SDR SWAA081973Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA081956Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA081912Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA02079Lanyard · unsecure1R WILL NOT ARM. FOUND SLIDE LANYARD INTERFERENCE. SECURED LOOSE RAFT LANYARD, DOOR ARMS/DISARMS NORMALLY.SDR 2008UALA02077Cover · misinstalledDOOR 2L SLIDE COVER MIS-INSTALLED. REMOVED SLIDE AND REPLACED IT WITH CORRECT SLIDE FOR THAT POSITION.SDR 2008UALA02069Slide · reads lowDOOR R1 SLIDE PRESSURE LOW. REPLACED SLIDE R1, PRESSURE OK.SDR 2008UALA02046Hose · kinkedLT OVERWING SLIDE-BOTTLE PRESSURE HOSE IS KINKED SEVERAL SPOTS. SUSPECT HOSE MIS- STOWED DURING MAINTENANCE. REPLACED HOSE IAW SB 767-25-022. AC OK FOR SERVICE.SDR 2008UALA02032Aspirator · leakingASPIRATOR LEAKS. REPLACED ASPIRATOR LEAK CHECKED GOOD. AC OK FOR SERVICE.SDR WRNA20080011Slide · no testDURING OPERATIONAL TEST, THE R-1 DOOR ESCAPE SLIDE/RAFT FAILED TEST, DID NOT FULLY INFLATE. REPLACED ESCAPE SLIDE/RAFT CONTACTED MAINTENANCE STATION WERE TEST WAS ACCOMPLISHED. SLIDE BOTTLE PRESSURE INDICATOR WAS IN THE 'GREEN', SLIDE DEPLOYED BUT DID NOT FUSDR SWAA081872Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA081865Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA081848Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR AALA200800819Slide · dislodgedORF - EMERGENCY SLIDE AT LEFT NUMBER ONE DOOR DISLODGED WHEN DOOR OPENED WITHOUT BEING DISARMED. SLIDE DID NOT INFLATE. DOOR NOT OPENED ENOUGH TO TRIGGER INFLATION OF SLIDE. REPLACED LEFT NUMBER ONE DOOR EMERGENCY SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATSDR SWAA081816Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR ZZDA2008087Slide · unserviceableL1 DOOR SLIDE PRESSURE OUT OF LIMITS. REMOVED AND REPLACED L1 DOOR SLIDE REF B717 M/M 25-61-01.SDR 2008UALA01981Lanyard · out of positionFLIGHT ATTENDANT COULD NOT ARM DOOR ONE RIGHT BEFORE PUSHBACK. FOUND LANYARD OUT OF POSITION, INTERFERING WITH MECHANSIM. RESTOWED LANYARD ROPE. DOOR 1R ARMS DISARMS OK.SDR SWAA081836Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR HALA0800490Slide · looseL4 DOOR SLIDE PARTIALLY UNPACK. REMOVED AND REPLACED 4L EVAC DOOR SLIDE PER TASK CARD 767-3-205003.SDR SWAA081801Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA081793Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA081792Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA01879Cylinder · low pressureAFT GALLEY DOOR EVAC SLIDE INFLATION CYLINDER PRESS GAUGE BELOW GREEN BAND. FAULTY RELEASE VALVE SEAL. REPLACED THE AFT GALLEY DOOR EVACUATION SLIDE REF MM 25-61-35 PAGE 202. AC OK FOR SERVICE.SDR UPS08851961Gauge · unserviceableESCAPE SLIDE TO BE REPACKED. PRESSURE GAUGE IS UNREADABLE. REPACKED ESCAPE SLIDE PER DC8 MM 25-60-01-2. OK FOR SERVICE.SDR SWAA081782Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA01862Seal · leakingNR 3 LEFT MED SLIDE SHOWS NEEDLE BELOW GREEN BAND. DISCHARGE VALVE SEAL LEAKING. REPLACED NR 3 LT ESCAPE SLIDE. AC OK FOR SERVICE.SDR UPS08851952Bracket · brokenFWD LT CREW ENTRY DOOR BOTTOM BRACKET ON SLIDE CASE IS BROKEN CASE SLIDE WILL NOT CLOSE AND SECURE. DEFERRED PER MEL 34-7-4, M 372532. INSTALLED, INSTALLED EMER EVAC SLIDE PACK IAW 25-60-01-2. THIS CLEARS M-372532.SDR CALA0800286Slide · unserviceableCABIN - R3 EMERGENCY DOOR SLIDE PACKING TOO LOOSE. BUSTLE CANNOT FIT PROPERLY. CABIN - R3 EMERGENCY DOOR SLIDE ASSY REPLACED AS PER AMM 25-66- 10. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1270979 SN OFF 00301 SLIDE, B767-400 OFF 64-2566-9-0006 0301 ON 64-2SDR UPS08851951Lanyard · disconnectedINSPECTION TYPE:N/A EMERGENCY SLIDE WILL NOT ATTACH TO FLOOR. DEFERRED IAW MEL 52-7-4, M372513 INSTALLED. RECONNECTED INFLATION LANYARD TO QUICK - DISCONNECTION FITTING IAW MM 25-60-01-2. THIS CLEARS M372513. REMOVED PLACARD.SDR 2008UALA01828Slide · low pressureDOOR 2L SLIDE PRESSURE GAUGE BELOW GREEN BAND.SDR HALA0800440Slide · deployedR4 DOOR SLID ACTIVATED AND BLOWN. REMOVED AND REPLACED R4 DOOR SLID PER
AMM 25-66-01-404-036.
SDR SWAA081704Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA081720Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA081717Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA01733Flapper Valve · malfunctionedRT UD SLIDE DEPLOYED. SLIDE PARTIALLY DEFLATED AFTER DEPLOYMENT DURING FAA EVACUATION DRILL.. FLAPPER VALVE RELEASED FROM SLIDE. INSTALLED RT UPPER DECK SLIDE PER MM 25-68-00 REPLACED ASSIST BOTTLE. AC OK FOR SERVICE.SDR SWAA081675Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA081673Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2008UALA01720Sensor · faultyFOUND DOOR 2R SLIDE LIGHT INDICATOR INOP. FOUND A WEAK PROX SENSOR. REPLACED PROX SENSOR 585-3162 AT DOOR 2R AT AFT POSITION.SDR 2008UALA01721Slide · faultyFOUND DOOR L1 SLIDE IS UNLACED.SDR 2008UALA01723Oxygen Bottle · reads lowFOUND DOOR 3L O2 BOTTLE PRESSURE LOW. SUSPECT FAULTY SEAL. REPLACED OXYGEN BOTTLE. AC OK FOR SERVICE.SDR 2008UALA01698Lamp · inoperativeDOOR 2L ARM LIGHT NOT ILLUMINATED WITH DOOR ARMED. CYCLED ARMING LEVER, NO HELP. FOUND LAMP IS OUT IN INDICATOR. RELAMPED DOOR ARM SWITCH AT DOOR 2L AND RESET GIRT BAR, OVERHEAD CB OPS CHECKED NORMAL.
SDR 2008UALA01694Housing · crackedLT OVERWING SLIDE COMPARTMENT DOOR DISCONNECT HOUSING CRACKED AT WELD SEAM.SDR SWAA081602Cable · misroutedDURING SCHEDULED SPV CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR SWAA081648Slide · low pressureDURING SCHEDULED 16Y CHECK, R1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA081580Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA081578Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA01631Light · no test3SV EEL LIGHT FAP TEST FAILED EPSU EXT LOAD FWD L. CAUSE, ELECTRICAL SHORT IN SLIDE NR 1 LT MED SLIDE. REPLACED SLIDE NR 1 LT MED. OPS CHECKED NORMALLY.SDR NWAA081173210Slide · faultyWHILE PERFORMING EMERGENCY LIGHT SYSTEM CHECK PER LINE CHECK "EXT LOADS AFT L" MESSAGE, REF L/P 4273412. REMOVED AND REPLACED 2L EVACUATION SLIDE. CHECKS GOOD.SDR SA08019Slide Raft · bulgedPIT - THE RIGHT, AFT SERVICE DOOR EMERGENCY ESCAPE SLIDE FAILED A CLEARANCE CHECK. MAINTENANCE REPLACED THE RIGHT AFT SERVICE DOOR EMERGENCY ESCAPE SLIDE. INSPECTED OK FOR SERVICE.SDR USAA920080697Slide Raft · deflatedPIT - EES - C11 CHECK - R2 DOOR SLIDE FAILED CLEARANCE CHECK. REPLACED R2 DOOR SLIDE IAW USAIRWAYS TASKCARD 26C84252002.SDR 2008UALA01658Bottle · reads lowESCAPE SLIDE BOTTLE LOW .