Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2015112446402Slide · out of positionL1 DOOR EMER EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR AALA20151121002Slide · bindingL1 CABIN DOOR DIFFICULT TO ARM OR DISARM. FOUND GIRT BAR APRON WAS BINDING. THE APRON WAS REPOSITIONED. WHILE PERFORMING ADDITIONAL TROUBLESHOOTING, THE SLIDE DEPLOYED SUCCESSFULLY. REPLACED THE L1 DOOR SLIDE.SDR SWAA2015112346321Slide · out of adjustL1 DOOR EMER EVAC SLIDE OUT OF ADJUSTMENT. ADJUSTED SLIDE IAW MM.SDR AALA201511209006Reservoir · inoperativeMID DOOR LT SLIDE PSI INDICATION INOPERATIVE. REPLACED 3L DOOR INFLATION RESERVOIR & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 25-62-49.SDR AALA201511209003Slide · low pressureR1 DOOR SLIDE SHOWS LOW PSI ON CIDS & SERVICING REPORT SLIDE GAUGE READS WELL WITHIN THE GREEN BAND, SLIDE PACK WERE RE-ARMED THIS SHIFT. REPLACED R1 DOOR SLIDE RAFT & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-00-710-801-A-01 & 25-62-41.SDR DALA2015120307373Slide · damagedLEFT OVERWING SLIDE LACING IS UNDONE. REMOVED UNSERVICEABLE SLIDE. INSTALLED SERVICEABLE LT OVERWING SLIDE IAW JIC 2560-9901-LT AND 5200-8346.SDR SWAA2015111946209Slide · looseL1 DOOR EMER EVAC SLIDE LOOSE FROM COVER. SECURED SLIDE IAW MT.SDR AALA201511199003D-Ring · out of positionL1 DOOR SLIDE D RING NOT VISIBLE. FOUND L1 DOOR MANUAL RELEASE D RING UNDER BUSSEL. MOUNTED OUTSIDE FRONT LOWER PART OF BUSSEL SO IT'S VISIBLE.SDR AALA20151118008Slide · partial deployAFTER LANDING & THE ACFT REACHED THE GATE, THE L1 DOOR WAS OPENED BY THE GATE AGENT & THE DOOR SLIDE PARTIALLY DEPLOYED. THE L1 DOOR ESCAPE SLIDE WAS REPLACED IAW MM 25-62-44.SDR SWAA2015111946231Slide · unsecureL1 DOOR EMER EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY. R & R SLIDE IAW MT.SDR AALA201511189005Fitting · faultyC1 CHECK, SLIDE FITTING 20DH FAILS OPERATIONAL TEST. REPLACED 20DH SLIDE FITTING IAW AMM 30-46-11-000-801-A & AMM 30-46-11-400-801-A. OPERATIONAL TESTED GOOD IAW AMM 30-46-000-710-801-A. ADJUSTED GIRT BAR FITTING IAW AMM 52-22-00-820-801-A.SDR AALA201511189004Fitting · faultyC1 CHECK, SLIDE FITTING 19DH FAILS OPERATIONAL TEST. REPLACED 19DH SLIDE FITTING IAW AMM 30-46-11-000-801-A & AMM 30-46-11-400-801-A. OPERATIONS TESTED GOOD IAW AMM 30-46-00-710-801-A. ADJUSTED GIRT BAR FITTING IAW AMM 52-22-00-820-801-A.SDR AALA201511189001Flap · interferenceCABIN DOOR 1L IS DIFFICULT TO ARM ITS SLIDE. FOUND GIRT FLAP FOLDED INCORRECTLY CAUSING INTERFERENCE WITH FLOOR. REFOLDED & STOWED. OPERATIONS TESTED GOOD IAW AMM 25-62-44.SDR IPXA2015111695859Cover · unsecureRIGHT ENTRY DOOR SLIDE COVER IS UNSECURE. RESEATED SLIDE COVER IAW AMM 25-23-07, REV 84.03 11/12/15.SDR IPXA2015111595814Pressure Switch · inoperativeR1 DOOR SLIDE REMOTE PRESSURE SWITCH INOPERATIVE. REF M564658, RELAMPED SWITCH WITH CORRECT BULBS AND REPLACED BATTERIES. OPS CHECK GOOD IAW AMM 25-61-04.SDR GTIA2015111501410Slide · faultedCREW REPORTED OVERWING SLIDES SHOW DISARMED. RE-ARMED ALL 4 EMERGENCY EXIT HATCH DOORS IAW AMM 52-21-11. OPS CK'S GOOD.SDR FDEA201511143604Slide · inoperativeR1 DOOR ESCAPE SLIDE PUSH TO TEST LIGHT WILL NOT EXTINGUISH. RELEASED FOR SERVICE IAW MEL 52-10-03-03, CATEGORY B, EXPIRATION 17 NOV 15. 1R MAIN ENTRY SLIDE & RAFT INOPERATIVE. TESTED SLIDE IAW FIM 25-61-02 PG 103 & MEL 25-61-02. SLIDE BOTTLE SHOWS GREEN,SDR HALA2015111400237Slide · no testEMERGENCY ESCAPE SQUIB TEST 1, RT SLIDE FAILS TEST. PERFORMED FIM 25-65, FAULT TREE 818, FIG 103A, STEPS 1-2-3-S3 AFTER CYCLING S617 AND S619. THE SYSTEM IS OK AND TEST GOOD, OK TO CONTINUE.SDR SWAA2015112346260Slide · unsecureR1 DOOR EMER ESCAPE SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW MT.SDR SWAA2015111846117Slide · out of positionR2 DOOR EMER EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR AALA201511139003Control Unit · failedC1 CHECK, 21DH CONTROL UNIT SLIDE FITTING HEAT G FAILS OPERATIONAL TEST. REPLACED SLIDE FITTING CONTROL UNIT 21DH & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 30- 46-000-8011-400-801A & 30-46-00-710-801-A.SDR DALA2015111307001Lanyard · damagedFOUND L1 DOOR SLIDE LANYARD UNSERVICABLE. REPLACED LANYARD.SDR AALA20151113004Slide · partial deployL4 DOOR OPENED FROM INSIDE WHILE ARMED. SLIDE PARTIALLY DEPLOYED. R & R THE L4 DOOR DAMPER CYLINDER DIAPHRAGM IAW AMM 52-22-00, LEAK CHECKED GOOD. R & R L4 DOOR ESCAPE SLIDE PACK IAW AMM 25-64-44. OPERATIONAL CHECKED GOOD. SEE ALSO AALA20151113008.SDR SWAA2015111346043Slide · out of adjustR1 DOOR EMER EVAC SLIDE GIRT BAR RETAINER OUT OF ADJUSTMENT. ADJUSTED SLIDE IAW SIP.SDR AALA201511169004Bottle · low pressureSLIDE 2R BOTTLE PRESS SHOWS LOW. REPLACED R2 DOOR SLIDE BOTTLE & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 25-62-49.SDR IPXA2015111195701Slide · looseSLIDE PACK HOUSING ON LT MAIN ENTRY DOOR IS LOOSE AT TOP FORWARD SIDE. REPOSITIONED LT ENTRY DOOR SLIDE PACK COVER, OPS CK NORMAL.SDR SWAA2015111145967Pin · looseR2 DOOR EMER EVAC SLIDE LATCH BLOCK ROLL PINS LOOSE. SECURED PIN IAW SIP.SDR SWAA2015111145970Slide · out of positionL1 DOOR EMER EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR AALA201511119001Slide · defective1S CHECK, UNABLE TO PROPERLY SECURE R2 SLIDE COVER TO SLIDE. INTERFERENCE FIT ISSUE. REPLACED R2 DOOR SLIDE IAW 26C84252006.SDR DALA2015111106871Slide · damagedQRO MAINTENACE FOUND THAT THE L1 DOOR SLIDE PACK LACING WAS MISSING. A NEW LACING WAS INSTALLED IAW AES PACKING INSTRUCTIONS.SDR SWAA2015111045946Slide · unsecureR1 DOOR EMER EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW MT.SDR SWAA2015111045945Slide · looseR2 DOOR EMER EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.SDR AALA20151110008Relay · not seatedOVERWING SLIDE SQUIB TEST 1, LT SLIDE FAILS. ACCOMPLISHED TROUBLESHOOTING IAW FIM 25-65-00 FIGURE 103 & MCM CARD 25-92-03. RESEATED TEST RELAYS M1135 K3 & K5. NOW CHECKS OK. SEE ALSO AALA20151110001.SDR AALA20151110001Relay · not seatedOVERWING SLIDE SQUIB TEST 1, LT SLIDE FAILS. ACCOMPLISHED TROUBLESHOOTING IAW FIM 25-65-00 FIGURE 103 & MCM CARD 25-92-03. RESEATED TEST RELAYS M1135 K3 & K5, NOW CHECKED OK. SEE ALSO AALA20151110008.SDR SWAA2015111045947Slide · unsecureR1 DOOR EMER EVAC SLIDE INADVERTENTLY FELL OUT OF CONTAINER, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW MT.SDR SWAA2015111045934Slide · out of positionR2 DOOR EMER EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW SIP.SDR DALA2015111006848Lanyard · frayedMAINTENANCE DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE AT L1 DOOR HAD A NON-SERVICEABLE FRAYED LANYARD. THIS COULD PREVENT PROPER DEPLOYMENT OF THE ESCAPE SLIDE AND IS NOT IN COMPLIANCE WITH 14 CFR PART 121.703. THE DOOR SLIDE LANYARD WAS REPLACED.SDR SWAA2015111045938Slide · out of positionR2 DOOR EMER ESCAPE SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR SWAA2015110945887Slide · unsecureR1 DOOR SLIDE INADVERTENTLY FELL OUT OF CASE, DID NOT DEPLOY, STILL OPERATIONAL. INSTALLED SLIDE IAW MT.SDR SWAA2015110645822Pin · bentL1 DOOR EMER EVAC SLIDE BLOCK ASSEMBLY PIN BENT. R & R PIN IAW SIP.SDR SWAA2015110645821Slide · unsecureL1 DOOR EMER SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW MT.SDR SWAA2015110645817Slide · looseR2 DOOR EMER EVAC SLIDE LOOSE. SECURED SLIDE IAW MM.SDR SWAA2015110645813Slide · out of positionL1 DOOR EMER EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR DALA2015110406715Bottle · low pressureMAINTENANCE FOUND AFT CABIN SERVICE DOOR EMERGENCY ESCAPE SLIDE PRESSURE LOW. THE SLIDE WAS REPLACED.SDR DALA2015110306665Lanyard · damagedMAINTENANCE DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE AT DOOR 1R HAD A NON-SERVICEABLE LANYARD. THIS COULD PREVENT PROPER DEPLOYMENT OF THE ESCAPE SLIDE AND IS NOT IN COMPLIANCE WITH 14 CFR PART 121.703. THE DOOR SLIDE GIRT BAR LANYARD WAS REPLACED.SDR DALA2015121107566Slide · damagedMAINTENANCE DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE AT DOOR 1L WAS DAMAGED, NOT SPECIFIED. THE DOOR SLIDE WAS REPLACED.SDR UIEA2015110300607Slide · deployedLEFT OVERWING SLIDE DEPLOYED ON GND. R & R SEVERAL COMPONENTS, ESCAPE SLIDE, SPOILER OVERRIDE ACTUATOR, SLIDE COMPARTMENT DOOR ACTUATOR LT AFT & LT FWD, INFLATION CYLINDER & SLIDE LATCH RELEASE ACTUATOR IAW AMM 25-65-11, 25-65-02, 25-65-20 & 25-65-01. REF LPSDR SWAA2015110445737Slide · out of positionL1 DOOR EMER EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW MT.SDR AALA20151103002Slide · unwanted deployDURING TROUBLESHOOTING, SQUIB TEST PROBLEM. LT WING OVERWING SLIDE DEPLOYED. REPLACED LT WING OVERWING ESCAPE SYS COMPONENTS.SDR FDEA201511023438Slide · malfunctionedUPON CLOSING DOORS FOR DEPARTURE FROM GATE, THE R1 DOOR WHEN CLOSED DID NOT INDICATE 2 GREEN. WHILE TRYING TO TEST DOOR, R1 WAS INADVERTENTLY OPENED & AFTER BEING ARMED, SLIDE PARTIALLY DEPLOYED. INSTALLED LIFE RAFT IAW MM CHP 25-61-24-04-01 AS REQUIRED. A
Back to JASC 2565