Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009021100460Slide · unwanted deployREPLACE RT OVERWING SLIDE ACCT DOOR OPENED AND ARMING CAM ROTATED. REPLACED RIGHT OVERWING ESCAPE SLIDE.SDR UALA2009021100453Slide · faultyCIDS CLASS 1 FAULT FOR ESPU EXT LOAD FWD L MESSAGE AFTER OPERATION TEST OF EMERGENCY LIGHTING SYSTEM. REPLACED 1R FWD SLIDE. SYSTEM CHECKED NORMAL.SDR SWAA091086Cover · damagedDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE COVER LATCH INOP. REMOVED AND REPLACED SLIDE PER MT.SDR ZZDA2009048Slide · discharged1 LT DOOR SLIDE PACK PRESSURE GAUGE IN RED. R&R L1 DOOR SLIDE. NO DEFECTS NOTED AT THIS TIME. REF. MM 25-61.SDR SWAA090992Slide · out of positionDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA090991Slide · out of positionDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR USAA20090209BB032Light · inoperativeDUB - THE R4 DOOR SLIDE ENGAGEMENT LIGHT REQUIRED A RELAMP. MAINTENANCE RELAMPED THE R4 DOOR SLIDE ENGAGEMENT LIGHT.SDR UALA2009020900421Light · faultyDOOR 1R SLIDE LIGHT ILLUMINATED WITH SLIDE DISARMED. VERIFIED PROPER OPERATION OF ARM AND DISARM FUNCTION. REPLACED LIGHT ASSY, OP CHECKED OKAY.SDR ZZDA2009043Slide · unsecureL1 SLIDE PACK NOT SECURE. A/C FERRIED TO ATL FOR REPLACEMENT. REMOVED AND REPLACED SLIDE PACK AS OUTLINED IN B717 AMM 25-61.SDR USAA20090206BB030Light · inoperativeCLT - THE GIRT BAR ENGAGEMENT LIGHT WAS EXTINGUISHED WITH THE EVACUATION SLIDE ARMED LEVER IN THE ARMED POSITION AT ENTRY DOOR L2. MAINTENANCE RELAMPED THE SLIDE LIGHT CAPSULE AND CLEANED THE GIRT BAR SLIDERS AT THE L2 DOOR. OPERATIONALLY CHECKS OK.SDR USAA20090206BB029Line · looseCLT - THE SLIDE/RAFT MOORING LINE AT DOOR L4 WAS FOUND LOOSE IN CABIN. MAINTENANCE STOWED THE RAFT MOORING LINE INTO THE SLIDE POUCH. OK FOR SERVICE.SDR SWAA090902Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA090901Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UALA2009020500398Slide · low pressureLOW PRESSURE. CHECKED FOR LEAKS. NO LEAKS FOUND. PRESSURE NEEDLE WAS ON HIGH SIDE OF GREEN BAND. RETURN TO SERVICE.SDR SWAA090899Slide · out of positionDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA090801Slide · out of positionL1 DOOR EMERGENCY EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA090785Slide · out of positionL1 DOOR EMERGENCY EVACUATION SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR USAA20090204BB027Light · inoperativePHL - THE R4 DOOR EMERGENCY ESCAPE SLIDE LIGHT WAS FOUND INOPERATIVE. MAINTENANCE RELAMPED THE R4 DOOR EMERGENCY ESCAPE SLIDE LIGHT.SDR USAA2009020490267Reservoir · faultyFLT 409 PHX-SFC - EMERGENCY EQUIPMENT - CIDS CAUTION CFDS MESSAGE SLIDE BOTTLE EMERGENCY R. MAINTENANCE REMOVED AND REPLACED THE SLIDE BOTTLE PER AIRBUS MAINTENANCE MANUAL 25-62-46-400-001.SDR SWAA090713Slide · out of adjustR2 DOOR EMERGENCY EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA090704Slide · out of adjustL1 DOOR EMERGENCY EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR USAABB09022Lanyard · unsecureMCO - THE 4L DOOR SLIDE WON'T ARM. MAINTENANCE STOWED SAFETY SLIDE LANYARD. SLIDE ARMED, OPERATIONAL CHECK OK.SDR UALA2009020200344Epsu · faultyCIDS SYS TEST FAILED DUE TO DOOR 1L SLIDE REPLACEMENT AND RE-INSTALLATION. BATTERY FAULT ON EPSU AT DOOR 1L. REPLACED BATTERY, NO HELP. SWAPPED EPSU FROM CENTER RIGHT AND PROBLEM FOLLOWED. SUSPECT BAD PART FROM STOCK. REPLACED EPSU BACK AT CENTER RIGHT. SDR USAABB09020Light · inoperativeBOS - THE R1 DOOR SLIDE "ARMED" LIGHT WAS FOUND INOPERATIVE. MAINTENANCE RELAMPED THE R1 DOOR SLIDE "ARMED" LIGHT, OPERATIONALLY CHECKS GOOD.SDR DLM88090123Slide · unwanted deployL-2 DOOR SLIDE ACCIDENTAL DEPLOYMENT WITH NO INFLATION. REMOVED OLD SLIDE PACK. INSTALLED NEW SLIDE PER AMM 25-62-00-201 FOR SERVICE.SDR SWAA090652Mount Bracket · crackedDURING SCHEDULED 16Y CHECK, FOUND R2 DOOR EMERGENCY EVACUATION SLIDE MOUNT BRACKETS CRACKED. REMOVED AND REPLACED BRACKET PER SRM.SDR SWAA090639Slide · low pressureR1 DOOR EMERGENCY EVACUATION SLIDE PRESSURE LOW. REMOVED AND REPLACED SLIDE PER MT.SDR USAABB09019Light · inoperativePHL - THE L4 DOOR GIRT BAR ENGAGEMENT LIGHT WAS EXTINGUISHED WITH THE EVACUATION SLIDE ARMING LEVER IN THE ARMED POSITION. MAINTENANCE RELAMPED THE 4L DOOR EVACUATION SLIDE LIGHT. OPERATIONALLY CHECKS OK.SDR SWAA090720Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR UALA2009013000338O-Ring · defectiveLOW BOTTLE. LEAKING AT GAUGE TO GAUGE ELBOW O-RING. REMOVED & REPLACED O-RING.SDR SWAA090640Slide · looseDURING SCHEDULED MV2 CHECK, FOUND R2 DOOR EMERGENCY EVACUATION SLIDE LOOSE. SECURED SLIDE PER MM.SDR UALA2009012800309O-Ring · defectiveLOW BOTTLE. LEAKING AT BALL SHAFT O-RING. REMOVED & REPLACED O-RING.SDR SWAA090596Slide · out of positionDURING SCHEDULED RON CHECK, FOUND R1 DOOR EMERGENCY EVACUATION SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. INSTALLED SLIDE PER MM.SDR UALA2009012700286O-Ring · leakingLOW BOTTLE PRESSURE. LEAKING AT BOTTLE TO VALVE O-RING. REMOVED AND REPLACED O-RING.SDR UALA2009012600279Support · unsecureDOOR 2L SLIDE BUSTLE FELL OFF. SECURED SLIDE BUSTLE.SDR UALA2009012600277Slide · faultyDOOR 2R WILL NOT FULLY ARM, HANDLE STICKS OUT .5 INCH CAUSING FLIGHT DECK INDICATIONS. FOUND WATER IN DOOR ARMING CABLE. REPLACED DOOR 2R CABLE AND SLIDE ASSY.SDR UALA2009012600274Slide · low pressureDOOR 2L SLIDE PRESSURE BELOW SERVICEABLE LIMIT. REPLACED 2L SLIDE.SDR USAA2009012690154Reservoir · inoperativeFLT 347 PHX-PVR - EMERGENCY EQUIPMENT - L2 SLIDE BOTTLE INDICATION ON FLIGHT ATTENDANT PANEL INOPERATIVE. MAINTENANCE REPLACED THE L2 SLIDE BOTTLE PER AIRBUS MAINTENANCE MANUAL 25-62-49. INDICATION ON FLIGHT ATTENDANT PANEL GOOD.SDR SWAA090508Cable · frayedDURING SCHEDULED 16Y CHECK, FOUND R2 DOOR EMERGENCY EVACUATION SLIDE CABLE FRAYED. REMOVED AND REPLACED SLIDE ASSY PER MM.SDR UALA2009012600268Lanyard · looseLANYARD LOOSE AT DOOR 1R. SECURED LANYARD.SDR USAABB09014Light · inoperativePHL - THE L2 DOOR ARMED LIGHT WAS FOUND INOPERATIVE. MAINTENANCE REPLACED BURNED OUT BULB ON L2 DOOR ARM INDICATOR.SDR MWEA090004Slide · no testTHE TAIL CONE SLIDE FAILED TO AUTOMATICALLY DEPLOY DURING TESTING IAW THE TASK CARD.SDR UALA2009012600265Housing · crackedLT OVERWING SLIDE DISCONNECT HOUSING CRACKED. INSTALLED NEW DISCONNECT HOUSING.SDR UALA2009012600261Housing · brokenRIGHT WING OVERWING SLIDE DOOR, DISCONNECT HOUSING IS BROKEN. REPLACED DISCONNECT HOUSING.SDR SWAA090556Slide · out of adjustDURING SCHEDULED MV2 CHECK, FOUND R1 DOOR EMERGENCY EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA090524Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EMERGENCY EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UALA2009012300250Barrel · leakingLEAKING ASPIRATOR. THERE IS NO EVIDENCE OF EXTERNAL DAMAGE TO THE BARREL. BARREL LEAKS IN BETWEEN BARREL AND SPRING. REPLACED BARREL.SDR SWAA090566Slide · out of adjustL1 DOOR EMERGENCY EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR SWAA090560Bracket · looseDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVACUATION SLIDE COVER FWD GIRT BAR ATTACH BRACKET LOOSE. SECURED BRACKET PER MM.SDR UALA2009012100229Lanyard · out of positionDOOR 3L WON'T ARM. *S/D* REMOVED LANYARD AROUND GIRT BAR AND REPOSITIONED.
Back to JASC 2565