM 25-69-00. OPERATION CHECK NORMAL. (M)SDR HEEA967520Life Raft · straps brokeLIFE RAFT STRAPS BROKE UPON INSTALLATION. (REPACK AND RETURN)SDR SCNA96179Liferaft · rupturedDURING FLIGHT ATTENDANT TRAINING, AIRCRAFT RAFT FAILED TO DEPLOY PROPERLY.SDR 96ZZZX3755Cylinder · rustedTWO REPLACEMENT CYLINDERS RECEIVED FROM HOOVER IND FOR A MODEL FR-46 LIFE RAFT WERE FOUND TO BE UNACCEPTABLE. THESE CYLINDERS WERE MANUFACTURED IN 8/95 AND 1/96. THESE CYLINDERS WERE TO BE REPLACEMENTS FOR THE TWO INSTALLED ON THE RAFT AND WERE FOUND TO HAVESDR 96ZZZX3754Cylinder · rustedTHIS FACILITY RECEIVED A HOOVER IND MODEL FR-46, S/N J47 FOR OVERHAUL. UPON INSPECTION AND PRIOR TO PERFORMING A HYDROSTATIC RE-TEST, THE TWO INSTALLED INFLATION CYLINDERS WERE FOUND TO HAVE INTERNAL RUST. (CAUSE FOR REJECTION.) BOTH CYLINDERS HAVE A 521 9SDR 96ZZZX3753Cylinder · rustedTHIS FACILITY RECEIVED A HOOVER IND MODEL FR-46, S/N J47 FOR OVERHAUL. UPON INSPECTION AND PRIOR TO PERFORMING A HYDROSTATIC RE-TEST, THE TWO INSTALLED INFLATION CYLINDERS WERE FOUND TO HAVE INTERNAL RUST. (CAUSE FOR REJECTION.) BOTH CYLINDERS HAVE A 521 9SDR 96UAL900313Slide Raft · damagedDOOR 3 LEFT OFFWING SLIDE/RAFT REMOVED FOR TIME LIMIT. SHOP FOUND RAMP PORTION OF SLIDE DAMAGED DUE TO SEPARATION OF THE INTERNAL BULKHEADS. SCRAPPED RAMP PORTION OF SLIDE/RAFT.SDR HEEA967053Life Raft · wont installCOULD NOT INSTALL RAFT. MEASURED OLD RAFT AT APPROX. 9 1/2" AND NEW RAFT MEASURED APPROX. 10 1/2".SDR TAOA049605Asperator · crackedAN UNSERVICEABLE OVERDUE LIFE RAFT WAS USED FOR FLIGHT ATTENDANT TRAINING DEPLOYMENT EXERCISE. INFLATION OF LIFE RAFT WAS NORMAL WITH RAPID DEFLATION, CAUSED BY 2 EACH PRESSURE ASPERATORS (PN 743GPS-1) RUBBER BUTTERFLY TYPE DIAPHRAGMS FOUND CRACKED AND DETERISDR 96UAL900136Valve Body · looseFIRST TIME OVERHAUL ON THE 46 MAN RAFT REVEALED THAT THE VALVE BODY WAS LOOSE FROM THE PRESSURIZATION CYLINDER. CYLINDER PRESSURE WAS ACCEPTABLE, RETORQUED VALVE BODY TO CYLINDER PRIOR TO RECHARGE.SDR 96ZZZX1551Raft · failedDURING AN EXERCISE, RAFT FAILED TO INFLATE. INSPECTION SHOWED CO2 BOTTLE VALVE DID NOT OPEN TO EXPEL CO2. CERTIFICATION DUE DATE WAS 2-15-96.SDR 96ZZZX474Cylinder · fail testINFLATION CYLINDER FAILED HYDROSTATIC RETEST DUE TO EXCESSIVE ELASTIC EXPANSION. HOOVER IND. P/N 102-1 (165 CUBIC INCHES), S/N A649700. CAUSE WOULD BE IN MANUFACTURING. RECOMMEND MANUFACTURER BE CONTACTED. DATE OF MFG IS 7-93, THIS WAS ITS FIRST RETEST.SDR AALA952107Raft · defectiveLAX - DURING SHOP TEST DEPLOYMENT, EMERGENCY EVACUATION RAFT HAD SEAM SEPARATION. EMERGENCY EVACUATION RAFT SCRAPPED. (X)SDR 95UAL900168Slide Raft · tornDURING TIME CONTROLLED OVERHAUL OF A DOOR NR 2 RIGHT HAND SLIDE/RAFT, THE LOWER LEFT HAND INFLATION TUBE BURST DURING PROOF PRESSURE TEST. INTERNAL BULKHEAD IS SPLIT FOUR FEET AND INFLATION TUBE IS TORN IN TWO PLACES. RETURNED SLIDE/RAFT TO VENDOR FOR REPAIRSDR AALA951703Slide Raft · defectiveLAX - DURING SHOP TEST DEPLOYMENT, EMERGENCY EVACUATION SLIDE RAFT SEPARATED AT LEFT ASPIRATOR TUBE. EMERGENCY EVACUATION SLIDE RAFT ROUTED TO VENDOR FOR REPAIR. (M)SDR AALA951702Slide Raft · defectiveLAX - DURING SHOP TEST DEPLOYMENT, EMERGENCY EVACUATION SLIDE RAFT UPPER AND LOWER TUBES FOUND TORN. EMERGENCY EVACUATION SLIDE RAFT ROUTED TO VENDOR FOR REPAIR. (M)SDR 95UAL900038Tube · failedSLIDE RAFT WAS FOUND TO HAVE POROSITY ON THE LT BOTTOM TUBE, CROSS OVER TUBE, AND ON THE CENTER TUBE. IN ADDITION, SLIDE/RAFT HAS SEAM LEAKS ON THE RT AND LT SIDE TUBES. SCRAPPED SLIDE.SDR 95UAL900037Tube · failedSLIDE RAFT WAS FOUND TO HAVE POROSITY ON BOTH THE RT AND LT UPPER TOP TUBES AND IN BOTH ASPIRATOR TUBE AREAS. SCRAPPED SLIDE.SDR AALA951166Raft · scrappedLAX - DURING SHOP TEST DEPLOYMENT, LIFE RAFT FAILED LEAK CHECK DUE TO DEGENERATION OF FABRIC. SCRAPPED LIFE RAFT. (M)SDR AALA951165Raft · scrappedLAX - DURING SHOP TEST DEPLOYMENT, LIFE RAFT FAILED LEAK CHECK DUE TO LARGE AREA LEAK BETWEEN UPPER AND LOWER TUBES. SCRAPPED LIFE RAFT. (M)SDR USAA950721Nr 2 Aspirator · failedCLT - THE NR 2 ASPIRATOR ON LIFE RAFT, SERIAL NR TJ260 FAILED TEST. MAINTENANCE REPLACED THE SLIDE ASPIRATORS. OPERATIONS CHECKED GOOD. (W)SDR ASAA9580097Tether · detachedSEA - DURING LIFE RAFT DEMONSTRATION INFLATION, THE SURVIVAL EQUIPMENT PACKAGE BECAME DETACHED FROM THE RAFT WHEN THE TETHER SECURING THE EQUIPMENT PACKAGE TO THE RAFT STITCHING FAILED AT THE ATTACHMENT TO THE EQUIPMENT PACKAGE. THE RAFT WAS RETURNED TO THE MSDR 95ZZZX1943Life Raft · low pressureDURING AN INSPECTION OF LIFE RAFT BOTTLE PRESSURES, THE RAFT LOCATED IN THE OVERHEAD AT RIGHT OVERWING EXIT WAS FOUND TO HAVE ONE BOTTLE WITH LOW PRESSURE. THE RAFT WAS REMOVED AND A SERVICEABLE RAFT WAS INSTALLED.SDR TWRA9515Lower Tube · failedDURING A DITCHING DRILL EXERCISE, AT THE LONG BEACH RECREATION CENTER, THE 25 MAN LIFE RAFT (P/N 14D23041) USED DURING THE DRILL, FAILED TO DEPLOY PROPERLY. THE LOWER BUOYANCY TUBE FAILED TO INFLATE FULLY. THIS TYPE LIFE RAFT IS NOT INSTALLED ON ANY TOWER AISDR AALA950428Raft · defectiveLAX - DURING SHOP VISIT DEPLOYMENT, LIFE RAFT FOUND WITH HOLE IN UPPER TUBE BY ASPIRATOR. ROUTED LIFE RAFT TO VENDOR FOR REPAIR. (X)SDR AALA950427Raft · cutLAX - DURING SHOP VISIT DEPLOYMENT, LIFE RAFT HAD SMALL CUT BELOW ASPIRATOR. LIFE RAFT ROUTED TO VENDOR FOR REPAIR. (X)SDR HEEA954372Life Raft · defectivePHI REQUESTED THAT OUR EQUIPMENT BE BROUGHT UP TO FAR 135 STANDARDS, WITH SURVIVAL KIT INSTALLED. RAFT BULGES OUT AND DOES NOT FIT IN COMPARTMENT PROPERLY. ALSO THE BUTTON HALF OF THE CASE BELONGS TO A LEFT RAFT ASSEMBLY.
Back to JASC 2564