Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2013101421156Slide · out of positionL2 DOOR SLIDE EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR DALA13051839000Lanyard · disconnectedPILOT REPORTED THE FWD GALLEY DOOR SLIDE COVER LANYARD HAD BECOME DISCONNECTED. MX REATTACHED THE LANYARD TO A SERVICEABLE CONDITION.SDR USAA2013101000001Slide · dislodgedSTRAP HANGING OUT OF 2L DOOR. R & R 2L DOOR SLIDE.SDR GTIA201310151004Cable · damagedFWD RT DOOR ESCAPE SLIDE ARM/DISARM FLEXIBLE CABLE HAS BURST/TORN SHEATH. R & R RT DOOR ESCAPE SLIDE CABLE IAW AMM 52-11-22 AND OPS CHECK GOOD IAW AMM 25-62-44.SDR GTIA201310151002Cable · damagedFWD LT DOOR ESCAPE SLIDE ARM/DISARM FLEXIBLE CABLE HAS BURST/TORN SHEATH. R & R FWD LT DOOR ESCAPE SLIDE CABLE IAW AMM 52-11-22. OPS CHECK GOOD IAW AMM 25-62-44, WORK CLEARED ON NON-ROUTINE 7240N00505.SDR DALA13051230927Toggle · failedACFT FAILED THE FUNCTIONAL CHECK OF TAILCONE RELEASE SYS WHEN A WORN TOGGLE ON THE SLIDE LANYARD PREVENTED THE SLIDE FROM DEPLOYING. THE TOGGLE WAS REPLACED, THE SYS WAS RETURNED OPERATIONAL STATUS, AND THE RII WAS COMPLETED.SDR KCSA20131080012Battery Pack · failedON TERMINATING SERVICE CHECK, LT ESCAPE DOOR BATTERY CHECK FAILED. R & R BATTERY PACK IAW MM 52-23-14. OPS CHECKED GOOD.SDR GTIA201310151003Cable · damagedAFT RT DOOR ARM, DISARM FLEXIBLE CABLE HAS BURST. R & R AFT RT DOOR ARM, DISARM CABLE IAW AMM 52-13-22. OPS CHECK GOOD IAW AMM 25-62-44. CLEARED ON NON-ROUTINE 7240N00498.SDR DALA13050769011Lanyard · brokenAFTER ARRIVAL, PILOT REPORTED L1 DOOR ESCAPE SLIDE LANYARD WAS FOUND TO BE BROKEN. THE LANYARD WAS REPLACED.SDR SWAA2013100820968Slide · low pressureL2 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. R & R SLIDE IAW MT.SDR GTIA20131005990Bottle · low pressureLT AFT L2 SLIDE RESERVOIR PRESSURE GAUGE SHOWS AT BORDER LINE. R & R IAW AMM 25-62-44-000-012-A & 25-62-44-400-007-A. OPS CHECKED GOOD.SDR SWAA2013112222725Slide · crackedL1 DOOR ESCAPE SLIDE GIRT HAS CRACKED PLASTIC SLEEVE AT AFT END. R & R SLIDE ASSEMBLY IAW MT.SDR DALA13049450997Gauge · obstructedDURING SCHEDULED CHECK, THE TAILCONE SLIDE PRESSURE GAUGE WAS FOUND TO BE OBSTRUCTED FROM VIEW BY TAPE. TAILCONE SLIDE COVER WAS REPLACED IAW AMM 25-62-01 AND WC 2500-4484. REQUIRED INSPECTION COMPLETED.SDR R61A201310030991Screw · corrodedDURING HEAVY CHECK, FWD PASSENGER DOOR FLEX BALL HARDWARE CORRODED. MX R & R SLIDE ARM HANDLE LOWER HARDWARE IAW AMM 20-10-01, 20-10-02.SDR R61A201310030990Bolt · corrodedDURING HEAVY CHECK, L1 DOOR LOWER EVACUATION SLIDE HARDWARE CORRODED. R & R SLIDE HARDWARE IAW AMM 20-10-01, 20-10-02.SDR USAA2013100400003Actuator · low pressureR3 DOOR SLIDE SHOWS LOW PRESSURE. SERVICED DOOR ASSIST ACTUATOR IAW MM 52-10-00-614-001.SDR C77A20131004001Cable · bindingL2 DOOR IS DIFFICULT TO ARM & DISARM. R & R L2 DOOR EMERGENCY EVAC SLIDE MECHANISM FLEXBALL CABLE IAW AMM 52-12-40. OPS TEST GOOD.SDR R61A201310020993Bolt · corrodedDURING HEAVY CHECK, L-1 DOOR SLIDE ARMING HANDLE LOWER BOLT BOTH BOTTOM SLIDE HOOK ATTACH BOLTS FOUND TO HAVE CORROSION. MX R & R SLIDE ARMING HANDLE LOWER BOLT BOTH BOTTOM SLIDE HOOK ATTACH BOLTS IAW AMM 20-10-01, 20-10-02. PN NAS660-4D11, BOLT. ACFT REMAISDR R61A201310020986Screw · corrodedDURING HEAVY CHECK, L2 DOOR SLIDE TELFLEX CABLE FWD BELL CRANK ATTACH HARDWARE CORRODED. MX R & R L-2 DOOR SLIDE TELFLEX CABLE FWD BELL CRANK HARDWARE. PN NAS1154-100, SCREW. ACFT REMAINS UNTIL COMPLETION OF HEAVY CHECK.SDR SWAA2013100720802Slide · looseR2 DOOR EMERGENCY EVAC SLIDE LOOSE. R & R SLIDE IAW TC.SDR CALA2013100200720Slide · out of positionSLIDE PACK FELL OUT AT L2. IAW AMM 25-66-01-404-044, INSTALLED NEW ESCAPE SLIDE DOOR 2L. ROTABLE PARTS CHANGE WAS INDICATED TT 1570726 SN OFF 04505 SLIDE, B757-200 OFF 19-2520-9-0001 0810 ON 19-2520-9-0001 0736.SDR R61A201310010943Shear Pin · bentDURING FUNCTIONAL CHECK OF THE R1 DOOR SLIDE THE DOOR ASSIST DID NOT FIRE. MX FOUND THE ARM THAT HITS THE SHEAR PIN IS BENT. MAINTENANCE REPLACED THE PNEUMATIC DOOR ASSIST BOTTLE PER AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.SDR SWAA2013100220701Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR CALA2013093091583Bottle · faultyEMERGENCY ESCAPE SLIDE SQUIB TEST 2R BULB DOES NOT ILLUMINATE. DUE BOTTLE PRESSURE NOT WITHIN SERVICEABLE LIMITS. JUMPED BOTTLE PRESSURE SW CONN D5542 PINS A-C & TEST 2 CHECKED GOOD. SSM 25-65-01. NEED TO REPLACE RT OFF WING SLIDE BOTTLE & NEC TO DISARM OFF SDR KCSA20130930010Link · out of alignmentLT FLOOR MOUNTED ESCAPE SLIDE DEPLOYMENT LINK OUT OF ALIGNMENT. ADDED SHIMS TO ALIGN SLIDE DEPLOYMENT LINK WITH SLIDE DEPLOYMENT HOOK IAW AMM 25-68-01. OPS CHECK GOOD ON LT FLOOR MOUNTED ESCAPE SLIDE.SDR CALA2013093091595Housing · crackedLEFT OVERWING SLIDE DISCONNECT HOUSING ARM IS CRACKED IAW OFF WING ESCAPE COMPARTMENT DOOR LATCH INSPECTION CHECK. REPLACED LT OVERWING SLIDE DISCONNECT HOUSING ARM IAW AMM 25-65-98. OPS CHECKED GOOD.SDR SWAA2013100220673Slide · looseR1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.SDR YYFA20130929001Slide · unwanted deployWHEN OPENING L2 DOOR TO CLEAN TRASH FROM GALLEY THE DOOR SLIDE WAS DEPLOYED. R & R L2 DOOR SLIDE IAW MM 25-62-00.SDR SWAA2013100120600Slide · low pressureR1 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. R & R SLIDE IAW MT.SDR SWAA2013100120579Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR DALA13048120908Cover · damagedINSPECTION DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE IN THE TAILCONE HAD A COVER THAT WAS MISSING CRITICAL MATERIALS AND WAS NO LONGER IN AN ACCEPTABLE CONFIGURATION. THE ABSENCE OF THIS VELCRO ASSY COULD PREVENT PROPER DEPLOYMENT OF THE ESCAPE SYS AND IS NOTSDR DALA13048110908Cover · deterioratedINSPECTION DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE COVER IN THE TAILCONE HAD CRITICAL MATERIALS IN A DETERIORATED CONDITION. TAILCONE SLIDE COVER WAS REPLACED.SDR DALA13048050908Strap · misroutedINSPECTION DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE IN THE TAILCONE WAS NO LONGER IN AN ACCEPTABLE CONFIGURATION. THE SLIDE PULL STRAP WAS NOT PROPERLY ROUTED OR RIGGED. A MISRIGGED OR ILL-ARRANGED SLIDE ASSY WOULD PREVENT PROPER DEPLOYMENT OF THE ESCAPE SSDR SWAA2013100220675Pin · missingL1 DOOR EMERGENCY EVAC SLIDE PINS MISSING. R & R SLIDE IAW MM.SDR SWAA2013100120592Slide · low pressureR1 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. R & R SLIDE IAW MT.SDR SWAA2013100120578Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR SWAA2013100120647Slide · looseR1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.SDR USAA2013093000025Bottle · low pressureR3 DOOR SLIDE PRESSURE MESSAGE. SERVICED DOOR SLIDE BOTTLE IAW AMM 52-10-00-614-001-A.SDR FDEA201309272328Bulb · burned outSLIDE LIGHT ON L1 DOOR IS BURNED OUT. R & R BULB IAW SMP. LIGHT OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR CALA2013100391705Slide · unsecureRT SIDE SLIDE PACK WAS FOUND UNLACED. R & R RT OVERWING SLIDE PACK IAW AMM 25-65-01.SDR SWAA2013092620510Slide · looseL1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW AMM.SDR SWAA2013093020553Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT ADJUSTMENT. ADJUSTED SLIDE IAW MT.SDR USAA2013092600006Slide · unsecureCREW REPORTED AN ORANGE FLAG PROTRUDING FROM SLIDE COVER ON FWD ENTRY DOOR. MX INSPECTED L1 DOOR SLIDE AND RESECURED. ACFT OK FOR SERVICE.SDR DALA13047090956Cable · frayedMX DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE AT DOOR 1R HAD A FRAYED CABLE. A FAILURE OF THIS CABLE WOULD PREVENT PROPER DEPLOYMENT OF THE ESCAPE SLIDE AND IS NOT IN COMPLIANCE WITH 14 CFR, PART 121.703. THE DOOR SLIDE CABLE WAS REPLACED.SDR GTIA20130924981Slide · failedL4 DOOR SLIDE UNRAVELED/DEPLOYED. R & R L4 SLIDE PACK IAW AMM. OPS CHECKED OK IAW W/O 67765, ELEMENT NR 1.SDR YENA20130924202Diaphragm · failedDURING HEAVY MX CHECK, FOUND AT OPS CHECK, AFT SERVICE DOOR EMERGENCY SLIDE FAILED TO OPEN. REPACKED PNEUMATIC ASSY. REMOVED & REPLACED DIAPHRAGM.SERVICED AND PERFORMED EMERGENCY EVACUATION SLIDE MECHANISM OPS TEST IN REF TO E190 AMM 52-42-40,52-42-51,52-42-SDR DALA13047177001Battery Pack · inoperativeDURING L3 DOOR SLIDE DEPLOYMENT EPAS SYS FAILED TO OPERATE. SYS TESTED IAW AMM 52-11-20. OPS CHECKED GOOD. REMOVED AND INSTALLED SERVICABLE EPAS RESERVIOR IAW AMM 52-11-22. OPS CHECKED GOOD. REPLACED EPAS RESERVOIR IAW AMM 52-11-22, PB 401 SYS TEST NOSDR SWAA2013092520486Slide · looseR1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.SDR SWAA2013092620530Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR SWAA2013092420443Slide · looseL1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.
Back to JASC 2565