Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ZZDA2008008Slide · unserviceableR-1 DOOR SLIDE PRESSURE NOT IN GREEN BAND. REMOVED AND REPLACED R-1 DOOR SLIDE IN REF TO ATM 25-61-03.SDR GTIA0800022Lever · brokenEMERGENCY EXIT DOOR R3 ESCAPE SLIDE RELEASE MECHANISM LEVER BROKEN IPC25-62-02 ITEM 50. REPLACED LEVER.SDR SWAA080219Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA00155Cover · out of positionDOOR 1L SLIDE COVER HAS MOVED AND PREVENTS SEEING PRESSURE GAUGE. REPLACED ENTIRE SLIDE PACK ASSY.SDR UPS08851433Slide · unsecureMAIN DOOR ESCAPE SLIDE NEEDS TO BE REPACKED. RE-SECURED ESCAPE SLIDE.SDR 2008UALA00157Slide · incorrectFORWARD GALLEY DOOR EMERGENCY SLIDE IS NOT PACKED CORRECTLY AT LOWER END OF CLAM SHELL. REPACKED SLIDE.SDR 2008UALA00146Aspirator · leakingASPIRATOR LEAKING. REPLACED ASPIRATOR, CKS GOOD.SDR 2008UALA00145O-Ring · leakingLOW BOTTLE. FOUND CENTER SHAFT O-RING LEAKING. REPLACED O-RING, SERVICED O2 SYSTEM, NO LEAKS NOTED.SDR 2008UALA00144O-Ring · leakingLOW BOTTLE. FOUND LEAK AT THE CENTER O-RING OF THE TANK. REPLACED O-RING ON CENTER SHAFT.SDR SWAA080191Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080167Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080166Slide · out of adjustDURING SCHEDULED BRDG CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080160Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080118Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080150Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR ZZDA2008003Slide · failedR-1 DOOR SLIDE FAILED TO DEPLOY DURING MAINT CHECK. REPLACED DOOR SLIDE ASSY.SDR 2008UALA00058Slide · delaminatedLEFT, OVERWING EXIT, SLIDE PACK, IS DELAMINATING IN TWO AREAS. DELAMINATION - REPLACED SLIDE ASSY.SDR SWAA080119Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080098Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA0042Slide · inoperativeSLIDE LEFT DOOR 2R INOPERATIVE.
SDR 2008UALA0041Aspirator · leakingDAMAGED ASPIRATOR, LEAKING.SDR SWAA080060Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA00019Switch · dirtySLIDE ARMED LIGHT ABOVE DOOR 3R IS ILLUM WHEN SLIDE IS DISARMED. FOUND DIRTY SWITCH. CLEANED SWITCH, OPS CHECKED GOOD.SDR 2008UALA00029Cover · unsecureCREW REPORT: SLIDE PACK 2R HAS FALLEN OFF. RESECURED SLIDE COVER, NO REPEATS SINCE ORIGINAL.SDR R61A200800001Slide · deflatedDURING A SCHEDULE MAINTENANCE CHECK, MAINTENANCE DEPLOYED L1 DOOR SLIDE. SLIDE DEPLOYED CORRECTLY THEN DEFLATED AFTER DEPLOYMENT. MAINTENANCE REMOVED AND REPLACED L1 DOOR SLIDE.SDR 2008UALA0029Slide · out of positionCREW REPORT: SLIDE PACK 2R HAS FALLEN OFF.SDR 2008UALA0019Light · faultySLIDE ARMED LIGHT ABOVE DOOR 3R IS ILLUM WHEN SLIDE IS DISARMED.SDR SWAA080023Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA080032Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080024Slide · out of adjustDURING SCHEDULED THRU CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA05341Cable · brokenRIGHT OVERWING EXIT INFLATION RESERVOIR CABLE BROKEN (INSIDE AFT PIT). REPLACED THE RESERVOIR ASSY, INCLUDING CABLE.SDR 2007UALA05362Indicator · out of positionDOOR 1R SLIDE PACK PRESS GAUGE DIFFICULT TO READ DUE TO POSITION OF INDICATOR. REPLACED SLIDE PACK.SDR 2007UALA05337Slide · shortEMERGENCY LIGHTS TEST FAILS PER 3SVC PAPERWORK. FAULTS EPSU EXT LOAD FWD L. ELECTRICAL SHORT INSIDE SLIDE 1L. REPLACED SLIDE PACK 1L, OPS CHECKED NORMALLY.SDR 2007UALA05338Slide · low pressureDOOR SLIDE 1R PRESSURE LOW. SERVICED SLIDE RES.SDR 2007UALA05316O-Ring · damagedLOW BOTTLE PRESSURE. FOUND PISTON O-RING LEAKING. REPLACE O-RING.SDR SWAA076502Cable · frayedDURING SCHEDULED 24Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE CABLE FRAYED. REMOVED AND REPLACED CABLE PER MM.SDR SWAA076503Cable · frayedDURING SCHEDULED 24Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE FRAYED. REMOVED AND REPLACED CABLE PER MM.SDR UPS08M51359Light · inoperativeINSPECTION TYPE:N/A R1 SLIDE PRESSURE PRESS TO TEST LIGHT INOP. DEFERRED M365742. REMOVED R1 SLIDE, REPLACED R1 SLIDE S/N ON 0169 IAW 25-61-15-4. THIS CLEARS M365742. OPS CHECKS NORMAL.SDR 2007UALA05302O-Ring · leakingDOOR 1L SLIDE BOTTLE PRESSURE READS LOW. FOUND FAULTY O-RING AT GAUGE ELBOW. REPLACED SLIDE ASSEMBLY IAW 25-65-01. AC OK FOR SERVICE.SDR 2007UALA05300Slide · out of positionSLIDE PACK DOOR 1L HAS FALLEN OUT OF POUCH. SUSPECT SLIDE IMPROPERLY INSTALLED. REPLACED SLIDE 1L PER MM25-61-35. AC OK FOR SERVICE.SDR SWAA076519Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA076454Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. SLIDE DID NOT DEPLOY. REINSTALLED SLIDE PER MM.SDR 2007UALA05293Cover · out of positionCREW REPORT: DOOR 1R UNABLE TO SEE SLIDE SIGHT PRESSURE GAUGE. SLIDE IMPROPERLY INSTALLED. REPLACED SLIDE PER MM 25-61-35 P201. AC OK FOR SERVICE.
SDR 2007UALA05279Slide · detachedUPON CLOSING OF DOOR 2L SLIDE DETACHED FROM DOOR. SUSPECT SLIDE IMPROPERLY INSTALLED. REPLACED LEFT REAR DOOR SLIDE. AC OK FOR SERVICE.
SDR SWAA076479Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR UPS07151322Slide · dislodgedMAIN CABIN DOOR SLIDE CAME OUT OF CONTAINER. ESCAPE SLIDE INSTALLED IAW AMM 25-61-21-4.SDR 2007UALA05220Slide · faultyPER EMER LIGHT CK ON 3SVC, LEFT AFT DOOR SLIDE FAILED TEST. ELECTRICAL FAULT IN SLIDE 2L. REPLACED SLIDE 2L- OPS CHECKED NORMAL.SDR SWAA076480Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. SLIDE DID NOT DEPLOY. REINSTALLED SLIDE PER MM.SDR 2007UALA05261Slide · unserviceableDOOR 1L SLIDE LACING VERY LOOSE, SLIDE BULGING AND DIFFICULT TO INSTALL BUSTLE. SUSPECT SLIDE IMPROPERLY PACKED. REPLACED SLIDE REF MM 25-6 9-01. AC OK FOR SERVICE.SDR 2007UALA05247Hose · collapsedRIGHT OVERWING SLIDE INFLATION HOSE COLLAPSED.
Back to JASC 2565