What was found
FOUND L2 DOOR SLIDE OFF MOUNT AND DOOR RESERVOIR PRESSURE ZERO. REINSTALLED ORIGINAL SLIDE AND REPLACED RESERVOIR IAW AMM 52-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND L2 DOOR SLIDE OFF MOUNT AND DOOR RESERVOIR PRESSURE ZERO. REINSTALLED ORIGINAL SLIDE AND REPLACED RESERVOIR IAW AMM 52-11.