Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA02480Slide · misinstalledDOOR SLIDE 2RH SLIDE PACK COMING UNHOOKED ON FWD SECTION OF SLIDE PACK. IMPROPERLY INSTALLED DOOR SLIDE. REPLACED SLIDE PACK ASSY REF MM 25-66-01. AC OK FOR SERVICE.SDR 2008UALA02457Shear Pin · shearedFOUND DOOR 1 LEFT DOOR BOTTLE LOW AND SHEAR PIN, SHEARED IN REF TO SLIDE PACK ON JET WAY. REPLACED DIAPHRAGM AND SHEAR PIN AND SERVICED BOTTLE PER MM. ALSO REPLACED WITH SERVICABLE SLIDE.SDR 2008UALA02478Slide · defectiveNEW SLIDE FOR DOOR 2 RT BECAME UNRAVELED. SLIDE IS IN ACFT NOT INSTALLED. SUSPECT IMPROPERLY PACKED SLIDE. REPLACED SLIDE PER MM 25-66-01. AC OK FOR SERVICE.SDR 2008UALA02475Light · looseFOUND DOOR 3L SLIDE ARMED LIGHT INOP. FOUND LIGHT ASSY LOOSE. SECURED LIGHT ASSY AND ARMED DOOR AND LIGHT CAME ON.
SDR 2008UALA02479Housing · crackedRIGHT EMERGENCY EXIT SLIDE DISCONNECT HOUSING IS BROKEN (CRACKED). FOUND DISCONNECT HOUSING CRACKED. REPLACED DISCONNECT HOUSING IAW MM 25-65-98 FREEDOM OF MOVEMENT CHECK GOOD IAW MM 25-65-04.AC OK FOR SERVICE.SDR 2008UALA02436Latch · faultyRT OVERWING EMERGENCY SLIDE NR 1 LATCH IS HARD TO OPERATE. SUSPECT FAULTY BEARING. REPLACED NR 1 HATCH AT RT OVERWING SLIDE COMPT DOOR PER MM 25-65-09 ALIGNMENT CHECK GOOD IAW MM 25- 65-09.AC OK FOR SERVICE.SDR SWAA082222Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA082221Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 08FDEA01523Slide · crackedR-1 DOOR SLIDE ASSY, BOX IS CRACKED ON THE OUTER SURFACE, UPPER FWD SIDE. RECEIVED SERVICEABLE SLIDE TO BE INSTALLED ON W/C 68S1500CP; STEP 5-B.SDR 08FDEA01521Door Frame · crackedL-1 DOOR SLIDE ASSY; LOWER INTERNAL FRAME IS CRACKED AT THE FWD CORNER. NEW SERVICEABLE SLIDE RECEIVED. INSTALLED ON WIC 68S5001CP.SDR SWAA082158Slide · frayedDURING SCHEDULED 16Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE GIRT BAR CANVASS FRAYED AND WORN. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2008UALA02409Slide · damagedLT OVERWING ESCAPE SLIDE FOUND UNLACED. REPLACED EMERGENCY SLIDE.SDR 2008UALA02406O-Ring · leakingCREW REPORTS 1R DOOR SLIDE LOW PRESSURE. SUSPECT FAULTY O-RING.REPLACED 1R DOOR SLIDE ASSEMBLY REF MM 25-66-01.AC OK FOR SERVICE.SDR AALA200801043Slide · failedDFW - RIGHT NUMBER TWO DOOR SLIDE UNSUCCESSFULLY DEPLOYED. RIGHT NUMBER TWO DOOR FAILED TO DISARM AT GATE AND SKYCHEF SLOWLY OPENED DOOR. SLIDE FELL OUT OF PACK AND DID NOT DEPLOY. REPLACED SLIDE AND POWER ASSIST BOTTLE FOR RIGHT NUMBER TWO DOOR. SYSTEM GRSDR SWAA082142Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA082139Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR MWEA080058Pin · pulledFOUND FORWARD SERVICE DOOR ESCAPE SLIDE INFLATION CABLE PINS PULLED OUT OF SLIDE. REMOVED AND REPLACED SERVICE DOOR ESCAPE SLIDE.SDR SWAA082133Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA082132Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA02334Bottle · reads lowLOW BOTTLE. SUPPLEMENTAL, FILLER VALVE LOOSE. TIGHTENED FILLER VALVE AND TOPPED OFF CYLINDER.SDR USAA920080907A/C Pack · detachedA-9 CK LAX - EES - R-2 SLIDE RAFT FWD COVER ASSEMBLY STRAP IS DETACHED FROM THE SLIDE ASSEMBLY. MAINTENANCE REMOVED AND REPLACED THE R-2 SLIDE/RAFT.SDR 2008UALA02323Slide · shortedEMERGENCY LIGHT TEST RESULT SHOW 'EXT LOAD AFT L' AT FAULT. FOUND RT AFT SLIDE SHORTED INTERNALLY. REPLACED RH AFT SLIDE AND RETESTED EMER LIGHTS SYSTEM OK
SDR SWAA082123Slide · wornDURING SCHEDULED 16Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE GIRT BAR CANVASS WORN. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA082080Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA082120Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA082077Bracket · crackedDURING SCHEDULED 16Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT SLIDE BRACKET CRACKED. REMOVED AND REPLACED BRACKET PER MM.SDR USAABB08065Light · inoperativeCLT - THE R4 DOOR SLIDE GIRT BAR ENGAGEMENT LIGHT WAS FOUND INOPERATIVE. MAINTENANCE PLACED THE SYSTEM ON MEL. MAINTENANCE REPLACED THE R4 DOOR SLIDE INDICATION LIGHT ASSEMBLY AND CLEARED THE MEL.SDR 2008UALA02335O-Ring · leakingLOW BOTTLE. SUPPLEMENTAL, GAUGE FITTING BACK UP RING LEAKS. REPLACED BACK UP RING.SDR 2008UALA02333Slide · will not armFOUND DOOR 3R WILL NOT ARM. ADJUSTED/REPAIRED DOOR 3R, OPS CHECKED GOOD, ARMS/DISARMS NORMALLY.SDR SWAA082102Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA082081Slide · low pressureL1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR USAA920080904Slide · lowFLT NR 9186 PIT - EES - AFT LT SERVICE DOOR SLIDE HAS LOW PRESSURE. MAINTENANCE REMOVED AND REPLACED THE AFT LT SERVICE DOOR SLIDE.SDR 2008UALA02274Aspirator · damagedSLIDE HAS A DAMAGED ASPIRATOR. BARREL IS BENT FROM EXTERNAL PRESSURE OR CONTACT. NO VISIBLE DAMAGE TO SLIDE MATERIAL. REPLACED ASPIRATOR.SDR SWAA082057Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA082037Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA082069Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2008UALA02181Hose · shearedNR 2 RT MAIN ENTRY SLIDE DEPLOYMENT TEST FAIL, INFLATION HOSE SHEARED OFF AT THE ASPIRATOR END FITTING. REPLACED HOSE AND OVERHAULED SLIDE.SDR SWAA082017Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR WRLA2008044Slide · dislodgedL1 DOOR SLIDE DROPPED OUT WHEN DOOR OPENED PNEUMATICALLY, SLIDE DID NOT DEPLOY CORRECTLY. REMOVED AND REPLACED SLIDE ASSY IAW MM 25-61-01. SERVICED PNEUMATIC DOOR ASSIST.SDR SWAA081992Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA02157Slide · inoperativeDOOR 1L ARMED LIGHT DOES NOT COME ON. REPLACED DOOR 1L SLIDE LIGHT ASS'Y. OPS CK NORMAL.SDR 2008UALA02139Slide · out of position1R DOOR ESCAPE SLIDE SLID OUT OF CONTAINER. ACCOMPLISHED INSPECTION OF DOOR SLIDE INSTALLATION DOOR 1R SLIDE CHECKED NORMAL. AC OK FOR SERVICE.SDR CALA0800330Latch · frayedR-2 DOOR ESCAPE SLIDE LATCH CABLE HAS BROKEN STRANDS. REPLACED SLIDE CABLE P/N 65C19901-15 PER 737-3/5 MM 25-61-35.SDR 2008UALA02136Squib · noneRIGHT NUMBER ONE EMERGENCY ESCAPE SLIDE DOES NOT TEST ON SQUIB PANEL. TESTED SQUIB 20 TIMES, OPS CHECKS GOOD EVERY TIME.SDR BB08059Slide · low pressurePHL - THE R3 DOOR EMERGENCY ESCAPE SLIDE BOTTLE PRESSURE WAS LOW. MAINTENANCE REPLACED THE EMERGENCY ESCAPE SLIDE AT DOOR R3. OK FOR SERVICE.SDR BB08058Slide · low pressurePHL - THE EMERGENCY ESCAPE SLIDE BOTTLE PRESSURE AT DOOR R3 WAS LOW. MAINTENANCE REPLACED THE R3 DOOR EMERGENCY ESCAPE SLIDE. OK FOR SERVICE.SDR SWAA081958Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA02178O-Ring · unserviceableLOW BOTTLE. FOUND FAULTY O-RING. REPLACED O-RING.SDR SWAA081933Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS08152015Warning Light · malfunctionedINSPECTION TYPE:N/A RED SLIDE WARNING LIGHT IS INOP. AURAL HORN TESTS OK. PERFORMED ADJUSTMENT/TEST EMERGENCY ESCAPE SLIDE RELEASE WARNING LIGHT, AURAL HORN OPERATING NORMALLY AT THIS TIME. OK FOR SERVICE IAW MM 52-73-00-05.
Back to JASC 2565