SDR USAA2011052691960Bottle · low pressureMX - PHL - EES - R-3 SLIDE BOTTLE PRESSURE LOW. MAINTENANCE REMOVED AND REPLACED R-3 SLIDE BOTTLE IAW AIRBUS MAINTENANCE MANAUL 25-62-49-000-001-01/400-001-0.SDR UALA2011052502568Cable · looseLEFT OVERWING SLIDE CABLE ASSY HAS PLAY AT AFT PIT COUPLING. SECURED PER MM & INSPECTED.SDR FDEA201105241966Lamp · inoperativeR1 DOOR EVAC SLIDE REMOTE PRESS TO REST LIGHT INOPERATIVE, RELAMPED AND REPLACED BATTERIES NO HELP. RELAMP PTT LIGHT SWITCH WITH 338 3 VOLT BULBS,TEST CHECKED NORMAL INSTALLED NEW BATTERIES PRECAUTIONARY, REMOVED CONTROL STICKER, ALL OPS GOOD.SDR USAA2011053100001Reservoir · brokenPIT - EES - LEFT OVERWING INFLATION BOTTLE CABLE FOUND BROKEN AT RELEASE CABLE DISASSEMBLE POINT. MAINTENANCE REPLACED LEFT OFFWING ESCAPE SLIDE INFLATION RESERVOIR IAW AIRBUS MAINTENANCE MANUAL 25-62-46.SDR USAA2011052700007Slide · crackedLEFT OVERWING SLIDE BOX HAS A CRACK AROUND ATTACH FASTENER. REPLACE SLIDE ASSY PER AMM 25-62-42-400-001-0.SDR USAA2011052500006Cable · brokenLEFT OVERWING INFLATION BOTTLE CABLE FOUND BROKEN AT RELEASE CABLE DISASSEMBLE POINT. REPLACED LEFT OFFWING ESCAPE SLIDE INFLATION RESERVOIR IAW A320 AMM 25-62-46.SDR USAA20110525BB039Battery Pack · dischargedCLT - THE EMERGENCY ESCAPE SQUIB LIGHT FAILED TO COME ON DURING TEST (LEFT LIGHT). MAINTENANCE REMOVED AND REPLACED THE RIGHT, OFF-WING ESCAPE SYSTEM BATTERY PACK.SDR UALA2011052502544Slide · malfunctionedDOOR 1R SLIDE LIGHT DOES NOT ILLUMINATE. GIRT BAR UNATTACHED AND DROPPED AND DAMAGED WHEN DOOR CLOSED. REPLACED SLIDE PER MM.SDR UALA2011052402537Slide · defectiveDOOR 1R SLIDE LIGHT DOES NOT ILLUMINATE. SAMC TEXT: GIRT BAR UNATTACHED AND DROPPED AND DAMAGED WHEN DOOR CLOSED. REPLACED SLIDE.SDR UALA2011052302507Slide · faultyDURING OPERATIONAL TEST OF EMERGENCY LIGHT SYSTEM HAVE FAULT MESSAGE EPSU EXT. LOAD FWD L ON DISPLAY PANEL. TBSHT PER TSM NEED QUALIFICATIONS TO CONTINUE TBSHTING STEP 4B2. SUSPECT DOOR SLIDE. ACP SELF TEST ON FWD EPSU. EPSU SELF TEST FAULTS EXTERNAL LOADSSDR SWAA113821Slide · low pressureL1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE LOW. REMOVED AND REPLACED SLIDE PER MT.SDR FDEA201105201905Slide · malfunctionedL1 CREW ENTRY DOOR SLIDE LIGHT WAS DIFFICULT TO ARM. OPS CHECKED L1 DOOR SLIDE ESCAPE SYSTEM REF MM 25-66-00-5-0. OPS CHECK GOOD, ACFT OK FOR SERVICE.SDR SWAA113785Slide · out of positionDURING SCHEDULED SPV CHECK FOUND, L1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA113717Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR FDEA201105191877Connector · unsecureR1 DOOR SLIDE LIGHT DOES NOT TEST. RESEATED CONNECTOR ON BACK OF PRESS TO TEST SWITCH R1 DOOR. OPS CHECKED NORMAL. OK FOR SERVICE.SDR SWAA113749Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT OF CONTAINER, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR FDEA201105181869Bulb · failedDURING PREFLIGHT CHECK FOUND LH DOOR EVAC SLIDE REMOTE PRESSURE PRESS TO TEST LIGHT INOP. REPLACED PRESS TO TEST SW BULB AND REMOTE PRESS INDICATION OPS TEST PASSED PER MM25-61-04-4-0SDR UALA2011051802471Slide · misinstalledMAIN CABIN DOOR 2R EMERGENCY SLIDE NOT IN MOUNTS PROPERLY. REMOVED AND RE-INSTALLED R-2 DOOR SLIDE CORRECTLY PER MM ON NON ROUTINE 47013.SDR DALA1138570627Rod End · corrodedLT OVERWING SLIDE CARRIER SNUBBER RODEND CORRODED. REPLACED ROD END AT SAA ON N/R CARD 188054.SDR UALA2011051802451Strap · chafedMAIN CABIN L-2 DOOR SLIDE, GIRT BAR RELEASE STRAP CHAFED. RMV'D & RPL'D MAIN CABIN L-2 DOOR SLIDE ASSY PER MM.SDR UALA2011051802448Slide · misinstalledMAIN CABIN DOOR 1L DOOR SLIDE NOT IN MOUNTS PROPERLY. REINSTALLED SLIDE CORRECTLY PER MM.SDR UALA2011051702434Slide · crackedRIGHT HAND OFFWING ESCAPE SLIDE HAS A 6 INCH CRACK ALONG THE LOWER AFT EDGE. OK TO CF AND WITHIN LIMITS PER MT25-018. NOTED CRACK SEALED PER MT25-018. NO PARTS OFFWING SLIDE STOCKED BOS. PART NO V70167 D31865-112. REPLACED RIGHT HAND OVERWING SLIDE.SDR HALA2011051600199Slide · dirtyUNABLE TO ARM SLIDE ON FWD GALLEY DOOR. CLEANED DEBRIS FROM GROUND ON FWD GALLEY DOOR SLIDE. OPS & CONDITION & SECURITY CHECKED OK.SDR USAA20110516BA042Slide · bindingDURING A SLIDE OPERATIONAL TEST, THE R2 DOOR SLIDE DID NOT PROPERLY FUNCTION. IT WAS OBSERVED AS: "DOOR ASSIST BOTTLE DISCHARGED, BUT DOOR DID NOT OPEN FULLY. SLIDE GIRT WAS RESTRICTING DOOR FROM OPENING. SLIDE BOTTLE NEVER DISCHARGED." MAINTENANCE REPLACSDR UALA2011051602421Lanyard · looseDOOR 2L WILL NOT ARM. SECURED SURVIVAL KIT LANYARD AT SLIDE GIRT FOR DOOR 2 LEFT.SDR USAA2011051691856Slide · low pressureFLT 112 - LAS-LAX - EMERGENCY EGRESS SYSTEM - L1 DOOR SLIDE BOTTLE PRESSURE LOW. REMOVED AND REPLACED L1 DOOR ESCAPE SLIDE PER JOBCARD 26L00025010.SDR SWAA113674Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR SWAA113664Slide · low pressureL2 DOOR EMERGENCY EVAC SLIDE LOW PRESSURE. REMOVED AND REPLACED SLIDE PER MT.SDR UALA2011051202360Slide · obstructedREPLACE THE LT OVERWING SLIDE ACCT. ONE OF THE SLIDE ENCLOSURE BALL-LOCK-PINS IS PAINTED OVER. REPLACED LEFT HAND OVERWING SLIDE PER MM.SDR UALA2011051102330Bolt · unsecurePASSENGER ENTRY-SERVICE DOORS R FWD EVAC SLIDE ARM LEVER DIFFICULT TO POSITION. FOUND BOLT IN ROD END LOOSE CAUSING GIRT BAR TO BIND. SECURED BOLT. OPS CHECKED REF AMM.SDR ZZDA2011470Slide · unserviceableL-1 DOOR PAX SLIDE PSI IN RED. REMOVED AND REPLACED L-1 DOOR SLIDE REF 717 MM 25-61.SDR NOCA05211Slide · failedLEFT NR 2 DOOR SLIDE FAILED TO DEPLOY WHILE ACCOMPLISHING A SLIDE SAMPLING. REMOVED AND REPLACED L2 DOOR SLIDE AS PER JOB CARD 757-25-015-01.SDR HALA2011051000194Slide · no testR1 DOOR SLIDE FAILED DEPLOYMENT SYS CHECK. SLIDE DID NOT DROP OUT OF ACFT. REMOVED SHIM FROM LINER COVER DOOR CLIP. ACCOMPLISHED OPS CHECK OF SERVICE DOOR SLIDE DEPLOYMENT SYS, NO DEFECT. REF AMM 25-61-03 & 25-61-00.SDR SWAA113363Slide · low pressureDURING SCHEDULED CV CHECK FOUND, L2 ESCAPE SLIDE HAS LOW PRESSURE, OUT OF GREEN BAND. REMOVED AND REPLACED SLIDE IAW MT.SDR SWAA113362ASlide · out of adjustDURING SCHEDULED CV CHECK FOUND, R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA113361ASlide · out of adjustDURING SCHEDULED CV CHECK FOUND, L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA113350Slide · out of adjustDURING SCHEDULED HC2 CHECK FOUND, R-2 DOOR SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR YENA20110510252Cable · defectiveFLT 6415 JFK-LCQ ON GROUND FOR MAINTENANCE, REF NR 440011-32616 RT OVERWING EMERGENCY ESCAPE SLIDE CABLE FAILS TO TRAVEL REQUIRED DISTANCE AND DOES NOT RETURN TO EXTENDED POSITION. SERVICED RT OVERWING ESCAPE SLIDE CABLE IAW AMM 25-62-00-03. OPS CHECKS GOOD SDR YENA20110510251Cable · defectiveFLT 6415 JFK-LCQ ON GROUND FOR MAINTENANCE, REF NR 440011-32615 LT OVERWING EMERGENCY ESCAPE SLIDE CABLE FAILS TO TRAVEL REQUIRED DISTANCE & DOES NOT RETURN TO EXTENDED POSITION. SERVICED LT OVERWING ESCAPE SLIDE CABLE IAW AMM 25-62-00-03. OPS CHECK GOOD IAWSDR UALA2011051002327Release Pin · obstructedLT OVERWING SLIDE HAS COMPARTMENT DOOR RELEASE PINS PAINTED OVER. REPLACED LT OVERWING EXIT SLIDE ASSY. INSPECTED SLIDE INSTALLATION, EEL CONNECTOR AND INFLATION HOSE CONNECTED.SDR UALA2011051002312Release Pin · obstructedRT OVERWING SLIDE HAS COMPARTMENT DOOR RELEASE PINS PAINTED OVER. REPLACED RT OVERWING SLIDE ASSY. VERIFIED SLIDE INSTALLATION. EEL CONNECTOR AND INFLATION HOSE CONNECTED.SDR R61A20110106Slide · unlacedWHILE REMOVING R-2 EMERGENCY EVACUATION SLIDE, THE LACING CAME UNDONE. MAINTENANCE REMOVED AND REPLACED R-2 EMERGENCY EVACUATION SLIDE PER EMB AMM.SDR SWAA113584Slide · low pressureL1 DOOR EMERGENCY SLIDE PRESSURE LOW. REMOVED AND REPLACED SLIDE PEP MT.SDR UHLA2011050900168Slide · out of positionSLIDE FELL OUT OF PLACE ON L1 DOOR FROM GIRT BAR ENGAGED UPON OPENING. REMOVED AND REPLACED L1 DOOR SLIDE IAW AMM 25-65-01, OPS CHECK GOOD.SDR UALA2011050902305Battery Pack · dischargedLEFT ESCAPE SLIDE SQUIB TEST NOT WORKING. REPLACED BATTERY PACK FOR THE LEFT OVERWING ESCAPE SYSTEM POWER SUPPLY.SDR UALA2011050902294Bottle · unserviceableLEFT OFF WING EMERGENCY SLIDE BOTTLE NEEDS REPLACEMENT. REPLACED LT OVERWING SLIDE EMERGENCY BOTTLE. ACCOMPLISHED RII INSPECTION AS REQUIRED REF MM. ALL PINS REMOVED AND SYSTEM RE-ARMED.SDR SWAA113521Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR UALA2011050902250Lanyard · out of positionLANYARD HANGING FROM SLIDE PACK. REPLACED LANYARD.SDR R61A20110104Slide · failedMAINTENANCE REPORTED THAT THE FORWARD PASSENGER DOOR EVACUATION SLIDE FAILED IT'S SCHEDULED FUNCTIONAL CHECK. MAINTENANCE REMOVED AND REPLACED THE FORWARD PASSENGER DOOR EVACUATION SLIDE PER EMB AMM.SDR SWAA113409Slide · out of adjustDURING SCHEDULED CV CHECK FOUND, R2 DOOR SLIDE OUT OF ADJUST. ADJUSTED PER AMM.
Back to JASC 2565