Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA091376Slide · looseL1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MM.SDR UALA2009030200688Slide · faultyDOOR 1L SLIDE PRESSURE GAUGE. REMOVED AND REPLACED SLIDE-RAFT ASSY.SDR IPXA09M54876Cover · out of positionINSPECTION TYPE:N/A SLIDE GAUGE ON R1 DOOR HARD TO READ. ADJUSTED SLIDE COVER TO MKE GAUGE READABLE AS PER MM 25-61-15-4.SDR SWAA091357Slide · out of positionL1 DOOR EMERGENCY EVAC DOOR SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR USAA2009030290475Bottle · low pressureFLT 803 - PHL-CUN - EMERGENCY EQUIPMENT - R-2 DOOR EMERGENCY SLIDE BOTTLE PRESSURE LOW. SERVICED R-2 DOOR EMERGENCY SLIDE BOTTLE PER AIRBUS MAINTENANCE MANUAL 25-62-49.SDR AALA2009022700002Screw · looseMIA - RIGHT NUMBER ONE DOOR SLIDE FELL OUT OF HOUSING AND DID NOT DEPLOY. FOUND LOOSE SCREWS. REINSTALLED SLIDE AT RIGHT NUMBER ONE DOOR. SYSTEM GROUND CHECK NORMAL OPERATION.SDR SWAA091378Slide · detachedL1 DOOR EMERGENCY EVACUATION SLIDE DETACHED FROM COMPARTMENT. INSTALLED SLIDE PER MM.SDR USAA20090302BB043Light · inoperativePHX - THE SLIDE LIGHT FOR THE L2 DOOR WOULD NOT ILLUMINATE. MAINTENANCE CLEANED THE SENSORS AND REPLACED THE BULBS FOR THE L2 DOOR SLIDE INDICATION LIGHT.SDR IPXA09154860Indicator · unserviceablePRESSURE GAUGE ON ESCAPE SLIDE IS UNREADABLE. DEFERRED CABIN DOOR SLIDE PER MEL 52-11-01-03. PERFORMED DMP 52-11-01-03. CHECKED LEDGE ABILITY OF DOOR SLIDE PRESSURE GAUGE. OK FOR SERVICE AS PER MM 25-61-20-06.SDR DLM88090295Slide · unwanted deployFWD GALLEY 1R DOOR SLIDE DEPLOYED. REPLACED 1R DOOR SLIDE PER OPN 7035, S/N OFF - 1891, S/N ON - 0344.SDR SWAA091260Slide · out of positionL1 DOOR SLIDE FELL OUT OF CONTAINER. REPOSITIONED SLIDE ASSY PER MM.SDR UALA2009022400637Slide · faultyEPSU FWD LT HAS UNIT FAULT INDICATION WHEN TESTED. TESTED FOUND EXTERNAL LIGHT FAULT ILLUMINATED FOR DOOR 1LT ON ESPU. SUSPECT DOOR SLIDE ESCAPE LIGHTING TO BE AT FAULT. REPLACED SLIDE.SDR UALA2009022400629Proximity Switch · failedSLIDE LIGHT OVER 3L INOPERATIVE. REPLACED FWD PROXIMITY SWITCH S10223, OPS CHECKED OKAY.SDR WRLA2009062Slide · malfunctionedDURING LINE MAINTENANCE, R1 SLIDE WAS INADVERTENTLY DEPLOYED. SLIDE DID NOT DEPLOY CORRECTLY.SDR SWAA091330Slide · low pressureDURING SCHEDULED MV1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE NEEDLE IN THE RED RANGE. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA091259Slide · out of positionL1 DOOR SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. REINSTALLED SLIDE ASSY PER MT.SDR CALA2009022300105Cable Assy · frayedL-2 DOOR EMERGENCY ESCAPE SLIDE LATCH CABLE HAS BROKEN STRANDS. REPLACED L-2 DOOR EMERGENCY ESCAPE SLIDE LATCH CABLE PER MM 25-61-35.SDR UALA2009022300623Bottle · low pressureDOOR 2L SLIDE BOTTLE PRESSURE LOW. SERVICED BOTTLE.SDR UALA2009022300609Slide · faultyEMERGENCY EXIT LIGHT TEST FAILS FAULTING EXT LOADS AFT L. DOOR 2RT SLIDE CAUSING TEST TO FAIL, NEEDS SLIDE REPLACEMENT. REPLACED DOOR 2 RT ESCAPE SLIDE. ACCOMPLISHED EMERGENCY LIGHT TEST AND TEST PASSED.SDR UALA2009022300594Housing · faultyLEFT OVERWING SLIDE COMPARTMENT DOOR DISCONNECT HOUSING CENTER CROSS PIN NOT CENTERED AND BELLCRANK IS NOT SEATED. REPLACED DISCONNECT HOUSING. CABLE FREEDOM OF MOVEMENT CHECKS GOOD.SDR UALA2009022300593Latch · groovedLEFT OVERWING SLIDE COMPARTMENT DOOR LATCH NR 4 GROOVED, LIMITING OPERATION. INSTALLED NEW NR 4 LATCH.SDR UALA2009022300592Latch · groovedLEFT OVERWING SLIDE COMPARTMENT DOOR LATCH NR 3 GROOVED, LIMITING OPERATION. INSTALLED NEW NR 3 LATCH.SDR UALA2009022300591Latch · groovedLEFT OVERWING SLIDE COMPARTMENT DOOR LATCH NR 2 GROOVED, LIMITING OPERATION. REPLACED LT SLIDE COMP DOOR NR 2 LATCH.SDR UALA2009022300590Latch · groovedRIGHT OVERWING SLIDE COMPARTMENT DOOR LATCH NUMBER 3 IS GROOVED LIMITING OPERATION. REPLACED NR 3 COMP DOOR LATCH AT RT OVERWING SLIDE COMP DOOR. ALIGNMENT CHECK AND INSTALLATION TEST GOOD.SDR UALA2009022300589Housing · brokenRIGHT OVERWING SLIDE DOOR DISCONNECT HOUSING IS BROKEN. REPLACED RT OVERWING DISCONNECT HOUSING. CHECKED FREEDOM OF MOVEMENT, CHECKS GOOD.SDR UALA2009022000580Slide · deployedUPPER DECK ESCAPE SLIDE DEPLOYED. SLIDE REPLACED.SDR SWAA091220Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR SWAA091203Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR SWAA091202Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR UALA2009031000567Slide · unserviceableSB STENCILS ON GIRT; WITHOUT ACCOMPLISHMENT OF PACK BOARD COA 8-3436. PACK BOARD MODIFICATION NOT ACCOMPLISHED DURING LAST OVERHAUL. ACCOMPLISHED PACK BOARD MODIFICATION.SDR UALA2009022000849Slide · unserviceableSB STENCILS ON GIRT; WITHOUT ACCOMPLISHMENT OF PACK BOARD COA 8-3436. PACK BOARD MODIFICATION NOT ACCOMPLISHED DURING LAST OVERHAUL. ACCOMPLISHED PACK BOARD MODIFICATION. REPLACED SLIDE RAFT.SDR SWAA091163Slide · out of positionDURING SCHEDULED 26Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA091162Slide · out of positionDURING SCHEDULED 26Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA091159Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UPS09M54739Indication Sys · inoperativeINSPECTION TYPE:N/A L1 DOOR SLIDE PTT IND LIGHT INOP. REMOVED AND REPLACED L1 DOOR EVAC SLIDE PRESSURE IND KIT. SYS CHECKS OK M/M 25-61-04-5.SDR UPS09154741Slide · low pressureINSPECTION TYPE:N/A MAIN CABIN DOOR SLIDE INOP-PRESSURE INDICATION LOW. PERFORMED CHECK OF ESCAPE SLIDE INFLATION RESERVOIR PRESSURE GAUGE WITH REF TO A300 MM 25-61-20-06 PARA 1C(2). PRESSURE WITHIN MM LIMITS. OK FOR SERVICE. THIS CLEARS M394934 PLACARD RESDR UPS09154740Warning System · inoperativeCREW ENTRY DOOR EMERGENCY SLIDE WARNING INOP. RESET AUTONOMOUS POWER SUPPLY, HORN & LIGHT WARNINGS OPS CHECK OK. THIS CLEARS M395018.SDR F3LA2009021600027Cable · lack of lubeDURING C3 C-CHECK, INSPECTION NOTED THAT THE RIGHT OVERWING EMERGENCY SLIDE CABLE FAILED THE FUNCTIONAL TEST OF THE SLIDE RELEASE SIGNAL AND OPERATIONAL TEST OF THE UNLOCKING AND OPENING FROM THE OUTER SIDE IN THE ARMED MODE. MAINTENANCE INSPECTED AND LUBED CSDR USAA20090217BB036Slide · low pressureFLL - THE R2 DOOR SLIDE PRESSURE WAS FOUND OUT OF LIMITS. THE ACFT WAS MX FERRIED TO CLT, WHERE THE R2 DOOR EMERGENCY ESCAPE SLIDE WAS REPLACED. OK FOR SERVICE.SDR SWAA091141Slide · out of positionDURING SCHEDULED 24Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR USA09021690340Slide · defectiveEMERGENCY EQUIPMENT- EMERGENCY PWR SUPPLY UNIT EXTERNAL LOAD SLIDE ESCAPE LIGHTS INOPERATIVE. REMAINING LIGHTS POWERED BY EPSU OPERATE NORMALLY. MX REMOVED AND REPLACED L1 DOOR SLIDE. (K)SDR SWAA091139Slide · unserviceableDURING SCHEDULED MV2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATOR IN RED BAND. REMOVED AND REPLACED SLIDE PER MT.SDR UALA2009021800546Battery · faultyRIGHT EMERGENCY ESCAPE SQUIB WON'T TEST. REPLACED BATTERY FOR RT SYSTEM. OPS CHECKS NORMAL ON GROUND.SDR USA2009F00002Light · inoperativeTHE ARMED LIGHT ABOVE BOARDING DOOR L2 DOES NOT ILLUMINATE WHEN DOOR IS CLOSED AND ARMED. MX RELAMPED THE L2 DOOR ARMED LIGHT. OPS CHECK OK. (K)SDR ZZDA2009054Slide · unserviceableUPON A/C ARRIVAL NOTICED PARACHUTE PINS PULLED OUT OF L-1 DOOR SLIDE PACK. REMOVED AND REPLACED L-1 DOOR SLIDE PACK IAW AMM 25-61.SDR GTIA0900015Slide · failedDURING MAINTENANCE OPERATIONAL CHECK OF RT AFT PAX/CREW DOOR SLIDE DEPLOYMENT, THE SLIDE FAILED TO DEPLOY. REMOVED AND REPLACED SLIDE AS REQUIRED.SDR SWAA091113Slide · looseR2 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MM.SDR SWAA091106Slide · unserviceableDURING SCHEDULED 14Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE NEEDLE IN THE RED. REMOVED AND REPLACED SLIDE PER MM.SDR UPS09154709Bottle · lowON PREFLIGHT, FOUND MAIN CABIN DOOR EMERGENCY SLIDE PRESSURE LOW. NEEDLE IS WITHIN THE TEMPERATURE COMPENSATED GREEN SCALE. NO PROBLEM NOTED.SDR AALA2009021001023Slide · defectiveMIA - RETURNED TO GATE DUE TO LEFT NUMBER ONE DOOR SLIDE DISLODGED FROM MOUNT. FOUND GIRT BAR STUCK. DOOR DID NOT DISARM. REPLACED THE LEFT NUMBER ONE DOOR SLIDE RAFT ASSEMBLY. SYSTEM GROUND CHECK NORMAL OPERATION.
Back to JASC 2565