Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2014092900014Slide Raft · unserviceableTHE R2 DOOR SLIDE COVER IN CONTACT WITH FUSELAGE. R & R SLIDE RAFT IAW JOB CARD 26L00025011.SDR USAA2014100300010Slide · damagedLEASE RETURN CHECK. LEFT OFF WING SLIDE FWD DIAGONAL STRAP REINFORCEMENT HOOK BROKEN AT LOWER END. R & R SLIDE IAW AMM 25-65-05 PB 401. PARTS CHANGE INDICATED TT 8271263 SN OFF PG 0060 SLIDE, LT OFF WITH OFF 12-2561-9-0002 0060 ON 12-2561-9-0002 0016.SDR AALA20140926011Slide · unwanted deployLEFT OVERWING SLIDE DEPLOYED WHEN ARMING HANDLE, LT FWD HATCH WAS MOVED FROM SAFE TO ARMED POSITION. REPLACED LT OVERWING SLIDE.SDR SWAA2014092932367Slide · out of adjustL2 DOOR EMER EVAC SLIDE OUT OF ADJUSTMENT. ADJUSTED SLIDE IAW AMM & MT.SDR USAA2014092900018Reservoir · low pressureDOOR L2 EMER SLIDE RESERVOIR IS IN RED BAND. REPLACED DOOR L2 EMER SLIDE RESERVOIR IAW AMM 25-62-49-000.SDR SWAA2014092932368Fastener · missingR1 DOOR EMER EVAC SLIDE HARDWARE MISSING. INSTALLED HARDWARE IAW CMM.SDR DALA2014092505227Slide · detachedFOUND L2 DOOR SLIDE OFF MOUNT AND DOOR RESERVOIR PRESSURE ZERO. REINSTALLED ORIGINAL SLIDE AND REPLACED RESERVOIR IAW AMM 52-11.SDR HALA2014092400144Slide · failedR1 DOOR EPSU FAILS TO TEST. TRIED EPSU & BATTERY NO HELP-EPSU FAILS TO TEST, NO LEDS ILLUMINATING, IAW TSM 25-62-00-810-802-A. CHECKED SLIDE R1 LIGHT, PIN ENGAGEMENT AND CHECKED NORMAL, CYCLED AND NO HELP IAW TSM DISC SLICE C/P AND EPSU TESTED NORMAL. REQUIRSDR SWAA2014102733368Cable · disconnectedL1 DOOR SLIDE CABLE DISCONNECTED. R & R SLIDE ASSEMBLY IAW MM.SDR USAA2014092400003Clamp · missingTHE LT OVERWING SLIDE BOTTLE DISCHARGE HOSE IS MISSING CLAMP, SPACER WASHER & SCREW. ACCOMPLISHED TEMPORARY REPAIR IAW EA 208591. MX ACTION PENDING.SDR CALA2014092992322Line · chafedRIGHT OFF WING SLIDE PRESS LINE FOUND CHAFING WHERE IT PENETRATES FUSELAGE THROUGH CLOTH BRAID ON LINE. REPAIRED PRESS LINE GNMM 1-0-0-006.SDR SWAA2014092532305Slide · unsecureL1 DOOR EMER EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. RE-INSTALLED SLIDE IAW MT.SDR WX0A2014092572168Slide · deployedWHILE PERFORMING WORK CARD 25-831-002 DOOR ESCAPE SLIDE, L2 DOOR SLIDE ENGAGED & DEPLOYED. REMOVED L2 SLIDE IAW AMM 25-62-44-000-010-A. FOR SLIDE INSTALLATION REFERENCE WORK ORDER 00235140.SDR SWAA2014092432260Slide · low pressureR2 DOOR EMER EVAC SLIDE PRESS LOW. R & R SLIDE IAW MT.SDR DALA2014092405182Cover · wornR1 DOOR SLIDE COVER WORN ON BACK SIDE OF ATTACHMENT POINT. INSTALLATION OF NEW ESCAPE SLIDE ACCOMPLISHED ON TASK CARD.SDR SWAA2014092332217Slide · out of positionL2 DOOR EMER EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR SWAA2014092332207Slide · out of positionR2 DOOR EMER EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR SWAA2014092232187Slide · out of positionL1 DOOR EMER EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR AALA20140918008Slide · out of positionFLIGHT CREW FOUND THE FWD SERVICE DOOR SLIDE OUT OF THE NORMAL POSITION. SLIDE DID NOT DEPLOY & THE SLIDE HAD BEEN DISARMED. THE PACK FOR THE SLIDE WAS ATTACHED TO THE DOOR BUT DID NOT DEPLOY DUE TO THE GIRT BAR NOT BEING INSTALLED TO THE FLOOR FITTINGS. RESDR CALA2014091901263Slide · tornACFT LT REAR SLIDE HAS TEAR NEAR GIRT BAR. REPLACED SLIDE IAW AMM 25-66-01. ROTABLE PARTS CHANGE WAS INDICATED. TT 1647512 SN OFF 03373 SLIDE, OFF 29-2561-9-0004 3373 ON 29-2561-9-0004 3432.SDR DALA2014091805101Harness · tornR1 DOOR EMERGENCY ESCAPE SLIDE HARNESS IS TORN. INSTALLATION OF NEW HARNESS ACCOMPLISHED ON CARD 2040-0057-1R.SDR SWAA2014091832074Slide · out of adjustL1 DOOR EMER EVAC SLIDE OUT OF ADJUSTMENT. ADJUSTED SLIDE IAW MT.SDR SWAA2014091832108Slide · low pressureL1 DOOR EMER EVAC SLIDE PRESS LOW. R & R SLIDE IAW MT.SDR USAA2014091700009Slide · delaminatedS2 CHECK LT OVERWING SLIDE HAS DELAMINATION. REPLACED IAW JOB CARD 26C19053012.SDR SWAA2014091732070Slide · looseR1 DOOR EMER EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.SDR USAA2014091700002Slide · unsecureWHILE OPENING A DISARMED L2 DOOR THE SLIDE FELL OFF ONTO THE JET WAY WITH GIRT BAR STILL ATTACHED. REPLACED L2 DOOR ESCAPE SLIDE. THE L2 RESERVOIR ASSIST BOTTLE WAS ALSO REPLACED DUE TO DISCHARGING.SDR SWAA2014091832081Slide · looseL1 DOOR EMER EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.SDR SWAA2014091732071Slide · looseL2 DOOR EMER EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.SDR CALA2014091892238Slide · deployedDOOR 1R SLIDE DEPLOYED. REPLACED 1R DOOR SLIDE IAW AMM 25-62-44-000-002, CHECKED OK.SDR CALA2014091892237Slide · defectiveDURING EMER LIGHT TEST, GOT EPSU EXT LOAD FWD LT MSG. REPLACED DOOR SLIDES L1 & R1 IAW AMM 25-62-44-400. EMER LIGHT TEST PASSED.SDR USAA2014091500013Slide · low pressureR1 DOOR SLIDE PRESS LOW. REPLACED R1 DOOR SLIDE IAW JOB CARD 26L00025010.SDR GTIA2014091401418Pin · inoperativeR1 DOOR SLIDE REGULATOR SAFETY PIN WILL NOT ENGAGE. R & R R1 DOOR SLIDE ASSY.SDR SWAA2014091531982Slide · out of positionL2 DOOR SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR SWAA2014091531969Slide · unsecureL1 DOOR INADVERTENTLY FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW TASK CARD.SDR SWAA2014091531929Slide · looseL2 DOOR EMER EVAC SLIDE LOOSE. SECURED SLIDE IAW SIP.SDR SWAA2014091531920Slide · out of adjustL2 DOOR EMER EVAC SLIDE OUT OF ADJUSTMENT. ADJUSTED SLIDE IAW MT & AMM.SDR SWAA2014091531916Slide · unwanted deployR1 DOOR SLIDE INADVERTENTLY DEPLOYED DURING REMOVAL. R & R SLIDE IAW MM.SDR R61A201409081046Slide · damagedCREW REPORTED THAT THE L1 DOOR SLIDE WAS FALLING OUT THE DOOR. MAINTENANCE INSPECTED AND FOUND THE SLIDE PARTIALLY DEPLOYED WITH THE ASSIST BOTTLE ENGAGED. MAINTENANCE REPLACED THE SLIDE & DIAPHRAM IAW AMM, WITH NO LEAKS NOTED. ACFT IS GOOD FOR SERVICE.SDR CALA2014090992105Slide · damagedRIGHT OVERWING SLIDE PACK SKIN PEELING OFF. HONEYCOMB STRUCTURE VISIBLE. AREA APPROX 6 INCHES X 6 INCHES, SIGNS OF CORROSION. REPLACED RT OVERWING ESCAPE SLIDE IAW AMM 25-62-42. TESTED OK.SDR C77A20140906004Flap · gougedAFT SERVICE DOOR FWD EVACUATION SLIDE FLOOR FITTING EQ SLIDE FLAP IS GOUGED FROM GIRT BAR. R & R AFT SERVICE DOOR, FWD EVACUATION SLIDE FLOOR FITTING IAW AMM 53-23-21-000-804 & 53-23-21-400-804 ON WORK ORDER 8061732I3.SDR SWAA2014090931707Slide · out of positionL2 DOOR EMER EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MM.SDR USAA2014090800022Reservoir · low pressureL3 SLIDE RESERVOIR PRESS READS LOW. REPLACED L3 SLIDE RESERVOIR IAW AMM 25-62-49-000-001A & 25-62-49-400-001A.SDR SWAA2014091031788Slide · unsecureL1 DOOR EMER EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY. STILL OPERATIONAL. INSTALLED SLIDE IAW MT.SDR SWAA2014090931758Slide · unsecureL1 DOOR EMER EVAC SLIDE FELL OUT, DID NOT DEPLOY. R & R SLIDE MT.SDR SWAA2014090931695Slide · unsecureL1 DOOR EMER EVAC SLIDE FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. INSTALLED SLIDE IAW MT.SDR USAA2014090800026Slide Raft · unsecureL1 DOOR SLIDE FELL OUT OF PACK ASSEMBLY WHEN OPENING DOOR. REPLACED L1 DOOR RAFT SLIDE.SDR R61A201409051038Pin · misinstalledDURING OVERNIGHT MAINTENANCE, MECHANIC OPENED THE L1 DOOR WHILE IT WAS ARMED AND THE L1 DOOR SLIDE DEPLOYED, HOWEVER IT FAILED TO INFLATE. MAINTENANCE INSPECTED AND FOUND THE LOCKOUT PIN STILL INSTALLED. MAINTENANCE R & R THE L1 DOOR SLIDE IAW AMM AND OPS CSDR R61A201409051037Slide · openEMERGENCY EVAC SLIDE STARTED TO OPEN. MAINTENANCE R & R EMERGENCY EVAC SLIDE IAW AMM AND OPS CHECKED GOOD.SDR T7PY20141007001Housing · crackedDURING OVERHAUL OF EVACUATION SLIDES, A RUPTURE OF THE HOUSING ASSY IN THE INFLATION HOSE FITTING THAT RESULT ON THE DETACHMENT OF THE RESERVOIR AND VALVE ASSY OF THE RESERVOIR SLING AND EVASION OF THE ESCAPE SLIDE.SDR DALA2014090304942Slide · low pressureTAIL CONE LIFE RAFT PRESSURE LOW. R & R TAILCONE SLIDE IAW AMDS CARD 2561-4643.
Back to JASC 2565