Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202507025869Slide · no testAIRCRAFT WAS GROUNDED: FORWARD LEFT SLIDE IS FAILING THE EMERGENCY POWER SUPPLY UNIT SYSTEM TEST. MAINTENANCE REPLACED THE L1 DOOR SLIDE ASSEMBLY PER TASK CARD 26L00025010 (AALA202507025869). IN ADDITION MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 10WL (ASDR CALA2025070706245Slide · no discrepancyDOOR R2 ESCAPE SLIDE PRESSURE GAGE IS IN RED. ON THE HIGH SIDE FOUND NEEDLE TO WITH WITHIN 1 NEEDLES WITH TO THE RIGHT OF GREEN BAND PER AMM 25-66-01-200-801 DUE TO SLIDES INFLATION CYCLINDER NOT BEING AT A STABLE TEMP FOR MORE THEN 2 HOURS. 52 MINS ON THE GROSDR AALA202507043323Slide Raft · low pressureAIRCRAFT WAS GROUNDED: SLIDE DEPLOYMENT BOTTLE AT DOOR 2R APPEARS IN THE RED. MAINTENANCE REPLACED AFT RIGHT (842) ESCAPE SLIDE/RAFT PER J/C #26L00025011.SDR CALA2025070306185Slide · faultySLIDE PACK AT DOOR 2L HAS LOW PRESSURE. PERFORMED VISUAL OF DOOR MOUNTED ESCAPE SLIDE 2L TO BE IN THE MIDDLE OF THE RED BAND IN REF MM 25-66-01-02B-300C. REMOVED AND REPLACED DOOR L2 SLIDE ASSY REF AMM 25-66-01. ACCOMPLISHED RII INSP REQUIREMENTS FOR DOOSDR CALA2025070306184Slide · low pressureDOOR 4L SLIDE PRESSURE GAUGE OUT OF GREEN BAND. REMOVED AND REPLACED DOOR 4L ESCAPE SLIDE IAW AMM REF TASK 25-66-01-000-801 & TASK 25-66-01-400-801.SDR CALA2025070306181Slide · no discrepancyDOOR 4R SLIDE PACK REMOVED FOR ACCESS IAW DMC-B787-A-25-66-01-01B-520A-A. RENDER SAFE CHECKLIST FOR DAY ONE 1ST JULY 2025. DOOR 4R SLIDE PACK INSTALLED IAW DMC-B787-A-25-66-01-01B-720A-A. EVACUATION SLIDE RII COMPLETED REF GMM 09-25-05. INSPECTION VISUAL CHECSDR AALA202507026496Slide · dislodgedAIRCRAFT WAS GROUNDED: WHEN THE FLIGHT ATTANDENT WENT TO OPEN THE ENTRY DOOR, THE GIRT BAR CAME OUT OF THE BRACKET AND APPEARED THAT THE SLIDE PARTIALLY CAME OUT. REMOVE AND REPLACE L1 DOOR SLIDE. PER J/C 09L20025004. OPERATIONAL CHECK GOOD.SDR IPXA2025070105651Slide · no discrepancyUNABLE TO ARM SLIDE AFTER CLOSING DOOR ADJUSTED GIRT BAR ASSEMBLY REF AMM 25-61-21. DOOR OPERATES CORRECTLY AT THIS TIME. DEFERRAL CLEARED PLACARDS REMOVED.SDR CALA2025070306179Slide · no discrepancyDOOR 2L FA REPORTS SLIDE PRESSURE AT THE GREEN MEETS RED LINE. INSPECTED DOOR 2L SLIDE PRESSURE GUAGE IAW AMM TASK 25-66-01-200-801. SLIDE IND IS WITHIN THE GREEN AND NORMAL AT THIS TIME. A/C OKAY TO CONTINUE.SDR CALA2025070106118Skirt · unsecureEMERGECY SLIDE SKIRT HAS ABOUT 2 FEET EXTRA HANGING OUT ON DOOR 1R. SECURED ECSESS MATERIAL. SECURED ECSESS MATERIAL. ADD EMP:V948178SDR CALA2025070106117Slide · no discrepancySLIDE RAFT HANGING LOW AT 1R DOOR INSPECTED R-1 GIRT MATERIAL AND FOUND TO BE WITHIN LIMITS REF AMM 25-66-01.SDR SWAA2025063086710Slide · detachedAFT EMERGENCY DOOR DOOR EXIT SLIDE; CAPTS SIDE; DETACHED FROM DOOR CASE <[01]. RE-INSTALLED L2 DOOR SLIDE IAW AMM 25-66-01 AND MT 725-61-06.SDR SIMA20250628001Slide · detachedL1 SLIDE FELL OFF DOOR AND IS SITTING IN FRONT GALLEY "TRANSFERRED TO NRWC 763-ORD-02614 ITEM-1" REPLACED EMERGENCY EVACUATION SLIDE IAW 25-65-01. NO DEFECTS NOTEDSDR CALA2025070106113Slide · faultedACFT L OVERWING SLIDE BLOWN. REMOVED SLIDE FROM ACFT. BLOWN SLIDE PLACED IN AFT CARGO. ALL MX DONE IN REF WITH AMM 25-62-42/401 CONFIG 00 PARTS TRANSACTION ROTABLE PARTS CHG:TT # 1480754 SN OFF 4281 PN OFF 31-2561-9-0001.IPC REFERENCE # MFG SN OFF NOT ON AC M&SDR CALA2025070106112Slide · faultedEMERGENCY SLIDE DOOR 2R BAD FROM STOCK. REMOVED DOOR 2R SLIDE REF AMM 25-62-44-000-802-A UP TO AND INCLUDING STEP A 4,G. COMPLETED REMOVAL OF SLIDE PER AMM 25-62-44-000-802-A. SN A6692. REQUESTING INSPECTION VERIFICATION FOR ELECTRICAL WIRING ROUTING AND GIRTSDR CALA2025070106110Slide · no discrepancyACCOMPLISHED THE REMOVAL OF THE R2 ESCAPE SLIDE IN REF WITH AMM TASK 25-62-44-000-802-A. AND RENDER A SAFE CHECK LIST. COMPLETED THE INSTALLATION OF THE R2 ESCAPE SLIDE IN REF WITH AMM 25-62-44-400-802-A. OPS CHECK GOOD. ACCOMPLISHED INSTALLATION INSPECTION OFSDR SWAA2025063086368Slide · dislodgedFORWARD ENTRY DOOR SLIDE FELL OUT OF BOX<[01] REINSTALLED FWD ENTRY DOOR ESCAPE SLIDE IN THE COMPARTMENT AND THE COMPARTMENT ASSEMBLY PER MT 725-61-06 & AMM 25-66-01.SDR CALA2025063006055Slide · out of position2R SLIDE MATERIAL STICKING OUT AT BOTTOM ADJUSTED DOOR 2R SLIDE FLAP TO NML. REF AMM25-66-01-400-803SDR CALA2025063006051Slide · no discrepancyDOOR-MOUNTED ESCAPE SLIDE PACK ASSEMBLY REMOVAL - AT DOOR 2 RH S/N 8707, VERIFIED CORRECT SLIDE NUMBER AND EFFECTIVITY. REF IPC 25-66-01. COMPLIED WITH GMM 09-25-05 REMOVED AND REPLACED DOOR 2R ESCAPE SLIDE PER AMM 25-66-01.SDR CALA2025063006050Skirt · out of positionSLIDE MATERIAL DOOR 1R PROTRUDING OUT BOTTOM OF SLIDE HOUSING REPOSITIONED SKIRT. REF AMM 25-66-01-401. OK FOR SERVICE. ABOVE ITEM IS RII ITEM. VERIFIED R1 DOOR SLIDE INSTALLATION PER REF AMM 25-66-01-401. L/P CLEAREDSDR DALA2025070104903Slide · no discrepancyLH OWEED SLIDE REQUIRES DEPLOYMENT REF AMDS 2561-9101. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0402:2561-9101/001 00003 DEPLOYED SLIDE PER AMDS 2561-9005 STEP 1-4. SLIDE INSTALL WILL BE COMPLETED ON THE REMAINDSDR DALA2025070104895Slide · no discrepancyRH OWEED SLIDE REQUIRES DEPLOYMENT REF AMDS 2561-9101. DEPLOYED SLIDE PER AMDS 2561-9006 STEP 1-4. SLIDE INSTALL WILL BE COMPLETED ON THE REMAINDER OF AMDS 2561-9006. (LP# 1047913)SDR AALA202506303427Slide · low pressureAIRCRAFT WAS NOT GROUNDED: WHILE WORKING A-CHECK 024 JOB CARD 08C20025006 DVI EMERGANCY ESCAPE SLIDE AND PRESSURE BOTTLE, FOUND AFT RIGHT DOOR SLIDE INFLATION CYLINDER PRESSURE GAGE IN THE RED. REMOVE AND REPLACE R2 SLIDE.PER W/C 08L22125001.SDR CALA2025063006047Slide · no discrepancyDOOR 2L WAS OPENED FROM THE OUTSIDE WHILE ARMED. DOOR DISARMED ITSELF. PERFORMED INSPECTION OF 2L DOOR AND SLIDE PACK, NO DEFECTS, CONFIRMED SLIDE WAS DISARMED AS DOOR WAS OPENED FROM EXTERIOR. RAN THROUGH OPERATION OF DOOR YEILDING SUCCESSFUL FUNCTION. OKAY SDR CALA2025063006045Slide · no discrepancy1L DOOR SOUNDS LIKE THE SLIDE IS LOOSE AND BANGING AROUND PERFORMED ESCAPE SYSTEM CHECK I.A.W AMM REF: 25-66-01-206-001. VERIFIED SLIDE AND BUSTLE SECURED PROPERLY. NO DEFECT NOTED. A/C OK TO CONTINUE. ADD EMP:U247254SDR CALA2025063006043Cover · no discrepancyREMOVED L1 DOOR ESCAPE SLIDE PACK AND COVER ASSY FOR MX, REF AMM 25-66-01-000-801. REINSTALLED L1 DOOR ESCAPE SLIDE IN REF TO AMM TASK 25-66-01-400-803. OPS CHECK GOOD. ACCOMPLISHED RII INSPECTION OF L1 DOOR SLIDE INSTALLATION REF AMM 25-66-01 AND GMM 09-25-05SDR CALA2025062705982Slide · exposedFA REPORTS DOOR 1R SLIDE MATERIAL HANGING ON FLOOR INSPECTED R1 DOOR ESCAPE SLIDE SYS, RESECURED GIRT MATERIAL INTO SLIDE COVER. GIRT MATERIAL SHOWING WITHIN SERVICEABLE LIMITS REF AMM 25-66-01-400-803. OK TO CONTINUE SERVICE.SDR SWAA2025062785458Skirt · out of positionAFT ENTRY DOOR SLIDE EXCESSIVE FABRIC<[01] REPOSITIONED AFT ENTRY SKIRT SLIDE PER AMM 25-66-01 AND TASK MT 725-61-06.SDR DALA2025062704809Battery Pack · no testSHIP 193 LT O/W SLIDE SQUIB LIGHT NOT ILLUMINATED DURING SQUIB TEST 1. CORRECTIVE ACTION: T/S PER B767 FIM 25-65-00. FOUND BAD LT O/W SLIDE BATTERY. R/R LT O/W SLIDE BATTERY PER B767-300 AMM 25-65-17. LT O/W SLIDE SQUIB TEST CKS GOOD. P/N ON AD2013-1A. (731745SDR CALA2025062705980Slide · no discrepancyDOOR 1R SLIDE HAS YELLOW RAFT MATERIAL PROTRUDING FROM BOTTOM. NO DEFECTS NOTED REFERENCE AMM 25-66-00.SDR DALA2025062604783Slide · not seatedSHIP 6710 3L DOOR JAMMED WHILE ARMING. CORRECTIVE ACTION: RESEATED SLIDE ARM LEVER FOR THE 3L DOOR. ARMING OF 3L SLIDE DOOR CHECKS GOOD PER B757 AMM 25-66. (7414718)SDR SCNA20250625231Slide · not reportedR1 DOOR SLIDE UNUSABLE . R&R R1 SIDE IAW AMM 25-66-01 OK FOR SERVICE.SDR SWAA2025062785326Screw · looseSCREW LOOSE ON R2 SLIDE COVER<[01] RESECURED LOOSE SCREW IAW AMM 20-50-11. NO FURTHER DEFECTS NOTED.SDR CALA2025062705978Slide · no discrepancyDOOR L2 SLIDE PRESSURE BELOW GREEN RANGE IAW AMM 25-62-00-210-001-A. MODEL A GAUGE NEEDLE AT TOP OF GREEN BAND, 2L WAS OPEN IN HEATED ENVIRONMENT FOR CATERING.SDR CALA2025062605916Slide · low pressureSLIDE RAFT AT DOOR 3L PRESSURE GAUGE YELLOW NEEDLE IS OUT OF GREEN ON THE LOW SIDE. PX GAUGE READING BELOW GREEN LEVEL. REQUEST TO APPLY MEL 5211L. MEL 5211L TOMC REJECTING DEF REQUEST - MX TO REPLACE DR 3L SLIDE DOOR 3L DOOR MOUNTED ESCAPE SLIDE PACK REMOVEDSDR CALA2025062605886Slide · out of positionSLIDE PACK DOOR 2R HAS A LARGE GAP BETWEEN COVE R AND SLIDE UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. MAC METER INITIATED FOR WITH VENDOR ID V946316 MAC RELATED WORK ORDER 000000003141204 AND PRTR CLEMENTE, SDR CALA2025062605884Slide · unsecureSLIDE PACK 2L LOOSE PERFORMED DOOR MOUNTED SLIDE PACK CHECK AND ADJUSTED Z FOLD ON ESCAPE SLIDE PACK IAW AMM TASK 25-66-01-400-801 STEP D).(2)E. DOOR OPEN AND CLOSES WITHOUT HURT BAR INTERFERENCESDR CALA2025062605883Cover · unsecureDOOR 2R SLIDE COVER NOT SEATED FLUSH WITH DOOR. DOOR ARMS AND IN DICATES LOCKED INSTALLED BUSTLE REF AMM SUBTASK 25-66-01-414-066. ITEM OKAYSDR AALA202506256934Slide Raft · unpackedAIRCRAFT IN BASE MAINTENANCE: R1 DOOR SLIDE NEEDS TO BE REPLACED BECAUSE IT UNWRAPPED. MAINTENANCE REMOVED AND REPLACED SLIDE ON ROUTINE JOB CARD 26L00025011.SDR AALA202507031040Cable · disengagedAIRCRAFT IN BASE MAINTENANCE: R1 DOOR SLIDE RAFT COVER RELEASE CABLE DISENGAGED FROM SLIDE. REPLACED SLIDE RAFT PER TASK CARD 26L00025011.SDR CALA2025062705976Cover · dented1L SLIDE COVER HAVE A DENT. REPLACED DOOR 1L BUSSELL/ COVER REF AMM 52-11-02-904-004.SDR SWAA2025062584648Slide · out of positionPULL HANDLE EXPOSED ON AFT SERVICE DOOR SLIDE<[01] FOUND VELCRO PULL HANDLE COVER TUCKED UP IN SLIDE COVER ;PULLED DOWN AND PUT INTO PLACE PER SIPSDR GTIA2025062338967Slide · deployedFLIGHT CREW DEPLOYED L1 DOOR SLIDE ( PASSENGER OR OVER WING DOOR SLIDE/SLIDE RAFTS (WITHOUT PASSENGERS) )--SDR CALA2025062505862Gauge · no discrepancyAFT DOOR 2R GAUGE OUT OF NORMAL RANGE. SLIDE UPON INSPECTION, DOOR SLIDE PRESSURE IS WITHIN LIMITS PER AMM 25-66-01SDR CALA2025062505861Slide · no discrepancyREMOVED DOOR 2L ESCAPE SLIDE PACK AND INFLATION CYLINDER PINNED IAW AMM 25-66-01-000-801 REF LOGPAGE 5282032 REINSTALLED ORIGINAL SLIDE. REMOVED AND STOWED CYLINDER PIN PER AMM 25-66-01-400-801 C/W RII REQUIREMENTS FOR DOOR 2L SLIDE REINSTALLATION. REF AIPC 25SDR CALA2025062505860Cover · dislodgedON ARMING DOOR 02L COVER FOR SLIDE POPPED OPEN. BUSTLE INTACT AND SECURE CHECKED SLIDE PACK FOR SECURITY REFE AMM 25-66-01-200-802.SDR CALA2025062505859Slide · no discrepancyDOOR 2L SLIDE PRESSURE ISSUE. PRESSURE IN RED ZONE. DOOR 2L SLIDE PRESSURE WITHIN LIMITS REF AMM 25-66-01-200-801SDR CALA2025062505858Cover · no discrepancyREMOVED R1 SLIDE PACK AND COVER REF AMM 25-66-01 RE-INSTALLED R1 SLIDE PACK AND COVER REF. AMM 25-66-01. INCOMPLETE AMM REFERENCE RE-INSTALLED R1 SLIDE PACK AND COVER REF. AMM 25-66-01-400-803. VERRIFIED TECH INSTALLED R1 SLIDE PACK AND COVER REF. AMM 25-66-01SDR CALA2025062505856Slide · faultedPLEASE CHECK THE SLIDE PRESSURE GAUGE AT DOOR 2L AND REPLACE SLIDE IF THE NEEDLE IS IN AREA B CARRIED BY ELB ORIGINAL CYCLES LIMIT OF: 001 EXTENDED BY 001 NEW TIME REMAINING 001. REMOVED AND REPLACED DOOR 2 LEFT EVACUATION SLIDE REF 25-62-44. OPS CHECK SATISDR AALA202506246395Strap · out of positionAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT NOTIFIED FLIGHT DECK OF PRESSURE LEAK COMING FROM DOOR 4L. AC 33K FT, CABIN ALT 6K FT, 7.8 DELTA P. MAINTENANCE FOUND THE SLIDE STRAP PINCHED IN THE DOOR AND ROUTED AROUND THE GIRT ASSEMBLY. MAINTENANCE RE-ROUTED STRAP A
Back to JASC 2565