Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2012020900012Slide Raft · faultyPILOT REPORTED L1 DOOR SLIDE WOULD NOT ARM. REMOVED AND REPLACED L1 DOOR ESCAPE SLIDE/ RAFT AND GIRT BAR ASSEMBLY IAW AIRBUS MAINTENANCE MANUAL 52-11-22.SDR UALA2012020900766Slide · faultyRT OVERWING SLIDE PACK BOARD COVER RELEASE TRIGGER NOT FULLY SEATED ON ARMING CAM. REMOVED AND REPLACED RT OVERWING SLIDE.SDR UALA2012020800762Slide · failedDOOR 2R EMERGENCY EVACUATION SLIDE FAILS EMERGENCY LIGHT TEST. TESTS GOOD WITH DUMMY TEST PLUG. REPLACED DOOR NR 2 RIGHT EVAC SLIDE PER AMM.SDR UALA2012020800761Slide · faultyDOOR 2L EMERGENCY EVACUATION SLIDE FAILS EMERGENCY LIGHT TEST. TESTS GOOD WITH DUMMY TEST PLUG. REPLACED NR 2 LEFT EVAC SLIDE PER AMM.SDR R61A201202060082Slide · looseCREW REPORTED R-1 SERVICE DOOR DISARM HANDLE DIFFICULT TO OPERATE. MAINTENANCE RE-SECURED R-1 DOOR EMERGENCY SLIDE BUSTLE PIN PER EMB AMM, OPS CHECK GOOD.SDR UALA2012020600690Slide · unserviceableLEFT WING OW SLIDE INFLATION HOSE KINKED AND TWISTED OUT OF LIMITS. REMOVED & REPLACED LEFT OVERWING SLIDE.SDR ZZDA2012133Slide · unserviceableTAIL CONE SLIDE UNABLE TO READ GAUGE. REMOVED AND REPLACED TAIL CONE SLIDE IAW B717 AMM 25-61-02.SDR UALA2012020200650Slide · unserviceableRIGHT OVERWING SLIDE (PCN 649-9124 S-N PF0102) HOSE COLLAPSED & KINKED FROM SLIDE TO ELBOW. REMOVED & REPLACED RIGHT OVERWING SLIDE. SLIDE ARMING PERFORMED ON TASK CARD.SDR SWAA2012021301390Cable · frayedR2 DOOR EMERGENCY EVAC SLIDE LATCH CABLE FRAYED. REMOVED AND REPLACED CABLE IAW SRM.SDR UALA2012020200653Slide · obstructedLT OVERWING SLIDE CATCHES ON AFT DOOR OPENING ACTUATOR LINKAGE. REMOVED & REPLACED LT O/W SLIDE IAW B767-300 AMM. RE-ARMING ACCOMPLISHED ON TASK CARD 4165R607.SDR RYNA201202010008Warning System · false activationRIGHT OVERWING SLIDE LIGHT COME ON IN FLIGHT. LIGHT WAS OFF ON ARRIVAL. THE SYSTEM WAS CHECKED OUT PER MM 25-65-00. NON DEFECTS WERE NOTED. BOTTLE PRESSURE WAS IN THE GREEN BAND. NO FURTHER ISSUES.SDR FDEA201202010416Slide · no testR1 DOOR SLIDE DOES NOT PRESS TO TEST DURING TROUBLESHOOTING, SWAPPED LIGHT MODULES AND REPLACED BATTERIES WITH NO HELP. R & R BUILDS IAW SMP, OPS CHECKED NORMAL.SDR UALA2012020200656Lanyard · unsecureDOOR 1L ARMING LEVER CANNOT BE MOVED TO THE ARMED POSITION. RE-SECURED LANYARD ON GIRT BAR AT 1L. ACP OPS CHECK NORMAL.SDR UALA2012020200624Battery Pack · dischargedLT OVERWING SLIDE TEST LIGHT INTERMITTENT. REPLACED BATTERY PACK (CORRECTION). REPLACED LT OVERWING SLIDE BATTERY PACK.SDR UALA2012020200623Battery Pack · no testTEST 1 RIGHT SIDE SLIDE NO TEST. REPLACED RIGHT SIDE FWD SLIDE BATTERY PACK, TEST OKAY. ACCOMPLISHED CRITICAL STEP INSPECTION FOR INSTALLATION OF RT SLIDE BATTERY PACK. INSTALLED BATTERY PACK PER MM.SDR IPXA12171370Lever · bindingTHE EMERGENCY SLIDE ARMING LEVER ON THE MAIN ENTRANCE DOOR BINDS WHEN ARMING THE SLIDE. PERFORMED EMERGENCY SLIDE ARMING FUNCTIONAL TEST WRT MM 52-10-30-05.SDR UALA2012020200633Slide · unserviceableRT OFF WING ESCAPE SLIDE INFLATION HOSE IS COLLAPSED AND APPEARS INTERNALLY DETERIORATED ALONG 80 PERCENT OF ITS LENGTH. REPLACED RT OFF-WING SLIDE PACK PER MM. ACCOMPLISHED RII INSPECTION, CRITICAL STEPS GROUP NR 1, OF RT OFF WING SLIDE INSTALLATION.SDR SWAA1201066Slide · out of positionR-2 DOOR ESCAPE SLIDE PRESSURE GAUGE OUT OF POSITION. REPOSITIONED SLIDE PER MT#G25-61-06SA AND MM.SDR UHLA2012013100028Slide · unwanted deployL1 DOOR SLIDE INADVERTENT DEPLOYMENT. REMOVED AND REPLACED FWD PASSENGER DOOR EMERGENCY EVACUATION SLIDE MECHANISM IAW EMB 170 MM 52-11-40. OPS CHECK GOOD.SDR UALA2012013000587Slide · defectiveR1 DOOR SLIDE PACK RELEASE MECHANISM FUSE IS NOT INSTALLED. REMOVED THE SLIDE ON THE R1 DOOR. INSTALLED THE NEW SLIDE ON THE R1 DOOR REF AMM 25-66-01 P401. ACP RII INSPECTION PER ALL CRITICAL STEPS IN GMM 09-25-05.SDR SWAA1201038Slide · unserviceableFWD ENTRY SLIDE OUT OF GREEN BAND. REMOVED AND REPLACED SLIDE 1 PER MM AND MT G25-61-06.SDR USAA2012013000018Release Pin · obstructedLEFT EMERGENCY SLIDE PANEL RELEASE PINS - TWO OF THREE FORWARD PINS PAINTED OVER. PER ALERT BULLETIN, RELEASE PINS SHOULD NOT BE PAINTED OVER. MX PREVIOUSLY COMPLIED WITH EO #2508Y025 INSPECTION OF BOTH SIDES L,R PAINT REMOVAL FROM THE OVERWING SLIDE ENCLOSUSDR FDEA201201280362Cover · tornWHEN ARMING RT ENTRY DOOR ARM LIGHT WILL NOT ILLUMINATE. FOUND SLIDE COVER CORD TANGLED IN GIRT BAR. INSTALLED SLIDE COVER CORRECTLY IAW MM 52-11-02. OPS CKD GOOD. FINAL CLOSED.SDR SWAA120703Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR USAA2012013000015Lock Pin · obstructedCREW CONCERNED ABOUT PAINT APPLICATION AT LEFT OVERWING EXIT SLIDE DOOR - POSSIBLE INTERFERENCE WITH DEPLOYMENT. MAINTENANCE REMOVED PAINT FROM (3 EACH) SLIDE ENCLOSURE BALL LOCK PINS.SDR DALA1204720931Cable · misinstalledTAIL CONE SLIDE INSTALLATION FAILED ROUTINE INSPECTION IN CVG. THE HARNESS CABLE WAS FOUND TO BE INCORRECTLY INSTALLED AT THE LEFT ATTACH POINTS. MAINTENANCE DID CORRECT THE INSTALLATION PER ERA 493276-14. RE-INSPECTED AND APPROVED.SDR FDEA201201260351Slide · dislodgedTHE SLIDE WAS OUT OF ITS CONTAINER WHEN S/O ARRIVED FOR PREFLIGHT. REINSTALLED SLIDE ON L1 DOOR IAW MM REF 25-60-015-2-0. OK FOR FLIGHT.SDR SWAA120620Slide · out of positionDURING SCHEDULED CV CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MM.SDR DALA1302241612Battery · inoperativeRT EMERGENCY ESCAPE SLIDE FAILS TEST 1 AND TEST 2 C/A T/S IAW FIM 25-65-00 RT EMERG BATT. REPLACED IAW AMM 25-65-17. OPS CK GOOD. RII TASK C/W PINS VERIFIED REMOVED AND STOWED.SDR USAA2012012700015Slide · low pressureL2 DOOR ESCAPE SLIDE PRESSURE FOUND LOW IN RED BAND WHILE ACCOMPLISHING JOB CARD 26C00025003. REMOVED AND REPLACED L2 DOOR ESCAPE SLIDE PER JOB CARD 26L00025010.SDR AALA20120127TUL06Slide · out of positionLEFT NUMBER 4 DOOR SLIDE INADVERTENTLY UNSUCCESSFULLY DEPLOYED. SLIDE FELL OUT OF HOUSING AND ASSIST BOTTLE DISCHARGED. AIRCRAFT FERRIED TO MIA FOR REPAIRS. REPLACED LEFT NUMBER 4 DOOR SLIDE AND ASSIST BOTTLE ON 01/24/2012 AT MIA. SYSTEM GROUND CHECK NORMASDR SWAA120627Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR SWAA120568Slide · out of positionDURING SCHEDULED CV CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MMSDR FDEA201201240318Static Line · out of positionTHE ARM LIGHT ON THE RT ENTRY DOOR IS NOT ILLUMINATED WHEN IN THE ARM POSITION. REPOSITIONED AND SECURED SLIDE PACK STATIC LINE REF AMM 25-66-01-4 & 25-66-10-2. SLIDE ARMED LIGHT CHECKED NORMAL.SDR IPXA2171332Warning Light · no testRED SLIDE ARMED WARNING LIGHT ON CREW ENTRY DOOR WILL NOT TEST. DEF M471518 ASSIGNED. OPS CHECK EVAC SLIDE RELEASE WARNING SYS IAW 52-73-00-05. OPS CHECKS GOOD. THIS CLEARS M471518.SDR FDEA201201230315Indicator · inoperativeL1 DOOR SLIDE TEST LAMP RETAINER FOUND INOPERATIVE, DURING SERVICE CHECK. SWAPED WITH R1, SLIDE LIGHT WORKS NORMALLY. R & R L1 REMOTE PRESSURE INDICATOR ASSY IAW AMM 25-61-04-4. OPS CHECKED GOOD.SDR UALA2012012300470Webbing · exposedTHE 4R DOOR HAS A SLIDE ROPE OR WEBBING EXPOSED. SECURED LACING IN SLIDE.SDR SWAA120552Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT OF CONTAINER, DID NOT DEPLOY, STILL OPERATIONAL. RE-INSTALLED SLIDE IAW MM.SDR SWAA120544Bracket · looseL2 DOOR EMERGENCY EVAC SLIDE BRACKET LOOSE. SECURED BRACKET PER MM.SDR SWAA120543Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR CALA2012012400040Actuator · faultyDURING LEFT OFF WING SLIDE FUNCTIONAL TEST LT SIDE SLIDE DID NOT DEPLOY. REMOVED AND REPLACED LT OFF WING SLIDE ACTUATOR WITH SERVICEABLE ACTUATOR P/N 126812-7 S/N 1134. OPS CHECK PERFORMED ON TASK CARD 19-2560-1-7650 (SYSTEM FUNCTIONAL CHECK) NO DEFECTS NOTSDR UALA2012012300453Switch · faultyEMERGENCY ESCAPE LIGHT REMAINED EXTINGUISHED DURING SLIDE SQUIB TEST 1 6 (05=L, 06=R). REWORKED SWITCH TEST SW, OPS OK.SDR FDEA201201210285Bottle · low pressureFORWARD ENTRY DOOR ESCAPE SLIDE BOTTLE PRESSURE IS LOW. REMOVED AND REPLACED SLIDE ASSYSDR USAA2012012300035Pin · unsecureRDU - CORD HANGING FROM SLIDE PACK DOOR 1-L. RESTOWED MTC SAFETY PIN AS REQUIRED.SDR FDEA201201200276Switch · contaminatedR1 DOOR SLIDE ARM LIGHT WILL NOT COME ON WHEN SLIDE IS ARMED. FOUND GREASE AND ICE BLOCKING PROXIMITY SWITCH. REMOVED ICE AND CLEANED TRACK. DOOR LIGHT OPERATED NORMALY WHEN DOOR IS ARMED. FOUND GREASE AND ICE BLOCKING PROXIMITY SWITCH. REMOVED ICE ANSDR ANCF2012011800109Slide · failedLEFT FORWARD SLIDE, DURING OPENING DOOR ARMED. (THE SLIDE WAS DEPLOYED AUTOMATICALLY BUT THE BOTTLE DID NOT ACTIVATE). IAW 25-62-44PB 401 THE ESCAPE-SLIDE PACK ASSY DOOR 1L WAS R & R.SDR FDEA201201190275Proximity Switch · obstructedR1 DOOR SLIDE ARM LIGHT WILL NOT COME ON WHEN SLIDE IS ARMED. FOUND GREASE AND ICE BLOCKING PROXIMITY SWITCH. REMOVED ICE AND CLEANED TRACK. DOOR LIGHT OPERATED NORMALY WHEN DOOR IS ARMED.SDR FDEA201201190264Slide · dislodgedSLIDE FELL OFF L1 DOOR. REINSTALLED SLIDE L-1 DOOR.SDR FDEA201201190259Bulb · inoperativeR1 DOOR EVACUATION SLIDE REMOTE PRESSURE PRESS TO TEST INOPERATIVE. REPLACED PUSH SWITCH LIGHT BULB ASSY AND OPS CHECKED NORMAL IAW MM 25-61-04-4.SDR SWAA120446Slide · out of adjustDURING SCHEDULED 2HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.
Back to JASC 2565