SDR SWAA084783Slide · low pressureDURING SCHEDULED MV2 CHECK, L2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA084778Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084777Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA05507Contact · dirtyTHE R2 DOOR SLIDE IND LIGHT INOP, STAYS DIM. CONTACT AT INDICATOR LIGHT 2R DOOR IS DIRTY. CLEANED CONTACT AT DOOR 2R INDICATOR LIGHT, ALL OPS CHECKS NORMAL.SDR 2008UALA05491O-Ring · leakingDOOR 2R SLIDE PRESSURE BOTTLE LOOKS LOW. O-RING LEAKING FROM CENTER BALL SHAFT. REMOVED & REPLACED O-RING.SDR USAABB08141Slide · lowTHE R3 DOOR EMERGENCY ESCAPE SLIDE PRESSURE WAS FOUND LOW. MX REPLACED THE R3 DOOR EMERGENCY ESCAPE SLIDE. OK FOR SERVICE.SDR SWAA084760Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084756Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084755Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084754Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR AALA200802194Slide · failedMIA SLIDE AT LT NR 1 DOOR WAS NOT DISARMED AND PARTIALLY DEPLOYED. SLIDE FAILED TO INFLATE. REPLACED LT NR 1 DOOR SLIDE AND DOOR ASSIST BOTTLE. SYSTEM GROUND CHECKED NORMAL OPS.SDR ZZDA2008155Slide · damagedR1 SLIDE PACK COVER LOOSE AND COVER RIPPED BY CATERING. SLIDE COVER DAMAGED AND SLIDE PIN PULLED OUT OF R1 SLIDE. REMOVED AND REPLACED R1 SLIDE ASSY AND SLIDE COVER ASSY REF MM 25 61.SDR SWAA084737Slide · dischargedL1 DOOR EMERGECNY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA084723Slide · low pressureL1 DOOR EMERGECNY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR AALA200802189Slide · looseORD INFLIGHT T321/25AUG. AFT GALLEY SLIDE SLID DOWN DOOR. RETURNED TO ORD AND LANDED WITHOUT INCIDENT. REINSTALLED AFT GALLEY DOOR SLIDE PACK. SYSTEM GROUND CHECKED NORMAL OPS.SDR UPS08M53226Lever · inoperativeL1 DOOR ARM LEVER WILL NOT ARM. ADJUSTED LOWER DOOR INTERIOR COVER. OPS CHECK NORMAL. DOOR LIGHT EXTINGUISHED.SDR SWAA084698Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084680Slide · out of adjustDURING SCHEDULED RON CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084674Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084673Slide · low pressureDURING SCHEDULED 24Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR USAA920081566Slide · lowLOG PAGE 4420739 - FLT NR 352 - PHX - EES -R-1 DOOR SLIDE/RAFT PRESSURE LOW (BELOW GREEN BAND). MAINTENANCE REMOVED AND REPLACED R-1 DOOR SLIDE/RAFT.SDR SWAA084649Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA05418Latch · gougedRIGHT OVERWING SLIDE COMPARTMENT DOOR LATCH NR 3 SLIDER GOUGED. FOUND NR 3 LATCH GOUGED. REPLACED LATCH. OPS CHECKS GOOD.SDR 2008UALA05417Latch · gougedRIGHT OVERWING SLIDE COMPT DOOR LATCH NR 1 SLIDER GOUGED. FOUND NR 1 LATCH GOUGED. REPLACED LATCH. OPS CHECKS GOOD.SDR SWAA084669Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA05409Selector Switch · no testDOOR 4L SLIDE PACK ARM MODE SELECTOR SWITCH FAILED TEST PER JC 283507211. NO CONTINUITY ON DOOR ARMING CONDUIT. REPLACED DOOR OPEN SWITCH, REF 52-11-28-201. ACP EPAS BATTERY OPERATIONAL TEST, TEST IS OK. WORK IS ACP ON AMECO GFS112973.SDR SWAA084641Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084686Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2008UALA04369Housing · crackedLT OVERWING DISCONNECT HOUSING CRACKED. REMOVED & REPLACED DISCONNECT HOUSING.SDR SWAA084610Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084613Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA04343Slide · faultyTHE 'ESPU EXT LOAD FWD L' FAULT DISPLAYED ON PTP DISPLAY DURING EMERGENCY LIGHTING TEST. ISOLATED FAULT TO DOOR 1R ESCAPE SLIDE. INSTALLED NEW SLIDE PACK (MR25611) AT DOOR 1R.
SDR SWAA084620Slide · out of adjustDURING SCHEDULED MV3 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084587Cable · frayedDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE CABLE FRAYED. REMOVED AND REPLACED CABLE PER MM.SDR AALA200802123Pin · pulledATL FORWARD ENTRY DOOR SLIDE PINS WERE PULLED. REPLACED SLIDE AT FORWARD ENTRY DOOR. SYSTEM GROUND CHECKED NORMAL OPS.SDR 2008UALA04330Switch · intermittentDOOR 1L ARM LIGHT IS INTERMITTENT. REPLACED SWITCHS S10214 & S10215. OP CHECK NORMAL.SDR 2008UALA04312Relay · faultyRIGHT OVERWING SLIDE SQUIB TEST AT P61 FAILS. REPLACED 'R SLIDE TEST RELAY' K10487 AND TEST GOOD. ALSO REPLACED AND TESTED K10536 PRECAUTIONARY DUE TO AGE. OPS CK GOOD.SDR USAABB08135Slide · detachedCLT - THE L1 DOOR EMERGENCY ESCAPE SLIDE WAS FOUND NOT COMPLETELY ATTACHED TO THE DOOR. MAINTENANCE REPLACED THE L1 DOOR EMERGENCY ESCAPE SLIDE. OK FOR SERVICE. (S)SDR UPS08M53117Slide · malfunctionedSLIDE REMOVED DUE TO NOT ABLE TO DISARM SLIDE WITH INSIDE OR OUTSIDE ARMING HANDLE. FOUND AFT ARMING LATCHING CATCHING ON INSPECTION VIEWING WINDOW AT BOTTOM OF LWR COVER. ADJUSTED VIEWING WINDOW AND REINSTALLED L1 SLIDE ASSY IAW AMM 25-61-15-4. OK FOR SERVSDR PID2008F00013Bottle · no testRT OVERWING SLIDE BOTTLE LIGHT DOES NOT TEST ON P-61 PANEL. REMOVED RT OVERWING ESCAPE SLIDE BOTTLE AND SERVICED TO 2950 PSI WITH DRY NITROGEN. REINSTALLED RT OVERWING ESCAPE SLIDE BOTTLE IAW AMM 25-85-00. SLIDE BOTTLE PRESSURE LIGHT TESTS NORMAL. (S)SDR USAABB08134Slide · malfunctionedCLT - THE CABIN CREW FAILED TO DISARM THE L2 DOOR, RESULTING IN A PARTIAL EMERGENCY ESCAPE SLIDE DEPLOYMENT. MAINTENANCE REPLACED THE L2 DOOR EMERGENCY ESCAPE SLIDE. OK FOR SERVICE. (S)SDR SWAA084573Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA04328Bottle · dischargedDOOR 2L SLIDE BOTTLE DISCHARGED. REPLACED DOOR ASSIST BOTTLE.SDR 2008UALA04325Slide · malfunctionedEMERGENCY LIGHT TEST FAILS. FAULTS EPSU EXT LOAD AFT L. FOUND SLIDE AT FAULT. REPLACED DOOR 2L SLIDE.SDR SWAA084532Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR Q2SA783001Slide · unwanted deployDURING MAINTENANCE ACTIVITY IN SBKP, ACFT DOOR OPENED WITH FLOOR MOUNTED ESCAPE SLIDE HANDLE IN "AUTO", WHICH INADVERTENTLY ACTIVATED RT SIDE UPPER DECK SLIDE. NO DAMAGE CAUSED TO ACFT. SLIDE REMOVED IAW AMM 25-68-00/PG 201. TRANSFERRED TO DI 16944 IAW DDPGSDR SWAA084540Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084512Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084511Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR USAABB08132Slide · failedPHL - WHILE PARKED AT A REMOTE GATE, THE L1 DOOR WAS ACCIDENTALLY OPENED WHILE THE EMERGENCY EVACUATION SLIDE WAS STILL ARMED. THE SLIDE DEPLOYED, BUT DID NOT INFLATE. MAINTENANCE REPLACED THE EMERGENCY EVACUATION SLIDE AT THE L1 DOOR. OK FOR SERVICE. (S)