Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009042001142Slide · out of toleranceNR 2R DOOR SLIDE OUT OF TOLERANCE. SLIDE WAS REPLACED.SDR UALA2009042101166Slide · faultyDOOR 2R SLIDE ARMED INDICATION INOP IN FLT. PERFORMED TSM TASK 52-13-0 0-810-809. REPLACED IND LT-SLIDE ARMED ASSEMBLY, AFT R DOOR (3WN 2), AND REPLACED 7WN2 PROX SW HANDLE, R AFT ESC SLIDE. PERFORMED OP-TEST OF EMERGENCY ESCAPE SLIDE RELEASE SYSTEM OF PASSSDR HALA2009041900160Slide · dislodgedAFTER ARRIVAL LT L-4 PASSENGER DOOR SLIDE RAFT FELL OFF AND RELEASED. DID NOT DEPLOY. INSTALLED SLIDE/RAFT TO L4 DOOR PER 767-3-205003. OK FOR SERVICE.SDR SWAA092498Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR SWAA092516Slide · unserviceableDURING SCHEDULED MV4 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATOR OUT OF LIMITS. REMOVED AND REPLACED SLIDE PER MT.SDR NOCA02309Slide · unserviceableFOUND L4 DOOR SLIDE PRESSURE INDICATION NEEDLE IN RED ZONE. REMOVED AND REPLACED L4 DOOR SLIDE AS PER AMM 25-66-01.SDR UALA2009041701120Aspirator · leakingASPIRATOR LEAKS. CAUSE IS UNKNOWN. NO SIGNS OF EXTERNAL DAMAGE. REPLACED ASPIRATOR.SDR UALA2009041601097Slide · faultyCABIN EMERGENCY LIGHT TEST FAILED. FAULTS \EXT LOADS AFT L. INSTALLED SERVICABLE CONTROLLER & BATTERY. RAN TEST STILL FAULTS 'EXT LOADS AFT L 33-51-38'. RETURNED ORIGINAL UNIT BACK TO ACFT, SUSPECT EMERGENCY SLIDE EITHER LT OR RT. REPLACED LT AFT DOOR SLISDR IPXA09155569Warning System · inoperativeEVACUATION SLIDE/RAFT RELEASE WARNING SYSTEM LIGHT INOP. DEFERRED PER A300 MEL 52-73-01-1. PLACARD INSTALLED. NO DMP M298941. RESEATED CONNECTOR ON AUTONOMOUS STANDBY POWER SUPPLY SYSTEM. OPS CHECKS GOOD. THIS CLEARS M398941. PLACARD REMOVED.SDR SWAA092465Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR Q2SA746010Slide · unwanted deployINADVERTENTLY DEPLOYED LEFT UPPER DECK SLIDE WHILE AIRCRAFT WAS ON GROUND AT KMIA. REMOVED SLIDE IN ACCORDANCE WITH AMM 25-68-02. TRANSFERRED TO DEFERRED MAINTENANCE ITEM NR 18822 PER MEL 25-11 (3). PLACARD INSTALLED.SDR USAA20090416BB068Strap · unsecureCLT - A STRAP WAS HANGING OUT OF THE BOTTOM OF THE SLIDE/DOOR WHEN THE L1 DOOR WAS OPEN. THE STRAP WAS PUT BACK INTO THE POUCH.SDR A6WA200940319Slide · failedSLIDE WAS REMOVED (R2 DOOR), ON 14-APR-09. THIS S/R WAS A SCHEDULED REMOVAL FOR TIME, AND WE COMPLIED WITH A "SAMPLE" ACTUAL DEPLOYMENT OF THE S/R IAW OUR MX PROGRAM REQUIREMENT. THE R2 PAX DOOR (ASSIST BOTTLE PRESSURE WAS CHECKED AND OK) OPENED CORRECTLY, ANDSDR SWAA092466Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA092421Slide · out of positionDURING SCHEDULED 2HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR USAA20090415BB065Lanyard · unsecurePHL - A STATIC LINE WAS LOOSE FROM THE SLIDE PACK AT THE R4 DOOR. MAINTENANCE SECURED THE STATIC LINE.SDR U30A2009041500004Slide · failedSLIDE WAS REMOVED (R2 DOOR), ON 14-APR-09. THIS S/R WAS A SCHEDULED REMOVAL FOR TIME, AND WE COMPLIED WITH A "SAMPLE" ACTUAL DEPLOYMENT OF THE S/R IAW OUR MX PROGRAM REQUIREMENT. THE R2 PAX DOOR (ASSIST BOTTLE PRESSURE WAS CHECKED AND OK) OPENED CORRECTLY, ANDSDR CALA2009041400201Slide · out of positionR-2 SERVICE DOOR GIRT BAR WILL NOT STAY SECURED IN HOLDERS. REPOSITIONED R-2 SLIDE WITHIN PACK IAW AMM 25-66-01-000-801, 25-66-01-400-8 03. OK TO CONTINUE.SDR USAA20090414BB064Lanyard · unsecureCLT - THE FORWARD ENTRY DOOR R1 IS DIFFICULT TO ARM. A CORD IS PROTRUDING UNDER THE EMERGENCY ESCAPE SLIDE COMPARTMENT. THE R1 GIRT BAR FLOOR FITTINGS WERE CLEANED AND LUBED. THE R1 DOOR SLIDE LANYARD WAS STOWED. OPERATIONS FOUND NORMAL.SDR SWAA092403Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA092315Slide · out of positionDURING SCHEDULED SPV CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR ZZDA2009112Slide · deployedFWD ENTRY DOOR (L1) DOOR ESCAPE SLIDE PACK ACTIVATED. REMOVED AND REPLACED FWD ENTRY (L1) ESCAPE SLIDE PACK REF B737 AMM 25-66.SDR USAA20090413BB063Lanyard · unsecureHNL - WHEN THE L4 DOOR ESCAPE SLIDE WAS DISARMED, A CHAIN AND BUCKLE FELL OUT. STOWED AND SECURED EXCESS CORD INTO SLIDE PACK.SDR AALA2009041000002Slide · unwanted deployMIA LEFT NUMBER ONE DOOR SLIDE INADVERTANTLY DEPLOYED AT HANGER. REPLACED LEFT NUMBER 1 DOOR SLIDE.SDR SWAA092397Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CASE, DID NOT DEPLOY. INSTALLED SLIDE PER MM.SDR SWAA092378Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA092371Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR USAA20090413BB062Slide · detachedLAS - THE R1 DOOR EMERGENCY ESCAPE SLIDE WAS FOUND DETACHED FROM THE DOOR. THE R1 DOOR EMERGENCY ESCAPE SLIDE WAS RE-ATTACHED TO THE DOOR.SDR SWAA092374Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR UALA2009040801020Slide · unserviceableLOW BOTTLE PRESSURE. NO LEAK FOUND WITH SPRAY BOTTLE LEAK TEST OR WITH WATER BATH TEST. VALVE WILL GET COMPLETE OVERHAUL.SDR SWAA092363Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR SWAA092307Slide · out of positionR2 DOOR EVAC SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MM.SDR SWAA092302Slide · out of adjustDURING HC2 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR IPXA09155435Button · lack of lubeINSPECTION TYPE:N/A EMERGENCY SLIDE TEST BUTTON SOMETIMES STICKS IN TEST. LUBRICATED SWITCH. OPS OK SEVERAL TIMES PER M/M 52-73-00-00.SDR SWAA092293Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MM.SDR SWAA092288Latch · lack of lubeDURING SCHEDULED MV2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE GIRT BAR DIFFICULT TO ARM. CLEANED & GIRT BAR FITTING LUBED LATCHES PER MM.SDR USAA20090408BB061Bearing · bindingCLT - THE R1 DOOR SLIDE WILL NOT ARM. THE BEARINGS FOR THE TORQUE TUBE OF THE SLIDE ARM MECHANISM WERE LUBED. OPERATIONALLY CHECK GOOD.SDR USAA20090408BB060Slide · loosePHL - THE L2 DOOR HANDLE WAS JAMMED. THE CREW COULD NOT DETERMINE IF THE EMERGENCY EVACUATION SLIDE WAS ARMED. THE SLIDE PACK WAS TIGHTENED TO THE DOOR. THE DOOR WAS CYCLED SEVERAL TIMES. NO DEFECTS WERE NOTED.SDR USAA20090408BB059Slide · stuckCLT - THE L2 DOOR HANDLE WAS JAMMED. THE CREW COULD NOT DETERMINE IF THE EMERGENCY ESCAPE SLIDE WAS ARMED. THE FORWARD SLIDER WAS STUCK ON THE FITTING. THE SLIDER WAS RELEASED FROM THE FITTING. THE DOOR WAS CYCLED SEVERAL TIMES. THE DOOR OPERATIONALLY CHESDR SWAA092251Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR USAA20090406SB048Slide · out of adjustPHX - FLIGHT ATTENDANT REPORTED THE GIRT BAR AT THE L1 DOOR WAS HARD TO GET IN AND OUT. MAINTENANCE REMOVED, ADJUSTED AND REINSTALLED THE L1 DOOR SLIDE IN ASSOCIATION WITH MM 25-61-35-2. OPERATIONAL CHECK GOOD.SDR DL757090632Slide · unwanted deployUNINTENTIONAL DEPLOYMENT OF L1 DOOR SLIDE BY CONTRACT CLEANING CREW AT THE GATE. REMOVED AND REPLACED L1 SLIDE AND ASSIST BOTTLE IAW AMM.SDR USAA2009040690805Slide · delaminatedFLT 91 - PDX-PHX - EMERGENCY EQUIPMENT - RIGHT OVERWING SLIDE DELAMINATED AT UPPER AFT CORNER. REMOVED AND REPLACED RIGHT OVERWING SLIDE IN ACCORDANCE WITH TASK CARD R1A25301.SDR MZZA2009040600036Latch · frayedL-1 DOOR ESCAPE SLIDE LATCH CABLE FOUND WORN. L-1 DOOR ESCAPE SLIDE LATCH REMOVED AND REPLACED IAW AMM 25-66-01, REV 38.SDR UALA2009040600990O-Ring · leakingLOW PRESSURE. LEAKING AT GAUGE. REMOVED & REPLACED GAUGE O-RING.SDR UALA2009040600989Gauge · leakingLOW PRESSURE. LEAKING FROM TOP OF GAUGE FAC THAT WAS BENT. REPLACED GAUGE.SDR CALA2009040300176Cable · frayedR-2 DOOR EMERGENCY ESCAPE SLIDE LATCH CABLE HAS BROKEN STRANDS. REMOVED AND REPLACED R-2 DOOR EMERGENCY ESCAPE SLIDE LATCH CABLE PER MM 25-61-35.SDR UALA2009040300952Slide · unserviceableLT OVERWING SLIDE FWD LACING CLIP BROKEN OFF AT THE UNLACE BAR. SLIDE NOT LACED AT POINT. REPLACED SLIDE ON SNR 6195 04016.SDR SWAA092089Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UALA2009040100938Cable · faultyLT AFT ESCAPE SLIDE STEP AFT CABLE IS WORN AND HAS A KNOT IN CABLE. *S/D* REPLACED AFT STEP CABLE.
Back to JASC 2565