duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA093855Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UALA2009061201673Slide · unserviceableLOW BOTTLE PRESSURE. LEAKING THROUGH FILLER VALVE PORT. THE FILLER VALVE NUT WAS NOT TIGHT. BOTTLE WAS REPLACED WITH A STOCK BOTTLE.SDR UALA2009061201672O-Ring · leakingNEEDLE ON BOTTLE ON LOW SIDE OF GREEN BAND. VERY SLOW LEAK AROUND GAUGE ADAPTER FITTING. REMOVED & REPLACED GAUGE ADAPTER O-RING.SDR UALA2009061101654Latch · wornRT OVERWING SLIDE DOOR LATCH NR 3 SLIDER WORN. INSTALLED NEW NR 3 DOOR LATCH; ADJUSTED, OPS CHECK GOOD.SDR UALA2009061101653Latch · wornRT OVERWING SLIDE DOOR LATCH NR 4 SLIDER WORN. REPLACED NR 4 DOOR LATCH, ADJ LATCH SYSTEM. OPS CHECKS GOOD.SDR SWAA093828Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA093793Holder · looseDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE CONTAINER AFT GIRT HOLDER LOOSE. SECURED HOLDER PER SRM.SDR UALA2009061001647Cartridge · out of toleranceNEED TO REPLACE THE LT OVERWING SLIDE MASTER CONTROL VALVE SQUIB. REPLACED THE LT UNFIRED MASTER CONTROL VALVE SQUIB. ACP SQUIB TEST, OPS CHECKED GOOD.SDR UALA2009060901636Aspirator · leakingASPIRATOR LEAKING FROM SEAL. NO EXTERNAL DAMAGE EVIDENT. REPLACED ASPIRATOR.SDR SWAA093778Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA093777Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA093761Slide · out of positionAFT DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA093760Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. REINSTALLED SLIDE PER MT.SDR IPXA09M56293Indicator · inoperativeINSPECTION TYPE:N/A LT CREW DOOR EVACUATION SLIDE PRESSURE IND INOP. REMOVED AND REPLACED IND PER MM 25-61-04-4. OK FOR SERVICE.SDR ZZDA2009189Slide · deployedL-1 DOOR SLIDE DEPLOYED. REMOVE AND REPLACED L-1 DOOR SLIDE.SDR UALA2009060801619Hook · disconnectedDOOR 2L SLIDE PAN COVER DETACHING FROM DOOR. FOUND DOOR 2L SLIDE RAFT LATCH HOOK DISCONNECTED FROM DOOR STRUCTURE LATCH BRACKET. SECURED SLIDE RAFT AND DOOR, OPS CHECK OKAY.SDR USAA2009060991447Line · frayedPIT - EES - S3 CHECK - L1 DOOR SLIDE MOORING LINE FRAYED. REPLACED L1 DOOR SLIDE IAW TASK CARD 26C83152008/001.SDR SWAA093723Slide · out of positionDURING SCHEDULED CV CHECK, FOUND L2 DOOR SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA093722Slide · out of positionDURING SCHEDULED CV CHECK, FOUND R1 DOOR SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA093632Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR USAA20090605BB097Slide · low pressurePHL - THE 2L DOOR SLIDE PRESSURE WAS FOUND LOW (RED). MAINTENANCE REPLACED 2L DOOR SLIDE.SDR USAA20090605BB096Light · inoperativePHL - THE 4L DOOR LIGHT INDICATION SLIDE ARMED IS INOP. MAINTENANCE RELAMPED 4L DOOR ARM INDICATION LIGHTS.SDR SWAA093701Slide · out of adjustDURING SCHEDULED 2HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR SWAA093623Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE PULLED OUT OF CONTAINER, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR SWAA093580Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR USAA2009060591405Slide Raft · unserviceablePIT - S3 - EES - L-2 DOOR SLIDE, GIRT BAR ATTACH LACING STRAP FRAYED AT PARACHUTE PIN LOCATION. REPLACED L-2 DOOR SLIDE IAW US AIRWAYS JOB CARD 26C83252008.SDR SWAA093576Slide · out of positionDURING SCHEDULED 14Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA093566Slide · low pressureDURING SCHEDULED MV1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATOR LOW. REMOVED AND REPLACED SLIDE PER MT.SDR HALA2009060200222Slide · unwanted deployLEFT OVERWING SLIDE PACK UNSERVICEABLE. INADVERTENTLY DEPLOYED DURING MX. R & R LT SLIDE PACK ASSY PER AMM 25-65-05. R & R LT SPOILER OVERRIDE ACTUATOR PER AMM 25-65-19. R & R RT SPOILER OVERRIDE ACTUATOR PER AMM 25-65-19 PG 401. R & R LT SLIDE OVERWING DSDR SWAA093676Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF COMPARTMENT, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR SWAA093555Slide · out of positionDURING SCHEDULED CV CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR UALA2009060301593O-Ring · leakingLOW PRESSURE. THERE WAS A SLOW LEAK AT THE VALVE BALL SHAFT O-RING. REMOVED & REPLACED O-RING AND BACK-UP O-RING.SDR UALA2009060301592Gauge · leakingLOW BOTTLE PRESSURE. THERE WAS A SMALL LEAK ON THE BACK OF THE PRESSURE GAUGE. REMOVED AND REPLACED PRESSURE GAUGE AND REFILLED BOTTLE.SDR UALA2009060201591O-Ring · leakingLOW PSI. LEAKING AT FILL VALVE. O-RING REMOVED & REPLACED. REFILLED CYLINDER.SDR UALA2009060101585Slide · unserviceablePRESSURE READING LOW. VERY SLOW LEAK AT BALL STEM O-RING. RESERVOIR ASSY WAS REPLACED WITH STOCK BOTTLE. O-RING WILL BE REPLACED AT VALVES TIME OF OVERHAUL.SDR USAA20090602BB094Slide · defectiveCLT - THE L2 DOOR SLIDE WOULD NOT ARM. REMOVED AND REPLACED THE L2 DOOR SLIDE.SDR UALA2009060101570Slide · faultyEMERGENCY LIGHT TEST FAILS SHOWING FWD LEFT EXTERNAL LOADS 10WL SHOWS EXTERIOR LIGHTS FAULT. THE 1L SLIDE IS BAD; VERIFIED WITH GOOD SLIDE. CORRECT SLIDE ON ORDER AOG V2048. REPLACED DOOR 1L SLIDE, TESTS OKAY.SDR ZZDA2009183Slide · out of positionL1 ESCAPE SLIDE FELL OUT OF COMPARTMENT WHEN MAIN DOOR OPENED. REMOVED AND REPLACED L1 DOOR SLIDE REF B717 M/M 25-61-01.SDR 22AA20090601Slide · deflatedREFERENCE TO ROUTINE WORK CARD 180M250K; ACCOMPLISH DOOR ESCAPE SLIDE/RAFT OPS CHECK ON L-1 DOOR. OPS CHECK FAILED TO INFLATE SLIDE, DUE TO THE WIRE THAT SENDS THE ELECTRICAL SIGNAL TORE OFF AND BROKE AND THE MANUAL WAS DISCONNECTED. DEPLOYMENT OK. REMOVED ANSDR SWAA093509Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE GIRT OUT OF POSITION. REMOVED AND REPLACED SLIDE PER MT.SDR USAA2009060191357Slide · faultyLOGPAGE:4520693 - FLT 528 - IAD-PHX - EMERGENCY EQUIPMENT - EMERGENCY LIGHTS FAIL SYSTEM TEST. REMOVED AND REPLACED L2 DOOR SLIDE PER JOBCARD R1C25305.SDR UALA2009052901544Aspirator · leakingASPIRATOR LEAKS. DAMAGED BARREL. REPLACED ASPIRATOR.SDR UALA2009052901539Slide · unlacedDOOR R2 SLIDE UNLACED. REPLACED SLIDE DEPLOY PEN.SDR SWAA093471Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT OF CONTAINER, DID NOT DEPLOY. REINSTALLED SLIDE PER MT.SDR USAA20090529BB093Lanyard · unsecureCLT - THE L1 DOOR SLIDE ATTACH CORD NEEDS RESTOWED. TIGHTENED AND SECURED THE L1 DOOR SLIDE COVER LANYARD.SDR USAA2009052891309Slide Raft · low pressureLOGPAGE:4366667 - FLT 1060 - CLT-DCA- EMERGENCY EQUIPMENT - L2 SLIDE RESERVOIR PRESSURE FOUND LOW. REMOVED AND REPLACED L2 SLIDE PER JOBCARD 26L00025001.SDR SWAA093461Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA093460Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA093421Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA093422Slide · out of adjustDURING SCHEDULED 2HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.
Back to JASC 2565