Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009050801319Slide · unserviceableLOW BOTTLE PRESSURE. PERFORMED LEAK TEST. COULD NOT FIND A LEAK. DISCHARGED THE BOTTLE AND VALVE WILL BE FULLY DISASSEMBLED AND REWORKED.SDR USAA2009050891119Lanyard · out of positionFLT 183 - PHX - EES - L1 DOOR SLIDE LANYARD EXPOSED AFTER DOOR CLOSED. MAINTENANCE RE-SECURED L1 DOOR SLIDE LANYARD.SDR CALA2009050700245Slide · low pressureR1 DOOR ESCAPE SLIDE PRESSURE IN RED BAND, FOUND DURING PRE FLIGHT CHECK. REMOVED AND REPLACED R1 DOOR SLIDE PER AMM 25-66-01, PAGE 401, REV JAN 28/01.SDR UALA2009050801318Ball Seat · leakingLOW BOTTLE PRESSURE. SMALL LEAK COMING OUT OF OUTLET PORT. REMOVED & REPLACED BALL SEAT.SDR UALA2009050701315O-Ring · defectiveBOTTLE LOW, BELOW GREEN BAND. BOTTLE LEAKS AROUND BALL STEM O-RING. REMOVED & REPLACED O-RINGS.SDR USAA2009050791113Slide Raft · defectiveFLT 117 - PHX - EMERGENCY EGRESS SYSTEM - CANNOT INSERT LOCKOUT PIN ON L1 DOOR SLIDE. MAINTENANCE REMOVED AND REPLACED THE L1 DOOR SLIDE.SDR USAA2009050791112Warning Light · faultyFLT 307 - PHX - EMERGENCY EQUIPMENT - CIRCUIT BREAKER P-11 TRIPPED IN FLIGHT, SLIDES/ARMED & WRN/FLT. MAINTENANCE FOUND CABIN PRESSURE WARNING LIGHT MODULE FIN 17WN1 FAULTING DOOR WARNING SYSTEM. REPLACED MODULE PER MM 52-73-22.SDR SWAA092865Slide · out of adjustDURING SCHEDULED 2HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR SWAA092863Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CASE, DID NOT DEPLOY. REMOVED AND REPLACED SLIDE PER MT.SDR USAA2009050591085Lanyard · misroutedFLT 645 - PHX - EMERGENCY EQUIPMENT - R2 DOOR SLIDE SURVIVAL KIT LANYARDS NOT PROPERLY ROUTED THROUGH GIRT BAR TRIGGER. MAINTENANCE PROPERLY ROUTED R2 DOOR SLIDE SURVIVAL KIT LANYARD AND RELEASE LANYARD.SDR USAA2009050591084Lanyard · misroutedFLT 645 -PHX - EMERGENCY EQUIPMENT - L1 DOOR SLIDE SURVIVAL KIT LANYARD NOT PROPERLY ROUTED THROUGH GIRT BAR RELEASE TRIGGER. MAINTENANCE ADJUSTED SLIDE LANYARD PROPERLY.SDR SWAA092866Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA092861Slide · looseR2 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MT.SDR DL757090825Slide · unwanted deployUPON ARRIVAL RIC FLT ATT OPENED L4 DOOR WITHOUT DE-ARMING. SLIDE AT L4 DOOR DEPLOYED SUCCESSFULLY. ATL MTC, REPLACED SLIDE AND BOTTLE.SDR SWAA092856Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA092842Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR CA090504004Slide · no test(CAN) DURING ESCAPE SLIDE FUNCTION CHECK ON RT SERVICE DOOR, SLIDE FAILED TO DEPLOY. ON SLIDE DEPLOYMENT DOOR PARTIALLY OPENED APPROX 6 INCHES-8 INCHES AWAY FROM FUSELAGE AND JAMMED. SLIDE WAS NOT FULLY UNLACED, FORCE WAS APPLIED TO HINGE ARM TO ASSIST DOOR OSDR SWAA092852Slide · out of positionDURING SCHEDULED MV2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MM.SDR SWAA092846Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA092845Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA092823Slide · looseDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR CLIP ON CASE FASTENERS LOOSE. REMOVED AND REPLACED SLIDE PER MT.SDR IPXA09M55745Cover · unsecureINSPECTION TYPE:N/A L1 DOOR SLIDE COVER NOT STOWED PROPERLY/UNSECURED. RE-SECURED L1 DOOR SLIDE COVER PER MM 25-23-07-4-1. ALL OPS NORMAL.SDR ZZDA2009144Slide · unserviceableTHE R1 DOOR SLIDE IS PARTIALLY OUT OF POUCH. REMOVED AND REPLACED R1 DOOR SLIDE PER 25-61-03 DUE TO BOTH INFLATION CABLE PINS PULLED.SDR SWAA092745Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA092744Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR 22AA20090404Slide · unwanted deployLOG PAGE NR 130754: L-1 DOOR INADVERTED OPENED (BY GROUND HANDLER) WHILE ARMED DEPLOYING SLIDE. ENTERED ON DMI NR 22611 IAW MEL 52-10-2, CATEGORY ''C''. REMOVED AND REPLACED L1 EVACUATION SLIDE/RAFT CONTAINER IN ACCORDING WITH DC-10 MAINTENANCE MANUAL 25-61-01SDR UALA2009042901244Attach Bracket · brokenACCOMPLISH DOOR 1 LEFT SLIDE REMOVAL INSTALLATION AND INSPECTION FOR TRAINING PURPOSES. DURING INSPECTION OF DOOR 1 LEFT SLIDE, FOUND FWD LOWER ATTACH BRACKET BROKEN. REPLACED BRACKET.SDR IPXA09M55720Light · illuminatedLEFT SIDE DOOR SLIDE/RAFT TEST LIGHT ILLUMINATED ON TAXI INTO CHOCKS. TRANSFERRED TO M399745 PER MEL 25-61-2. DMP 25-61-2 C/W. REPLACED L1 DOOR SLIDE/RAFT AS PER MM 25-61-15-4. REMOTE SLIDE INDICATOR CHECKS GOOD. THIS CLEARS ITEM M399745.SDR UALA2009042901232Slide · unserviceableASPIRATOR LEAKS. BARREL LEAKS, NO EXTERNAL DAMAGE, CAUSE UNKNOWN. REPLACED ASPIRATOR.SDR SWAA092700Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA092699Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR 2009F00033Slide · failedDURING FAA EVACUATION DEMO, THE FWD RT SLIDE FAILED TO INFLATE WHEN THE DOOR WAS OPENED. THE SLIDE DID HOWEVER INFLATE WHEN THE MANUAL INFLATION LANYARD WAS PULLED.SDR SWAA092674Slide · looseDURING SCHEDULED 2HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE LOWER FLAP LOOSE. SECURED SLIDE PER MM.SDR UALA2009042701203Attach Bracket · brokenDOOR L1 SLIDE LWR ATTACH BRACKET IS BROKEN. INSTALLED NEW ATTACH BRACKET.SDR SWAA092658Latch · defectiveR1 DOOR EMERGENCY EVAC SLIDE OUT OF ENCLOSURE. REMOVED AND REPLACED LATCH PER MM.SDR UALA2009042701198Latch · out of adjustLT OVERWING SLIDE COMPARTMENT DOOR FAILED LATCH TORQUE CHECK, TORQUE WAS IN EXCESS OF 250 IN. LB. INSTALLED 4 EA LATCHES AT LT SLIDE COMPT DOOR. LATCH ALIGNMENT CHECK GOOD. LATCH INSTALL TEST GOOD.SDR R61A20090020Slide · malfunctionedAT THE REQUEST OF BF GOODRICH REPUBLIC DEPLOYED LEFT PASSENGER DOOR SLIDE ON AC 132HQ IN CMH. SLIDE DEPLOYMENT WAS UNSATISFACTORY. WHEN DOOR OPENED SLIDE INITIALLY HUNG ON FWD LOWER CORNER OF THE DOOR AND WAS THEN PUSHED FROM INSIDE. SLIDE THEN DEPLOYED COMSDR SWAA092656Attach Bracket · brokenDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE AFT ATTACH BRACKET MOUNT BROKEN. REMOVED AND REPLACED BRACKET PER SRM.SDR UALA2009042401186Hose · unserviceableHYDROSTATIC HOSE DAMAGED. UNKNOWN POSSIBLE MANUFACTURING DEFECT. REPLACED HYDROSTATIC HOSE WITH A NEW ONE.SDR USAA20090424BB071Lanyard · unsecurePHX - THE LANYARD FOR SLIDE AT DOOR R1 NEEDS TO BE PROPERLY STOWED. THE LANYARD ON SLIDE AT DOOR R1 WAS STOWED.SDR SWAA092611Slide · out of positionL1 DOOR EVAC SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. REINSTALLED SLIDE ASSY PER MT.SDR SWAA092594Slide · out of adjustDURING SCHEDULED 2HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA092593Slide · out of adjustDURING SCHEDULED 2HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR ABXA200904280021Slide · deployedESCAPE SLICE PARTIAL DEPLOYMENT. DEFERRED 63559 INSTALLED BALLAST PER MEL PROCEDURE 52-11-4-2D & DEFERRED PER MEL CODE 8. BALLAST ASSEMBLY REMOVED AND SLIDE ASSEMBLY WAS INSTALLED.SDR USAA20090420BB069Lanyard · unsecurePHX - THE L4 DOOR SLIDE RAFT TETHER LINE FELL OUT OF SLIDE BUSTLE. VISUALLY INSPECTED DOOR L4. NO FAULTS FOUND. ALL SECURE.SDR USAA2009042290947Slide · misinstalledFLT 91 - PHX - EMERGENCY EQUIPMENT - L1 DOOR SLIDE / RAFT - LOGO OF SURVIVAL KIT LANYARD NOT PROPERLY ROUTED THROUGH RELEASE TRIGGER. MAINTENANCE REPLACED THE L1 DOOR SLIDE.SDR IPXA09M55627Slide · damagedL1 DOOR ESCAPE SLIDE AND ESCAPE SLIDE CONTAINER ASSY ARE BOTH DAMAGED. DEFERRED L1 DOOR SLIDE ASSY AS REMOVED IAW MEL 52-10-3-2. M399179. REMOVED AND REPLACED L1 DOOR SLIDE ASSY PER MM 25-61-01-4. THIS CLEARS M399179. PLACARD REMOVED.SDR NWAA 091309755Lanyard · misinstalledDURING A NON-ROUTINE, MAINTENANCE CHECK THE TAIL CONE EMERGENCY EVACUATION SLIDE DEPLOYMENT LANYARDS WERE FOUND TO BE CROSSED. CROSSED STRAPS COULD PREVENT THE PROPER OPERATION OF THE TAIL CONE SLIDE IN THE EVENT OF AN EMERGENCY. THE ROUTING OF THE LANYARDS SDR USAA20090420BB070Lanyard · unsecurePHX - THE TETHER CORD FOR SLIDE AT DOOR L4 IS COMING LOOSE FROM BENEATH THE SLIDE BUSTLE. RE-INSERTED THE CORD INTO THE SLIDE AT DOOR L4.SDR Q2SA758006Slide · unwanted deployPRIOR TO DEPARTURE FROM KJFK, LEFT UPPER DECK EMERGENCY EXIT SLIDE INADVERTENTLY DEPLOYED. REMOVED SLIDE IN ACCORDANCE WITH AMM 25-68-02. TRANSFERRED TO DEFERRED MAINTENANCE ITEM NR 18844 PER MEL 25-11, CAT. C. PLACARD INSTALLED.
Back to JASC 2565