Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20130923017Terminal · brokenBOTH LT & RT EMERGENCY ESCAPE SQUIB TEST 1 SLIDE & SQUIB TEST 2 SPOILER FAILED. FOUND A BROKEN WIRE TERMINAL FROM RT SIDE BATTERY PACK. R & R TERMINAL. OPERATIONS CHECKED NORMAL.SDR DALA13046840962Bottle · dischargedMX DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE INFLATION BOTTLE AT L2 DOOR DEPLETED. T THE DOOR SLIDE INFLATION BOTTLE WAS REPLACED.SDR SWAA2013100320762Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR SWAA2013093020575Pin · missingR1 DOOR EMERGENCY EVAC SLIDE SAFETY PIN MISSING. INSTALLED PIN IAW AMM.SDR SWAA2013092420442Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR SWAA2013092320375Slide · low pressureL1 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. R & R SLIDE IAW MM & MT.SDR FDEA201309212278Battery · inoperativeDURING SERVICE CHECK, FOUND PUSH TO TEST LIGHT ON R1 DOOR SLIDE REMOTE INDICATOR INOP. R & R PUSH TO TEST LIGHTS. NO HELP. REPLACED 2C BATTERYS ON DOOR SLIDE, OPS CHECKED DOOR IAW MM 25-61-04-4.SDR DALA13046400979Slide · out of positionINSPECTION DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE COVER FOR TAILCONE WAS NO LONGER IN AN ACCEPTABLE CONFIGURATION. AN OUT OF POSITION, MISRIGGED, POOR CONDITION, OR ILL-ARRANGED SLIDE ASSEMBLY COULD PREVENT PROPER DEPLOYMENT OF THE ESCAPE SYS AND IS NOT ISDR R61A201309200892Slide · partial deployL1 DOOR WAS OPENED BEFORE F/A COULD DISARM DOOR, CAUSING THE PARTIAL DEPLOYMENT OF THE SLIDE. ACFT FERRIED, WHERE THE SLIDE WAS R & R IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.SDR FDEA201309192249Socket · misinstalledON POST FLIGHT CHECK, R1 DOOR EVACUATION SLIDE PTT LIGHT WILL NOT TEST. FOUND R1 DOOR SLIDE REMOTE PRESS TO TEST SOCKET CLOCKED IMPROPERLY. CLOCKED PER MM 25-61-04-4 AND OPS CHECKED GOOD IAW MM 25-61-04-5. OK FOR SERVICE.SDR SWAA2013092320328Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. R & R SLIDE IAW AMM & MT.SDR SWAA2013091920287Retaining Ring · out of positionL1 DOOR EMERGENCY EVAC SLIDE RETAINING PIN OUT OF POSITION. R & R SLIDE IAW MM.SDR UHLA2013091800427Slide · damagedL1 DOOR SLIDE CAME UNLACED AND ASSIST BOTTLE AT 0 PSI. R & R L1 DOOR SLIDE IAW AMM 25-65-01, INSTALLED NEW DIAPHRAGM AND SHEAR PIN IAW AMM 52-11-53. SERVICED DOOR, OPS CHECKED GOOD.SDR SWAA2013092320372Slide · out of adjustR1 DOOR SLIDE EMERGENCY EVAC SLIDE OUT OF ADJUSTMENT. ADJUSTED SLIDE IAW AMM.SDR SWAA2013092320327Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUSTMENT. ADJUSTED SLIDE IAW MT.SDR SWAA2013091820211Slide · unwanted deployL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY DEPLOYED UPON INITIAL DOOR OPENING. R&R SLIDE IAW MT.SDR SWAA2013092620503Pin · missingL1 DOOR EMERGENCY EVAC SLIDE SAFETY PIN MISSING. INSTALLED PIN IAW AMM.SDR WX0A201309260002Slide · splitL1 DOOR SLIDE DEPLOYED, FAILED TO INFLATE, SEAM FOUND SPLIT. REPLACED L1 DOOR SLIDE IAW CARD R0902502.SDR SWAA2013091820212Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW SIP.SDR DALA13045321708Battery Pack · inoperativeOVERWING SQUIB SLIDE TEST LT FAILED. CHANGED BATTERY OF THE EMERGENCY BATTERY PACK IAW TASK 25- 65-17, OK FOR SERVICE.SDR DALA1318200635Bottle · inoperativeEMERGENCY ESCAPE SLIDE RT ILLUMINATED ON P61 PANEL. REPLACED OVERWING EMERGENCY ESCAPE SLIDE INFLATOR.SDR DALA13045289223Slide · looseDURING TAIL CONE DROP, AFT ESCAPE SLIDE CAME UNPACKED. REPLACED AFT ESCAPE SLIDE IAW WC 2500-4332 & AMM 53-52-01-420-801.SDR R61A201309150875Slide · unwanted deployF/A OPENED THE L1 DOOR BEFORE DISARMING THE ESCAPE SLIDE, CAUSING IT TO FALL OUT INTO THE JETWAY. MX R & R THE L1 SLIDE AND RESERVICED THE ASSIST BOTTLE IAW AMM. OPS CHECKED GOOD.SDR DALA1318210635Elbow · brokenFOUND LT OVERWING SLIDE INFLATION LINE ELBOW BROKEN. REPLACED SLIDE INFLATION LINE ELBOW IAW AMM 25-65.SDR C77A20130917001Slide · dislodgedL1 FWD ENTRY DOOR ESCAPE SLIDE FELL OUT FROM BUSTLE AFTER REPOSITIONING ACFT FROM GATE TO REMOTE PARKING WHEN DOOR WAS OPENED. CONTRACT MX DETERMINED DOOR WAS ARMED WHEN OPENED, ESCAPE SLIDE FAILED TO DEPLOY. ADDITIONAL INFORMATION SUGGESTS THAT "UPON OUR ARSDR FDEA201309122200Indicator · inoperativeDURING PREFLIGHT, FOUND LEFT ENTRY DOOR EVACUATION SLIDE REMOTE PRESSURE PRESS-TO-TEST INDICATING SYS LIGHT INOPERATIVE. REMOVED AND REPLACED THE L1 DOOR PRESSURE INDICATOR ASSY, OPS NORMAL.SDR FDEA201309122185Battery Pack · dischargedR1 DOOR PRESS-TO-TEST LIGHT DIM. R & R SLIDE BATTERIES. SYS OK FOR SERVICE. FINAL CLOSED.SDR SWAA2013081920258Slide · unsecureL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY STILL OPERATIONAL. RESTORED SLIDE IAW MT.SDR SWAA2013092320330Slide · faultyR1 DOOR EMERGENCY EVAC SLIDE FAULTY. R & R SLIDE IAW AMM.SDR SWAA2013092320322Pin · missingL1 DOOR EMERGENCY EVAC SLIDE MISSING SAFETY PIN. INSTALLED PIN IAW AMM.SDR USAA2013091200001Harness · rottedHARNESS ASSY FOR L1 DOOR SLIDE DRY ROTTED. HARNESS ASSY REQUIRES REPLACEMENT. MX INST SERV L1 DOOR SLIDE APRON HARNESS.SDR GTIA20130909959Reservoir · low pressureMAIN DOOR OPENING INDICATE CHECK SLIDE PRESSURE AMBER RIGHT OVERWING EXIT. R & R RIGHT OVERWING ESCAPE SLIDE RESERVOIR IAW TSM AND AMM. OPS CK GOOD.SDR SWAA2013091120063Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR USAA2013091000001Slide · inoperativeR1 DOOR SLIDE WONT ARM CORRECTLY. SLIDE ASSY REPLACED.SDR CALA2013090991136Slide · deployedDOOR 2R SLIDE DEPLOYED AT GATE. R&R R2 DOOR SLIDE IAW AMM, GROUND CHECKED GOOD.SDR USAA2013090900024Bottle · low pressureCHECK SLIDE PRESSURE DISPLAYED ON CIDS PANEL FOR L2 DOOR. R & R L2 SLIDE DOOR INFLATION BOTTLE IAW AMM 25-62-49.SDR USAA2013090900004Cylinder · depletedWHILE ACCOMPLISHING INSPECTION, FOUND LT OVERWING SLIDE BOTTLE PRESSURE BELOW MINIMUM. R & R LT OVERWING SLIDE INFLATION CYLINDER.SDR USAA2013090900003Cylinder · depletedWHILE ACCOMPLISHING INSPECTION, FOUND RT OVERWING SLIDE BOTTLE BELOW MINIMUM. R & R RT OVERWING SLIDE INFLATION CYLINDER. R & R RT BOTTLE INFLATION HOSE DUE TO DAMAGE.SDR FDEA201309072151Battery · failedESCAPE SLIDE TEST LIGHT INOPERATIVE. REMOVED SLIDE COVER IAW AMM 25-61-01-2 AND REPLACED BATTERIES FOR SLIDE BOTTLE PRESSURE LIGHT. OPS CHECKED NORMAL IAW AMM 25-61-03-5. OK FOR SERVICE.SDR SWAA2013091020049Slide · low pressureL1 DOOR EMERGENCY EVAC SLIDE LOW PRESSURE. R&R SLIDE IAW MT.SDR SWAA2013090919960Slide · failedR2 DOOR EMERGENCY EVAC SLIDE FAILED FUNCTIONAL CHECK. R&R SLIDE IAW AMM & MT.SDR SWAA2013090919946Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUSTMENT. ADJUSTED SLIDE IAW MT.SDR SWAA2013090619894Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. R&R SLIDE IAW MT.SDR SWAA2013090519865Slide · unsecureL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. SECURED SLIDE IAW MT.SDR AALA20130912006Slide · damagedDURING PREFLIGHT, FOUND GIRT BAR AT SERVICE DOOR OUT & PINS EXPOSED. FOUND ALL PINS PULLED OUT OF SLIDE & GIRT BAR HANGERS BENT DOWN. REPAIRED HANGERS & REPLACED SLIDE ASSEMBLY.SDR SWAA2013090619923Slide · looseR2 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW MM.SDR IPXA3M80150Pressure Switch · inoperativeDURING PDC, L1 DOOR SLIDE LOW PRESSURE SWITCH INOPERATIVE. REPLACED L1 EVAC SLIDE PER AMM 25-61-15-401. OPS CHECKED GOOD.SDR USAA2013090400001Slide · no testL3 SLIDE FAILED OPS CHECKED, SLIDE JAMMED DOOR PART OPENED. MX R & R L3 DOOR SLIDE/RAFT PACK ASSY.SDR USAA2013090300019Reservoir · low pressureCIDS PANEL SHOWS RIGHT OVERWING ESCAPE SLIDE BOTTLE PRESSURE LOW. R & R INFLATION RESERVOIR IAW AMM 25-62-46-000-001-A.SDR DALA1317960613Slide · low pressureINOPERATIVE EMERGENCY SLIDE BOTTLE HAS LOW PRESSURE. R & R SLIDE IAW JIC 7809.
Back to JASC 2565