Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA094201Slide · out of adjustDURING SCHEDULED 2HC2 CHECK, FOUND R1 DOOR EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE ASSY PER MM.SDR NWAA092339613Lanyard · misroutedDURING A NON-ROUTINE MAINTENANCE CHECK THE TAIL CONE EMERGENCY EVACUATION SLIDE DEPLOYMENT LANYARDS WERE FOUND TO BE MISROUTED. THIS CONFIGURATION OF THE STRAPS BEING ROUTED ON THE WRONG SIDE OF THE TOP DEPLOYMENT LANYARD COULD PREVENT THE PROPER OPERATION OF SDR UALA2009062901847Cover · brokenSLIDE 2L COVER BROKEN OFF AT HINGES. SECURED SLIDE COVER AT DOOR 2L.SDR USAA20090629BB103Slide · low pressureCLT - ON OVERNIGHT CHECK FOUND R1 DOOR SLIDE PRESSURE LOW. MAINTENANCE REPLACED R1 DOOR SLIDE.SDR SWAA094171Slide · out of positionR1 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. DID NOT DEPLOY. INSTALLED SLIDE ASSY PER MT.SDR SWAA094170Slide · out of adjustR1 DOOR EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR USAA2009062991631Slide · unserviceablePIT - EES - C1 CHECK - AFT PASSENGER DOOR SLIDE ASSEMBLY PACK OPENING PIN CLOSURE STRING BROKEN. REPLACED SLIDE.SDR UALA2009062901831Latch · wornRT OVERWING SLIDE DOOR LATCH NR 2 HAS WEAR GROOVE. INSTALLED NEW NR 2 LATCH. LATCH SYSTEM ADJUST AND OPS CHECKS GOOD.SDR UALA2009062901830Latch · wornRT OVERWING SLIDE DOOR LATCH NR 3 HAS WEAR GROOVE. INSTALLED NEW NR 3 LATCH. LATCH SYSTEM ADJUSTED AND OPS CHECKS GOOD.SDR UALA2009062901829Latch · wornRT OVERWING SLIDE DOOR LATCH NR 4 HAS WEAR GROOVE. INSTALLED NEW NR 4 LATCH. LATCH SYSTEM ADJUSTED AND OPS CHECKS GOOD.SDR UALA2009062901828Housing · crackedRT OVERWING COMPT DOOR DISCONNECT HOUSING IS CRACKED. INSTALLED NEW DISCONNECT HOUSING.SDR UALA2009062901827Cylinder · faultyRT OVERWING SLIDE CYLINDER INFLATION TRIGGER CABLE BALL END IS NOT BEHIND THE RETAINER SPRING. INSTALLED NEW RT SIDE INFLATION CYLINDER.SDR UALA2009062901825Slide · unserviceableDOOR MOUNTED SLIDE INFLATION PRESSURE IS BELOW GREEN TEMPERATURE COMPENSATOR INDICATOR AT MED NR 5 LT. REPLACED SLIDE-RAFT. VERIFIED TRIGGER SAFETY PIN REMOVED, INFLATION BOTTLE SAFETY PIN REMOVED AND ASSIST BOTTLE SAFETY PIN REMOVED. OPERATED ARM-DISARM LESDR ZZDA2009193Slide · low pressureL1 PACK PRECHARGE APPEARS LOW. REMOVED AND REPLACED L1 DOOR SLIDE REF MM 25-61-01.SDR SWAA094096Slide · out of positionL2 DOOR EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE ASSY PER MM.SDR UALA2009062401780Slide · faultyCABIN EMERGENCY LIGHTS FAIL. EPSU EXT LOADS AFT L. TROUBLESHOT SYSTEM. FOUND DOORS 2L AND 2R SLIDE LIGHTS INOP WILL NEED 2 SLIDES. REPLACED AFT RIGHT DOOR SLIDE AND THE LEFT AFT DOOR SLIDE. REPLACED AFT RIGHT DOOR SLIDE AND THE LEFT AFT DOOR SLIDE.SDR UALA2009062501799Aspirator · leakingASPIRATOR LEAKS FROM BARREL. THERE IS NO PHYSICAL OR EXTERNAL DAMAGE TO THE ASPIRATOR. THE ASPIRATOR IS LEAKING FROM INTERNAL COMPONENTS, THEREFORE THE CAUSE CANNOT BE DETERMINED. REPLACED ASPIRATOR.SDR SWAA094115Slide · out of adjustDURING SCHEDULED CH2 CHECK, FOUND L1 DOOR EVACUATION SLIDE OUT OF ADJUST. REPOSITIONED SLIDE ASSY PER MT.SDR SWAA094114Slide · out of adjustDURING SCHEDULED CH2 CHECK, FOUND R2 DOOR EVACUATION SLIDE OUT OF ADJUST. REPOSITIONED SLIDE ASSY PER MT.SDR SWAA094098Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EVACUATION SLIDE OUT OF ADJUST. RE-ADJUSTED SLIDE ASSY PER MM.SDR SWAA094087Slide · looseR1 DOOR EVACUATION SLIDE LOOSE. RE-INSTALLED SLIDE ASSY PER MT.SDR SWAA094070Slide · out of positionR1 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR USAA2009062391568Slide · unserviceablePIT - C7 - EES - L-2 DOOR SLIDE LACING CHORD LOOSE, SLIDE COVER WILL NOT FIT. REPLACED L-2 DOOR SLIDE.SDR USAA2009062591590Line · looseFLT 1841 - RDU-PHL - EMERGENCY EQUIPMENT - MAIN CABIN DOOR SLIDE CORD IS LOOSE. REPOSITIONED MOORING LINE UNDER DECORATIVE COVER PER MAINTENANCE MANUAL 25-62-44-991-003.SDR ASAA0946007Hinge · stiffR1 DOOR SLIDE DEPLOYED SIDEWAYS DURING TEST. FOUND HINGES ON R1 DOOR ESCAPE SLIDE COMPARTMENT BACKING PAN SHELF VERY STIFF TO MOVE BY HAND. REMOVED AND REPLACED ESCAPE SLIDE COMPARTMENT ASSY WITH NEW SLIDE PACK.SDR USAA2009062391564Cable · misroutedCLT - C3 - EES - RELEASE CABLE ROUTED INCORRECTLY ON AFT SERVICE DOOR SLIDE. RE-ROUTED RELEASE CABLE ON AFT SERVICE DOOR SLIDE IAW B737 AMM 25-61-10.SDR SWAA094065Slide · low pressureDURING SCHEDULED 24Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE GAUGE LOW PRESSURE. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA094047Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UALA2009062201747Slide · out of positionRIGHT AFT MAIN ENTRY DOOR SLIDE FOUND RELEASED FROM THE PACK WHEN SLIDE COVER WAS REMOVED. REPLACED SLIDE.SDR IPXA09M56381Light · inoperativeINSPECTION TYPE:N/A L1 DOOR EVAC SLIDE REMOTE PRESS TO TEST GAUGE INOP. FOUND L1 DOOR REMOTE PRESS SWITCH TO BE GOOD AND R1 INOP, REPLACED R1 REMOTE PRESSURE SWITCH LIGHT AND BATTERIES. THIS CLEARS M403173.SDR IPXA09156378Girt Bar · detachedINSPECTION TYPE:N/A EMERGENCY EXIT SLIDE WILL NOT DISARM. MECHANICALLY LATCHED IN ARMED POSITION. RE-ATTACHED GIRT BAR SLIDER TO DOOR PER MM 25-61-21-4. OPERATED DOOR SEVERAL TIMES. OK FOR SERVICE.SDR IPXA09M56367Light · faultyEVAC SLIDE REMOTE PRESS PTT IND SYS LIGHT STAYS ON. SLIDE PRESSURE OK. REMOVED AND REPLACED L1 DOOR EVAC SLIDE IAW MM 25-61-15-4. CHECKED FOR PROPER FUNCTION OF DOOR OPERATION. INSTALLATION AND FUNCTION OF REMOTE PRESSURE IND LIGHT. ALL SATISFACTORY.SDR IPXA09156364Slide · inoperativeINSPECTION TYPE:N/A CREW ENTRY DOOR SLIDE INOP. CLEAN AND LUBED CREW ENTRY DOOR EMERGENCY HANDLE MECH & LINKAGE CYCLE SEVERAL TIMES. OPS CHECK NORMAL. REF MM 52-10-30-05. CLEAR M403007 PLACARD REMOVED.SDR USAA2009061891505Slide · brokenPIT - C7 - EES - L-1 DOOR SLIDE COVER RELEASE STRAP CONNECTION HOOKS BROKEN. REPLACED L-1 DOOR SLIDE.SDR UALA2009061801733Slide · faultyEMERGENCY LIGHT TEST FAILS, FAULT "EXT LOADS FWD R". TROUBLESHOOT SYSTEM FOUND DOOR 1R CAUSING EMERGENCY LIGHT FAILURE DURING TEST. REPLACED RT DOOR SLIDE ASSY. INSTALLATION AND OPS CHECKS GOOD, EMERGENCY LIGHT TESTS GOOD.SDR UALA2009061801732Slide · crackedRAMP REPORTED CRACK IN RT OVERWING SLIDE PACK AT DEPARTURE TIME (APPROX 8 INCHES LONG). REPLACED OFF WING SLIDE.SDR USAA2009061891512Slide · low pressureFLT 482 - PHL - EMERGENCY EGRESS SYSTEM - CIDS PANEL MESSAGE: CHECK EMERGENCY SLIDE PRESSURE DOOR 1R. MAINTENANCE REMOVED AND REPLACED THE 1R DOOR SLIDE.SDR SWAA093959Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA093944Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA093920Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. DID NOT DEPLOY. RE-INSTALLED SLIDE PER MM.SDR IPXA09156354Slide · inoperativeESCAPE SLIDE INOP. INSTALLED SLIDE PER AMM 25-61-21-04. INSTALLED GIRT BAR, SLIDER AND COVER PER AMM 25-61-21-04.SDR USAA2009062391569Slide · misroutedCLT - C6 - EES - AFT ENTRY DOOR SLIDE RELEASE CABLE IS NOT ROUTED PROPERLY. RE-ROUTED AFT ENTRY DOOR SLIDE RELEASE CABLE IAW B737 AMM 25-61-35.SDR SWAA093932Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OVER, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR SWAA093925Slide · out of positionDURING SCHEDULED 2HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR IPXA09M56356Slide · inoperativeINSPECTION TYPE:N/A L1 DOOR SLIDE INOP. REMOVED AND REPLACED L1 SLIDE/RAFT PER MM 25-61-15-4. OPS CHECK PER MM 25-61-15-720- 002. OPS GOOD FOR SERVICE, THIS CLEARS M402658.SDR UALA2009061501680Slide · faultyINSTALL RT OFF WING SLIDE. REPLACED THE RT OFF WING SLIDE TO COMPLETION.SDR UALA2009061201671Lanyard · unsecureDOOR 1R SLIDE PACK RETAINER RING HANGING OUT OF COVER MAKING DOOR HARD TO CLOSE AND ARM. SECURED LANYARD AND DOOR CHECKS OKAY.SDR CA090625005Cable · broken(CAN) UPON ARRIVAL AT THE GATE, S/D MADE THE ANNOUNCEMENT TO DISARM DOORS. FA AT BACK DID SO AND CONTACTED THE SD TO SAY IT WAS DONE. UPON LEAVING THE ACFT, CREW HEARD A HISSING SOUND AS S/D TRIED TO ENTER THE R2 DOOR. ONCE SLIDE DEPLOYED BOTH CREW MEMBESDR UALA2009061201676Keeper · shearedFOUR (4) LATCH KEEPERS SHEARED FROM RIGHT OVERWING SLIDE DOOR. ALSO HAS 3 BROKEN HINGES. REPLACED RT OVERWING SLIDE DOOR.SDR SWAA093854Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.
Back to JASC 2565