What was found
FA REPORTS DOOR 1R SLIDE MATERIAL HANGING ON FLOOR INSPECTED R1 DOOR ESCAPE SLIDE SYS, RESECURED GIRT MATERIAL INTO SLIDE COVER. GIRT MATERIAL SHOWING WITHIN SERVICEABLE LIMITS REF AMM 25-66-01-400-803. OK TO CONTINUE SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FA REPORTS DOOR 1R SLIDE MATERIAL HANGING ON FLOOR INSPECTED R1 DOOR ESCAPE SLIDE SYS, RESECURED GIRT MATERIAL INTO SLIDE COVER. GIRT MATERIAL SHOWING WITHIN SERVICEABLE LIMITS REF AMM 25-66-01-400-803. OK TO CONTINUE SERVICE.