Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA113392Latch · looseL1 DOOR EMERGENCY ESCAPE SLIDE LATCH LOOSE. SECURED LATCH PER MM.SDR UALA2011050302169Battery Pack · no testRIGHT OVERWING SLIDE TEST DOES NOT WORK. REPLACED RIGHT OVERWING SLIDE BATTERY PACK M962 PER MM. COMPLETED SUCCESSFUL OPERATIONAL CHECK.SDR UALA2011050202162Bottle · reads lowCIDS CAUTION AT DEPARTURE. LT EMERGENCY SLIDE BOTTLE PRESSURE LOW. CANNOT APPLY MEL AS BOTTLE PRESSURE NEEDLE IN RED. BOTTLE REPLACED.SDR SWAA113313Slide · looseDURING SCHEDULED HC2 CHECK FOUND FWD ENTRY DOOR ESCAPE SLIDE GIRT FLAP NOT PROPERLY SECURED TO GIRT SHELF. RE-INSTALLED PER DOC.SDR CNMA20110024Light · no testL1 DOOR SLIDE EMERGENCY LIGHTS FAILED TO ILLUMINATE DURING OPS TEST. SLIDE DEPLOYED NORMALLY. REPLACED SLIDE ASSY.SDR USAA20110503BA038Slide Raft · defectivePHL - L2 SLIDE PRESSURE INDICATED ON THE FLIGHT ATTENDANT PANEL. FOUND A BAD SLIDE DISARMING MECHANISM WHERE THE SLIDE SAFETY PIN IS INSERTED. THE "C" CLIP WAS MISSING AND A SPRING WAS COMING OUT OF THE END. MAINTENANCE REMOVED AND REPLACED THE L2 SLIDE.SDR USAA2011060700002Slide Raft · unserviceableSAL - S4 - OVER PRESSURE IN SLIDE RAFT AT PASS/CREW DOOR 831. REPLACED SLIDE RAFT AT PASS/CREW DOOR 831 IAW CARD 26C83152008.SDR USAA2011060700003Slide · not seatedSAL - S4 - DURING VISUAL INSPECTION OF THE LEFT OFF WING ESCAPE SLIDE FOUND BALL LOCK MECHANISM WAS NOT FLUSH WITH THE DOOR OF ENCLOSURE. REPLACED LEFT OFF WING ESCAPE SLIDE IAW JOB CARD 26C19053012.SDR UHLA2011050100167Lanyard · out of positionL2 SERVICE DOOR WON'T CLOSE. AFT PIN AND LANYARD NOT INSERTED INTO AFT HOUSING. RE-INSERTED PIN WITH LANYARD IAW EMB 170 MM 25-65-01, OPS CHECK OF SLIDE ARM/DISARM NORMAL, PIN NOW SECURE IN HOUSING OF EMERGENCY EVAC SLIDE ASSY.SDR ZZDA2011451Slide · unserviceableTAIL CONE SLIDE S/N 1477 INFLATE BOTTLE PRESSURE INDICATION BELOW NORMAL. REMOVED AND REPLACED TAIL CONE SLIDE REF B717 AMM 25-61 P/N 64210-103 OFF 1417 ON 1231.SDR USAA20110429BB034Slide · low pressurePHX - THE L4 DOOR EVACUATION SLIDE PRESSURE GAUGE IS IN THE RED. MAINTENANCE REMOVED AND REPLACED THE L4 DOOR SLIDE.SDR SWAA113264Slide · looseDURING SCHEDULED 2HC1 CHECK FOUND, FWD ENTRY DOOR SLIDE GIRT OUTPLAY IS EXCESSIVE. ADJUSTED FWD ENTRY DOOR SLIDE GIRT PER AMM.SDR UALA2011042702049Carrier Assy · out of toleranceRT OVERWING SLIDE CARRIER CRACKED IN AREA 2 AFT SIDE. CRACK MEASURES 6 AND 5-8 INCH VERTICALLY ALONG AFT SIDE IN AREA 2. OK TO CONTINUE IN SERVICE TILL NEXT *A* CHECK. MAX ALLOWABLE LENGTH 7 INCHES. REF MAINT TIP MT 25-018 AND AMM25-62-42. REPLACED RT OVESDR FDEA201104271652Slide · dislodgedON PREFLIGHT FOUND SLIDE PACK SITTING ON MAIN DECK FLOOR. R & R EVACUATION SLIDE ASSY ON THE L1 DOOR REF MM 25-60-015-2. ACFT OK TO CONTINUE AT THIS TIME. PREMATURE REMOVAL/INSTALLATION.SDR CALA2011042700316Slide · low pressureFOUND L-1 DOOR SLIDE PRESS LOW. REMOVED AND REPLACED L-1 DOOR SLIDE USING TASK 25-66-01 -400-801 AS A REFERENCE. SLIDE, B777-200 OFF 25-2560-9-0005 0635 ON 25-2560-9-0005 0458.SDR SWAA113177Slide · failedDURING SCHEDULED 2HC2 CHECK, R1 DOOR EMERGENCY EVAC SLIDE FAILED SLIDE DEPLOYMENT CHECK. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA113158Bracket · crackedDURING SCHEDULED 24Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE BRACKET ASSY CRACKED. REMOVED AND REPLACED BRACKET ASSY PER SRM.SDR SWAA113153Slide · out of positionDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REMOVED AND REPLACED SLIDE PER MT.SDR ZZDA2011410Lanyard · detachedFWD SERVICE DOOR ESCAPE SLIDE LANYARD UNATTACHED. (AWI) RE-INSTALLED R-1 GIRT BAR LANYARD IAW AMM 25-61. (AWI)SDR UALA2011042502002Bottle · low pressureFOUND 1 RT DOOR SLIDE BOTTLE PRESSURE IN RED. REPLACED IR DOOR SLIDE PER MM OPS CHECK NORMAL. 1R MED SLIDE PERFORMED RII INSPECTION OF SLIDE INSTALLATION ASSY. NO DEFECTS FOUND.SDR SWAA113113Slide · looseR2 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MM.SDR SWAA113086Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT. RE-INSTALLED SLIDE PER MT.SDR YENA20110424241Slide · failedPRIOR TO DEPARTURE WITH L1 DOOR CLOSED, THE F/A REPORTED L1 DOOR SLIDE TOUGH TO ARM. TECH HAD TO REMOVE THE SLIDE IN ORDER TO OPEN DOOR. REPLACED L1 DOOR SLIDE ASSY IAW 25-65-01. OPS CHECKED GOOD.SDR SWAA112981Slide · looseDURING SCHEDULED MV2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MM.SDR UALA2011042502009Hook And Loop · unsecureCREW REPORT: SLIDE PACK COVER AT 2L HAS FALLEN OFF. RE-SECURED BUZZLE, FOUND VELCRO ON TOP UNGLUED. RESECURED WITH DOUBLESIDED TAPE AS INTERIM.SDR UALA2011042502000Battery Pack · dischargedNO TEST 1 ON EMERGENCY ESCAPE SLIDE TEST. LIGHT PRESS TO TEST OKAY. REPLACED BOTH SLIDE BATTERY PACKS.SDR IPXA11166206Switch · faultyEVACUATION SLIDE WARNING LIGHT INOP. TROUBLESHOT IAW FIM 52-73-00, FIG 101, PG 102 AND FOUND TEST SWITCH 39WN FAULTY. R & R TEST SWITCH 39WN IAW WDM 52-73-01 & MM 52-73-14-04 ITEMS 1-2C. WARNING LIGHT TEST NORMAL IAW MM 52-73- 14-04 ITEM 2D. THIS CLEARS M45SDR UALA2011042201952Slide · crackedON PRE-DEPARTURE RT OVERWING ESCAPE SLIDE AFT EDGE HAS 8.5 INCH CRACK, OUT OF LIMITS. NOTE CRACK IS IN AREA 2. REPLACED RT SLIDE PER MM. INSP AND FORMAN PRESENT. ELEC CONNECTOR AND HOSE INSTALLED.SDR U2RA4534578095Light · intermittentNR 2 RT SLIDE ARM LIGHT ("Q" LIGHT) IS INTERMITTENT.SDR UALA2011042001916Slide · unserviceableNR 4 RT MED SLIDE COVER AFT UPPER PIN LACING IS BROKEN. REPLACED 4R MED SLIDE PER MM.SDR ZZDA2011403Pin · dislodgedL1 DOOR SLIDE PIN DISLODGED. REMOVED AND REPLACED L1 DOOR SLIDE PER 717 AMM 25-61.SDR USAA20110421BB032Target · missingCLT - FOUND THE R4 DOOR EVACUATION SLIDE ARMING LEVER BINDING, AND THE SLIDE ARM LIGHT INOPERATIVE. MAINTENANCE REPLACED A MISSING PROXIMITY SWITCH ACTUATOR (TARGET), AND ADJUSTED THE GIRT BAR AND TARGET AS REQUIRED.SDR SWAA113084Slide · unwanted deployDURING SCHEDULED RON CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY DEPLOYED. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA113024Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR SWAA112970Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT OF CONTAINER, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR SWAA112969Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA112886Cable · misroutedDURING SCHEDULED SPV CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE LATCH CABLE MISROUTED. REROUTED CABLE PER MM.SDR 2011FA0000371Cylinder · failed2 LIFE RAFT INFLATION CYLINDERS WERE CHARGED TO 3000 PSIG (PHOTO OF PRESSURE GAUGE). IAW OEM REQUIREMENTS, CHARGE PRESSURE SHOULD BE 4500-4650 PSIG. THIS DEFECT WOULD HAVE AFFECTED THE SURVIVAL OF ACFT OCCUPANTS IN THE EVENT LIFE RAFT NEEDED IN AN EMERGENCY.SDR SWAA113026Slide · out of positionDURING SCHEDULED SPV CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA112956Handle · missingL2 DOOR EMERGENCY EVAC SLIDE HANDLE MISSING. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA112864Lens · brokenDURING SCHEDULED CV CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE LENS BROKEN. REMOVED AND REPLACED LENS PER MM.SDR ZZDA2011397Slide · disconnectedR1 DOOR SLIDE DISCONNECTED. INSPECTED AND RE-INSTALLED SLIDE IAW M/M 25-66. A/C OK FOR SERVICE.SDR FDEA201104171509Slide · unwanted deployRT CABIN DOOR INADVERTENTLY OPENED IN ARMED CONDITION. RELEASED FOR SERVICE IAW MEL: 52-11-01-02 CATEGORY: C EXPIRATION: 27APR11, "MEL 52-11-01-02: R1 CREW ENTRY ESCAPE SLIDE -INOP. THE R1 DOOR ESCAPE SLIDE ASSY IS REMOVED FROM ACFT IAW EA 6-5210-150158, SSDR UALA2011041801871Slide · deployedPASSENGER DOOR 2R ESCAPE SLIDE RAFT REMOVED FOR DEPLOYMENT. NEEDS TO BE RE-INSTALLED AND SOLD TO INSPECTION PER MM. REPLACED SLIDE PER MM.SDR SWAA112954Slide · low pressureL1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATOR LOW. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA112952Cover · crackedDURING SCHEDULED CV CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE VIEWER COVER CRACKED. REMOVED AND REPLACED COVER PER MM.SDR SWAA112951Lens · crackedDURING SCHEDULED CV CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE COVER LENS CRACKED. REMOVED AND REPLACED LENS PER MM.SDR SWAA112900Slide · low pressureDURING SCHEDULED MV1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATOR LOW. REMOVED AND REPLACED SLIDE PER MT.SDR GTIA1100010Handle · looseCREW ADVISED R2 DOOR SLIDE ARM HANDLE IS LOOSE.SDR SWAA112862Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.
Back to JASC 2565