SDR SWAA082614Slide · out of adjustDURING SCHEDULED SPV CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS08M52236Cover · unsecureINSPECTION TYPE:N/A L1 DOOR EMERGENCY ESCAPE SLIDE COVER NOT SECURED FLUSH AND RUBBING WHEN DOOR OPENED. RESECURED L1 DOOR SLIDE COVER IAW MM 25-23-07-4-1.SDR 2008UALA02711Slide · low pressureMAIN ENTRY DOOR 3R SLIDE PRESSURE LOW. SUSPECT FAULTY O-RING. REPLACED SLIDE ASSEMBLY PER AMM 25-66-01. OPS CHECK OK. AC OK FOR SERVICE.SDR SWAA082554Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA082552Cable · misroutedDURING SCHEDULED MV2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED CABLE PER MM.SDR USAA920081042Hose · collapsedC4 CHECK - RT WING ESCAPE SLIDE INFLATION HOSE AT SLIDE COMPARTMENT IS COLLAPSED. REMOVED AND REPLACED RIGHT WING ESCAPE SLIDE INFLATION HOSE AT SLIDE COMPARTMENT IAW AMM 25-65-02.SDR USAA920081041Slide · failedFLT 1165 PHL-CLT - EES - R3 DOOR SLIDE INTERNAL LIGHTING FAILED. EMERGENCY LIGHT EPSU EXTERNAL LOAD FAULT (EXIT R). MAINTENANCE REMOVED AND REPLACED THE R3 DOOR SLIDE ASSEMBLY. ALSO REFERENCE LOG PAGE 4388428 FOR EMERGENCY LIGHTS FAILED CIDS TEST - MSGS (1)SDR 2008UALA02693Hose · collapsedRIGHT OVERWING SLIDE INFLATION HOSE COLLAPSED. SUSPECT AC MAINTENANCE. REPLACED HOSE ASSEMBLY. AC OK FOR SERVICE.SDR 2008UALA02749Girt Bar · obstructedDOOR 1R WILL NOT ARM. DEBRIS UNDER GIRT BAR. CLEANED DEBRIS, STOWED LANYARD AND DOOR ARMS/DISARMS NORMALLY.SDR 2008UALA02743Slide · low pressureNR 1L DOOR ESCAPE SLIDE BOTTLE PRESSURE LOW. FOUND DURING NR 3 SERVICE. REPLACED SLIDE, TESTS GOOD.SDR 2008UALA02718Lanyard · out of positionNO LANYARD VISIBLE ALL 4 DOOR SLIDES. REPOSITIONED LANYARD ON AL L SLIDES, OK FOR SERVICE.SDR 2008UALA02688Slide · faultyDOOR 1R GIRT BAR NOT SECURING PROPERLY. SUSPECT FAULTY DOOR SLIDE ASSEMBLY. REPLACED DOOR SLIDE ASSEMBLY IAW MM 25-61-35. AC OK FOR SERVICE.SDR USAA920081030Slide · failedPIT - EES - C11 CHECK, R1 DOOR SLIDE FAILED OPERATIONAL CHECK. TIME REQUIRED TO FULLY INFLATE WAS 22 SECONDS AND THE LIGHTS DID NOT ILLUMINATE . REPLACED SLIDE.SDR SWAA082521Strap · brokenDURING SCHEDULED 16Y CHECK, FOUND L2 DOOR EVACUATION SLIDE CONTAINER RETAINING STRAPS BROKEN. REMOVED AND REPLACED RETAINING STRAPS PER SRM.SDR 2008UALA02675Spring · faultyDEPLOYMENT BAR SNUBBER DOES NOT RETRACT BAR ON L1 DOOR. SUPPLEMENTAL DATA UPDATE, REPLACED GAS SPRING. OPS CHECKS GOOD.SDR 2008UALA02672Strap · out of positionSTRAP HANGING OUT OF SLIDE PACK AT 2L. SECURED D-RING STRAP.SDR SWAA082502Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA02648Slide · out of positionRT OVERWING SLIDE PACK FOUND UNLEASHED. SUPPLEMENTAL DATA UPDATE, UNKNOWN DAMAGE. REPLACED SLIDE PACK.SDR 2008UALA02682Window · missingAFT GALLEY DOOR SLIDE MISSING PRESS GAUGE WINDOW. NEW WINDOW INSTALLED PER GNMM 6-0-2-50.AC OK FOR SERVICE.SDR 2008UALA02645Slide · out of positionFWD ENTRY DOOR SLIDE IS HANGING OUT OF COVER ASSY. REINSTALLED SLIDE REF MM 25-61-35. AC OK FOR SERVICE.SDR SWAA082500Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA082473Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA02630Slide · reads lowSLIDE PRESSURE AT DOOR 1R SHOWS ON RED. REPLACED SLIDE.SDR 2008UALA02680O-Ring · leakingLOW BOTTLE PRESSURE. REPLACED O-RINGS IN VALVE ASSEMBLY. AC OK FOR SERVICESDR 2008UALA02644Slide · low pressureSLIDE PRESS AT DOOR 1R SHOWS ON RED. REPLACED SLIDE.SDR 2008UALA02633Lanyard · unsecureDOOR 4R WILL NOT ARM. FOUND SLIDE LANYARD INTERFERING. SECURED LANYARD, OPS ARMS/DISARMS NORMALLY.SDR SWAA082452Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA082451Slide · out of adjustDURING SCHEDULED 12Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA082446Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA082445Slide · low pressureDURING SCHEDULED MV2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2008UALA02605Slide · faultyDOOR 4R SLIDE BOTTLE PRESSURE IS ONE NEEDLE WIDTH TO THE LEFT OF THE GREEN BAND. SLIDE BOTTLE PRESSURE IS LOW. AFTER SETTING FOR TWO HRS NEEDLE AT END OF GREEN BAND WITHIN CF LIMITS, SLIDE WAS SCHEDULED TO BE REPLACED.SDR 2008UALA02594Slide · unsecureDOOR 1 LEFT SLIDE FELL OUT DURING DOOR OPERATION. REINSTALLED DOOR 1 LEFT SLIDE ASSEMBLY PER 25-61-35. AC OK FOR SERVICE.SDR SWAA082396Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS08852167Slide · inoperativeWITH MAIN DOOR SHUT AND SLIDE ARMED, DOOR WAS OPENED AND SAFETY WIRE REMOVED FROM SLIDE HOUSING. REMOVED AND REINSTALLED MAIN CABIN DOOR ESCAPE SLIDE IAW AMM 25-60-01-2. INSTALLATION CHECK WAS GOOD.SDR SWAA082407Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA082400Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR MWEA080066Fastener · failedDURING TAIL CONE SLIDE DEPLOYMENT TEST, TAIL CONE SLIDE FAILED TO DEPLOY WHEN TAIL CONE WAS RELEASED FROM AIRCRAFT. FOUND DEFECTIVE SNAP ON STRAP ASSEMBLY, REPLACED.SDR SWAA082412Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR ZZDA2008101Slide · unwanted deployTAIL CONE AND TAIL SLIDE INADVERTENTLY DEPLOYED. REINSTALLED TAIL CONE ASSEMBLY REF MM 53-52-01. A/C FERRIED TO ATL FOR FURTHER MAINT. REINSTALLED NEW TAIL CONE SLIDE PER MM 25-61.SDR UPS08852147Slide · unsecureMAIN CABIN DOOR SLIDE NOT SECURE. RESECURED SLIDE HALVES AND SLIDE COVER TO ENTRY DOOR PER MM 25-60-01-2.SDR 2008UALA02537Slide · faulty1L SLIDE PRESS IS IN THE RED. REPLACED SLIDE PACK.SDR 2008UALA02542Slide · damagedDOOR 1L SLIDE-RAFT GIRT RUBS ON FLOOR AFTER INSTALLATION AND GIRT IS FRAYED. FOUND WEAR AND IMPROPER LANYARD INSTALLATION. REPLACED SLIDE.SDR UPS08M52124Slide · unwanted deployDURING POST FLT CLEAN UP RT (R-1) EMERGENCY EVAC SLIDE WAS DEPLOYED AND EMERGENCY PNEUMATIC DOOR BOTTLE DISCHARGED (M374716 ASSIGNED. REPLACED RT FWD CREW ENTRY DOOR EVACUATION SLIDE PER MM 25-61-51-4, SERVICED EMERGENCY PNEUMATIC BOTTLE PER MM 12-25-04-3. MSDR USAA920080975Slide · low pressureFLT 640 - PHX - EES - R-1 DOOR SLIDE PRESSURE INDICATOR IS APPROX 1/8 OUT OF GREEN BAND. MAINTENANCE REMOVED AND REPLACED THE R-1 SLIDE.SDR SWAA082327Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA02575O-Ring · leakingESCAPE SLIDE HAS A LOW BOTTLE. BOTTLE TO VALVE O-RING LEAKING. REPLACED O-RINGSDR SWAA082368Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA082316Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR BB08072Slide · low pressurePHX - THE R2 DOOR EMERGENCY ESCAPE SLIDE PRESSURE WAS FOUND TO BE IN THE RED. MAINTENANCE REPLACED THE R2 DOOR EMERGENCY ESCAPE SLIDE. OK FOR SERVICE.SDR 2008UALA02507Slide · dislodgedDOOR 1L SIDE FELL OUT OF PACK. REPLACED SLIDE WITH SERVICEABLE UNIT.
Back to JASC 2565