SDR 2008UALA04259Bottle · lowLOW BOTTLE.SDR SWAA084495Slide · low pressureR1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2008UALA04292Cover · cutFOUND DAMAGE TO SLIDE. BUSTLE TIE STRING CUT AND 3 INCH SLICE IN YELLOW SLIDE COVER. REPLACED DOOR 2L SLIDE.SDR SWAA084472Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084456Slide · low pressureL1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA084450Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2008UALA04254Slide · unsecureDOOR 1L SLIDE IS FALLING OUT. SUSPECT SLIDE IMPROPERLY INSTALLED. REINSTALLED SLIDE IAW MM 25-61-35 PG 201. AC OK FOR SERVICE.SDR USAABB08130Battery · failedARN - OPERATIONAL CHECK OF SQUIBS FOR EMERGENCY ESCAPE SLIDES FAILED. MAINTENANCE REPLACED THE RT OFF-WING SYSTEM POWER SUPPLY. OPERATIONALLY AND LEAK CHECKS OK. (S)SDR SWAA084430Slide · dislodgedR1 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. REPOSITIONED SLIDE ASSY PER MM.SDR 2008UALA04208Slide · out of positionUPPER DECK R DOOR WON'T ARM. IMPROPERLY INSTALLED SLIDE. REPOSITIONED SLIDE ASSEMBLY OP CHECK GOOD. AC OK FOR SERVICE.SDR SWAA084433Slide · dislodgedL1 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. RE-INSTALLED SLIDE ASSY PER MM.SDR AALA200802045Slide · failedSEA SLIDE WAS UNSUCCESSFULLY DEPLOYED FROM LT NR 1 DOOR WHEN OPENED FROM OUTSIDE. SLIDE PULLED OUT OF HARDPACK AND HANGING FROM GIRTH BAR. REPLACED SLIDE AND DOOR ASSIST BOTTLE. SYSTEM GROUND CHECKED NORMAL OPS.SDR SWAA084374Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084397Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVACV SLIDE PER MM.SDR SWAA084359Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084363Fitting · crackedDURING SCHEDULED 22Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT FITTING CRACKED. REMOVED AND REPLACED FITTING PER SRM.SDR 2008UALA04133Lanyard · unsecureDOOR 2L DIFFICULT TO DISARM. *S/D* LANYARD AND D-RING -WERE INTERFERING WITH GIRT BAR. SECURED LANYARD AND D-RING WERE INTERFERING WITH GIRT BAR. DOOR ARMS AND DISARMS NORMALLY.SDR 2008UALA04141Aspirator · leakingASPIRATOR LEAKS FROM BARREL. *S/D* FOUND LEAKING ASPIRATOR SUSPECT PACKING. REPLACED SLIDE ASSEMBLY. AC OK FOR SERVICE.SDR SWAA084354Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA084328Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA084326Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA084325Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR C772008F00000Slide · unwanted deployF/A INADVERTENTLY DEPLOYED DOOR R1 SLIDE WHILE ATTEMPTING TO ARM BEFORE TAXI. ACFT IS BEING DELAYED AND A NEW EMERGENCY EVACUATION SLIDE IS BEING INSTALLED PER THE AMM. (S)SDR 2008UALA04111Slide · low pressureDOOR 2R SLIDE PRESSURE LOW.
SDR SWAA084308Cable · misroutedDURING SCHEDULED 24Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED CABLE PER MM.SDR SWAA084301Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA084300Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084329Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA084267Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084370Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR KCSA081364Linkage · brokenESCAPE SLIDE RELEASE LINKAGE BROKEN ON LATCH SIDE (FWD). (A)SDR MWE2008F00029Lanyard · detachedLANYARD TO AFT SLIDE PACK DETACHED. REINSTALLED LANYARD. (K)SDR 2008UALA04047O-Ring · leakingLOW BOTTLE. GAUGE ADAPTER & RUPTURE DISK O-RING LEAKING. REPLACED WITH NEW.
SDR 2008UALA04050Slide · lowNR 1 RT MED SLIDE RAFT PRESSURE INDICATION NEEDLE IS AT LWR EDGE OF GREEN BAND. *S/D* UNKNOWN PRESSURE LEAK IN SLIDE. REPLACED NR 1 RT MED SLIDE RAFT.SDR 2008UALA04049Slide · lowNR 1 RT MED SLIDE PRESSURE INDICATOR IS AT LOW EDGE OF GREEN BAND. *S/D* UNKNOWN PRESSURE LEAK. REPLACED SLIDE ASSY, OPS CHECKED NORMAL.SDR 2008UALA04048Bottle · lowLOW BOTTLE. LEAKING AT FILL VALVE. REPLACED FILL VALVE.SDR 2008UALA04073Slide · no testCABIN EMERGENCY SLIDE CHECK DID NOT PASS.SDR SWAA084219Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA084217Slide · low pressureL1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2008UALA04008Slide · shortedFAILED EMERGENCY LIGHT TEST. *S/D* INTERNAL SHORT/RESISTANCE IN SLIDE 1L. REPLACED SLIDE 1L. OPS CHECKED GOOD.SDR 2008UALA04054Slide · lowDOOR 1L ESCAPE SLIDE PRESS IS NOT IN GREEN BAND.
SDR SWAA084204Cable · misroutedR2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED CABLE PER MM.SDR SWAA084172Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA084150Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR F3LA200800524Sensor · faultyFLIGHT CREW NOTED THE R2 DOOR INDICATION IS INOPERATIVE. WHILE CLOSED AND ARMED, THE ELECTRONIC CENTRALIZED AC MONITORING INDICATION IS AN AMBER BLOCK AND "SLIDE ARMED" INDICATION IS NOT ILLUMINATED. THIS DEFECT HAS BEEN DEFERRED (1063174) AND IS DUE ON 8/05SDR SWAA084163Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA084134Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA04023Latch · wornLT OVERWING SLIDE COMPARTMENT DOOR, NR 3 OPENING LATCH FAILS EDGE MARGIN MEASUREMENT. *S/D* FOUND WORN LATCH NR 3 DOOR. REPLACED NR 3 LATCH PER MM 25 -65-09, ADJ PER MM 25-65-09. AC OK FOR SERVICE.SDR USAA920081430Lanyard · unsecurePIT - EES - DROP IN MAINTENANCE - R2 DOOR SLIDE SAFETY LANYARD NOT SECURED. RE-RIG LANYARD. (S)SDR USAA92081431Lanyard · unsecurePIT - EES - DROP IN MAINTENANCE - L2 DOOR SLIDE SAFETY LANYARD NOT SECURED. RE-RIG LANYARD. (S)